{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:52:05Z","timestamp":1786981925086,"version":"build-2736575974"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2017,8,1]],"date-time":"2017-08-01T00:00:00Z","timestamp":1501545600000},"content-version":"unspecified","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Canon USA Inc."},{"DOI":"10.13039\/100000009","name":"Foundation for the National Institutes of Health","doi-asserted-by":"publisher","award":["P41EB015898"],"award-info":[{"award-number":["P41EB015898"]}],"id":[{"id":"10.13039\/100000009","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2018,1]]},"DOI":"10.1007\/s11548-017-1644-z","type":"journal-article","created":{"date-parts":[[2017,8,1]],"date-time":"2017-08-01T01:49:05Z","timestamp":1501552145000},"page":"125-133","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Using needle orientation sensing as surrogate signal for respiratory motion estimation in percutaneous interventions"],"prefix":"10.1007","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1857-5921","authenticated-orcid":false,"given":"Momen","family":"Abayazid","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahisa","family":"Kato","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Stuart G.","family":"Silverman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nobuhiko","family":"Hata","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2017,8,1]]},"reference":[{"issue":"4","key":"1644_CR1","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1016\/j.medengphy.2006.07.003","volume":"29","author":"N Abolhassani","year":"2007","unstructured":"Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29(4):413\u2013431","journal-title":"Med Eng Phys"},{"issue":"9","key":"1644_CR2","doi-asserted-by":"crossref","first-page":"1166","DOI":"10.1111\/j.1478-3231.2007.01592.x","volume":"27","author":"B Al-Knawy","year":"2007","unstructured":"Al-Knawy B, Shiffman M (2007) Percutaneous liver biopsy in clinical practice. Liver Int 27(9):1166\u20131173","journal-title":"Liver Int"},{"key":"1644_CR3","doi-asserted-by":"crossref","unstructured":"Alterovitz R, Pouliot J, Taschereau R, Hsu ICJ, Goldberg K (2003) Simulating needle insertion and radioactive seed implantation for prostate brachytherapy. In: Westwood JD, Hoffman HM, Mogel GT, Phillips R, Robb RA, Stredney D (eds) Studies in health technology and informatics, vol 94. IOS Press, pp 19\u201325.","DOI":"10.3233\/978-1-60750-938-7-19"},{"issue":"3","key":"1644_CR4","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1016\/j.ijrobp.2004.11.009","volume":"61","author":"JM Balter","year":"2005","unstructured":"Balter JM, Wright JN, Newell LJ, Friemel B, Dimmer S, Cheng Y, Wong J, Vertatschitsch E, Mate TP (2005) Accuracy of a wireless localization system for radiotherapy. Int J Radiat Oncol Biol Phys 61(3):933\u2013937","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"5","key":"1644_CR5","doi-asserted-by":"crossref","first-page":"1359","DOI":"10.1088\/0031-9155\/57\/5\/1359","volume":"57","author":"MAL Bell","year":"2012","unstructured":"Bell MAL, Byram BC, Harris EJ, Evans PM, Bamber JC (2012) In vivo liver tracking with a high volume rate 4d ultrasound scanner and a 2d matrix array probe. Phys Med Biol 57(5):1359","journal-title":"Phys Med Biol"},{"issue":"3","key":"1644_CR6","doi-asserted-by":"crossref","first-page":"119","DOI":"10.3109\/10929080600740871","volume":"11","author":"J Borgert","year":"2006","unstructured":"Borgert J, Kruger S, Timinger H, Krucker J, Glossop N, Durrani A, Viswanathan A, Wood BJ (2006) Respiratory motion compensation with tracked internal and external sensors during ct-guided procedures. Comput Aided Surg 11(3):119\u2013125","journal-title":"Comput Aided Surg"},{"key":"1644_CR7","unstructured":"Bricault I, Dimaio S, Clatz O, Pujol S, Vosburgh K, Kikinis R (2005) Computer-assisted interventions on liver: feasibility of the anchor needle technique for real-time targeting of lesions with respiratory motion. In: Surgetica. Chamb\u00e9ry, France. https:\/\/hal.inria.fr\/inria-00616014"},{"issue":"3","key":"1644_CR8","doi-asserted-by":"crossref","first-page":"906","DOI":"10.1148\/radiol.2293021496","volume":"229","author":"SK