{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:42:28Z","timestamp":1790635348632,"version":"4.1.0"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2017,3,3]],"date-time":"2017-03-03T00:00:00Z","timestamp":1488499200000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13GW0095A"],"award-info":[{"award-number":["13GW0095A"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,9]]},"DOI":"10.1007\/s11548-017-1546-0","type":"journal-article","created":{"date-parts":[[2017,3,3]],"date-time":"2017-03-03T04:57:57Z","timestamp":1488517077000},"page":"1621-1633","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A software solution to dynamically reduce metallic distortions of electromagnetic tracking systems for image-guided surgery"],"prefix":"10.1007","volume":"12","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5653-3725","authenticated-orcid":false,"given":"Mengfei","family":"Li","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christian","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Georg","family":"Rose","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,3,3]]},"reference":[{"key":"1546_CR1","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1097\/01.RVI.0000148827.62296.B4","volume":"16","author":"BJ Wood","year":"2005","unstructured":"Wood BJ, Zhang H, Durrani A, Glossop N, Ranjan S, Lindisch D, Levy E, Banovac F, Borgert J, Krueger S, Kruecker J, Viswanathan A, Cleary K (2005) Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. J Vasc Interv Radiol 16:493\u2013505. doi:\n                        10.1097\/01.RVI.0000148827.62296.B4","journal-title":"J Vasc Interv Radiol"},{"key":"1546_CR2","doi-asserted-by":"publisher","first-page":"1845","DOI":"10.1007\/s11548-015-1176-3","volume":"10","author":"N Shahriari","year":"2015","unstructured":"Shahriari N, Hekman E, Oudkerk M, Misra S (2015) Design and evaluation of a computed tomography (CT)-compatible needle insertion device using an electromagnetic tracking system and CT images. Int J Comput Assist Radiol Surg 10:1845\u20131852. doi:\n                        10.1007\/s11548-015-1176-3","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1546_CR3","doi-asserted-by":"publisher","first-page":"1431","DOI":"10.1007\/s11548-015-1326-7","volume":"11","author":"H Sorger","year":"2016","unstructured":"Sorger H, Hofstad EF, Amundsen T, Lang\u00f8 T, Leira HO (2016) A novel platform for electromagnetic navigated ultrasound bronchoscopy (EBUS). Int J Comput Assist Radiol Surg 11:1431\u20131443. doi:\n                        10.1007\/s11548-015-1326-7","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1546_CR4","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S1010-5182(99)80017-1","volume":"27","author":"F Watzinger","year":"1999","unstructured":"Watzinger F, Birkfellner W, Wanschitz F, Millesi W, Schopper C, Sinko K, Huber K, Bergmann H, Ewers R (1999) Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. J Craniomaxillofac Surg 27:77\u201381","journal-title":"J Craniomaxillofac Surg"},{"key":"1546_CR5","doi-asserted-by":"publisher","first-page":"280","DOI":"10.5114\/jcb.2015.54062","volume":"7","author":"S Boutaleb","year":"2015","unstructured":"Boutaleb S, Racine E, Fillion O, Bonillas A, Hautvast G, Binnekamp D, Beaulieu L (2015) Performance and suitability assessment of a real-time 3D electromagnetic needle tracking system for interstitial brachytherapy. J Contemp Brachytherapy 7:280\u2013289. doi:\n                        10.5114\/jcb.2015.54062","journal-title":"J Contemp Brachytherapy"},{"key":"1546_CR6","doi-asserted-by":"publisher","first-page":"2242","DOI":"10.1118\/1.598425","volume":"25","author":"W Birkfellner","year":"1998","unstructured":"Birkfellner W, Watzinger F, Wanschitz F, Enislidis G, Kollmann C, Rafolt D, Nowotny R, Ewers R, Bergmann H (1998) Systematic distortions in magnetic position digitizers. Med Phys 25:2242. doi:\n                        10.1118\/1.598425","journal-title":"Med Phys"},{"key":"1546_CR7","doi-asserted-by":"publisher","unstructured":"Nafis C, Jensen V, Beauregard L, Anderson