{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,26]],"date-time":"2026-08-26T02:37:18Z","timestamp":1787711838607,"version":"build-2784847793"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2014,5,16]],"date-time":"2014-05-16T00:00:00Z","timestamp":1400198400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2015,2]]},"DOI":"10.1007\/s11548-014-1071-3","type":"journal-article","created":{"date-parts":[[2014,5,15]],"date-time":"2014-05-15T15:51:28Z","timestamp":1400169088000},"page":"205-215","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Estimation of optimal pivot point for remote center of motion alignment in surgery"],"prefix":"10.1007","volume":"10","author":[{"given":"Beno\u00eet","family":"Rosa","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Caspar","family":"Gruijthuijsen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ben","family":"Van Cleynenbreugel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jos Vander","family":"Sloten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dominiek","family":"Reynaerts","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel Vander","family":"Poorten","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2014,5,16]]},"reference":[{"issue":"1","key":"1071_CR1","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1186\/1471-2458-8-200","volume":"8","author":"A Bergh\u00f6fer","year":"2008","unstructured":"Bergh\u00f6fer A, Pischon T, Reinhold T, Apovian CM, Sharma AM, Willich SN (2008) Obesity prevalence from a european perspective: a systematic review. BMC Public Health 8(1):200","journal-title":"BMC Public Health"},{"key":"1071_CR2","unstructured":"Bouguet J (2014) MATLAB calibration toolbox. http:\/\/www.vision.caltech.edu\/bouguetj\/calib_doc\/ (consulted March 1)"},{"issue":"5","key":"1071_CR3","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/j.rti.2005.06.008","volume":"11","author":"C Doignon","year":"2005","unstructured":"Doignon C, Graebling P, de Mathelin M (2005) Real-time segmentation of surgical instruments inside the abdominal cavity using a joint hue saturation color feature. Real-Time Imaging 11(5):429\u2013442","journal-title":"Real-Time Imaging"},{"issue":"6","key":"1071_CR4","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1145\/358669.358692","volume":"24","author":"MA Fischler","year":"1981","unstructured":"Fischler MA, Bolles RC (1981) Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun ACM 24(6):381\u2013395","journal-title":"Commun ACM"},{"issue":"2","key":"1071_CR5","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1111\/j.1553-2712.2004.tb01439.x","volume":"11","author":"ML Givens","year":"2004","unstructured":"Givens ML, Ayotte K, Manifold C (2004) Needle thoracostomy: implications of computed tomography chest wall thickness. Acad Emerg Med 11(2):211\u2013213","journal-title":"Acad Emerg Med"},{"key":"1071_CR6","volume-title":"Multiple view geometry in computer vision","author":"R Hartley","year":"2003","unstructured":"Hartley R, Zisserman A (2003) Multiple view geometry in computer vision. Cambridge university press, Cambridge"},{"issue":"2","key":"1071_CR7","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1007\/s10029-010-0757-x","volume":"15","author":"F Helgstrand","year":"2011","unstructured":"Helgstrand F, Rosenberg J, Bisgaard T (2011) Trocar site hernia after laparoscopic surgery: a qualitative systematic review. Hernia 15(2):113\u2013121","journal-title":"Hernia"},{"issue":"3","key":"1071_CR8","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1002\/rcs.263","volume":"5","author":"B Herman","year":"2009","unstructured":"Herman B, Dehez B, Duy KT, Raucent B, Dombre E, Krut S (2009) Design and preliminary in vivo validation of a robotic laparoscope holder for minimally invasive surgery. Int J Med Robot Comput