{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,30]],"date-time":"2025-09-30T04:32:17Z","timestamp":1759206737712},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2015,10,8]],"date-time":"2015-10-08T00:00:00Z","timestamp":1444262400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2016,4]]},"DOI":"10.1007\/s11548-015-1294-y","type":"journal-article","created":{"date-parts":[[2015,10,8]],"date-time":"2015-10-08T03:09:10Z","timestamp":1444273750000},"page":"621-633","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":6,"title":["A fast, accurate and closed-form method for pose recognition of an intramedullary nail using a tracked C-arm"],"prefix":"10.1007","volume":"11","author":[{"given":"H.","family":"Esfandiari","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S.","family":"Amiri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D. D.","family":"Lichti","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Anglin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2015,10,8]]},"reference":[{"key":"1294_CR1","doi-asserted-by":"crossref","unstructured":"Neatpisarnvanit C, Suthakorn J (2006) Intramedullary nail distal hole axis estimation using blob analysis and Hough transform. In: IEEE conference on robotics, automation and mechatronics. doi: 10.1109\/RAMECH.2006.252685","DOI":"10.1109\/RAMECH.2006.252685"},{"key":"1294_CR2","doi-asserted-by":"crossref","first-page":"461","DOI":"10.1016\/S0020-1383(98)00088-6","volume":"29","author":"LP Muller","year":"1998","unstructured":"Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461\u2013468","journal-title":"Injury"},{"key":"1294_CR3","first-page":"572","volume":"16","author":"C Krettek","year":"1998","unstructured":"Krettek C, Mannss J, Miclau T, Schandelmaier P, Linnemann I, Tscherne H (1998) Deformation of femoral nails with intramedullary insertion. J Bone Joint Surg 16:572\u2013575. doi: 10.1002\/jor.1100160508","journal-title":"J Bone Joint Surg"},{"key":"1294_CR4","doi-asserted-by":"crossref","first-page":"446","DOI":"10.1097\/00005131-199708000-00015","volume":"11","author":"C Krettek","year":"1997","unstructured":"Krettek C, K\u00f6nemann B, Miclau T, Schandelmaier P, Blauth M, Tscherne H (1997) A new technique for the distal locking of solid AO unreamed tibial nails. J Orthop Trauma 11:446\u2013451","journal-title":"J Orthop Trauma"},{"key":"1294_CR5","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1016\/S0020-1383(02)00194-8","volume":"34","author":"KM Abdlslam","year":"2003","unstructured":"Abdlslam KM, Bonnaire F (2003) Experimental model for a new distal locking aiming device for solid intramedullary tibia nails. Injury 34:363\u20136","journal-title":"Injury"},{"key":"1294_CR6","doi-asserted-by":"crossref","unstructured":"Zhu Y, Phillips R, Griffiths JG, Viant W, Mohsen A, Bielby M (2001) Recovery of distal hole axis in intramedullary nail trajectory planning. In: International conference on robotics and automation, pp 1561\u20131566","DOI":"10.1109\/ROBOT.2001.932833"},{"key":"1294_CR7","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1243\/0954411971534412","volume":"211","author":"WJ Viant","year":"1997","unstructured":"Viant WJ, Phillips R, Griffiths JG, Ozanian TO, Mohsen AM, Cain TJ, Karpinski MR, Sherman KP (1997) A computer assisted orthopaedic surgical system for distal locking of intramedullary nails. J Eng Med 211:293\u2013300. doi: 10.1243\/0954411971534412","journal-title":"J Eng Med"},{"key":"1294_CR8","doi-asserted-by":"crossref","unstructured":"Suhm N, Jacob AL, Nolte LP, Regazzoni P, Messmer P (2000) Surgical navigation based on fluoroscopy-clinical application for computer-assisted distal locking of intramedullary implants. Comput Aided Surg 5:391\u2013400. doi: 10.1002\/igs.1001","DOI":"10.1002\/igs.1001"},{"key":"1294_CR9","doi-asserted-by":"crossref","first-page":"1202","DOI":"10.1109\/TMI.2008.920602","volume":"27","author":"T Leloup","year":"2008","unstructured":"Leloup T, El Kazzi W, Schuind F, Warz\u00e9e N (2008) A novel technique for distal locking of intramedullary nail based on two non-constrained fluoroscopic images and navigation. IEEE Trans Med Imaging 27:1202\u20131212. doi: 10.1109\/TMI.2008.920602","journal-title":"IEEE Trans Med