{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,19]],"date-time":"2026-06-19T20:21:03Z","timestamp":1781900463812,"version":"3.54.5"},"reference-count":21,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2015,11,28]],"date-time":"2015-11-28T00:00:00Z","timestamp":1448668800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft (DE)","doi-asserted-by":"publisher","award":["DFG BO 1895\/4-1"],"award-info":[{"award-number":["DFG BO 1895\/4-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2016,7]]},"DOI":"10.1007\/s11548-015-1325-8","type":"journal-article","created":{"date-parts":[[2015,11,28]],"date-time":"2015-11-28T09:43:34Z","timestamp":1448703814000},"page":"1319-1328","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Automatic 3D reconstruction of electrophysiology catheters from two-view monoplane C-arm image sequences"],"prefix":"10.1007","volume":"11","author":[{"given":"Christoph","family":"Baur","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8319-4773","authenticated-orcid":false,"given":"Fausto","family":"Milletari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vasileios","family":"Belagiannis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nassir","family":"Navab","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascal","family":"Fallavollita","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2015,11,28]]},"reference":[{"issue":"10","key":"1325_CR1","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1109\/TMI.2003.817791","volume":"22","author":"SAM Baert","year":"2003","unstructured":"Baert SAM, Van De Kraats EB, van Walsum T, Viergever M, Niessen WJ (2003) Three-dimensional guide-wire reconstruction from biplane image sequences for integrated display in 3-D vasculature. IEEE Trans Med Imaging 22(10):1252\u20131258","journal-title":"IEEE Trans Med Imaging"},{"key":"1325_CR2","doi-asserted-by":"crossref","unstructured":"Belagiannis V, Amin S, Andriluka M, Schiele B, Navab N, Ilic S (2014) 3D pictorial structures for multiple human pose estimation. In: Computer vision and pattern recognition (CVPR), IEEE conference on, pp 1669\u20131676","DOI":"10.1109\/CVPR.2014.216"},{"key":"1325_CR3","doi-asserted-by":"crossref","unstructured":"Bender H-J, M\u00e4nner R, Poliwoda C, Roth S, Walz M (1999) Reconstruction of 3D catheter paths from 2D X-ray projections. In: Medical image computing and computer-assisted intervention-MICCAI\u201999. Springer, Berlin, pp 981\u2013989","DOI":"10.1007\/10704282_107"},{"issue":"1","key":"1325_CR4","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1111\/jce.12264","volume":"25","author":"F Bourier","year":"2014","unstructured":"Bourier F, Fahrig R, Wang P, Santangeli P, Kurzidim K, Strobel N, Moore T, Hinkel C, Al-Ahmad A (2014) Accuracy assessment of catheter guidance technology in electrophysiology procedures. J Cardiovasc Electrophysiol 25(1):74\u201383","journal-title":"J Cardiovasc Electrophysiol"},{"key":"1325_CR5","doi-asserted-by":"crossref","unstructured":"Br\u00fcckner M, Deinzer F, Denzler J (2009) Temporal estimation of the 3D guide-wire position using 2D X-ray images. In: Medical image computing and computer-assisted intervention-MICCAI. Springer, Berlin, pp 386\u2013393","DOI":"10.1007\/978-3-642-04268-3_48"},{"key":"1325_CR6","unstructured":"Fallavollita P (2009) 3D\/2D registration of mapping catheter images for arrhythmia interventional assistance. Int J Comput Sci Issues (IJCSI) 4(2):10\u201319"},{"key":"1325_CR7","doi-asserted-by":"crossref","unstructured":"Fallavollita P (2010) 2D\/3D registration using only single-view fluoroscopy to guide cardiac ablation procedures: a feasibility study. In: SPIE medical imaging. International Society for Optics and Photonics, pp 76252Z\u201376252Z","DOI":"10.1117\/12.844020"},{"key":"1325_CR8","doi-asserted-by":"crossref","unstructured":"Fallavollita P (2010) Acquiring multiview c-arm images to assist cardiac ablation procedures. J Image Video Process 3","DOI":"10.1155\/2010\/871409"},{"key":"1325_CR9","doi-asserted-by":"crossref","unstructured":"Fallavollita P (2010) Is single-view fluoroscopy sufficient in guiding cardiac ablation procedures? J Biomed Imag 1","DOI":"10.1155\/2010\/631264"},{"key":"1325_CR10","doi-asserted-by":"crossref","unstructured":"Fallavollita P (2012) The future of cardiac mapping. INTECH","DOI":"10.5772\/31068"},{"key":"1325_CR11","doi-asserted-by":"crossref","unstructured":"Fallavollita