{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T05:25:57Z","timestamp":1778822757041,"version":"3.51.4"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2016,7,12]],"date-time":"2016-07-12T00:00:00Z","timestamp":1468281600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["SCHL 1844\/3-1"],"award-info":[{"award-number":["SCHL 1844\/3-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["ER 817\/1-1"],"award-info":[{"award-number":["ER 817\/1-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1007\/s11548-016-1455-7","type":"journal-article","created":{"date-parts":[[2016,7,12]],"date-time":"2016-07-12T05:08:53Z","timestamp":1468300133000},"page":"149-159","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":15,"title":["Robotic ultrasound-guided SBRT of the prostate: feasibility with respect to plan quality"],"prefix":"10.1007","volume":"12","author":[{"given":"Stefan","family":"Gerlach","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ivo","family":"Kuhlemann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Philipp","family":"Jauer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ralf","family":"Bruder","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Floris","family":"Ernst","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Christoph","family":"F\u00fcrweger","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alexander","family":"Schlaefer","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2016,7,12]]},"reference":[{"issue":"2","key":"1455_CR1","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.radonc.2013.08.030","volume":"109","author":"CR King","year":"2013","unstructured":"King CR, Freeman D, Kaplan I, Fuller D, Bolzicco G, Collins S, Meier R, Wang J, Kupelian P, Steinberg M, Katz A (2013) Stereotactic body radiotherapy for localized prostate cancer: pooled analysis from a multi-institutional consortium of prospective phase II trials. Radiother Oncol 109(2):217\u2013221","journal-title":"Radiother Oncol"},{"issue":"5","key":"1455_CR2","doi-asserted-by":"crossref","first-page":"1588","DOI":"10.1016\/j.ijrobp.2007.11.067","volume":"70","author":"DB Fuller","year":"2008","unstructured":"Fuller DB, Naitoh J, Lee C, Hardy S, Jin H (2008) Virtual HDR cyberknife treatment for localized prostatic carcinoma: dosimetry comparison with HDR brachytherapy and preliminary clinical observations. Int J Radiat Oncol Biol Phys 70(5):1588\u20131597","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"4","key":"1455_CR3","doi-asserted-by":"crossref","first-page":"263","DOI":"10.3109\/10929080009148894","volume":"5","author":"A Schweikard","year":"2000","unstructured":"Schweikard A, Glosser G, Bodduluri M, Murphy MJ, Adler JR (2000) Robotic motion compensation for respiratory movement during radiosurgery. Comput Aided Surg 5(4):263\u2013277","journal-title":"Comput Aided Surg"},{"issue":"1","key":"1455_CR4","doi-asserted-by":"crossref","first-page":"312","DOI":"10.1016\/j.ijrobp.2010.03.011","volume":"79","author":"PJ Keall","year":"2011","unstructured":"Keall PJ, Sawant A, Cho B, Ruan D, Wu J, Poulsen P, Petersen J, Newell LJ, Cattell H, Korreman S (2011) Electromagnetic-guided dynamic multileaf collimator tracking enables motion management for intensity-modulated arc therapy. Int J Radiat Oncol Biol Phys 79(1):312\u2013320","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"8","key":"1455_CR5","doi-asserted-by":"crossref","first-page":"2425","DOI":"10.1088\/0031-9155\/57\/8\/2425","volume":"57","author":"A Krauss","year":"2012","unstructured":"Krauss A, Fast MF, Nill S, Oelfke U (2012) Multileaf collimator tracking integrated with a novel X-ray imaging system and external surrogate monitoring. Phys Med Biol 57(8):2425\u20132439","journal-title":"Phys Med Biol"},{"issue":"2","key":"1455_CR6","doi-asserted-by":"crossref","first-page":"021720","DOI":"10.1118\/1.4862077","volume":"41","author":"S Lang","year":"2014","unstructured":"Lang S, Zeimetz J, Ochsner G, Schmid Daners M, Riesterer O, Kl\u00f6ck S (2014) Development and evaluation of a prototype tracking system using the treatment couch. Med Phys 41(2):021720","journal-title":"Med Phys"},{"issue":"17","key":"1455_CR7","doi-asserted-by":"crossref","first-page":"4021","DOI":"10.1088\/0031-9155\/50\/17\/007","volume":"50","author":"WD D\u2019Souza","year":"2005","unstructured":"D\u2019Souza WD, Naqvi SA, Yu CX (2005) Real-time intra-fraction-motion tracking using the treatment couch: a feasibility study. Phys Med Biol 50(17):4021\u20134033","journal-title":"Phys Med Biol"},{"issue":"2","key":"1455_CR8","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.radonc.2012.12.015","volume":"106","author":"T Depuydt","year":"2013","unstructured":"Depuydt T, Poels K, Verellen