{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,13]],"date-time":"2026-05-13T04:09:47Z","timestamp":1778645387125,"version":"3.51.4"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T00:00:00Z","timestamp":1498262400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100002790","name":"Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100002790","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,11]]},"DOI":"10.1007\/s11548-017-1631-4","type":"journal-article","created":{"date-parts":[[2017,6,24]],"date-time":"2017-06-24T04:19:48Z","timestamp":1498277988000},"page":"1857-1866","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["CASPER: computer-aided segmentation of imperceptible motion\u2014a learning-based tracking of an invisible needle in ultrasound"],"prefix":"10.1007","volume":"12","author":[{"given":"Parmida","family":"Beigi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robert","family":"Rohling","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Septimiu E.","family":"Salcudean","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gary C.","family":"Ng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2017,6,24]]},"reference":[{"issue":"1","key":"1631_CR1","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1148\/radiology.174.1.2403684","volume":"174","author":"TA Matalon","year":"1990","unstructured":"Matalon TA, Silver B (1990) US guidance of interventional procedures. Radiology 174(1):43\u201347","journal-title":"Radiology"},{"issue":"6","key":"1631_CR2","first-page":"532","volume":"33","author":"Ki Jinn Chin","year":"2008","unstructured":"Chin Ki Jinn, Perlas Anahi, Chan Vincent W S, Brull Richard (2008) Needle visualization in ultrasound-guided regional anesthesia: challenges and solutions. Reg Anesthesia and Pain Med 33(6):532\u2013544","journal-title":"Reg Anesthesia and Pain Med"},{"issue":"8","key":"1631_CR3","doi-asserted-by":"crossref","first-page":"1828","DOI":"10.1007\/s10439-014-1208-0","volume":"43","author":"E Ayvali","year":"2015","unstructured":"Ayvali E, Desai JP (2015) Optical flow-based tracking of needles and needle-tip localization using circular hough transform in ultrasound images. Ann Biomed Eng 43(8):1828\u20131840","journal-title":"Ann Biomed Eng"},{"issue":"8","key":"1631_CR4","doi-asserted-by":"crossref","first-page":"1907","DOI":"10.1109\/TBME.2010.2046416","volume":"57","author":"M Uhercik","year":"2010","unstructured":"Uhercik M, Kybic J, Liebgott H, Cachard C (2010) Model fitting using ransac for surgical tool localization in 3D ultrasound images. IEEE Trans Biomed Eng 57(8):1907\u20131916","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"1631_CR5","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1177\/0161734613502004","volume":"35","author":"Y Zhao","year":"2013","unstructured":"Zhao Y, Cachard C, Liebgott H (2013) Automatic needle detection and tracking in 3d ultrasound using an ROI-based RANSAC and Kalman method. Ultrasonic imaging 35(4):283\u2013306","journal-title":"Ultrasonic imaging"},{"issue":"5","key":"1631_CR6","first-page":"193","volume":"9","author":"M Ding","year":"2004","unstructured":"Ding M, Fenster A (2004) Projection-based needle segmentation in 3D ultrasound images. Comput aided surg : int Soc Comput Aided Surg 9(5):193\u2013201","journal-title":"Comput aided surg : int Soc Comput Aided Surg"},{"issue":"4","key":"1631_CR7","doi-asserted-by":"crossref","first-page":"804","DOI":"10.1016\/j.ultrasmedbio.2013.11.004","volume":"40","author":"Q Wu","year":"2014","unstructured":"Wu Q, Yuchi M, Ding M (2014) Phase grouping-based needle segmentation in 3d trans-rectal ultrasound-guided prostate trans-perineal therapy. Ultrasound in Med Biol 40(4):804\u2013816","journal-title":"Ultrasound in Med Biol"},{"issue":"7","key":"1631_CR8","doi-asserted-by":"crossref","first-page":"2057","DOI":"10.1016\/j.ultrasmedbio.2015.03.013","volume":"41","author":"P Beigi","year":"2015","unstructured":"Beigi P, Salcudean T, Rohling RN, Lessoway VA, Ng GC (2015) Needle trajectory and tip localization in 3D ultrasound using a moving stylus. Ultrasound in Med Biol 41(7):2057\u20132070","journal-title":"Ultrasound in Med Biol"},{"key":"1631_CR9","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.ultras.2016.09.006","volume":"73","author":"Y Zhao","year":"2017","unstructured":"Zhao Y, Shen Y, Bernard A, Cachard C, Liebgott H (2017) Evaluation and comparison of current biopsy needle localization and tracking methods using 3D ultrasound. Ultrasonics 