Imaging"},{"key":"1294_CR10","doi-asserted-by":"crossref","first-page":"171","DOI":"10.1109\/TMI.2007.904692","volume":"27","author":"G Zheng","year":"2008","unstructured":"Zheng G, Zhang X, Haschtmann D, Gedet P, Dong X, Nolte LP (2008) A robust and accurate two-stage approach for automatic recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures. IEEE Trans Med Imaging 27:171\u2013187. doi: 10.1109\/TMI.2007.904692","journal-title":"IEEE Trans Med Imaging"},{"key":"1294_CR11","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1097\/BOT.0b013e3182828e10","volume":"27","author":"DS Chan","year":"2013","unstructured":"Chan DS, Burris RB, Erdogan M, Sagi HC (2013) The insertion of intramedullary nail locking screws without fluoroscopy: a faster and safer technique. J Orthop Trauma 27:363\u2013366. doi: 10.1097\/BOT.0b013e3182828e10","journal-title":"J Orthop Trauma"},{"key":"1294_CR12","doi-asserted-by":"crossref","first-page":"660","DOI":"10.1302\/0301-620X.73B4.2071655","volume":"73\u2013b","author":"CJM Knudsen","year":"1991","unstructured":"Knudsen CJM, Grobler GP, Close REW (1991) Inserting the distal screws in a locked femoral nail. J Bone Joint Surg 73\u2013b:660\u2013661","journal-title":"J Bone Joint Surg"},{"key":"1294_CR13","doi-asserted-by":"crossref","first-page":"1893","DOI":"10.1097\/01.brs.0000174121.48306.16","volume":"30","author":"R Harstall","year":"2005","unstructured":"Harstall R, Heini PF, Mini RL, Orler R (2005) Radiation exposure to the surgeon during fluoroscopically assisted percutaneous vertebroplasty. Spine 30:1893\u20131898","journal-title":"Spine"},{"key":"1294_CR14","doi-asserted-by":"crossref","unstructured":"Amiri S, Wilson DR, Masri BA, Anglin C (2013) A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging. Int J Comput Assist Radiol Surg 9:695\u2013711. doi: 10.1007\/s11548-013-0957-9","DOI":"10.1007\/s11548-013-0957-9"},{"key":"1294_CR15","unstructured":"Hough PVC, Arbor A (1962) Method and means for recognizing complex patterns. Haugh PVC, Arbor A, Assignee. Patent US3069654 A. 25 Mar 1960"},{"key":"1294_CR16","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1145\/361237.361242","volume":"15","author":"RO Duda","year":"1972","unstructured":"Duda RO, Hart PE (1972) Use of the Hough transformation to detect lines and curves in pictures. Commun ACM 15:11\u201315. doi: 10.1145\/361237.361242","journal-title":"Commun ACM"},{"key":"1294_CR17","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1364\/JOSAA.4.000629","volume":"4","author":"BKP Horn","year":"1987","unstructured":"Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am 4:629\u2013642","journal-title":"J Opt Soc Am"},{"key":"1294_CR18","doi-asserted-by":"crossref","first-page":"784","DOI":"10.1016\/j.jbiomech.2010.10.033","volume":"44","author":"S Acker","year":"2011","unstructured":"Acker S, Li R, Murray H, John PS, Banks S, Mu S, Wyss U, Deluzio K (2011) Accuracy of single-plane fluoroscopy in determining relative position and orientation of total knee replacement components. J Biomech 44:784\u20137. doi: 10.1016\/j.jbiomech.2010.10.033","journal-title":"J Biomech"},{"key":"1294_CR19","doi-asserted-by":"crossref","first-page":"1561","DOI":"10.1109\/TMI.2003.820027","volume":"22","author":"MR Mahfouz","year":"2003","unstructured":"Mahfouz MR, Hoff WA, Komistek RD, Dennis DA (2003) A robust method for registration of three-dimensional knee implant models to two-dimensional fluoroscopy images. IEEE Trans Med Imaging 22:1561\u20131574. doi: 10.1109\/TMI.2003.820027","journal-title":"IEEE Trans Med Imaging"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1294-y.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-015-1294-y\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1294-y","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,31]],"date-time":"2019-08-31T05:23:43Z","timestamp":1567229023000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-015-1294-y"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,10,8]]},"references-count":19,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2016,4]]}},"alternative-id":["1294"],"URL":"https:\/\/doi.org\/10.1007\/s11548-015-1294-y","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,10,8]]}}}