{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,17]],"date-time":"2026-07-17T21:53:43Z","timestamp":1784325223987,"version":"3.55.0"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2017,6,29]],"date-time":"2017-06-29T00:00:00Z","timestamp":1498694400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Nova Scotia Health Authority"},{"DOI":"10.13039\/501100000146","name":"Alberta Innovates - Technology Futures","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000146","id-type":"DOI","asserted-by":"publisher"}]},{"name":"German Federal Ministry of Education and Research"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,12]]},"DOI":"10.1007\/s11548-017-1630-5","type":"journal-article","created":{"date-parts":[[2017,6,29]],"date-time":"2017-06-29T10:48:43Z","timestamp":1498733323000},"page":"2097-2105","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Validation of three-dimensional models of the distal femur created from surgical navigation point cloud data for intraoperative and postoperative analysis of total knee arthroplasty"],"prefix":"10.1007","volume":"12","author":[{"given":"David A. J.","family":"Wilson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carolyn","family":"Anglin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Felix","family":"Ambellan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Carl Martin","family":"Grewe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alexander","family":"Tack","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hans","family":"Lamecker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Dunbar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stefan","family":"Zachow","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,6,29]]},"reference":[{"issue":"1","key":"1630_CR1","doi-asserted-by":"publisher","first-page":"57","DOI":"10.1007\/s11999-009-1119-9","volume":"468","author":"RB Bourne","year":"2010","unstructured":"Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KD (2010) Patient satisfaction after total knee arthroplasty: who is satisfied and who is not? Clin Orthop Relat Res 468(1):57\u201363. doi:\n                        10.1007\/s11999-009-1119-9","journal-title":"Clin Orthop Relat Res"},{"key":"1630_CR2","doi-asserted-by":"publisher","unstructured":"Akbari Shandiz M, Boulos P, Saevarsson SK, Yoo S, Miller S, Anglin C (2016) Changes in knee kinematics following total knee arthroplasty. Proc Inst Mech Eng H 230(4):265\u2013278. doi:\n                        10.1177\/0954411916632491","DOI":"10.1177\/0954411916632491"},{"key":"1630_CR3","unstructured":"Akbari Shandiz M (2015) Component placement in hip and knee replacement surgery: device development, imaging and biomechanics. PhD thesis, University of Calgary"},{"issue":"1","key":"1630_CR4","doi-asserted-by":"publisher","first-page":"172","DOI":"10.1007\/s11999-011-2089-2","volume":"470","author":"M Mahfouz","year":"2012","unstructured":"Mahfouz M, Abdel Fatah EE, Bowers LS, Scuderi G (2012) Three-dimensional morphology of the knee reveals ethnic differences. Clin Orthop Relat Res 470(1):172\u2013185. doi:\n                        10.1007\/s11999-011-2089-2","journal-title":"Clin Orthop Relat Res"},{"issue":"4","key":"1630_CR5","doi-asserted-by":"crossref","first-page":"294","DOI":"10.1055\/s-0030-1247766","volume":"22","author":"MR Mahfouz","year":"2009","unstructured":"Mahfouz MR, Abdel Fatah EE, Merkl BC, Mitchell JW (2009) Automatic and manual methodology for three-dimensional measurements of distal femoral gender differences and femoral component placement. J Knee Surg 22(4):294\u2013304","journal-title":"J Knee Surg"},{"key":"1630_CR6","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1097\/01.blo.0000238825.63648.1e","volume":"452","author":"PC Noble","year":"2006","unstructured":"Noble PC, Conditt MA, Cook KF, Mathis KB (2006) The John Insall