P (2014) Detection, tracking and related costs of ablation catheters in the treatment of cardiac Arrhythmias","DOI":"10.5772\/57424"},{"key":"1325_CR12","doi-asserted-by":"crossref","unstructured":"Hoffmann M, Brost A, Jakob C, Bourier F, Koch M, Kurzidim K, Hornegger J, Strobel N (2012) Semi-automatic catheter reconstruction from two views. In: Medical image computing and computer-assisted intervention-MICCAI. Springer, Berlin, pp 584\u2013591","DOI":"10.1007\/978-3-642-33418-4_72"},{"key":"1325_CR13","doi-asserted-by":"crossref","unstructured":"Hoffmann M, Brost A, Jakob C, Koch M, Bourier F, Kurzidim K, Hornegger J, Strobel N (2013) Reconstruction method for curvilinear structures from two views. In: SPIE medical imaging. International Society for Optics and Photonics, pp 86712F\u201386712F","DOI":"10.1117\/12.2006346"},{"issue":"4","key":"1325_CR14","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1111\/jce.12606","volume":"26","author":"JWE Jarman","year":"2015","unstructured":"Jarman JWE, Panikker S, Das M, Wynn GJ, Ullah W, Kontogeorgis A, Haldar SK (2015) Relationship between contact force sensing technology and medium-term outcome of atrial fibrillation ablation: a multicenter study of 600 patients. J Cardiovasc Electrophysiol 26(4):378\u2013384","journal-title":"J Cardiovasc Electrophysiol"},{"issue":"7","key":"1325_CR15","doi-asserted-by":"crossref","first-page":"071902","DOI":"10.1118\/1.4808114","volume":"40","author":"YL Ma","year":"2013","unstructured":"Ma YL, Gogin N, Cathier P, Housden RJ, Gijsbers G, Cooklin M, O\u2019Neill M (2013) Real-time X-ray fluoroscopy-based catheter detection and tracking for cardiac electrophysiology interventions. Med Phys 40(7):071902","journal-title":"Med Phys"},{"key":"1325_CR16","unstructured":"Milletari F, Belagiannis V, Navab N, Fallavollita P (2014) Fully automatic catheter localization in C-arm images using $$\\ell $$ \u2113 1-sparse coding. In: Medical image computing and computer-assisted intervention-MICCAI. Springer International Publishing, pp 570\u2013577"},{"key":"1325_CR17","doi-asserted-by":"crossref","unstructured":"Milletari F, Navab N, Fallavollita P (2013) Automatic detection of multiple and overlapping EP catheters in fluoroscopic sequences. In: Medical image computing and computer-assisted intervention-MICCAI. Springer, Berlin, pp 371\u2013379","DOI":"10.1007\/978-3-642-40760-4_47"},{"key":"1325_CR18","unstructured":"Papalazarou C, Rongen PMJ, De With PHN (2010) Surgical needle reconstruction using small-angle multi-view X-ray. In: Image processing (ICIP), 17th IEEE international conference on, pp 4193\u20134196"},{"issue":"5","key":"1325_CR19","doi-asserted-by":"crossref","first-page":"612","DOI":"10.1109\/TMI.2005.844073","volume":"24","author":"T Walsum Van","year":"2005","unstructured":"Van Walsum T, Baert SAM, Niessen WJ (2005) Guide wire reconstruction and visualization in 3DRA using monoplane fluoroscopic imaging. IEEE Trans Med Imaging 24(5):612\u2013623","journal-title":"IEEE Trans Med Imaging"},{"key":"1325_CR20","doi-asserted-by":"crossref","unstructured":"Wu W, Chen T, Strobel N, Comaniciu D (2012) Fast tracking of catheters in 2D fluoroscopic images using an integrated CPU-GPU framework. In: Biomedical imaging (ISBI), 9th IEEE international symposium on, pp 1184\u20131187","DOI":"10.1109\/ISBI.2012.6235772"},{"issue":"4","key":"1325_CR21","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1109\/TITB.2012.2189407","volume":"16","author":"L Yatziv","year":"2012","unstructured":"Yatziv L, Chartouni M, Datta S, Sapiro G (2012) Toward multiple catheters detection in fluoroscopic image guided interventions. IEEE Trans Inf Technol Biomed 16(4):770\u2013781","journal-title":"IEEE Trans Inf Technol Biomed"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1325-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-015-1325-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-015-1325-8","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,1]],"date-time":"2019-09-01T21:23:44Z","timestamp":1567373024000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-015-1325-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,11,28]]},"references-count":21,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2016,7]]}},"alternative-id":["1325"],"URL":"https:\/\/doi.org\/10.1007\/s11548-015-1325-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2015,11,28]]}}}