{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,7,31]],"date-time":"2025-07-31T00:33:48Z","timestamp":1753922028112,"version":"3.37.3"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2016,6,1]],"date-time":"2016-06-01T00:00:00Z","timestamp":1464739200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2016,6,1]],"date-time":"2016-06-01T00:00:00Z","timestamp":1464739200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000054","name":"National Cancer Institute","doi-asserted-by":"publisher","award":["1R41CA192504"],"award-info":[{"award-number":["1R41CA192504"]}],"id":[{"id":"10.13039\/100000054","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2016,6]]},"DOI":"10.1007\/s11548-016-1406-3","type":"journal-article","created":{"date-parts":[[2016,6,1]],"date-time":"2016-06-01T06:03:43Z","timestamp":1464761023000},"page":"1163-1171","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":13,"title":["On-demand calibration and evaluation for electromagnetically tracked laparoscope in augmented reality visualization"],"prefix":"10.1007","volume":"11","author":[{"given":"Xinyang","family":"Liu","sequence":"first","affiliation":[]},{"given":"William","family":"Plishker","sequence":"additional","affiliation":[]},{"given":"George","family":"Zaki","sequence":"additional","affiliation":[]},{"given":"Sukryool","family":"Kang","sequence":"additional","affiliation":[]},{"given":"Timothy D.","family":"Kane","sequence":"additional","affiliation":[]},{"given":"Raj","family":"Shekhar","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2016,6,1]]},"reference":[{"issue":"3","key":"1406_CR1","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1109\/TMI.2007.907327","volume":"27","author":"M Feuerstein","year":"2008","unstructured":"Feuerstein M, Mussack T, Heining SM, Navab N (2008) Intraoperative laparoscope augmentation for port placement and resection planning in minimally invasive liver resection. IEEE Trans Med Imaging 27(3):355\u2013369","journal-title":"IEEE Trans Med Imaging"},{"issue":"8","key":"1406_CR2","doi-asserted-by":"publisher","first-page":"1976","DOI":"10.1007\/s00464-010-0890-8","volume":"24","author":"R Shekhar","year":"2010","unstructured":"Shekhar R, Dandekar O, Bhat V, Philip M, Lei P, Godinez C, Sutton E, George I, Kavic S, Mezrich R, Park A (2010) Live augmented reality: a new visualization method for laparoscopic surgery using continuous volumetric computed tomography. Surg Endosc 24(8):1976\u20131985","journal-title":"Surg Endosc"},{"issue":"Pt 1","key":"1406_CR3","first-page":"811","volume":"8","author":"J Leven","year":"2005","unstructured":"Leven J, Burschka D, Kumar R, Zhang G, Blumenkranz S, Dai XD, Awad M, Hager GD, Marohn M, Choti M, Hasser C, Taylor RH (2005) DaVinci canvas: a telerobotic surgical system with integrated, robot-assisted, laparoscopic ultrasound capability. Proc Med Image Comput Comput Assist Interv 8(Pt 1):811\u2013818","journal-title":"Proc Med Image Comput Comput Assist Interv"},{"issue":"Pt 3","key":"1406_CR4","first-page":"408","volume":"13","author":"CL Cheung","year":"2010","unstructured":"Cheung CL, Wedlake C, Moore J, Pautler SE, Peters TM (2010) Fused video and ultrasound images for minimally invasive partial nephrectomy: a phantom study. Proc Med Image Comput Comput Assist Interv 13(Pt 3):408\u2013415","journal-title":"Proc Med Image Comput Comput Assist Interv"},{"issue":"7","key":"1406_CR5","doi-asserted-by":"publisher","first-page":"2227","DOI":"10.1007\/s00464-014-3433-x","volume":"28","author":"X Kang","year":"2014","unstructured":"Kang X, Azizian M, Wilson E, Wu K, Martin AD, Kane TD, Peters CA, Cleary K, Shekhar R (2014) Stereoscopic augmented reality for laparoscopic surgery. Surg Endosc 28(7):2227\u20132235","journal-title":"Surg Endosc"},{"issue":"1","key":"1406_CR6","doi-asserted-by":"publisher","first-page":"16","DOI":"10.1109\/70.88014","volume":"5","author":"Y Shiu","year":"1989","unstructured":"Shiu Y, Ahmad S (1989) Calibration of wrist-mounted robotic sensors by solving homogeneous transform equations of the form ax = xb. IEEE Trans Robot Autom 5(1):16\u201329","journal-title":"IEEE Trans Robot Autom"},{"key":"1406_CR7","unstructured":"Bouguet JY (2015) Camera calibration with OpenCV. \n                    http:\/\/docs.opencv.org\/doc\/tutorials\/calib3d\/camera_calibration\/camera_calibration.html\n                    \n                  . Accessed 20 July 2015"},{"key":"1406_CR8","doi-asserted-by":"crossref","unstructured":"Heikkila J, Silven O (1997) A four-step camera calibration procedure with implicit image correction. In: Proceedings of IEEE computer society conference computer vision pattern recognition. pp 1106\u20131112","DOI":"10.1109\/CVPR.1997.609468"},{"key":"1406_CR9","doi-asserted-by":"crossref","unstructured":"Zhang Z (1999) Flexible camera calibration by viewing a plane from unknown orientations. In: Proceedings of international conference on computer vision. pp 666\u2013673","DOI":"10.1109\/ICCV.1999.791289"},{"key":"1406_CR10","unstructured":"Shekhar R, Liu X, Wilson E, Kang S, Petrosyan M, Kane TD (2015) Stereoscopic augmented reality visualization for laparoscopic surgery\u2014initial