{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T06:09:52Z","timestamp":1760249392159,"version":"3.37.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2017,7,13]],"date-time":"2017-07-13T00:00:00Z","timestamp":1499904000000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100003150","name":"Fonds Qu\u00e9b\u00e9cois de la Recherche sur la Nature et les Technologies","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003150","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2017,11]]},"DOI":"10.1007\/s11548-017-1639-9","type":"journal-article","created":{"date-parts":[[2017,7,13]],"date-time":"2017-07-13T16:52:48Z","timestamp":1499964768000},"page":"1867-1876","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Automatic evaluation of vessel diameter variation from 2D X-ray angiography"],"prefix":"10.1007","volume":"12","author":[{"given":"Faten","family":"M\u2019hiri","sequence":"first","affiliation":[]},{"given":"Luc","family":"Duong","sequence":"additional","affiliation":[]},{"given":"Christian","family":"Desrosiers","sequence":"additional","affiliation":[]},{"given":"Nagib","family":"Dahdah","sequence":"additional","affiliation":[]},{"given":"Joaquim","family":"Mir\u00f3","sequence":"additional","affiliation":[]},{"given":"Mohamed","family":"Cheriet","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2017,7,13]]},"reference":[{"issue":"11","key":"1639_CR1","doi-asserted-by":"crossref","first-page":"2274","DOI":"10.1109\/TPAMI.2012.120","volume":"34","author":"R Achanta","year":"2012","unstructured":"Achanta R, Shaji A, Smith K, Lucchi A, Fua P, Susstrunk S (2012) Slic superpixels compared to state-of-the-art superpixel methods. IEEE Trans Pattern Anal Mach Intell 34(11):2274\u20132282","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"2","key":"1639_CR2","doi-asserted-by":"crossref","first-page":"119","DOI":"10.1016\/j.jcct.2010.01.007","volume":"4","author":"N Ahmadi","year":"2010","unstructured":"Ahmadi N, Shavelle D, Nabavi V, Hajsadeghi F, Moshrefi S, Flores F, Azmoon S, Mao SS, Ebrahimi R, Budoff M (2010) Coronary distensibility index measured by computed tomography is associated with the severity of coronary artery disease. J Cardiovasc Comput Tomogr 4(2):119\u2013126","journal-title":"J Cardiovasc Comput Tomogr"},{"issue":"Suppl 2","key":"1639_CR3","doi-asserted-by":"crossref","first-page":"A153","DOI":"10.1161\/circ.131.suppl_2.153","volume":"131","author":"M Benovoy","year":"2015","unstructured":"Benovoy M, Cheriet F, Maurice RL, Dahdah N (2015) Automated angiographic assessment of coronary artery vasomotion in Kawasaki disease patients. Circulation 131(Suppl 2):A153\u2013A153","journal-title":"Circulation"},{"issue":"13\u2013S","key":"1639_CR4","doi-asserted-by":"crossref","first-page":"1672","DOI":"10.1016\/S0735-1097(16)31673-4","volume":"67","author":"M Benovoy","year":"2016","unstructured":"Benovoy M, Dionne A, Cheriet F, Maurice RL, Dahdah N (2016) Correlation between automatic angio-based coronary artery stiffness assessment and visual OCT pathology scoring. J Am Coll Cardiol 67(13\u2013S):1672\u20131672","journal-title":"J Am Coll Cardiol"},{"issue":"3","key":"1639_CR5","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1016\/j.media.2004.06.026","volume":"9","author":"S Bouix","year":"2005","unstructured":"Bouix S, Siddiqi K, Tannenbaum A (2005) Flux driven automatic centerline extraction. Med Image Anal 9(3):209\u2013221","journal-title":"Med Image Anal"},{"issue":"4","key":"1639_CR6","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1136\/adc.87.4.348","volume":"87","author":"Y Cheung","year":"2002","unstructured":"Cheung Y, Brogan P, Pilla C, Dillon M, Redington A (2002) Arterial distensibility in children and teenagers: normal evolution and the effect of childhood vasculitis. Arch Dis Child 87(4):348\u2013351","journal-title":"Arch Dis Child"},{"key":"1639_CR7","doi-asserted-by":"crossref","unstructured":"Compas C, Syeda-Mahmood T, McNeillie P, Beymer D (2014) Automatic detection of coronary stenosis in x-ray angiography through spatio-temporal tracking. In: 2014 IEEE 11th international symposium on biomedical imaging (ISBI), pp 1299\u20131302","DOI":"10.1109\/ISBI.2014.6868115"},{"key":"1639_CR8","doi-asserted-by":"crossref","unstructured":"Frangi A, Niessen W, Vincken