{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,12]],"date-time":"2026-03-12T06:28:42Z","timestamp":1773296922354,"version":"3.50.1"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2013,12,10]],"date-time":"2013-12-10T00:00:00Z","timestamp":1386633600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1007\/s11548-013-0966-8","type":"journal-article","created":{"date-parts":[[2013,12,9]],"date-time":"2013-12-09T17:18:35Z","timestamp":1386609515000},"page":"713-724","source":"Crossref","is-referenced-by-count":35,"title":["A laboratory comparison of computer navigation and individualized guides for distal radius osteotomy"],"prefix":"10.1007","volume":"9","author":[{"given":"Burton","family":"Ma","sequence":"first","affiliation":[]},{"given":"Manuela","family":"Kunz","sequence":"additional","affiliation":[]},{"given":"Braden","family":"Gammon","sequence":"additional","affiliation":[]},{"given":"Randy E.","family":"Ellis","sequence":"additional","affiliation":[]},{"given":"David R.","family":"Pichora","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2013,12,10]]},"reference":[{"issue":"6","key":"966_CR1","doi-asserted-by":"crossref","first-page":"951","DOI":"10.1016\/S0363-5023(03)00375-7","volume":"28A","author":"GS Athwal","year":"2003","unstructured":"Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg 28A(6):951\u2013958","journal-title":"J Hand Surg"},{"issue":"3","key":"966_CR2","doi-asserted-by":"crossref","first-page":"159","DOI":"10.5435\/00124635-200505000-00003","volume":"13","author":"AD Nana","year":"2005","unstructured":"Nana AD, Joshi A, Lichtman DM (2005) Plating of the distal radius. J Am Acad Orthop Surg 13(3):159\u2013171","journal-title":"J Am Acad Orthop Surg"},{"key":"966_CR3","first-page":"356","volume-title":"The wrist: diagnosis and operative treatment","author":"BJ McGrory","year":"1998","unstructured":"McGrory BJ, Amadio PC (1998) Malunion of the distal radius. In: Cooney WP, Linscheid RL, Dobyns JH (eds) The wrist: diagnosis and operative treatment. Mosby, St. Louis, MO, pp 356\u2013384"},{"issue":"1","key":"966_CR4","doi-asserted-by":"crossref","first-page":"27","DOI":"10.5435\/00124635-200701000-00004","volume":"15","author":"BD Bushnell","year":"2007","unstructured":"Bushnell BD, Bynum DK (2007) Malunion of the distal radius. J Am Acad Orthop Surg 15(1):27\u201340","journal-title":"J Am Acad Orthop Surg"},{"issue":"3","key":"966_CR5","doi-asserted-by":"crossref","first-page":"160","DOI":"10.3109\/10929080109146002","volume":"6","author":"H Croitoru","year":"2001","unstructured":"Croitoru H, Ellis RE, Prihar R, Small CF, Pichora DR (2001) Fixation-based surgery: a new technique for distal radius osteotomy. Comput Aided Surg 6(3):160\u2013169","journal-title":"Comput Aided Surg"},{"issue":"3","key":"966_CR6","doi-asserted-by":"crossref","first-page":"406","DOI":"10.1016\/0363-5023(92)90340-U","volume":"17","author":"JB Jupiter","year":"1992","unstructured":"Jupiter JB, Ruder J, Roth DA (1992) Computer-generated bone models in the planning of osteotomy of multidirectional distal radius malunions. J Hand Surg Am 17(3):406\u2013415","journal-title":"J Hand Surg Am"},{"issue":"1","key":"966_CR7","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1109\/TBME.2010.2084576","volume":"58","author":"JGG Dobbe","year":"2011","unstructured":"Dobbe JGG, Strackee SD, Schreurs AW, Jonges R, Carelsen B, Vroemen JC, Grimbergen CA, Streekstra GJ (2011) Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging. IEEE Trans Biomed Eng 58(1):182\u2013190","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"966_CR8","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1007\/s00776-010-0020-4","volume":"16","author":"K Oka","year":"2011","unstructured":"Oka K, Murase T, Moritomo H, Goto A, Nakao R, Sugamoto K, Yoshikawa H (2011) Accuracy of corrective osteotomy using a custom-designed device based on a novel computer simulation system. J Orthop Sci 16(1):85\u201392","journal-title":"J Orthop Sci"},{"issue":"6","key":"966_CR9","doi-asserted-by":"crossref","first-page":"1766","DOI":"10.1007\/s11999-010-1748-z","volume":"469","author":"J Miyake","year":"2011","unstructured":"Miyake J, Murase T, Moritomo H, Sugamoto K, Yoshikawa H (2011) Distal radius osteotomy with volar locking plates based on computer simulation. Clin Orthop Relat Res 469(6):1766\u20131773","journal-title":"Clin Orthop Relat