{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2023,9,17]],"date-time":"2023-09-17T23:01:28Z","timestamp":1694991688800},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,8,5]],"date-time":"2016-08-05T00:00:00Z","timestamp":1470355200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1007\/s11548-016-1432-1","type":"journal-article","created":{"date-parts":[[2016,8,5]],"date-time":"2016-08-05T09:22:35Z","timestamp":1470388955000},"page":"77-90","update-policy":"http:\/\/dx.doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":2,"title":["Design and evaluation of a portable intra-operative unified-planning-and-guidance framework applied to distal radius fracture surgery"],"prefix":"10.1007","volume":"12","author":[{"given":"Jessica","family":"Magaraggia","sequence":"first","affiliation":[]},{"given":"Wei","family":"Wei","sequence":"additional","affiliation":[]},{"given":"Markus","family":"Weiten","sequence":"additional","affiliation":[]},{"given":"Gerhard","family":"Kleinszig","sequence":"additional","affiliation":[]},{"given":"Sven","family":"Vetter","sequence":"additional","affiliation":[]},{"given":"Jochen","family":"Franke","sequence":"additional","affiliation":[]},{"given":"Adrian","family":"John","sequence":"additional","affiliation":[]},{"given":"Adrian","family":"Egli","sequence":"additional","affiliation":[]},{"given":"Karl","family":"Barth","sequence":"additional","affiliation":[]},{"given":"Elli","family":"Angelopoulou","sequence":"additional","affiliation":[]},{"given":"Joachim","family":"Hornegger","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2016,8,5]]},"reference":[{"issue":"12","key":"1432_CR1","doi-asserted-by":"crossref","first-page":"1610","DOI":"10.1302\/0301-620X.88B12.17696","volume":"88","author":"M Al-Rashid","year":"2006","unstructured":"Al-Rashid M, Theivendran K, Craigen M (2006) Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures. J Bone Joint Surg Br 88(12):1610\u20131612","journal-title":"J Bone Joint Surg Br"},{"issue":"5","key":"1432_CR2","doi-asserted-by":"crossref","first-page":"316","DOI":"10.1097\/BOT.0b013e318059b993","volume":"21","author":"R Arora","year":"2007","unstructured":"Arora R, Lutz M, Hennerbichler A, Krappinger D, Espen D, Gabl M (2007) Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate. J Orthop Trauma 21(5):316\u2013322","journal-title":"J Orthop Trauma"},{"key":"1432_CR3","volume-title":"Information theory, coding and cryptography","author":"R Bose","year":"2008","unstructured":"Bose R (2008) Information theory, coding and cryptography. Tata McGraw-Hill Education, Noida"},{"issue":"1","key":"1432_CR4","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/S0019-9958(60)90287-4","volume":"3","author":"RC Bose","year":"1960","unstructured":"Bose RC, Ray-Chaudhuri DK (1960) On a class of error correcting binary group codes. Inf Control 3(1):68\u201379","journal-title":"Inf Control"},{"issue":"7","key":"1432_CR5","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1109\/TC.2009.27","volume":"58","author":"J Cho","year":"2009","unstructured":"Cho J, Sung W (2009) Efficient software-based encoding and decoding of BCH codes. IEEE Trans Comput 58(7):878\u2013889","journal-title":"IEEE Trans Comput"},{"key":"1432_CR6","doi-asserted-by":"crossref","unstructured":"Diotte B, Fallavollita P, Wang L, Weidert S, Thaller PH, Euler E, Navab N (2012) Radiation-free drill guidance in interlocking of intramedullary nails. In: MICCAI, Part I. LNCS, vol 7510, pp 18\u201325","DOI":"10.1007\/978-3-642-33415-3_3"},{"key":"1432_CR7","doi-asserted-by":"crossref","unstructured":"Egli A, Kleinszig G, John A, Fernandez A, Cardelino J (2013) Pose estimation quality assessment for intra-operative image guidance systems. In: SPIE medical imaging, vol 86711","DOI":"10.1117\/12.2007248"},{"key":"1432_CR8","unstructured":"Fiala M (2005) ARTag fiducial marker system applied to vision based spacecraft docking. In: IROS, workshop on robot vision for space applications, pp 35\u201340"},{"issue":"SUPP 28","key":"1432_CR9","first-page":"76","volume":"95","author":"J Franke","year":"2013","unstructured":"Franke J, Vetter S, M\u00fchlh\u00e4user I, Gr\u00fctzner P, von Recum J (2013) Virtual implant planning system: first clinical results. Bone Joint J Orthop Proc Suppl 95(SUPP 28):76\u201376","journal-title":"Bone Joint J Orthop Proc