{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,22]],"date-time":"2025-10-22T10:37:16Z","timestamp":1761129436198,"version":"3.37.3"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2017,6,29]],"date-time":"2017-06-29T00:00:00Z","timestamp":1498694400000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["61361160417","81271735"],"award-info":[{"award-number":["61361160417","81271735"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Key Technology R&D Program of China","award":["2016YFC0105800"],"award-info":[{"award-number":["2016YFC0105800"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,8]]},"DOI":"10.1007\/s11548-017-1634-1","type":"journal-article","created":{"date-parts":[[2017,6,29]],"date-time":"2017-06-29T15:50:42Z","timestamp":1498751442000},"page":"1355-1368","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":25,"title":["A surgical robot with augmented reality visualization for stereoelectroencephalography electrode implantation"],"prefix":"10.1007","volume":"12","author":[{"given":"Bowei","family":"Zeng","sequence":"first","affiliation":[]},{"given":"Fanle","family":"Meng","sequence":"additional","affiliation":[]},{"given":"Hui","family":"Ding","sequence":"additional","affiliation":[]},{"given":"Guangzhi","family":"Wang","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,6,29]]},"reference":[{"issue":"3","key":"1634_CR1","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1227\/NEU.0b013e31827d1161","volume":"72","author":"F Cardinale","year":"2013","unstructured":"Cardinale F, Cossu M, Castana L, Casaceli G, Schiariti MP, Miserocchi A, Fuschillo D, Moscato A, Caborni C, Arnulfo G (2013) Stereoelectroencephalography: surgical methodology, safety, and stereotactic application accuracy in 500 procedures. Neurosurgery 72(3):353\u2013366","journal-title":"Neurosurgery"},{"issue":"6","key":"1634_CR2","doi-asserted-by":"crossref","first-page":"1358","DOI":"10.3171\/2014.12.JNS141968","volume":"123","author":"M Cossu","year":"2015","unstructured":"Cossu M, Fuschillo D, Casaceli G, Pelliccia V, Castana L, Mai R, Francione S, Sartori I, Gozzo F, Nobili L (2015) Stereoelectroencephalography-guided radiofrequency thermocoagulation in the epileptogenic zone: a retrospective study on 89 cases. J Neurosurg 123(6):1358\u20131367","journal-title":"J Neurosurg"},{"issue":"4","key":"1634_CR3","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1227\/NEU.0000000000000544","volume":"10","author":"M Nowell","year":"2014","unstructured":"Nowell M, Rodionov R, Diehl B, Wehner T, Zombori G, Kinghorn J, Ourselin S, Duncan J, Miserocchi A, McEvoy A (2014) A novel method for implementation of frameless StereoEEG in epilepsy surgery. Neurosurgery 10(4):525","journal-title":"Neurosurgery"},{"key":"1634_CR4","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1109\/RBME.2015.2428305","volume":"8","author":"C Faria","year":"2015","unstructured":"Faria C, Erlhagen W, Rito M, De Momi E, Ferrigno G, Bicho E (2015) Review of robotic technology for stereotactic neurosurgery. IEEE Rev Biomed Eng 8:125\u2013137","journal-title":"IEEE Rev Biomed Eng"},{"key":"1634_CR5","doi-asserted-by":"publisher","unstructured":"Tagaytayan R, Kelemen A, Sik-Lanyi C (2016) Augmented reality in neurosurgery. Arch Med Sci. doi:\n                        10.5114\/aoms.2016.58690","DOI":"10.5114\/aoms.2016.58690"},{"issue":"1","key":"1634_CR6","doi-asserted-by":"crossref","first-page":"206","DOI":"10.3171\/2014.9.JNS141001","volume":"123","author":"L Besharati Tabrizi","year":"2015","unstructured":"Besharati Tabrizi L, Mahvash M (2015) Augmented reality-guided neurosurgery: accuracy and intraoperative application of an image projection technique. J Neurosurg 123(1):206\u2013211","journal-title":"J Neurosurg"},{"key":"1634_CR7","doi-asserted-by":"publisher","unstructured":"Meola