Assist Surg 5(3):319\u2013326","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"1071_CR9","unstructured":"Intuitive Surgical: da Vinci prostatectomy procedure guide. PN 871403 Rev. A 4\/06"},{"issue":"5","key":"1071_CR10","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1109\/TRA.2003.817086","volume":"19","author":"A Krupa","year":"2003","unstructured":"Krupa A, Gangloff J, Doignon C, de Mathelin MF, Morel G, Leroy J, Soler L, Marescaux J (2003) Autonomous 3-d positioning of surgical instruments in robotized laparoscopic surgery using visual servoing. IEEE Trans Robot Autom 19(5):842\u2013853","journal-title":"IEEE Trans Robot Autom"},{"issue":"4","key":"1071_CR11","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1089\/sur.2012.109","volume":"14","author":"MR Kwaan","year":"2013","unstructured":"Kwaan MR, Sirany AM, Rothenberger DA, Madoff RD (2013) Abdominal wall thickness: is it associated with superficial and deep incisional surgical site infection after colorectal surgery? Surg Infect (Larchmt) 14(4):363\u2013368","journal-title":"Surg Infect (Larchmt)"},{"key":"1071_CR12","doi-asserted-by":"crossref","DOI":"10.1007\/978-0-387-21779-6","volume-title":"An invitation to 3-d vision: from images to geometric models, interdisciplinary applied mathematics","author":"Y Ma","year":"2004","unstructured":"Ma Y, Soatto S, Koseck\u00e1 J, Sastry S (2004) An invitation to 3-d vision: from images to geometric models, interdisciplinary applied mathematics, vol 26. Springer, Berlin"},{"key":"1071_CR13","doi-asserted-by":"crossref","unstructured":"Mayer H, Nagy I, Knoll A (2004) Kinematics and modelling of a system for robotic surgery. In: Lenar\u010di\u010d J, Galletti C (eds) On Advances in robot kinematics. Springer, Berlin, pp 181\u2013190","DOI":"10.1007\/978-1-4020-2249-4_20"},{"issue":"4","key":"1071_CR14","doi-asserted-by":"crossref","first-page":"514","DOI":"10.1016\/S1074-3804(05)60529-4","volume":"9","author":"MP Milad","year":"2002","unstructured":"Milad MP, Terkildsen MF (2002) The spinal needle test effectively measures abdominal wall thickness before cannula placement at laparoscopy. J Am Assoc Gynecol Laparosc 9(4):514\u2013518","journal-title":"J Am Assoc Gynecol Laparosc"},{"key":"1071_CR15","unstructured":"Oddsdottir M, Birgisson G (2004) Aesop: a voice-controlled camera holder. In: Ballantyne GH, Marescaux J, Giulianotti PC (eds) Primer of robotic and telerobotic surgery. Chap 5, pp 35\u201341"},{"key":"1071_CR16","first-page":"1","volume":"6","author":"CL Ogden","year":"2010","unstructured":"Ogden CL, Carroll MD (2010) Prevalence of overweight, obesity, and extreme obesity among adults: United States, trends 1960\u20131962 through 2007\u20132008. National Center for Health Statistics 6:1\u20136","journal-title":"National Center for Health Statistics"},{"key":"1071_CR17","doi-asserted-by":"crossref","unstructured":"Ortmaier T, Hirzinger G (2000) Cartesian control issues for minimally invasive robot surgery. In: Intelligent robots and systems, 2000. (IROS 2000). Proceedings 2000 IEEE\/RSJ International Conference on vol 1, pp 565\u2013571. IEEE","DOI":"10.1109\/IROS.2000.894664"},{"issue":"4","key":"1071_CR18","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1002\/rcs.281","volume":"5","author":"MB Ostrowitz","year":"2009","unstructured":"Ostrowitz MB, Eschete D, Zemon H, DeNoto G (2009) Robotic-assisted single-incision right colectomy: early experience. Int J Med Robot Comput Assist Surg 5(4):465\u2013470","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"5","key":"1071_CR19","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1007\/s004649901029","volume":"13","author":"M Schurr","year":"1999","unstructured":"Schurr M, Arezzo A, Neisius B, Rininsland H, Hilzinger HU, Dorn J, Roth K, Buess G (1999) Trocar and