Suppl"},{"key":"1432_CR10","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9780511545726","volume-title":"Practical procedures in orthopaedic trauma surgery","author":"PV Giannoudis","year":"2006","unstructured":"Giannoudis PV, Campbell D, Meier R (2006) Fractures of the distal radius. In: Giannoudis PV, Pape HC (eds) Practical procedures in orthopaedic trauma surgery. Cambridge University Press, Cambridge"},{"issue":"2","key":"1432_CR11","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1016\/j.knee.2007.12.004","volume":"15","author":"JY Jenny","year":"2008","unstructured":"Jenny JY, Miehlke RK, Giurea A (2008) Learning curve in navigated total knee replacement. A multi-centre study comparing experienced and beginner centres. Knee 15(2):80\u201384","journal-title":"Knee"},{"issue":"10","key":"1432_CR12","doi-asserted-by":"crossref","first-page":"1691","DOI":"10.1016\/j.jhsa.2011.07.020","volume":"36","author":"SJ Joseph","year":"2011","unstructured":"Joseph SJ, Harvey JN (2011) The dorsal horizon view: detecting screw protrusion at the distal radius. J Hand Surg 36(10):1691\u20131693","journal-title":"J Hand Surg"},{"key":"1432_CR13","doi-asserted-by":"crossref","unstructured":"Koutenaei BA, Guler O, Wilson E, Thoranaghatte RU, Oetgen M, Navab N, Cleary K (2014) Improved screw placement for slipped capital femoral epiphysis (SCFE) using robotically-assisted drill guidance. In: MICCAI, Part I. LNCS, vol 8673, pp 488\u2013495","DOI":"10.1007\/978-3-319-10404-1_61"},{"key":"1432_CR14","unstructured":"Kreuder F (2009) 2D\u20133D-Registrierung mit Parameterentkopplung f\u00fcr die Patientenlagerung in der Strahlentherapie. Dissertation, vol 7. KIT Scientific Publishing"},{"issue":"6","key":"1432_CR15","doi-asserted-by":"crossref","first-page":"610","DOI":"10.1109\/34.862199","volume":"22","author":"C Lu","year":"2000","unstructured":"Lu C, Hager G, Mjolsness E (2000) Fast and globally convergent pose estimation from video images. IEEE Trans Pattern Anal Mach Intell 22(6):610\u2013622","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1432_CR16","doi-asserted-by":"crossref","unstructured":"Magaraggia J, Kleinszig G, Graumann R, Angelopoulou E, Hornegger J (2013) A video guided solution for screw insertion in orthopedic plate fixation. In: SPIE medical imaging, vol 86710","DOI":"10.1117\/12.2007718"},{"key":"1432_CR17","unstructured":"Magaraggia J, Kleinszig G, Wei W, Weiten M, Graumann R, Angelopoulou E, Hornegger J (2014) On the accuracy of a video-based drill-guidance solution for orthopedic and trauma surgery: preliminary results. In: SPIE medical imaging, vol 903610"},{"key":"1432_CR18","doi-asserted-by":"crossref","unstructured":"Magaraggia J, Wei W, Weiten M, Kleinszig G, Vetter S, Franke J, Barth K, Angelopoulou E, Hornegger J (2015) A portable intra-operative framework applied to distal radius fracture surgery. In: MICCAI, Part I. LNCS, pp 323\u2013330","DOI":"10.1007\/978-3-319-24553-9_40"},{"key":"1432_CR19","volume-title":"Digital media processing: DSP algorithms using C","author":"H Malepati","year":"2010","unstructured":"Malepati H (2010) Digital media processing: DSP algorithms using C. Newnes, Burlington"},{"issue":"4","key":"1432_CR20","doi-asserted-by":"crossref","first-page":"1193","DOI":"10.2514\/1.28949","volume":"30","author":"FL Markley","year":"2007","unstructured":"Markley FL, Cheng Y, Crassidis JL, Oshman Y (2007) Averaging quaternions. J Guid Control Dyn 30(4):1193\u20131197","journal-title":"J Guid Control Dyn"},{"key":"1432_CR21","doi-asserted-by":"crossref","unstructured":"Marziliano P, Dufaux F, Winkler S, Ebrahimi T (2002) A no-reference perceptual blur metric. In: International conference on image processing. IEEE, vol 3, pp 57\u201360","DOI":"10.1109\/ICIP.2002.1038902"},{"issue":"5","key":"1432_CR22","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1053\/jhsu.2001.26662","volume":"26","author":"SD McKay","year":"2001","unstructured":"McKay SD, MacDermid JC, Roth JH, Richards RS (2001) Assessment of complications of distal radius fractures and development of a complication checklist. J Hand Surg 26(5):916\u2013922","journal-title":"J Hand Surg"},{"key":"1432_CR23","doi-asserted-by":"crossref","DOI":"10.1017\/CBO9780511976667","volume-title":"Quantum computation and quantum information","author":"MA Nielsen","year":"2010","unstructured":"Nielsen MA, Chuang IL (2010) Quantum computation