D, Engels B, Collen C, Haverbeke C, Gevaert T, Buls N, Van Gompel G, Reynders T, Duchateau M, Tournel K, Boussaer M, Steenbeke F, Vandenbroucke F, De Ridder M (2013) Initial assessment of tumor tracking with a gimbaled linac system in clinical circumstances: a patient simulation study. Radiother Oncol 106(2):236\u2013240","journal-title":"Radiother Oncol"},{"issue":"2","key":"1455_CR9","doi-asserted-by":"crossref","first-page":"5013","DOI":"10.1120\/jacmp.v16i2.5013","volume":"16","author":"X Tong","year":"2015","unstructured":"Tong X, Chen X, Li J, Xu Q, Lin MH, Chen L, Price RA, Ma CM (2015) Intrafractional prostate motion during external beam radiotherapy monitored by a real-time target localization system. J Appl Clin Med Phys 16(2):5013","journal-title":"J Appl Clin Med Phys"},{"issue":"4","key":"1455_CR10","doi-asserted-by":"crossref","first-page":"1088","DOI":"10.1016\/j.ijrobp.2006.10.026","volume":"67","author":"P Kupelian","year":"2007","unstructured":"Kupelian P, Willoughby T, Mahadevan A, Djemil T, Weinstein G, Jani S, Enke C, Solberg T, Flores N, Liu D, Beyer D, Levine L (2007) Multi-institutional clinical experience with the Calypso system in localization and continuous, real-time monitoring of the prostate gland during external radiotherapy. Int J Radiat Oncol Biol Phys 67(4):1088\u20131098","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"1455_CR11","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1016\/j.semradonc.2014.02.011","volume":"24","author":"BG Fallone","year":"2014","unstructured":"Fallone BG (2014) The rotating biplanar linac-magnetic resonance imaging system. Semin Radiat Oncol 24(3):200\u2013202","journal-title":"Semin Radiat Oncol"},{"key":"1455_CR12","doi-asserted-by":"crossref","unstructured":"Keall PJ, Barton M, Crozier S (2014) On behalf of the Australian MRI-Linac Program, including contributors from the Ingham Institute, Illawarra Cancer Care Centre, Liverpool Hospital, Stanford University, Universities of Newcastle, Queensland, Sydney, Western Sydney, and Wollongong. The Australian magnetic resonance imaging-linac program. Semin Radiat Oncol 24(3):203\u2013206","DOI":"10.1016\/j.semradonc.2014.02.015"},{"issue":"1","key":"1455_CR13","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1016\/j.radonc.2007.10.034","volume":"86","author":"JJ Lagendijk","year":"2008","unstructured":"Lagendijk JJ, Raaymakers BW, Raaijmakers AJ, Overweg J, Brown KJ, Kerkhof EM, van der Put RW, H\u00e5rdemark B, van Vulpen M, van der Heide UA (2008) MRI\/linac integration. Radiother Oncol 86(1):25\u201329","journal-title":"Radiother Oncol"},{"key":"1455_CR14","doi-asserted-by":"crossref","unstructured":"Bruder R, Ernst F, Schlaefer A, Schweikard A (2009) TH-C-304A-07: real-time tracking of the pulmonary veins in 3D ultrasound of the beating heart. 51st Annual meeting of the AAPM. Med Phys, vol 36, p 2804","DOI":"10.1118\/1.3182643"},{"key":"1455_CR15","unstructured":"Bruder R, Ernst F, Schlaefer A, Schweikard A (2011) A framework for real-time target tracking in radiosurgery using three-dimensional ultrasound. In: Proceedings of the 25th international congress and exhibition on computer assisted radiology and surgery (CARS\u201911), Int J CARS, vol 6, pp S306\u2013S307"},{"issue":"12","key":"1455_CR16","doi-asserted-by":"crossref","first-page":"6357","DOI":"10.1118\/1.3515457","volume":"37","author":"J Schlosser","year":"2010","unstructured":"Schlosser J, Salisbury K, Hristov D (2010) Telerobotic system concept for real-time soft-tissue imaging during radiotherapy beam delivery. Med Phys 37(12):6357\u20136367","journal-title":"Med Phys"},{"issue":"12","key":"1455_CR17","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1007\/s00066-008-1837-z","volume":"184","author":"M Bohrer","year":"2008","unstructured":"Bohrer M, Schr\u00f6der P, Welzel G, Wertz H, Lohr F, Wenz F, Mai SK (2008) Reduced rectal toxicity with ultrasound-based image guided radiotherapy using BAT (B-mode acquisition and targeting system) for prostate cancer. Strahlenther Onkol 184(12):674\u2013678","journal-title":"Strahlenther Onkol"},{"issue":"5","key":"1455_CR18","doi-asserted-by":"crossref","first-page":"1562","DOI":"10.1016\/j.ijrobp.2006.07.1375","volume":"66","author":"FL Cury","year":"2006","unstructured":"Cury FL, Shenouda G, Souhami L, Duclos M, Faria SL, David M, Verhaegen F, Corns R, Falco T (2006) Ultrasound-based image guided radiotherapy for prostate cancer: comparison of cross-modality and intramodality methods for daily localization during external beam radiotherapy. Int J Radiat Oncol Biol Phys 66(5):1562\u20131567","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1455_CR19","doi-asserted-by":"crossref","unstructured":"Bruder R, Ernst F, Schweikard A (2011) SU-D-220-02: optimal transducer positions for 4D ultrasound guidance in cardiac IGRT. 53rd Annual meeting of the AAPM. Med Phys, vol 38, p 3390","DOI":"10.1118\/1.3611550"},{"key":"1455_CR20","doi-asserted-by":"crossref","unstructured":"Kuhlemann I, Bruder R, Ernst F, Schweikard A (2014) WEG-BRF-09: force-and image-adaptive strategies for robotised placement of 4D ultrasound probes. 