Carlson","year":"2003","unstructured":"Carlson SK, Felmlee JP, Bender CE, Ehman RL, Classic KL, Hu HH, Hoskin TL (2003) Intermittent-mode ct fluoroscopy-guided biopsy of the lung or upper abdomen with breath-hold monitoring and feedback: system development and feasibility. Radiology 229(3):906\u2013912","journal-title":"Radiology"},{"issue":"1","key":"1644_CR9","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1109\/TBME.2016.2549272","volume":"64","author":"B Chen","year":"2017","unstructured":"Chen B, Weber N, Odille F, Large-Dessale C, Delmas A, Bonnemains L, Felblinger J (2017) Design and validation of a novel mr-compatible sensor for respiratory motion modeling and correction. IEEE Trans Biomed Eng 64(1):123\u2013133. doi: 10.1109\/TBME.2016.2549272","journal-title":"IEEE Trans Biomed Eng"},{"key":"1644_CR10","doi-asserted-by":"publisher","unstructured":"Cleary KR, Banovac F, Levy E, Tanaka D (2002) Development of a liver respiratory motion simulator to investigate magnetic tracking for abdominal interventions. In: Proc. SPIE 4681, medical imaging 2002: visualization, image-guided procedures, and display, 25 (May 16, 2002). doi: 10.1117\/12.466934","DOI":"10.1117\/12.466934"},{"issue":"5","key":"1644_CR11","doi-asserted-by":"crossref","first-page":"291","DOI":"10.3109\/10929080209146038","volume":"7","author":"MA Clifford","year":"2002","unstructured":"Clifford MA, Banovac F, Levy E, Cleary K (2002) Assessment of hepatic motion secondary to respiration for computer assisted interventions. Comput Aided Surg 7(5):291\u2013299","journal-title":"Comput Aided Surg"},{"key":"1644_CR12","doi-asserted-by":"crossref","unstructured":"Davis J, Hsieh YH, Lee H.C (2015) Humans perceive flicker artifacts at 500\u00a0hz. Sci Rep (Nat) 5(7861):1\u20134","DOI":"10.1038\/srep07861"},{"key":"1644_CR13","doi-asserted-by":"crossref","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J, Aylward SR, Miller JV, Pieper S, Kikinis R (2012) 3d slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30:1323\u20131341","journal-title":"Magn Reson Imaging"},{"issue":"4","key":"1644_CR14","doi-asserted-by":"crossref","first-page":"640","DOI":"10.1016\/j.media.2010.07.003","volume":"15","author":"SE Geneser","year":"2011","unstructured":"Geneser SE, Hinkle JD, Kirby RM, Wang B, Salter B, Joshi S (2011) Quantifying variability in radiation dose due to respiratory-induced tumor motion. Med Image Anal 15(4):640\u2013649 (Special section on IPMI 2009)","journal-title":"Med Image Anal"},{"issue":"4","key":"1644_CR15","doi-asserted-by":"crossref","first-page":"1298","DOI":"10.1016\/j.ijrobp.2004.07.681","volume":"60","author":"JDP Hoisak","year":"2004","unstructured":"Hoisak JDP, Sixel KE, Tirona R, Cheung PCF, Pignol JP (2004) Correlation of lung tumor motion with external surrogate indicators of respiration. Int J Radiat Oncol Biol Phys 60(4):1298\u20131306","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"10","key":"1644_CR16","doi-asserted-by":"crossref","first-page":"3874","DOI":"10.1118\/1.2349696","volume":"33","author":"PJ Keall","year":"2006","unstructured":"Keall PJ, Mageras GS, Balter JM, Emery RS, Forster KM, Jiang SB, Kapatoes JM, Low DA, Murphy MJ, Murray BR, Ramsey CR, Van Herk MB, Vedam SS, Wong JW, Yorke E (2006) The management of respiratory motion in radiation oncology report of AAPM task group 76. Med Phys 33(10):3874\u20133900","journal-title":"Med Phys"},{"key":"1644_CR17","doi-asserted-by":"crossref","unstructured":"Klinder T, Lorenz C (2012) Respiratory motion compensation for image-guided bronchoscopy using a general motion model. In: IEEE international symposium on biomedical imaging (ISBI). Barcelona, Spain, pp 960\u2013963","DOI":"10.1109\/ISBI.2012.6235716"},{"issue":"260","key":"1644_CR18","doi-asserted-by":"publisher","first-page":"583","DOI":"10.1080\/01621459.1952.10483441","volume":"47","author":"WH Kruskal","year":"1952","unstructured":"Kruskal WH, Wallis WA (1952) Use of ranks in one-criterion variance analysis. J Am Stat Assoc 47(260):583\u2013621. doi: 10.1080\/01621459.1952.10483441","journal-title":"J Am Stat