and quantum information. Cambridge University Press, Cambridge"},{"key":"1432_CR24","doi-asserted-by":"crossref","unstructured":"Olson E (2011) AprilTag: a robust and flexible visual fiducial system. In: IEEE international conference on robotics and automation. IEEE, pp. 3400\u20133407","DOI":"10.1109\/ICRA.2011.5979561"},{"key":"1432_CR25","doi-asserted-by":"crossref","unstructured":"Pichler W, Grechenig W, Clement H, Windisch G, Tesch N (2009) Perforation of the third extensor compartment by the drill bit during palmar plating of the distal radius. J Hand Surg Eur Vol 34(3):333\u2013335","DOI":"10.1177\/1753193408099821"},{"key":"1432_CR26","unstructured":"Rikli DA, Campbell DA (2007) Distal radius and wrist. In: R\u00fcedi TP, Buckley RE, Renner, Moran CG (eds) AO principles of fracture management. AO Publishing, Davos, Swiss"},{"issue":"1","key":"1432_CR27","doi-asserted-by":"crossref","first-page":"ONS121","DOI":"10.1227\/01.NEU.0000297082.28670.B1","volume":"63","author":"C Schichor","year":"2008","unstructured":"Schichor C, Sch\u00f6ller K, Tanner P, Uhl E, Goldbrunner R, Tonn JC, Witte J (2008) Magnetically guided neuronavigation of flexible instruments in shunt placement, transsphenoidal procedures, and craniotomies. Oper Neurosurg 63(1):ONS121\u2013ONS128","journal-title":"Oper Neurosurg"},{"issue":"12","key":"1432_CR28","doi-asserted-by":"crossref","first-page":"2024","DOI":"10.1109\/TPAMI.2006.252","volume":"28","author":"G Schweighofer","year":"2006","unstructured":"Schweighofer G, Pinz A (2006) Robust pose estimation from a planar target. IEEE Trans Pattern Anal Mach Intell 28(12):2024\u20132030","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1432_CR29","unstructured":"Simic PM, Placzek JD (2011) Distal radius fractures. In: Stannard JP, Schmidt AH, Kregor PJ (eds) Surgical treatment of orthopaedic trauma. Thieme"},{"issue":"4","key":"1432_CR30","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1177\/1753193410392869","volume":"36","author":"T S\u00fcg\u00fcn","year":"2011","unstructured":"S\u00fcg\u00fcn T, Karabay N, G\u00fcrb\u00fcz Y, \u00d6zaksar K, Toros T, Kayalar M (2011) Screw prominences related to palmar locking plating of distal radius. J Hand Surg Eur Vol 36(4):320\u2013324","journal-title":"J Hand Surg Eur Vol"},{"key":"1432_CR31","volume-title":"Introductory techniques for 3-D computer vision","author":"E Trucco","year":"1998","unstructured":"Trucco E, Verri A (1998) Introductory techniques for 3-D computer vision, vol 201. Prentice Hall, Englewood Cliffs"},{"key":"1432_CR32","first-page":"50","volume":"96","author":"S Vetter","year":"2014","unstructured":"Vetter S, M\u00fchlh\u00e4user I, von Recum J, Gr\u00fctzner PA, Franke J (2014) Validation of a virtual implant planning system (VIPS) in distal radius fractures. Bone Joint J Orthop Proc Suppl 96:50\u201350","journal-title":"Bone Joint J Orthop Proc Suppl"},{"key":"1432_CR33","unstructured":"Wagner D, Schmalstieg D (2007) Artoolkitplus for pose tracking on mobile devices. In: CVWW, 12th computer vision winter workshop"},{"key":"1432_CR34","doi-asserted-by":"crossref","DOI":"10.1201\/b18673","volume-title":"VLSI architectures for modern error-correcting codes","author":"X Zhang","year":"2015","unstructured":"Zhang X (2015) VLSI architectures for modern error-correcting codes. CRC Press, Boca Raton"},{"issue":"4","key":"1432_CR35","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1177\/0161734613502004","volume":"35","author":"Y Zhao","year":"2013","unstructured":"Zhao Y, Cachard C, Liebgott H (2013) Automatic needle detection and tracking in 3D ultrasound using an ROI-based RANSAC and Kalman method. Ultrason Imaging 35(4):283\u2013306","journal-title":"Ultrason Imaging"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1432-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-016-1432-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1432-1","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1432-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T20:02:03Z","timestamp":1498334523000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-016-1432-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,8,5]]},"references-count":35,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["1432"],"URL":"https:\/\/doi.org\/10.1007\/s11548-016-1432-1","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,8,5]]}}}