instrument positioning system TISKA. Surg Endosc 13(5):528\u2013531","journal-title":"Surg Endosc"},{"issue":"6","key":"1071_CR20","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1007\/s00464-005-0676-6","volume":"20","author":"C Song","year":"2006","unstructured":"Song C, Alijani A, Frank T, Hanna G, Cuschieri A (2006) Mechanical properties of the human abdominal wall measured in vivo during insufflation for laparoscopic surgery. Surg Endosc Other Interv Tech 20(6):987\u2013990","journal-title":"Surg Endosc Other Interv Tech"},{"key":"1071_CR21","unstructured":"Tang HW, Van Brussel H, Peirs J, Janssens T (2010) Remote centre of motion positioner WO Patent 2,010,130,817"},{"key":"1071_CR22","doi-asserted-by":"crossref","unstructured":"Taylor RH, Funda J, Eldridge B, Gomory S, Gruben K, LaRose D, Talamini M, Kavoussi L, Anderson J (1995) A telerobotic assistant for laparoscopic surgery. Eng Med Biol Mag IEEE 14 (3):279\u2013288","DOI":"10.1109\/51.391776"},{"issue":"11","key":"1071_CR23","doi-asserted-by":"crossref","first-page":"1248","DOI":"10.1001\/archsurg.139.11.1248","volume":"139","author":"H Tonouchi","year":"2004","unstructured":"Tonouchi H, Ohmori Y, Kobayashi M, Kusunoki M (2004) Trocar site hernia. Arch Surg 139(11):1248\u20131256","journal-title":"Arch Surg"},{"issue":"6","key":"1071_CR24","first-page":"879","volume":"15","author":"S Voros","year":"2010","unstructured":"Voros S, Haber GP, Menudet JF, Long JA, Cinquin P (2010) Viky robotic scope holder: initial clinical experience and preliminary results using instrument tracking. IEEE\/ASME Trans Mechatron 15(6):879\u2013886","journal-title":"IEEE\/ASME Trans Mechatron"},{"issue":"11\u201312","key":"1071_CR25","doi-asserted-by":"crossref","first-page":"1173","DOI":"10.1177\/0278364907083395","volume":"26","author":"S Voros","year":"2007","unstructured":"Voros S, Long JA, Cinquin P (2007) Automatic detection of instruments in laparoscopic images: A first step towards high-level command of robotic endoscopic holders. Int J Robot Res 26(11\u201312):1173\u20131190","journal-title":"Int J Robot Res"},{"key":"1071_CR26","doi-asserted-by":"crossref","unstructured":"Wilson J, Tsao TC, Hubschman J, Schwartz S (2010) Evaluating remote centers of motion for minimally invasive surgical robots by computer vision. In: Advanced Intelligent Mechatronics (AIM), 2010 IEEE\/ASME International Conference on, pp 1413\u20131418 doi: 10.1109\/AIM.2010.5695924","DOI":"10.1109\/AIM.2010.5695924"},{"key":"1071_CR27","doi-asserted-by":"crossref","unstructured":"Wolf R, Duchateau J, Cinquin P, Voros S (2011) 3d tracking of laparoscopic instruments using statistical and geometric modeling. In: Fichtinger G, Martel A, Peters T (eds) Medical Image Computing and Computer-Assisted Intervention-MICCAI 2011. Springer, Berlin, pp 203\u2013210","DOI":"10.1007\/978-3-642-23623-5_26"},{"issue":"11","key":"1071_CR28","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1109\/34.888718","volume":"22","author":"Z Zhang","year":"2000","unstructured":"Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330\u20131334","journal-title":"IEEE Trans Pattern Anal Mach Intell"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-014-1071-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-014-1071-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-014-1071-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,5,2]],"date-time":"2025-05-02T18:56:53Z","timestamp":1746212213000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-014-1071-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,5,16]]},"references-count":28,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2015,2]]}},"alternative-id":["1071"],"URL":"https:\/\/doi.org\/10.1007\/s11548-014-1071-3","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2014,5,16]]}}}