56th Annual meeting of the AAPM. Med Phys, vol 41, p 523","DOI":"10.1118\/1.4889502"},{"key":"1455_CR21","doi-asserted-by":"crossref","unstructured":"Bortfeld T (2010) The number of beams in IMRT-theoretical investigations and implications for single-arc IMRT. Phys Med Biol 55(1):83\u201397","DOI":"10.1088\/0031-9155\/55\/1\/006"},{"key":"1455_CR22","doi-asserted-by":"crossref","unstructured":"Stein J, Mohan R, Wang XH, Bortfeld T, Wu Q, Preiser K, Ling CC, Schlegel W (1997) Number and orientations of beams in intensity-modulated radiation treatments. Med Phys 24(2):149\u2013160","DOI":"10.1118\/1.597923"},{"key":"1455_CR23","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s11548-008-0159-z","volume":"3","author":"A Schlaefer","year":"2008","unstructured":"Schlaefer A, Gill J, Schweikard A (2008) A simulation and training environment for robotic radiosurgery. Int J CARS 3:267\u2013274","journal-title":"Int J CARS"},{"issue":"18","key":"1455_CR24","doi-asserted-by":"crossref","first-page":"5359","DOI":"10.1088\/0031-9155\/54\/18\/001","volume":"54","author":"GG Echner","year":"2009","unstructured":"Echner GG, Kilby W, Lee M, Earnst E, Sayeh S, Schlaefer A, Rhein B, Dooley JR, Lang C, Blanck O, Lessard E, Maurer CR Jr, Schlegel W (2009) The design, physical properties and clinical utility of an iris collimator for robotic radiosurgery. Phys Med Biol 54(18):5359\u20135380","journal-title":"Phys Med Biol"},{"issue":"11","key":"1455_CR25","doi-asserted-by":"crossref","first-page":"4005","DOI":"10.1118\/1.2357020","volume":"33","author":"A Schweikard","year":"2006","unstructured":"Schweikard A, Schlaefer A, Adler JR Jr (2006) Resampling: an optimization method for inverse planning in robotic radiosurgery. Med Phys 33(11):4005\u20134011","journal-title":"Med Phys"},{"issue":"5","key":"1455_CR26","doi-asserted-by":"crossref","first-page":"2094","DOI":"10.1118\/1.2900716","volume":"35","author":"A Schlaefer","year":"2008","unstructured":"Schlaefer A, Schweikard A (2008) Stepwise multi-criteria optimization for robotic radiosurgery. Med Phys 35(5):2094\u20132103","journal-title":"Med Phys"},{"issue":"3","key":"1455_CR27","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.ijrobp.2014.10.049","volume":"91","author":"DM Lovelock","year":"2015","unstructured":"Lovelock DM, Messineo AP, Cox BW, Kollmeier MA, Zelefsky MJ (2015) Continuous monitoring and intrafraction target position correction during treatment improves target coverage for patients undergoing SBRT prostate therapy. Int J Radiat Oncol Biol Phys 91(3):588\u2013594","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"1455_CR28","unstructured":"\u015een HT, Lediju BMA, Zhang Y, Ding K, Wong J, Iordachita I, Kazanzides P (2015) System integration and preliminary in-vivo experiments of a robot for ultrasound guidance and monitoring during radiotherapy. In: Proceedings of the international conference on advanced robotics, 2015, pp 53\u201359"},{"issue":"10","key":"1455_CR29","doi-asserted-by":"crossref","first-page":"5745","DOI":"10.1118\/1.4929978","volume":"42","author":"M Bazalova-Carter","year":"2015","unstructured":"Bazalova-Carter M, Schlosser J, Chen J, Hristov D (2015) Monte Carlo modeling of ultrasound probes for image guided radiotherapy. Med Phys 42(10):5745\u20135756","journal-title":"Med Phys"},{"key":"1455_CR30","doi-asserted-by":"publisher","unstructured":"Schlosser J, Hristov D (2016) Radiolucent 4D ultrasound imaging: system design and application to radiotherapy guidance. IEEE Trans Med Imaging. doi: 10.1109\/TMI.2016.2559499","DOI":"10.1109\/TMI.2016.2559499"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1455-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-016-1455-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1455-7","content-type":"unspecified","content-version":"vor","intended-application":"similarity-checking"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-016-1455-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T14:15:05Z","timestamp":1498313705000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-016-1455-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,7,12]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2017,1]]}},"alternative-id":["1455"],"URL":"https:\/\/doi.org\/10.1007\/s11548-016-1455-7","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2016,7,12]]}}}