{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,27]],"date-time":"2026-01-27T08:32:39Z","timestamp":1769502759599,"version":"3.49.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2015,2,26]],"date-time":"2015-02-26T00:00:00Z","timestamp":1424908800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2015,11]]},"DOI":"10.1007\/s11548-015-1163-8","type":"journal-article","created":{"date-parts":[[2015,2,25]],"date-time":"2015-02-25T01:54:15Z","timestamp":1424829255000},"page":"1823-1836","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":96,"title":["Augmented reality in neurovascular surgery: feasibility and first uses in the operating room"],"prefix":"10.1007","volume":"10","author":[{"given":"Marta","family":"Kersten-Oertel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ian","family":"Gerard","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Simon","family":"Drouin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kelvin","family":"Mok","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Denis","family":"Sirhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"David S.","family":"Sinclair","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. Louis","family":"Collins","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,2,26]]},"reference":[{"issue":"3","key":"1163_CR1","doi-asserted-by":"crossref","first-page":"172","DOI":"10.1002\/(SICI)1522-712X(1995)1:3<172::AID-IGS7>3.0.CO;2-7","volume":"1","author":"P Edwards","year":"1995","unstructured":"Edwards P, Hawkes D, Hill D, Jewell D, Spink R, Strong A, Gleeson M (1995) Augmentation of reality using an operating microscope for otolaryngology and neurosurgical guidance. J Image Guid Surg 1(3):172\u2013178","journal-title":"J Image Guid Surg"},{"key":"1163_CR2","volume-title":"Intracranial arteriovenous malformations","author":"P Stieg","year":"2007","unstructured":"Stieg P, Batjer H, Samson D (2007) Intracranial arteriovenous malformations. CRC Press, New York"},{"key":"1163_CR3","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/j.mri.2009.05.042","volume":"28","author":"TA Hope","year":"2010","unstructured":"Hope TA, Hope MD, Purcell DD, von Morze C, Vigneron DB, Alley MT, Dillon WP (2010) Evaluation of intracranial stenoses and aneurysms with accelerated 4D flow. Magn Reson Imaging 28:41\u201346","journal-title":"Magn Reson Imaging"},{"key":"1163_CR4","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9781139523943","volume-title":"Comprehensive management of arteriovenous malformations of the brain and spine","author":"RF Spetzler","year":"2014","unstructured":"Spetzler RF, Kondziolka DS, Higashida RT, Kalani MYS (2014) Comprehensive management of arteriovenous malformations of the brain and spine. Cambridge University Press, Cambridge"},{"key":"1163_CR5","doi-asserted-by":"crossref","first-page":"98","DOI":"10.1016\/j.compmedimag.2013.01.009","volume":"37","author":"M Kersten-Oertel","year":"2013","unstructured":"Kersten-Oertel M, Jannin P, Collins DL (2013) The state of the art of visualization in mixed reality image guided surgery. Comput Med Imaging Graph 37:98\u2013112","journal-title":"Comput Med Imaging Graph"},{"key":"1163_CR6","first-page":"1393","volume":"50","author":"T Kawamata","year":"2002","unstructured":"Kawamata T, Iseki H, Shibasaki T, Hori T (2002) Endoscopic augmented reality navigation system for endonasal transsphenoidal surgery to treat pituitary tumors: technical note. Neurosurgery 50:1393\u20131397","journal-title":"Neurosurgery"},{"key":"1163_CR7","doi-asserted-by":"crossref","unstructured":"Cabrilo I, Bijlenga P, Schaller K (2014) Augmented reality in the surgery of cerebral aneurysms: a technical report. Neurosurgery 10(Suppl. 2):252\u2013260; discussion 260\u2013261","DOI":"10.1227\/NEU.0000000000000328"},{"key":"1163_CR8","doi-asserted-by":"crossref","first-page":"1769","DOI":"10.1007\/s00701-014-2183-9","volume":"156","author":"I Cabrilo","year":"2014","unstructured":"Cabrilo I, Bijlenga P, Schaller K (2014) Augmented reality in the surgery of cerebral arteriovenous malformations: technique assessment and considerations. Acta Neurochir (Wien) 156:1769\u20131774","journal-title":"Acta Neurochir (Wien)"},{"key":"1163_CR9","doi-asserted-by":"crossref","first-page":"1500","DOI":"10.1109\/TMI.2005.857029","volume":"24","author":"P Paul","year":"2005","unstructured":"Paul P, Fleig O, Jannin P (2005) Augmented virtuality based on stereoscopic reconstruction in multimodal image-guided neurosurgery: methods and