P (2006) Method for estimating dynamic EM tracking accuracy of surgical navigation tools. In: Cleary KR, Galloway Jr. RL (eds) Medical imaging, vol 6141, pp 152\u2013167. doi:\n                        10.1117\/12.653448","DOI":"10.1117\/12.653448"},{"key":"1546_CR8","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1002\/cmr.a.10066","volume":"18A","author":"PW Kuchel","year":"2003","unstructured":"Kuchel PW, Chapman BE, Bubb WA, Hansen PE, Durrant CJ, Hertzberg MP (2003) Magnetic susceptibility: solutions, emulsions, and cells. Concepts Magn Reson 18A:56\u201371. doi:\n                        10.1002\/cmr.a.10066","journal-title":"Concepts Magn Reson"},{"key":"1546_CR9","doi-asserted-by":"publisher","first-page":"2922","DOI":"10.1109\/20.92289","volume":"24","author":"P Garikepati","year":"1988","unstructured":"Garikepati P, Chang TT, Jiles DC (1988) Theory of ferromagnetic hysteresis: evaluation of stress from hysteresis curves. IEEE Trans Magn 24:2922\u20132924. doi:\n                        10.1109\/20.92289","journal-title":"IEEE Trans Magn"},{"key":"1546_CR10","doi-asserted-by":"publisher","first-page":"733","DOI":"10.1016\/S0021-9290(02)00036-2","volume":"35","author":"F Poulin","year":"2002","unstructured":"Poulin F, Amiot L-PL-P (2002) Interference during the use of an electromagnetic tracking system under OR conditions. J Biomech 35:733\u20137. doi:\n                        10.1016\/S0021-9290(02)00036-2","journal-title":"J Biomech"},{"key":"1546_CR11","doi-asserted-by":"publisher","first-page":"169","DOI":"10.1007\/BF01409422","volume":"5","author":"VV Kindratenko","year":"2000","unstructured":"Kindratenko VV (2000) A survey of electromagnetic position tracker calibration techniques. Virtual Real 5:169\u2013182. doi:\n                        10.1007\/BF01409422","journal-title":"Virtual Real"},{"key":"1546_CR12","doi-asserted-by":"publisher","first-page":"4525","DOI":"10.1109\/TMAG.2008.2003056","volume":"44","author":"A Plotkin","year":"2008","unstructured":"Plotkin A, Kucher V, Horen Y, Paperno E (2008) A new calibration procedure for magnetic tracking systems. IEEE Trans Magn 44:4525\u20134528. doi:\n                        10.1109\/TMAG.2008.2003056","journal-title":"IEEE Trans Magn"},{"key":"1546_CR13","unstructured":"Dumoulin CL (2001) Error compensation for device tracking systems employing electromagnetic fields. Patent US 6,201,987"},{"key":"1546_CR14","unstructured":"Jascob B, Kessman P, Simon D, Smith A (2003) Method and apparatus for electromagnetic navigation of a surgical probe near a metal object. Patent US 6,636,757"},{"key":"1546_CR15","unstructured":"Rolland JP, Larry DD, Bailot Y (2001) A survey of tracking technology for virtual environments. In: Barfield W, Caudell T (eds) Fundamentals of wearable computers and augmented reality. CRC Press, New Jersey, p 836"},{"key":"1546_CR16","unstructured":"Anderson PT (2010) Ultra-low frequency electromagnetic tracking system. Patent US 7,761,100"},{"key":"1546_CR17","unstructured":"Hansen PK, Ashe WS (1998) Magnetic field position and orientation measurement system with dynamic eddy current rejection. Patent US 5,767,669"},{"key":"1546_CR18","doi-asserted-by":"publisher","first-page":"1938","DOI":"10.1109\/20.951014","volume":"37","author":"E Paperno","year":"2001","unstructured":"Paperno E, Sasada I, Leonovich E (2001) A new method for magnetic position and orientation tracking. IEEE Trans Magn 37:1938\u20131940. doi:\n                        10.1109\/20.951014","journal-title":"IEEE Trans Magn"},{"key":"1546_CR19","doi-asserted-by":"publisher","first-page":"323","DOI":"10.1007\/s11548-013-0925-4","volume":"9","author":"T Bien","year":"2014","unstructured":"Bien T, Li M, Salah Z, Rose G (2014) Electromagnetic tracking system with reduced distortion using quadratic excitation. Int J Comput Assist Radiol Surg 9:323\u201332. doi:\n                        10.1007\/s11548-013-0925-4","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1546_CR20","unstructured":"Nieminen JM, Kirsch SR (2010) Eddy current detection and compensation. Patent