73:206\u2013220","journal-title":"Ultrasonics"},{"issue":"12","key":"1631_CR10","doi-asserted-by":"crossref","first-page":"2899","DOI":"10.1109\/TBME.2014.2334309","volume":"61","author":"TK Adebar","year":"2014","unstructured":"Adebar TK, Fletcher AE, Okamura AM (2014) 3D ultrasound-guided robotic needle steering in biological tissue. IEEE Trans Biomed Eng 61(12):2899\u20132910","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"1631_CR11","doi-asserted-by":"crossref","first-page":"898","DOI":"10.1007\/s00270-011-0278-8","volume":"35","author":"A Hakime","year":"2012","unstructured":"Hakime A, Deschamps F, De Carvalho EGM, Barah A, Auperin A, De Baere T (2012) Electromagnetic-tracked biopsy under ultrasound guidance: preliminary results. Cardiovasc interv radiol 35(4):898\u2013905","journal-title":"Cardiovasc interv radiol"},{"issue":"1","key":"1631_CR12","doi-asserted-by":"crossref","first-page":"143","DOI":"10.7863\/jum.2013.32.1.143","volume":"32","author":"HP Sviggum","year":"2013","unstructured":"Sviggum HP, Ahn K, Dilger JA, Smith HM (2013) Needle echogenicity in sonographically guided regional anesthesia: blinded comparison of 4 enhanced needles and validation of visual criteria for evaluation. J Ultrasound in Med 32(1):143\u2013148","journal-title":"J Ultrasound in Med"},{"issue":"6","key":"1631_CR13","doi-asserted-by":"crossref","first-page":"1728","DOI":"10.1109\/TBME.2013.2241430","volume":"60","author":"C Kim","year":"2013","unstructured":"Kim C, Chang D, Petrisor D, Chirikjian G, Han M, Stoianovici D (2013) Ultrasound probe and needle-guide calibration for robotic ultrasound scanning and needle targeting. IEEE Trans Biomed Eng 60(6):1728\u20131734","journal-title":"IEEE Trans Biomed Eng"},{"key":"1631_CR14","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1007\/978-1-4419-1126-1_23","volume-title":"Surgical robotics","author":"NJ Cowan","year":"2011","unstructured":"Cowan NJ, Goldberg K, Chirikjian GS, Fichtinger G, Alterovitz R, Reed KB, Kallem V, Park W, Misra S, Okamura AM (2011) Robotic needle steering: Design, modeling, planning, and image guidance. Surgical robotics. Springer, New York, pp 557\u2013582"},{"issue":"2","key":"1631_CR15","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1002\/rcs.184","volume":"4","author":"EM Boctor","year":"2008","unstructured":"Boctor EM, Choti MA, Burdette EC, Webster RJ (2008) Three-dimensional ultrasound-guided robotic needle placement: an experimental evaluation. Int J Med Robot Comput Assist Surg 4(2):180\u201391","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"5","key":"1631_CR16","doi-asserted-by":"crossref","first-page":"617","DOI":"10.1016\/j.ultrasmedbio.2004.02.001","volume":"30","author":"Cheung Stephanie","year":"2004","unstructured":"Stephanie Cheung, Robert Rohling (2004) Enhancement of needle visibility in ultrasound-guided percutaneous procedures. Ultrasound in Med Biol 30(5):617\u2013624","journal-title":"Ultrasound in Med Biol"},{"key":"1631_CR17","doi-asserted-by":"crossref","unstructured":"Beigi P, Salcudean T, Rohling RN, Lessoway VA, Ng GC (2016) Automatic detection of a hand-held needle in ultrasound via phased-based analysis of the tremor motion. In: SPIE medical imaging, pp 97860I-1\u201397860I-6","DOI":"10.1117\/12.2217073"},{"issue":"6","key":"1631_CR18","doi-asserted-by":"crossref","first-page":"1183","DOI":"10.1007\/s11548-016-1402-7","volume":"11","author":"P Beigi","year":"2016","unstructured":"Beigi P, Salcudean T, Rohling RN, Ng GC (2016) Spectral analysis of the tremor motion for needle detection in curvilinear ultrasound via spatio-temporal linear sampling. Int J Comput Assist Radiol Surg 11(6):1183\u20131192","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1631_CR19","first-page":"409","volume":"13","author":"T Poggio","year":"2001","unstructured":"Poggio T, Cauwenberghs G (2001) Incremental and decremental support vector machine learning. Adv neural inform process syst 13:409","journal-title":"Adv neural inform process syst"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-017-1631-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1631-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1631-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,9,26]],"date-time":"2019-09-26T20:07:54Z","timestamp":1569528474000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-017-1631-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,24]]},"references-count":19,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["1631"],"URL":"https:\/\/doi.org\/10.1007\/s11548-017-1631-4","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,6,24]]}}}