performance evaluation. IEEE Trans Med Imaging 24:1500\u20131511","journal-title":"IEEE Trans Med Imaging"},{"key":"1163_CR10","doi-asserted-by":"crossref","unstructured":"Rosahl SK, Shahidi R (2008) The virtual operating field\u2014how image guidance can become integral to microneurosurgery. In: Ramina R, de Aguiar PHP, Tatagiba M (eds) Samii\u2019s essentials in neurosurgery. Springer, Berlin, pp 11\u201320","DOI":"10.1007\/978-3-540-49250-4_2"},{"key":"1163_CR11","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1109\/TMI.2002.806597","volume":"21","author":"R Shahidi","year":"2002","unstructured":"Shahidi R, Bax MR, Maurer CR Jr, Johnson JA, Wilkinson EP, Bai W, West JB, Citardi MJ, Manwaring KH, Khadem R (2002) Implementation, calibration and accuracy testing of an image-enhanced endoscopy system. Med Imaging IEEE Trans 21:1524\u20131535","journal-title":"Med Imaging IEEE Trans"},{"key":"1163_CR12","doi-asserted-by":"crossref","first-page":"360","DOI":"10.1162\/105474600566862","volume":"9","author":"AP King","year":"2000","unstructured":"King AP, Edwards PJ, Maurer CR, de Cunha DA, Gaston RP, Clarkson M, Hill DLG, Hawkes DJ, Fenlon MR, Strong AJ, Cox TCS, Gleeson MJ (2000) Stereo augmented reality in the surgical microscope. Presence-Teleoperators Virtual Environ 9:360\u2013368","journal-title":"Presence-Teleoperators Virtual Environ"},{"key":"1163_CR13","doi-asserted-by":"crossref","unstructured":"Gleason PL, Kikinis R, Altobelli D, Wells W, Alexander E, Black PM, Jolesz F (1994) Video registration virtual reality for nonlinkage stereotactic surgery. Stereotact Funct Neurosurg 63:139\u2013143","DOI":"10.1159\/000100305"},{"key":"1163_CR14","unstructured":"Edwards PJ, King AP, Hawkes DJ, Fleig O, Maurer CR Jr, Hill DL, Fenlon MR, de Cunha DA, Gaston RP, Chandra S, Mannss J, Strong AJ, Gleeson MJ, Cox TC (1999) Stereo augmented reality in the surgical microscope. Stud Health Technol Inform 62:102\u2013108"},{"key":"1163_CR15","doi-asserted-by":"crossref","first-page":"N49","DOI":"10.1088\/0031-9155\/48\/3\/402","volume":"48","author":"W Birkfellner","year":"2003","unstructured":"Birkfellner W, Figl M, Matula C, Hummel J, Hanel R, Imhof H, Wanschitz F, Wagner A, Watzinger F, Bergmann H (2003) Computer-enhanced stereoscopic vision in a head-mounted operating binocular. Phys Med Biol 48:N49\u2013N57","journal-title":"Phys Med Biol"},{"key":"1163_CR16","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1109\/TMI.2002.803099","volume":"21","author":"W Birkfellner","year":"2002","unstructured":"Birkfellner W, Figl M, Huber K, Watzinger F, Wanschitz F, Hummel J, Hanel R, Greimel W, Homolka P, Ewers R, Bergmann H (2002) A head-mounted operating binocular for augmented reality visualization in medicine\u2014design and initial evaluation. IEEE Trans Med Imaging 21:991\u2013997","journal-title":"IEEE Trans Med Imaging"},{"key":"1163_CR17","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1007\/s11548-010-0535-3","volume":"6","author":"L Mercier","year":"2011","unstructured":"Mercier L, Del Maestro RF, Petrecca K, Kochanowska A, Drouin S, Yan CX, Janke AL, Chen SJ, Collins DL (2011) New prototype neuronavigation system based on preoperative imaging and intraoperative freehand ultrasound: system description and validation. Int J Comput Assist Radiol Surg 6:507\u2013522","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1163_CR18","doi-asserted-by":"crossref","unstructured":"Gerard I, Collins DL (2015) An analysis of tracking error in image guided neurosurgery. IJCARS 9. doi: 10.1007\/s11548-014-1145-2","DOI":"10.1007\/s11548-014-1145-2"},{"key":"1163_CR19","doi-asserted-by":"crossref","first-page":"892","DOI":"10.1109\/TPAMI.2004.21","volume":"26","author":"Z Zhang","year":"2004","unstructured":"Zhang Z (2004) Camera calibration with one-dimensional objects. IEEE Trans Pattern Anal Mach Intell 26:892\u2013899","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1163_CR20","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.1109\/TMI.2010.2051559","volume":"29","author":"MH Moghari","year":"2010","unstructured":"Moghari MH, Abolmaesumi P (2010) Understanding the effect of bias in fiducial localization error on point-based rigid-body registration. IEEE Trans Med Imaging 29:1730\u20131738","journal-title":"IEEE Trans Med Imaging"},{"key":"1163_CR21","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1097\/00020840-200502000-00008","volume":"13","author":"RF Labadie","year":"2005","unstructured":"Labadie RF, Davis