Res"},{"issue":"7","key":"966_CR10","doi-asserted-by":"crossref","first-page":"791","DOI":"10.1007\/s11517-013-1049-2","volume":"51","author":"JG Dobbe","year":"2013","unstructured":"Dobbe JG, Vroemen JC, Strackee SD, Streekstra GJ (2013) Corrective distal radius osteotomy: including bilateral differences in 3-D planning. Med Biol Eng Comput 51(7):791\u2013797","journal-title":"Med Biol Eng Comput"},{"issue":"1\u20132","key":"966_CR11","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1007\/s11517-012-0959-8","volume":"51","author":"JG Dobbe","year":"2013","unstructured":"Dobbe JG, Vroemen JC, Strackee SD, Streekstra GJ (2013) Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy. Med Biol Eng Comput 51(1\u20132):19\u201327","journal-title":"Med Biol Eng Comput"},{"key":"966_CR12","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1097\/00003086-199809000-00005","volume":"354","author":"K Radermacher","year":"1998","unstructured":"Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28\u201338","journal-title":"Clin Orthop Relat Res"},{"issue":"12","key":"966_CR13","doi-asserted-by":"crossref","first-page":"1363","DOI":"10.1007\/s11517-011-0830-3","volume":"49","author":"JG Dobbe","year":"2011","unstructured":"Dobbe JG, Pr\u00e9 KJ, Kloen P, Blankevoort L, Streekstra GJ (2011) Computer-assisted and patient-specific 3-D planning and evaluation of a single-cut rotational osteotomy for complex long-bone deformities. Med Biol Eng Comput 49(12):1363\u20131370","journal-title":"Med Biol Eng Comput"},{"key":"966_CR14","doi-asserted-by":"crossref","unstructured":"Oka K, Moritomo H, Goto A, Sugamoto K, Yoshikawa H, Murase T (2008) Corrective osteotomy for malunited intra-articular fracture of the distal radius using a custom-made surgical guide based on three-dimensional computer simulation: Case report. J Hand Surg Am 33(6):835\u2013840","DOI":"10.1016\/j.jhsa.2008.02.008"},{"issue":"11","key":"966_CR15","doi-asserted-by":"crossref","first-page":"2375","DOI":"10.2106\/JBJS.G.01299","volume":"90","author":"T Murase","year":"2008","unstructured":"Murase T, Oka K, Moritomo H, Goto A, Yoshikawa H, Sugamoto K (2008) Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. J Bone Joint Surg Am 90(11):2375\u20132389","journal-title":"J Bone Joint Surg Am"},{"key":"966_CR16","unstructured":"Ma B, Kunz M, Ling M, Rudan JR, Ellis RE, Abolmaesumi P, Pichora DR (2008) Laboratory and pilot study of customized jigs for distal radius osteotomy. In: Computer assisted orthopaedic surgery: 8th annual meeting of CAOS-international"},{"issue":"3","key":"966_CR17","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/0360-3016(90)90074-T","volume":"18","author":"GW Sherouse","year":"1990","unstructured":"Sherouse GW, Novins K, Chaney EL (1990) Computation of digitally reconstructed radiographs for use in radiotherapy treatment design. Int J Radiat Oncol Biol Phys 18(3):651\u2013658","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"966_CR18","doi-asserted-by":"crossref","unstructured":"Langlotz F (2004) Potential pitfalls of computer aided orthopedic surgery. Injury 35(Suppl 1):S-A17\u2013S-A23","DOI":"10.1016\/j.injury.2004.05.006"},{"issue":"3","key":"966_CR19","doi-asserted-by":"crossref","first-page":"237","DOI":"10.1016\/S1361-8415(02)00133-0","volume":"7","author":"B Ma","year":"2003","unstructured":"Ma B, Ellis RE (2003) Robust registration for computer-integrated orthopedic surgery: laboratory validation and clinical experience. Med Image Anal 7(3):237\u2013250","journal-title":"Med Image Anal"},{"issue":"5","key":"966_CR20","doi-asserted-by":"crossref","first-page":"270","DOI":"10.5435\/00124635-199709000-00005","volume":"5","author":"TJ Graham","year":"1997","unstructured":"Graham TJ (1997) Surgical correction of malunited fractures of the distal radius. J Am Acad Orthop Surg 5(5):270\u2013281","journal-title":"J Am Acad Orthop Surg"},{"key":"966_CR21","doi-asserted-by":"crossref","unstructured":"Aro HT, Koivunen T (1991) Minor axial shortening of the radius affects outcome of Colles\u2019 fracture treatment. J Hand Surg Am 16(3):392\u2013398","DOI":"10.1016\/0363-5023(91)90003-T"},{"key":"966_CR22","doi-asserted-by":"crossref","unstructured":"Fernandez DL, Capo JT, Gonzalez E (2001) Corrective osteotomy for symptomatic increased ulnar tilt of the distal end of the radius. J Hand Surg Am 