K, Viergever M (1998) Multiscale vessel enhancement filtering. In: Medical image computing and computer-assisted interventation MICCAI98, p 130","DOI":"10.1007\/BFb0056195"},{"issue":"12","key":"1639_CR9","doi-asserted-by":"crossref","first-page":"1451","DOI":"10.4244\/EIJV8I12A219","volume":"8","author":"C Girasis","year":"2013","unstructured":"Girasis C, Schuurbiers J, Muramatsu T, Aben JP, Onuma Y, Soekhradj S, Morel M, van Geuns RJ, Wentzel JJ, Serruys PW (2013) Advanced three-dimensional quantitative coronary angiographic assessment of bifurcation lesions: methodology and phantom validation. EuroIntervention 8(12):1451\u20131460","journal-title":"EuroIntervention"},{"key":"1639_CR10","doi-asserted-by":"crossref","first-page":"453","DOI":"10.1007\/0-387-28831-7_28","volume-title":"Handbook of mathematical models in computer vision","author":"L Grady","year":"2006","unstructured":"Grady L, Sun V, Williams J (2006) Interactive graph-based segmentation methods in Cardiovascular imaging. In: Paragios N, Chen Y, Faugeras O (eds) Handbook of mathematical models in computer vision. Springer, Boston, MA, pp 453\u2013469"},{"issue":"1","key":"1639_CR11","doi-asserted-by":"crossref","first-page":"61","DOI":"10.1002\/ccd.1810330116","volume":"33","author":"E Gronenschild","year":"1994","unstructured":"Gronenschild E, Janssen J, Tijdens F (1994) CAAS II: a second generation system for off-line and on-line quantitative coronary angiography. Catheter Cardiovasc Diagn 33(1):61\u201375","journal-title":"Catheter Cardiovasc Diagn"},{"key":"1639_CR12","doi-asserted-by":"crossref","unstructured":"Hadida J, Desrosiers C, Duong L (2012) Stochastic 3D motion compensation of coronary arteries from monoplane angiograms. In: Medical image computing and computer-assisted intervention\u2013MICCAI 2012. Springer, pp 651\u2013658","DOI":"10.1007\/978-3-642-33415-3_80"},{"issue":"4","key":"1639_CR13","doi-asserted-by":"crossref","first-page":"491","DOI":"10.1016\/j.amjcard.2011.03.078","volume":"108","author":"S Kelle","year":"2011","unstructured":"Kelle S, Hays AG, Hirsch GA, Gerstenblith G, Miller JM, Steinberg AM, Sch M, Texter JH, Wellnhofer E, Weiss RG, Stuber M (2011) Coronary artery distensibility assessed by 3.0 tesla coronary magnetic resonance imaging in subjects with and without coronary artery disease. Am J Cardiol 108(4):491\u2013497","journal-title":"Am J Cardiol"},{"key":"1639_CR14","doi-asserted-by":"crossref","unstructured":"Kroon DJ, Slump C, Maal T (2010) Optimized anisotropic rotational invariant diffusion scheme on cone-beam CT. In: Jiang T, Navab N, Pluim J, Viergever M (eds) Medical image computing and computer-assisted intervention MICCAI 2010. Lecture notes in computer science, vol 6363. Springer, Berlin, pp 221\u2013228","DOI":"10.1007\/978-3-642-15711-0_28"},{"key":"1639_CR15","doi-asserted-by":"crossref","unstructured":"Lesage D, Angelini E, Bloch I, Funka-Lea G (2009) A review of 3D vessel lumen segmentation techniques: models, features and extraction schemes. Med Image Anal 13(6):819\u2013845 (Includes special section on computational biomechanics for medicine)","DOI":"10.1016\/j.media.2009.07.011"},{"issue":"5","key":"1639_CR16","doi-asserted-by":"crossref","first-page":"864","DOI":"10.1016\/j.ultrasmedbio.2013.11.013","volume":"40","author":"RL Maurice","year":"2014","unstructured":"Maurice RL, Vaujois L, Dahdah N, Chibab N, Maurice A, Nuyt AM, L\u00e9vy \u00c9, Bigras JL (2014) Carotid wall elastography to assess midterm vascular dysfunction secondary to intrauterine growth restriction: feasibility and comparison with standardized intima-media thickness. Ultrasound Med Biol 40(5):864\u2013870","journal-title":"Ultrasound Med Biol"},{"key":"1639_CR17","unstructured":"Medis: Qangio xa. URL http:\/\/www.medis.nl\/Products\/QAngioXA"},{"key":"1639_CR18","doi-asserted-by":"crossref","unstructured":"M\u2019hiri F, Duong L, Desrosiers C, Cheriet M (2013) Vessel Walker: coronary arteries segmentation using random walks and hessian-based vesselness filter. In: ISBI, pp 918\u2013921","DOI":"10.1109\/ISBI.2013.6556625"},{"key":"1639_CR19","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1016\/j.compbiomed.2016.10.001","volume":"79","author":"F M\u2019hiri","year":"2016","unstructured":"M\u2019hiri F, Duong L, Desrosiers C, Leye M, Mir\u00f3 