clinical experience. In: Proceedings of annual meeting of society of American gastrointestinal and endoscopic surgeons"},{"key":"1406_CR11","doi-asserted-by":"crossref","unstructured":"Barreto JP, Roquette J, Sturm P, Fonseca F (2009) Automatic camera calibration applied to medical endoscopy. In: Proceedings of british machine vision conference","DOI":"10.5244\/C.23.52"},{"issue":"3","key":"1406_CR12","doi-asserted-by":"publisher","first-page":"634","DOI":"10.1109\/TBME.2011.2177268","volume":"59","author":"R Melo","year":"2012","unstructured":"Melo R, Barreto JP, Falc\u00e3o G (2012) A new solution for camera calibration and real-time image distortion correction in medical endoscopy-initial technical evaluation. IEEE Trans Biomed Eng 59(3):634\u2013644","journal-title":"IEEE Trans Biomed Eng"},{"key":"1406_CR13","doi-asserted-by":"crossref","unstructured":"Liu X, Su H, Kang S, Kane TD, Shekhar R (2015) Application of single-image camera calibration for ultrasound augmented laparoscopic visualization. In: Proceedings of SPIE medical, imaging. p 94151T","DOI":"10.1117\/12.2082194"},{"issue":"6","key":"1406_CR14","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1109\/TMI.2008.2008954","volume":"28","author":"M Feuerstein","year":"2009","unstructured":"Feuerstein M, Reichl T, Vogel J, Traub J, Navab N (2009) Magneto-optical tracking of flexible laparoscopic ultrasound: model-based online detection and correction of magnetic tracking errors. IEEE Trans Med Imaging 28(6):951\u2013967","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"1406_CR15","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1118\/1.3075829","volume":"36","author":"Z Yaniv","year":"2009","unstructured":"Yaniv Z, Wilson E, Lindisch D, Cleary K (2009) Electromagnetic tracking in the clinical environment. Med Phys 36(3):876\u2013892","journal-title":"Med Phys"},{"issue":"6","key":"1406_CR16","doi-asserted-by":"publisher","first-page":"813","DOI":"10.1007\/s11548-012-0740-3","volume":"7","author":"AM Franz","year":"2012","unstructured":"Franz AM, M\u00e4rz K, Hummel J, Birkfellner W, Bendl R, Delorme S, Schlemmer HP, Meinzer HP, Maier-Hein L (2012) Electromagnetic tracking for US-guided interventions: standardized assessment of a new compact field generator. Int J Comput Assist Radiol Surg 7(6):813\u2013818","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"6","key":"1406_CR17","doi-asserted-by":"publisher","first-page":"3424","DOI":"10.1118\/1.4712222","volume":"39","author":"L Maier-Hein","year":"2012","unstructured":"Maier-Hein L, Franz AM, Birkfellner W, Hummel J, Gergel I, Wegner I, Meinzer HP (2012) Standardized assessment of new electromagnetic field generators in an interventional radiology setting. Med Phys 39(6):3424\u20133434","journal-title":"Med Phys"},{"key":"1406_CR18","doi-asserted-by":"crossref","unstructured":"Moore JT, Wiles AD, Wedlake C, Bainbridge D, Kiaii B, Luisa Trejos A, Patel R, Peters TM (2010) Integration of trans-esophageal echocardiography with magnetic tracking technology for cardiac interventions. In: Proceedings of SPIE medical, imaging. p 76252Y","DOI":"10.1117\/12.844273"},{"key":"1406_CR19","first-page":"84","volume":"8361","author":"X Liu","year":"2014","unstructured":"Liu X, Kang S, Wilson E, Peters CA, Kane TD, Shekhar R (2014) Evaluation of electromagnetic tracking for stereoscopic augmented reality laparoscopic visualization. Proc MICCAI Workshop Clin Image Based Proced Transl Res Med Imaging 8361:84\u201391","journal-title":"Proc MICCAI Workshop Clin Image Based Proced Transl Res Med Imaging"},{"key":"1406_CR20","unstructured":"Atcheson B, Heide F, Heidrich W (2010) CALTag: High precision fiducial markers for camera calibration. In: 15th International workshop on vision, modeling and visualization. Siegen"},{"key":"1406_CR21","unstructured":"Johnson MP (2003) Exploiting quaternions to support expressive interactive character motion. Dissertation, MIT"},{"issue":"2","key":"1406_CR22","doi-asserted-by":"publisher","first-page":"146","DOI":"10.1006\/cviu.1997.0547","volume":"68","author":"RI Hartley","year":"1997","unstructured":"Hartley RI, Sturm P (1997) Triangulation. Comput Vis Image Underst 68(2):146\u2013157","journal-title":"Comput Vis Image Underst"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1406-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-016-1406-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1406-3","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1406-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T21:37:33Z","timestamp":1589665053000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-016-1406-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,6]]},"references-count":22,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2016,6]]}},"alternative-id":["1406"],"URL":"https:\/\/doi.org\/10.1007\/s11548-016-1406-3","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2016,6]]},"assertion":[{"value":"11 February 2016","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 March 2016","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 June 2016","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}