A, Cutolo F, Carbone M, Cagnazzo F, Ferrari M, Ferrari V (2016) Augmented reality in neurosurgery: a systematic review. Neurosurg Rev. doi:\n                        10.1007\/s10143-016-0732-9","DOI":"10.1007\/s10143-016-0732-9"},{"issue":"11","key":"1634_CR8","doi-asserted-by":"crossref","first-page":"1823","DOI":"10.1007\/s11548-015-1163-8","volume":"10","author":"M Kersten-Oertel","year":"2015","unstructured":"Kersten-Oertel M, Gerard I, Drouin S, Mok K, Sirhan D, Sinclair DS, Collins DL (2015) Augmented reality in neurovascular surgery: feasibility and first uses in the operating room. Int J Comput Assist Radiol Surg 10(11):1823\u20131836","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"1634_CR9","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1227\/NEU.0000000000001034","volume":"78","author":"J Gonz\u00e1lez-Mart\u00ednez","year":"2016","unstructured":"Gonz\u00e1lez-Mart\u00ednez J, Bulacio J, Thompson S, Gale J, Smithason S, Najm I, Bingaman W (2016) Technique, results, and complications related to robot-assisted stereoelectroencephalography. Neurosurgery 78(2):169\u2013180","journal-title":"Neurosurgery"},{"key":"1634_CR10","doi-asserted-by":"crossref","first-page":"399","DOI":"10.1016\/j.wneu.2015.11.084","volume":"87","author":"E Watanabe","year":"2016","unstructured":"Watanabe E, Satoh M, Konno T, Hirai M, Yamaguchi T (2016) The trans-visible navigator: a see-through neuronavigation system using augmented reality. World Neurosurg 87:399\u2013405","journal-title":"World Neurosurg"},{"issue":"4","key":"1634_CR11","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1227\/01.NEU.0000349918.36700.1C","volume":"65","author":"RA Kockro","year":"2009","unstructured":"Kockro RA, Tsai YT, Ng I, Hwang P, Zhu C, Agusanto K, Hong LX, Serra L (2009) DEX - RAY: augmented reality neurosurgical navigation with a handheld video probe. Neurosurgery 65(4):795\u2013808","journal-title":"Neurosurgery"},{"key":"1634_CR12","unstructured":"Park H, Kang G-C, Lee M-H, Kim S-J, Park J-I (2005) Direct-projected augmented reality considering user\u2019s viewpoint. In: Proceedings of international meeting on information display and exhibition, pp 748\u2013751"},{"issue":"3","key":"1634_CR13","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/j.suronc.2011.07.002","volume":"20","author":"S Nicolau","year":"2011","unstructured":"Nicolau S, Soler L, Mutter D, Marescaux J (2011) Augmented reality in laparoscopic surgical oncology. Surg Oncol 20(3):189\u2013201","journal-title":"Surg Oncol"},{"key":"1634_CR14","doi-asserted-by":"crossref","unstructured":"Hennersperger C, Manus J, Navab N (2016) Mobile laserprojection in computer assisted neurosurgery. In: International conference on medical imaging and virtual reality. Springer, pp 151\u2013162","DOI":"10.1007\/978-3-319-43775-0_14"},{"issue":"2","key":"1634_CR15","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1364\/AOP.3.000128","volume":"3","author":"J Geng","year":"2011","unstructured":"Geng J (2011) Structured-light 3D surface imaging: a tutorial. Adv Opt Phot 3(2):128\u2013160","journal-title":"Adv Opt Phot"},{"key":"1634_CR16","volume-title":"Multiple view geometry in computer vision","author":"R Hartley","year":"2003","unstructured":"Hartley R, Zisserman A (2003) Multiple view geometry in computer vision. Cambridge University Press, Cambridge"},{"key":"1634_CR17","doi-asserted-by":"crossref","unstructured":"Moreno D, Taubin G (2012) Simple, accurate, and robust projector-camera calibration. In: 2012 Second international conference on 3D imaging, modeling, processing, visualization & transmission. IEEE, pp 464\u2013471","DOI":"10.1109\/3DIMPVT.2012.77"},{"issue":"3","key":"1634_CR18","doi-asserted-by":"crossref","first-page":"345","DOI":"10.1109\/70.34770","volume":"5","author":"RY Tsai","year":"1989","unstructured":"Tsai