26(4):722\u2013732","DOI":"10.1053\/jhsu.2001.26033"},{"issue":"3","key":"966_CR23","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1053\/jhsu.2002.31732","volume":"27","author":"C Robertson","year":"2002","unstructured":"Robertson C, Ellis RE, Goetz T, Gofton W, Fenton PV, Small CF, Pichora DR (2002) The sensitivity of carpal bone indices to rotational malpositioning. J Hand Surg Am 27(3):435\u2013442","journal-title":"J Hand Surg Am"},{"issue":"2","key":"966_CR24","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1053\/jhsu.2002.32083","volume":"27","author":"MJ Park","year":"2002","unstructured":"Park MJ, Cooney WP 3rd, Hahn ME, Looi KP, An KN (2002) The effects of dorsally angulated distal radius fractures on carpal kinematics. J Hand Surg Am 27(2):223\u2013232","journal-title":"J Hand Surg Am"},{"issue":"2","key":"966_CR25","doi-asserted-by":"crossref","first-page":"193","DOI":"10.3928\/01477447-20130122-22","volume":"36","author":"JC Vroemen","year":"2013","unstructured":"Vroemen JC, Dobbe JG, Strackee SD, Streekstra GJ (2013) Positioning evaluation of corrective osteotomy for the malunited radius: 3-D CT versus 2-D radiographs. Orthopedics 36(2):193\u2013199","journal-title":"Orthopedics"},{"issue":"1","key":"966_CR26","doi-asserted-by":"crossref","first-page":"150","DOI":"10.1302\/0301-620X.76B1.8300662","volume":"76","author":"R Bili\u0107","year":"1994","unstructured":"Bili\u0107 R, Zdravkovi\u0107 V, Boljevi\u0107 Z (1994) Osteotomy for deformity of the radius: computer-assisted three-dimensional modelling. J Bone Joint Surg Br 76(1):150\u2013154","journal-title":"J Bone Joint Surg Br"},{"issue":"2","key":"966_CR27","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1007\/s11552-009-9233-4","volume":"5","author":"A Schweizer","year":"2010","unstructured":"Schweizer A, F\u00fcrnstahl P, Harders M, Sz\u00e9kely G, Nagy L (2010) Complex radius shaft malunion: osteotomy with computer-assisted planning. Hand 5(2):171\u2013178","journal-title":"Hand"},{"issue":"6","key":"966_CR28","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/S0266-4356(97)90718-X","volume":"35","author":"H Eufinger","year":"1997","unstructured":"Eufinger H, Wehm\u00f6ller M, Machtens E (1997) Individual prostheses and resection templates for mandibular resection and reconstruction. Br J Oral Maxillofac Surg 35(6):413\u2013418","journal-title":"Br J Oral Maxillofac Surg"},{"key":"966_CR29","doi-asserted-by":"crossref","unstructured":"Brown GA, Firoozbakhsh K, DeCoster TA, Reyna JR Jr, Moneim M (2003) Rapid prototyping: the future of trauma surgery? J Bone Joint Surg Am 85-A(Suppl 4):49\u201355","DOI":"10.2106\/00004623-200300004-00006"},{"key":"966_CR30","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/01.blo.0000201148.06454.ef","volume":"444","author":"MA Hafez","year":"2006","unstructured":"Hafez MA, Chelule KL, Seedhom BB, Sherman KP (2006) Computer-assisted total knee arthroplasty using patient-specific templating. Clin Orthop Relat Res 444:184\u2013192","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"966_CR31","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/j.arth.2009.03.023","volume":"25","author":"M Kunz","year":"2010","unstructured":"Kunz M, Rudan JF, Xenoyannis GL, Ellis RE (2010) Computer-assisted hip resurfacing using individualized drill templates. J Arthroplasty 25(4):600\u2013606","journal-title":"J Arthroplasty"},{"key":"966_CR32","doi-asserted-by":"crossref","first-page":"335","DOI":"10.1007\/s11548-010-0476-x","volume":"5","author":"F Rengier","year":"2010","unstructured":"Rengier F, Mehndiratta A, von Tengg-Kobligk H, Zechmann CM, Unterhinninghofen R, Kauczor H-U, Giesel FL (2010) 3D printing based on imaging data: review of medical applications. Int J CARS 5:335\u2013341","journal-title":"Int J CARS"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0966-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-013-0966-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-013-0966-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,4]],"date-time":"2019-08-04T18:28:47Z","timestamp":1564943327000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-013-0966-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2013,12,10]]},"references-count":32,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2014,7]]}},"alternative-id":["966"],"URL":"https:\/\/doi.org\/10.1007\/s11548-013-0966-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2013,12,10]]}}}