Assoc"},{"issue":"2","key":"1644_CR19","doi-asserted-by":"crossref","first-page":"210","DOI":"10.3348\/kjr.2012.13.2.210","volume":"13","author":"H Lal","year":"2011","unstructured":"Lal H, Neyaz Z, Nath A, Borah S (2011) Ct-guided percutaneous biopsy of intrathoracic lesions. Korean J Radiol 13(2):210\u2013226","journal-title":"Korean J Radiol"},{"issue":"3","key":"1644_CR20","doi-asserted-by":"crossref","first-page":"435","DOI":"10.1007\/s11548-010-0523-7","volume":"6","author":"P Lei","year":"2011","unstructured":"Lei P, Moeslein F, Wood BJ, Shekhar R (2011) Real-time tracking of liver motion and deformation using a flexible needle. Int J Comput Assist Radiol Surg 6(3):435\u2013446","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"1644_CR21","doi-asserted-by":"crossref","first-page":"921","DOI":"10.1016\/j.ijrobp.2005.03.070","volume":"63","author":"DA Low","year":"2005","unstructured":"Low DA, Parikh PJ, Lu W, Dempsey JF, Wahab SH, Hubenschmidt JP, Nystrom MM, Handoko M, Bradley JD (2005) Novel breathing motion model for radiotherapy. Int J Radiat Oncol Biol Phys 63(3):921\u2013929","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"1644_CR22","doi-asserted-by":"crossref","first-page":"1360","DOI":"10.1118\/1.3326969","volume":"37","author":"DA Low","year":"2010","unstructured":"Low DA, Zhao T, White B, Yang D, Mutic S, Noel CE, Bradley JD, Parikh PJ, Lu W (2010) Application of the continuity equation to a breathing motion model. Med Phys 37(3):1360\u20131364","journal-title":"Med Phys"},{"issue":"7","key":"1644_CR23","doi-asserted-by":"crossref","first-page":"2351","DOI":"10.1118\/1.1935776","volume":"32","author":"W Lu","year":"2005","unstructured":"Lu W, Low DA, Parikh PJ, Nystrom MM, El-Naqa IM, Wahab SH, Handoko M, Fooshee D, Bradley JD (2005) Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung. Med Phys 32(7):2351\u20132357","journal-title":"Med Phys"},{"issue":"3","key":"1644_CR24","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1055\/s-0030-1261783","volume":"27","author":"JR McCarley","year":"2010","unstructured":"McCarley JR, Soulen MC (2010) Percutaneous ablation of hepatic tumors. Semin Interv Radiol 27(3):255\u2013260","journal-title":"Semin Interv Radiol"},{"key":"1644_CR25","first-page":"187","volume-title":"Estimating internal respiratory motion from respiratory surrogate signals using correspondence models, chap. 9","author":"JR McClelland","year":"2013","unstructured":"McClelland JR (2013) Estimating internal respiratory motion from respiratory surrogate signals using correspondence models, chap. 9. Springer, Berlin, pp 187\u2013213"},{"issue":"1","key":"1644_CR26","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.media.2012.09.005","volume":"17","author":"JR McClelland","year":"2013","unstructured":"McClelland JR, Hawkes DJ, Schaeffter T, King AP (2013) Respiratory motion models: a review. Med Image Anal 17(1):19\u201342","journal-title":"Med Image Anal"},{"issue":"3","key":"1644_CR27","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1053\/j.semnuclmed.2008.01.002","volume":"38","author":"SA Nehmeh","year":"2008","unstructured":"Nehmeh SA, Erdi YE (2008) Respiratory motion in positron emission tomography\/computed tomography: a review. Semin Nucl Med 38(3):167\u2013176 Developments in Instrumentation","journal-title":"Semin Nucl Med"},{"key":"1644_CR28","unstructured":"Read J, Reutemann P (2012) Meka: a multi-label extension to weka. http:\/\/meka.sourceforge.net"},{"issue":"4","key":"1644_CR29","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1007\/s00261-013-9980-0","volume":"38","author":"NI Sainani","year":"2013","unstructured":"Sainani NI, Arellano RS, Shyn PB, Gervais DA, Mueller PR, Silverman SG (2013) The challenging image-guided abdominal mass biopsy: established and emerging techniques \u2019if you can see it, you can biopsy it\u2019. Abdom Imaging 38(4):672\u2013696","journal-title":"Abdom Imaging"},{"issue":"4","key":"1644_CR30","doi-asserted-by":"crossref","first-page":"1097","DOI":"10.1002\/mrm.22687","volume":"65","author":"C Santelli","year":"2010","unstructured":"Santelli C, Nezafat R, Goddu B, Manning WJ, Smink J, Kozerke S, Peters DC (2010) Respiratory bellows revisited for motion compensation: preliminary experience for cardiovascular mr. Magn Reson Med 65(4):1097\u20131102","journal-title":"Magn Reson Med"},{"issue":"2","key":"1644_CR31","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1148\/radiol.2502071998","volume":"250","author":"AD Scott","year":"2009","unstructured":"Scott AD, Keegan J, Firmin DN (2009) Motion in cardiovascular mr imaging. Radiology 250(2):331\u2013351","journal-title":"Radiology"},{"issue":"9","key":"1644_CR32","doi-asserted-by":"crossref","first-page":"N103","DOI":"10.1088\/0031-9155\/45\/9\/402","volume":"45","author":"PG Seiler","year":"2000","unstructured":"Seiler PG, Blattmann H, Kirsch S, Muench RK, Schilling C (2000) A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. Phys Med Biol 45(9):N103","journal-title":"Phys Med Biol"},{"issue":"2","key":"1644_CR33","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/S0360-3016(00)00624-6","volume":"48","author":"S Shimizu","year":"2000","unstructured":"Shimizu S, Shirato H, Aoyama H, Hashimoto S, Nishioka T, Yamazaki A, Kagei K, Miyasaka K (2000) High-speed magnetic resonance imaging for four-dimensional treatment planning of conformal radiotherapy of moving body tumors1. Int J Radiat Oncol Biol Phys 48(2):471\u2013474","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"3","key":"1644_CR34","doi-asserted-by":"crossref","first-page":"673","DOI":"10.1148\/radiology.212.3.r99se36673","volume":"212","author":"SG Silverman","year":"1999","unstructured":"Silverman SG, Tuncali K, Adams DF, Nawfel RD, Zou KH, Judy PF (1999) Ct fluoroscopy-guided abdominal interventions: techniques, results, and radiation exposure. Radiology 212(3):673\u2013681","journal-title":"Radiology"},{"key":"1644_CR35","doi-asserted-by":"crossref","unstructured":"Tsoumakas G, Katakis I, Vlahavas I (2011) Random k-labelsets for multilabel classification. IEEE Trans Knowl Data Eng 23(7):1079\u20131089","DOI":"10.1109\/TKDE.2010.164"},{"key":"1644_CR36","doi-asserted-by":"crossref","unstructured":"Tsoumakas G, Vlahavas I (2007) Random k-labelsets: an ensemble method for multilabel classification. In: Proceedings of the European conference on machine learning (ECML), vol 4701. Warsaw, Poland, pp 406\u2013417","DOI":"10.1007\/978-3-540-74958-5_38"},{"key":"1644_CR37","doi-asserted-by":"crossref","unstructured":"Wong KH, Tang J, Zhang HJ, Varghese E, Cleary KR (2005) Prediction of 3d internal organ position from skin surface motion: results from electromagnetic tracking studies. In: Galloway Jr RL, Cleary KR (eds) Proceedings of the SPIE, the International Society for Optical Engineering, medical imaging: visualization, image-guided procedures, and display, vol 5744, pp 879-887","DOI":"10.1117\/12.596843"},{"issue":"10","key":"1644_CR38","doi-asserted-by":"crossref","first-page":"4577","DOI":"10.1118\/1.2977828","volume":"35","author":"D Yang","year":"2008","unstructured":"Yang D, Lu W, Low DA, Deasy JO, Hope AJ, El-Naqa I (2008) 4d-ct motion estimation using deformable image registration and 5d respiratory motion modeling. Med Phys 35(10):4577\u20134590","journal-title":"Med Phys"},{"issue":"3","key":"1644_CR39","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1002\/rcs.1441","volume":"9","author":"Y Zhou","year":"2013","unstructured":"Zhou Y, Thiruvalluvan K, Krzeminski L, Moore WH, Xu Z, Liang Z (2013) Ct-guided robotic needle biopsy of lung nodules with respiratory motion experimental system and preliminary test. Int J Med Robot Comput Assist Surg 9(3):317\u2013330","journal-title":"Int J Med Robot Comput Assist Surg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-017-1644-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1644-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-017-1644-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2025,6,24]],"date-time":"2025-06-24T15:22:54Z","timestamp":1750778574000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-017-1644-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,8,1]]},"references-count":39,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["1644"],"URL":"https:\/\/doi.org\/10.1007\/s11548-017-1644-z","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2017,8,1]]}}}