J, Cheriet M (2016) A graph-based approach for spatio-temporal segmentation of coronary arteries in x-ray angiographic sequences. Comput Biol Med 79:45\u201358","journal-title":"Comput Biol Med"},{"key":"1639_CR20","doi-asserted-by":"crossref","unstructured":"Mirzaalian H, Hamarneh G (2010) Vessel scale-selection using MRF optimization. In: 2010 IEEE conference on computer vision and pattern recognition (CVPR). IEEE, pp 3273\u20133279","DOI":"10.1109\/CVPR.2010.5540051"},{"issue":"1","key":"1639_CR21","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1109\/TSMC.1979.4310076","volume":"9","author":"N Otsu","year":"1979","unstructured":"Otsu N (1979) A threshold selection method from gray-level histograms. IEEE Trans Syst Man Cybern 9(1):62\u201366","journal-title":"IEEE Trans Syst Man Cybern"},{"key":"1639_CR22","unstructured":"PIEMedical: Caas. http:\/\/www.piemedicalimaging.com\/partner\/caas\/"},{"issue":"12","key":"1639_CR23","doi-asserted-by":"crossref","first-page":"1954","DOI":"10.1109\/JPROC.2009.2022417","volume":"97","author":"WP Segars","year":"2009","unstructured":"Segars WP, Tsui BM (2009) MCAT to XCAT: the evolution of 4-D computerized phantoms for imaging research. Proc IEEE 97(12):1954\u20131968","journal-title":"Proc IEEE"},{"issue":"8","key":"1639_CR24","doi-asserted-by":"crossref","first-page":"1847","DOI":"10.1007\/s10554-013-0271-1","volume":"29","author":"R Shahzad","year":"2013","unstructured":"Shahzad R, Kiri\u015fli H, Metz C, Tang H, Schaap M, van Vliet L, Niessen W, van Walsum T (2013) Automatic segmentation, detection and quantification of coronary artery stenoses on cta. Int J Cardiovasc Imaging 29(8):1847\u20131859","journal-title":"Int J Cardiovasc Imaging"},{"issue":"8","key":"1639_CR25","doi-asserted-by":"crossref","first-page":"1046","DOI":"10.1109\/TMI.2004.828676","volume":"23","author":"G Shechter","year":"2004","unstructured":"Shechter G, Ozturk C, Resar JR, McVeigh ER (2004) Respiratory motion of the heart from free breathing coronary angiograms. IEEE Trans Med Imaging 23(8):1046\u20131056","journal-title":"IEEE Trans Med Imaging"},{"key":"1639_CR26","unstructured":"Tomasello SD, Costanzo L, Galassi AR (2011) Quantitative coronary angiography in the interventional cardiology. In: Kirac SF (ed) Advances in the diagnosis of coronary atherosclerosis, InTech, pp 255\u2013272"},{"issue":"12","key":"1639_CR27","doi-asserted-by":"crossref","first-page":"1388","DOI":"10.1016\/j.echo.2013.08.022","volume":"26","author":"L Vaujois","year":"2013","unstructured":"Vaujois L, Dallaire F, Maurice RL, Fournier A, Houde C, Th\u00e9rien J, Cartwright D, Dahdah N (2013) The biophysical properties of the aorta are altered following Kawasaki disease. J Am Soc Echocardiogr 26(12):1388\u20131396","journal-title":"J Am Soc Echocardiogr"},{"key":"1639_CR28","volume-title":"Anisotropic diffusion in image processing","author":"J Weickert","year":"1998","unstructured":"Weickert J (1998) Anisotropic diffusion in image processing, vol 256. Citeseer, Rijeka"},{"issue":"4","key":"1639_CR29","first-page":"1971","volume":"9","author":"M Zhao","year":"2015","unstructured":"Zhao M, Lin HY, Yang CH, Hsu CY, Pan JS, Lin MJ (2015) Automatic threshold level set model applied on MRI image segmentation of brain tissue. Appl Math 9(4):1971\u20131980","journal-title":"Appl Math"},{"key":"1639_CR30","doi-asserted-by":"crossref","unstructured":"Zhu N, Chung AC (2013) Random walks with adaptive cylinder flux based connectivity for vessel segmentation. In: Medical image computing and computer-assisted intervention\u2013MICCAI 2013. Springer, pp 550\u2013558","DOI":"10.1007\/978-3-642-40763-5_68"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-017-1639-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1639-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1639-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,7,30]],"date-time":"2022-07-30T22:59:44Z","timestamp":1659221984000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-017-1639-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,7,13]]},"references-count":30,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2017,11]]}},"alternative-id":["1639"],"URL":"https:\/\/doi.org\/10.1007\/s11548-017-1639-9","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2017,7,13]]}}}