award: patient expectations affect satisfaction with total knee arthroplasty. Clin Orthop Relat Res 452:35\u201343. doi:\n                        10.1097\/01.blo.0000238825.63648.1e","journal-title":"Clin Orthop Relat Res"},{"issue":"7 Suppl 3","key":"1630_CR7","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1016\/j.arth.2005.05.003","volume":"20","author":"SJ Kim","year":"2005","unstructured":"Kim SJ, MacDonald M, Hernandez J, Wixson RL (2005) Computer assisted navigation in total knee arthroplasty: improved coronal alignment. J Arthroplasty 20(7 Suppl 3):123\u2013131. doi:\n                        10.1016\/j.arth.2005.05.003","journal-title":"J Arthroplasty"},{"issue":"5","key":"1630_CR8","doi-asserted-by":"publisher","first-page":"938","DOI":"10.1016\/j.arth.2013.09.018","volume":"29","author":"BA Rebal","year":"2014","unstructured":"Rebal BA, Babatunde OM, Lee JH, Geller JA, Patrick DA Jr, Macaulay W (2014) Imageless computer navigation in total knee arthroplasty provides superior short term functional outcomes: a meta-analysis. J Arthroplasty 29(5):938\u2013944. doi:\n                        10.1016\/j.arth.2013.09.018","journal-title":"J Arthroplasty"},{"issue":"7","key":"1630_CR9","doi-asserted-by":"publisher","first-page":"907","DOI":"10.1302\/0301-620X.96B7.32812","volume":"96\u2013B","author":"HG Dossett","year":"2014","unstructured":"Dossett HG, Estrada NA, Swartz GJ, LeFevre GW, Kwasman BG (2014) A randomised controlled trial of kinematically and mechanically aligned total knee replacements: two-year clinical results. Bone Joint J 96\u2013B(7):907\u2013913. doi:\n                        10.1302\/0301-620X.96B7.32812","journal-title":"Bone Joint J"},{"key":"1630_CR10","first-page":"1","volume":"23","author":"H Lamecker","year":"2016","unstructured":"Lamecker H, Zachow S (2016) Statistical shape modeling of musculoskeletal structures and its applications. Comput Vis Biomech 23:1\u201323","journal-title":"Comput Vis Biomech"},{"issue":"3","key":"1630_CR11","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/S1361-8415(99)80020-6","volume":"3","author":"M Fleute","year":"1999","unstructured":"Fleute M, Lavallee S, Julliard R (1999) Incorporating a statistically based shape model into a system for computer-assisted anterior cruciate ligament surgery. Med Image Anal 3(3):209\u2013222","journal-title":"Med Image Anal"},{"issue":"5\u20136","key":"1630_CR12","doi-asserted-by":"publisher","first-page":"301","DOI":"10.3109\/10929080500389845","volume":"10","author":"N Perrin","year":"2005","unstructured":"Perrin N, Stindel E, Roux C (2005) BoneMorphing versus freehand localization of anatomical landmarks: consequences for the reproducibility of implant positioning in total knee arthroplasty. Comput Aided Surg 10(5\u20136):301\u2013309. doi:\n                        10.3109\/10929080500389845","journal-title":"Comput Aided Surg"},{"issue":"2","key":"1630_CR13","doi-asserted-by":"publisher","first-page":"99","DOI":"10.1016\/j.media.2006.05.001","volume":"11","author":"KT Rajamani","year":"2007","unstructured":"Rajamani KT, Styner MA, Talib H, Zheng G, Nolte LP, Gonzalez Ballester MA (2007) Statistical deformable bone models for robust 3D surface extrapolation from sparse data. Med Image Anal 11(2):99\u2013109. doi:\n                        10.1016\/j.media.2006.05.001","journal-title":"Med Image Anal"},{"key":"1630_CR14","doi-asserted-by":"publisher","unstructured":"Stindel E, Briard JL, Merloz P, Plaweski S, Dubrana F, Lefevre C, Troccaz J (2002) Bone morphing: 3D morphological data for total knee arthroplasty. Comput Aided Surg 7(3):156\u2013168. doi:\n                        10.1002\/igs.10042","DOI":"10.1002\/igs.10042"},{"issue":"6","key":"1630_CR15","doi-asserted-by":"publisher","first-page":"840","DOI":"10.1016\/j.media.2011.04.001","volume":"15","author":"N Baka","year":"2011","unstructured":"Baka