BM, Fitzpatrick JM (2005) Image-guided surgery: what is the accuracy? Curr Opin Otolaryngol Head Neck Surg 13:27\u201331","journal-title":"Curr Opin Otolaryngol Head Neck Surg"},{"key":"1163_CR22","first-page":"5088","volume":"2009","author":"W Liu","year":"2009","unstructured":"Liu W, Ding H, Han H, Xue Q, Sun Z, Wang G (2009) The study of fiducial localization error of image in point-based registration. Conf Proc IEEE Eng Med Biol Soc 2009:5088\u20135091","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"1163_CR23","doi-asserted-by":"crossref","unstructured":"Kersten-Oertel M, Jannin P, Collins DL (2012) DVV: a taxonomy for mixed reality visualization in image guided surgery. IEEE Trans Vis Comput Graph 18:332\u2013352","DOI":"10.1109\/TVCG.2011.50"},{"key":"1163_CR24","doi-asserted-by":"crossref","unstructured":"Drouin S, Kersten-Oertel M, Chen SJS, Collins DL (2012) A realistic test and development environment for mixed reality in neurosurgery. In: Linte CA, Moore JT, Chen ECS, Holmes DR III (eds) Augmented environments for computer-assisted interventions (AE-CAI). Lecture notes in computer science, vol 7264, pp 13\u201323","DOI":"10.1007\/978-3-642-32630-1_2"},{"key":"1163_CR25","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1007\/s11548-009-0365-3","volume":"5","author":"C Hansen","year":"2010","unstructured":"Hansen C, Wieferich J, Ritter F, Rieder C, Peitgen HO (2010) Illustrative visualization of 3D planning models for augmented reality in liver surgery. Int J Comput Assist Radiol Surg 5:133\u2013141","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1163_CR26","first-page":"131","volume":"94","author":"L Johnson","year":"2002","unstructured":"Johnson L, Edwards P, Hawkes D (2002) Surface transparency makes stereo overlays unpredictable: the implications for augmented reality. Stud Health Technol Inform 94:131\u2013136","journal-title":"Stud Health Technol Inform"},{"key":"1163_CR27","first-page":"102","volume":"10","author":"M Lerotic","year":"2007","unstructured":"Lerotic M, Chung AJ, Mylonas G, Yang GZ (2007) Pq-space based non-photorealistic rendering for augmented reality. Med Image Comput Comput Assist Interv 10:102\u2013109","journal-title":"Med Image Comput Comput Assist Interv"},{"issue":"3","key":"1163_CR28","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1109\/TVCG.2013.240","volume":"20","author":"M Kersten-Oertel","year":"2014","unstructured":"Kersten-Oertel M, Chen SJ, Collins DL (2014) An evaluation of depth enhancing perceptual cues for vascular volume visualization in neurosurgery. IEEE Trans Vis Comput Graph 20(3):391\u2013403","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"1163_CR29","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1109\/TVCG.2013.240","volume":"20","author":"M Kersten-Oertel","year":"2013","unstructured":"Kersten-Oertel M, Chen SJ, Collins DL (2013) An evaluation of depth enhancing perceptual cues for vascular volume visualization in neurosurgery. IEEE Trans Vis Comput Graph 20:391\u2013403","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"1163_CR30","doi-asserted-by":"crossref","unstructured":"Kersten-Oertel M, Gerard I, Mok K, Sirhan D, Sinclair D, Collins DL (2014) Augmented reality in neurovascular surgery: first experiences. In: Linte CA, Yaniv Z, Fallavollita P, Abolmaesumi P, Holmes DR III (eds) Augmented environments for computer-assisted interventions (AE-CAI). Lecture notes in computer science, vol 8678, pp 80\u201389","DOI":"10.1007\/978-3-319-10437-9_9"},{"key":"1163_CR31","doi-asserted-by":"crossref","unstructured":"Aschke M, Wirtz CR, Raczkowsky J, Worn H, Kunze S (2003) Augmented reality in operating microscopes for neurosurgical interventions. In: Neural engineering, 2003. Conference Proceedings. First international IEEE EMBS conference on, pp 652\u2013655","DOI":"10.1109\/CNE.2003.1196913"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1163-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-015-1163-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1163-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,21]],"date-time":"2019-08-21T06:53:01Z","timestamp":1566370381000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-015-1163-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,2,26]]},"references-count":31,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2015,11]]}},"alternative-id":["1163"],"URL":"https:\/\/doi.org\/10.1007\/s11548-015-1163-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,2,26]]}}}