RY, Lenz RK (1989) A new technique for fully autonomous and efficient 3D robotics hand\/eye calibration. IEEE Trans on Robot Autom 5(3):345\u2013358","journal-title":"IEEE Trans on Robot Autom"},{"issue":"11","key":"1634_CR19","doi-asserted-by":"crossref","first-page":"1330","DOI":"10.1109\/34.888718","volume":"22","author":"Z Zhang","year":"2000","unstructured":"Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Patt Anal Mach Intell 22(11):1330\u20131334","journal-title":"IEEE Trans Patt Anal Mach Intell"},{"key":"1634_CR20","unstructured":"Besl PJ, McKay ND (1992) Method for registration of 3-D shapes. In: Robotics-DL tentative. International society for optics and photonics, pp 586\u2013606"},{"key":"1634_CR21","doi-asserted-by":"crossref","unstructured":"Rusinkiewicz S, Levoy M (2001) Efficient variants of the ICP algorithm. In: 3-D Digital imaging and modeling. Proceedings. Third international conference on, 2001. IEEE, pp 145\u2013152","DOI":"10.1109\/IM.2001.924423"},{"key":"1634_CR22","doi-asserted-by":"crossref","unstructured":"Sielhorst T, Bichlmeier C, Heining SM, Navab N (2006) Depth perception\u2014a major issue in medical AR: evaluation study by twenty surgeons. In: International conference on medical image computing and computer-assisted intervention. Springer, pp 364\u2013372","DOI":"10.1007\/11866565_45"},{"key":"1634_CR23","unstructured":"Cheng O, Guangzhi W, Quan Z, Wei K, Hui D (2005) Evaluating harris method in camera calibration. In: Engineering in medicine and biology society. IEEE-EMBS 2005. 27th annual international conference of the. IEEE, pp 6383\u20136386"},{"key":"1634_CR24","doi-asserted-by":"crossref","unstructured":"Zhu C, Liang X, Kockro R, Serra L (2004) Accuracy evaluation of an augmented reality enhanced surgical navigation system. In: International congress series. Elsevier, p 1329","DOI":"10.1016\/j.ics.2004.03.140"},{"key":"1634_CR25","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1016\/j.wneu.2016.06.114","volume":"94","author":"K Roessler","year":"2016","unstructured":"Roessler K, Sommer B, Merkel A, Rampp S, Gollwitzer S, Hamer HM, Buchfelder M (2016) A frameless stereotactic implantation technique for depth electrodes in refractory epilepsy using intraoperative magnetic resonance imaging. World Neurosurg 94:206\u2013210","journal-title":"World Neurosurg"},{"key":"1634_CR26","doi-asserted-by":"crossref","unstructured":"Vakharia VN, Sparks R, O\u2019Keeffe AG, Rodionov R, Miserocchi A, McEvoy A, Ourselin S, Duncan J (2017) Accuracy of intracranial electrode placement for stereoelectroencephalography: A systematic review and meta-analysis. Epilepsia 58(6):921\u2013932","DOI":"10.1111\/epi.13713"},{"issue":"3","key":"1634_CR27","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1016\/j.ijrobp.2007.10.048","volume":"70","author":"R Krempien","year":"2008","unstructured":"Krempien R, Hoppe H, Kahrs L, Daeuber S, Schorr O, Eggers G, Bischof M, Munter MW, Debus J, Harms W (2008) Projector-based augmented reality for intuitive intraoperative guidance in image-guided 3D interstitial brachytherapy. Int J Radiat Oncol BiolPhys 70(3):944\u2013952","journal-title":"Int J Radiat Oncol BiolPhys"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-017-1634-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1634-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1634-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2017,8,2]],"date-time":"2017-08-02T10:36:03Z","timestamp":1501670163000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-017-1634-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,6,29]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2017,8]]}},"alternative-id":["1634"],"URL":"https:\/\/doi.org\/10.1007\/s11548-017-1634-1","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2017,6,29]]}}}