N, Kaptein BL, de Bruijne M, van Walsum T, Giphart JE, Niessen WJ, Lelieveldt BP (2011) 2D\u20133D shape reconstruction of the distal femur from stereo X-ray imaging using statistical shape models. Med Image Anal 15(6):840\u2013850. doi:\n                        10.1016\/j.media.2011.04.001","journal-title":"Med Image Anal"},{"issue":"7","key":"1630_CR16","doi-asserted-by":"publisher","first-page":"721","DOI":"10.1080\/10255842.2013.843676","volume":"18","author":"TY Tsai","year":"2015","unstructured":"Tsai TY, Li JS, Wang S, Li P, Kwon YM, Li G (2015) Principal component analysis in construction of 3D human knee joint models using a statistical shape model method. Comput Methods Biomech Biomed Eng 18(7):721\u2013729. doi:\n                        10.1080\/10255842.2013.843676","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"Pt 2","key":"1630_CR17","first-page":"361","volume":"16","author":"I Hacihaliloghlu","year":"2013","unstructured":"Hacihaliloghlu I, Rasoulian A, Rohling RN, Abolmaesumi P (2013) Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features. Med Image Comput Comput Assist Interv 16(Pt 2):361\u2013368","journal-title":"Med Image Comput Comput Assist Interv"},{"key":"1630_CR18","unstructured":"Ehlke M, Heyland M, Mardian S, Duda GN, Zachow S (2015) 3D Assessment of Osteosynthesis based on 2D Radiographs. Paper presented at the Computer Assisted Orthopaedic Surgery Vancouver"},{"key":"1630_CR19","unstructured":"Amira for Research Partners (2017). \n                        https:\/\/amira.zib.de"},{"issue":"1\u20133","key":"1630_CR20","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3109\/10929081003647239","volume":"15","author":"R Elfring","year":"2010","unstructured":"Elfring R, de la Fuente M, Radermacher K (2010) Assessment of optical localizer accuracy for computer aided surgery systems. Comput Aided Surg 15(1\u20133):1\u201312. doi:\n                        10.3109\/10929081003647239","journal-title":"Comput Aided Surg"},{"key":"1630_CR21","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1109\/34.121791","volume":"14","author":"PJMN Besl","year":"1992","unstructured":"Besl PJMN (1992) A method for registration of 3D shapes. IEEE Trans Pattern Anal Mach Intell 14:239\u2013254","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1630_CR22","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/j.media.2017.02.005","volume":"38","author":"F Bernard","year":"2017","unstructured":"Bernard F, Salamanca L, Thunberg J, Tack A, Jentsch D, Lamecker H, Zachow S, Hertel F, Goncalves J, Gemmar P (2017) Shape-aware surface reconstruction from sparse 3D point-clouds. Med Image Anal 38:77\u201389","journal-title":"Med Image Anal"},{"key":"1630_CR23","unstructured":"Lamecker H (2008) Variational and statistical shape modeling for 3D geometry reconstruction (Dissertation). Freie Universitaet Berlin"},{"issue":"Pt 1","key":"1630_CR24","first-page":"119","volume":"11","author":"J Schmid","year":"2008","unstructured":"Schmid J, Magnenat-Thalmann N (2008) MRI bone segmentation using deformable models and shape priors. Med Image Comput Comput Assist Interv 11(Pt 1):119\u2013126","journal-title":"Med Image Comput Comput Assist Interv"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-017-1630-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1630-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1630-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,11,25]],"date-time":"2017-11-25T02:24:59Z","timestamp":1511576699000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-017-1630-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,29]]},"references-count":24,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2017,12]]}},"alternative-id":["1630"],"URL":"https:\/\/doi.org\/10.1007\/s11548-017-1630-5","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,29]]}}}