US 7,783,441"},{"key":"1546_CR21","doi-asserted-by":"publisher","first-page":"1105","DOI":"10.1109\/TCSI.2009.2030092","volume":"57","author":"A Hajimiri","year":"2010","unstructured":"Hajimiri A (2010) Generalized Time- and Transfer-Constant Circuit Analysis. IEEE Trans Circuits Syst I Regul Pap 57:1105\u20131121. doi:\n                        10.1109\/TCSI.2009.2030092","journal-title":"IEEE Trans Circuits Syst I Regul Pap"},{"key":"1546_CR22","doi-asserted-by":"publisher","unstructured":"Doetsch G (1974) Introduction to the theory and application of the Laplace transformation. doi:\n                        10.1007\/978-3-642-65690-3","DOI":"10.1007\/978-3-642-65690-3"},{"key":"1546_CR23","doi-asserted-by":"crossref","unstructured":"Rosa EB (1908) The self and mutual inductances of linear conductors. In: Bulletin Bureau Stand. U.S. Dept. of Commerce and Labor, Bureau of Standards, pp 302\u2013305","DOI":"10.6028\/bulletin.088"},{"key":"1546_CR24","volume-title":"Foundations of electronics","author":"RL Meade","year":"2002","unstructured":"Meade RL (2002) Foundations of electronics. Cengage Learning, Boston, USA"},{"key":"1546_CR25","doi-asserted-by":"publisher","first-page":"709","DOI":"10.1109\/TAES.1979.308860","volume":"15","author":"F Raab","year":"1979","unstructured":"Raab F, Blood E, Steiner T, Jones H (1979) Magnetic position and orientation tracking system. IEEE Trans Aerosp Electron Syst AES 15:709\u2013718. doi:\n                        10.1109\/TAES.1979.308860","journal-title":"IEEE Trans Aerosp Electron Syst AES"},{"key":"1546_CR26","doi-asserted-by":"publisher","first-page":"2566","DOI":"10.14299\/ijser.2013.09.001","volume":"4","author":"M Li","year":"2013","unstructured":"Li M, Bien T, Rose G (2013) FPGA based electromagnetic tracking system for fast catheter navigation. Int J Sci Eng Res 4:2566\u20132570. doi:\n                        10.14299\/ijser.2013.09.001","journal-title":"Int J Sci Eng Res"},{"key":"1546_CR27","volume-title":"Dynamic response of electromagnetic spatial displacement trackers, vol 5, no 3","author":"BD Adelstein","year":"1996","unstructured":"Adelstein BD, Johnston ER, Ellis SR (1996) Dynamic response of electromagnetic spatial displacement trackers, vol 5, no 3. Presence, Cambridge"},{"issue":"14","key":"1546_CR28","doi-asserted-by":"crossref","first-page":"2241","DOI":"10.1088\/0031-9155\/48\/14\/314","volume":"48","author":"DD Frantz","year":"2003","unstructured":"Frantz DD, Wiles AD, Leis SE, Kirsch SR (2003) Accuracy assessment protocols for electromagnetic tracking systems. Phys Med Biol 48(14):2241\u20132251","journal-title":"Phys Med Biol"},{"key":"1546_CR29","doi-asserted-by":"crossref","unstructured":"Wiles AD, Thompson DG, Frantz DD (2004) Accuracy assessment and interpretation for optical tracking systems. In: Galloway Jr RL (ed) SPIE medical international society for optics and photonics, imaging, pp 421\u2013432","DOI":"10.1117\/12.536128"},{"key":"1546_CR30","doi-asserted-by":"publisher","first-page":"N205-10","DOI":"10.1088\/0031-9155\/51\/10\/N01","volume":"51","author":"J Hummel","year":"2006","unstructured":"Hummel J, Figl M, Birkfellner W, Bax MR, Shahidi R, Maurer CR, Bergmann H (2006) Evaluation of a new electromagnetic tracking system using a standardized assessment protocol. Phys Med Biol 51:N205-10. doi:\n                        10.1088\/0031-9155\/51\/10\/N01","journal-title":"Phys Med Biol"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-017-1546-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1546-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1546-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,8,23]],"date-time":"2017-08-23T07:06:54Z","timestamp":1503472014000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-017-1546-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,3,3]]},"references-count":30,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2017,9]]}},"alternative-id":["1546"],"URL":"https:\/\/doi.org\/10.1007\/s11548-017-1546-0","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,3,3]]}}}