{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,22]],"date-time":"2025-08-22T04:57:54Z","timestamp":1755838674187,"version":"3.37.3"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"7","license":[{"start":{"date-parts":[[2018,2,28]],"date-time":"2018-02-28T00:00:00Z","timestamp":1519776000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,2,28]],"date-time":"2018-02-28T00:00:00Z","timestamp":1519776000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100009619","name":"Japan Agency for Medical Research and Development","doi-asserted-by":"publisher","award":["15hk0102005h0002"],"award-info":[{"award-number":["15hk0102005h0002"]}],"id":[{"id":"10.13039\/100009619","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2018,7]]},"DOI":"10.1007\/s11548-018-1709-7","type":"journal-article","created":{"date-parts":[[2018,2,28]],"date-time":"2018-02-28T12:39:44Z","timestamp":1519821584000},"page":"1063-1072","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Laparoscopic ultrasound manipulator with a spring-based elastic mechanism"],"prefix":"10.1007","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-3388-5488","authenticated-orcid":false,"given":"Jumpei","family":"Arata","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kazunari","family":"Fukami","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Susumu","family":"Oguri","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shinya","family":"Onogi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tetsuo","family":"Ikeda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ryu","family":"Nakadate","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masamichi","family":"Sakaguchi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomohiko","family":"Akahoshi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kanako","family":"Harada","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Mamoru","family":"Mitsuishi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Hashizume","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,2,28]]},"reference":[{"key":"1709_CR1","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11548-007-0078-4","volume":"2","author":"K Konishi","year":"2007","unstructured":"Konishi K, Nakamoto M, Kakeji Y, Tanoue K, Kawanaka H, Yamaguchi S, Ieiri S, Sato Y, Maehara Y, Tamura S, Hashizume M (2007) A real-time navigation system for laparoscopic surgery based on three-dimensional ultrasound using magneto-optic hybrid tracking configuration. Int J CARS 2:1\u201310","journal-title":"Int J CARS"},{"issue":"3","key":"1709_CR2","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.suronc.2011.07.002","volume":"20","author":"S Nicolau","year":"2011","unstructured":"Nicolau S, Soler L, Mutter D, Marescaux J (2011) Augmented reality in laparoscopic surgical oncology. Surg Oncol 20(3):189\u2013201","journal-title":"Surg Oncol"},{"key":"1709_CR3","unstructured":"(2016) \n                    http:\/\/www.sages.org\/publications\/guidelines\/guidelines-for-the-use-of-laparoscopic-ultrasound\/\n                    \n                  . Accessed 30 Jan 2018"},{"issue":"Suppl 1","key":"1709_CR4","first-page":"S242","volume":"10","author":"S Oguri","year":"2015","unstructured":"Oguri S, Arata J, Ikeda T, Nakadate R, Onogi S, Akahoshi T, Harada K, Mitsuishi M, Hashizume M (2015) Multi-degrees of freedom laparoscopic ultrasound probe with remote center of motion. Int J CARS 10(Suppl 1):S242\u2013244","journal-title":"Int J CARS"},{"key":"1709_CR5","doi-asserted-by":"publisher","first-page":"1837","DOI":"10.1007\/s11548-015-1159-4","volume":"10","author":"J Arata","year":"2015","unstructured":"Arata J, Kogiso S, Sakaguchi M, Nakadate R, Oguri S, Uemura M, Cho B, Akahoshi T, Ikeda T, Hashizume M (2015) Articulated minimally invasive surgical tool for laparoscopy based on compliant mechanism. Int J CARS 10:1837\u20131843","journal-title":"Int J CARS"},{"key":"1709_CR6","doi-asserted-by":"crossref","unstructured":"Arata J, Saito Y, Fujimoto H (2010) Outer shell type 2 DOF bending manipulator using spring-link mechanism for medical applications. In: Proceedings of international conference on robotics and automation, pp 1041\u20131046","DOI":"10.1109\/ROBOT.2010.5509705"},{"issue":"2","key":"1709_CR7","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1590\/S0102-86502014000200010","volume":"29","author":"R Denadai","year":"2014","unstructured":"Denadai R, Toledo AP, Bernades DM, Diniz FD, Eid FB, Lanfranchi LM, Amaro LC, Germani NM, Parise VG, Pacheco Filho CN, Saad-Hossne R (2014) Simulation-based ultrasound-guided central venous cannulation training program. Acta Cir Bras 29(2):132\u2013144","journal-title":"Acta Cir Bras"},{"key":"1709_CR8","unstructured":"(2017) \n                    https:\/\/www.intuitivesurgical.com\/products\/da-vinci-xi\/\n                    \n                  . Accessed 30 Jan 2018"},{"key":"1709_CR9","unstructured":"(2017) \n                    http:\/\/www.hitachi-aloka.com\/applications\/surgery\/laparoscopic-surgery\n                    \n                  . Accessed 30 Jan 2018"},{"key":"1709_CR10","unstructured":"(2017) \n                    https:\/\/bkultrasound.com\/applications\/surgery\/laparoscopic-ultrasound-for-surgery\/\n                    \n                  . Accessed 30 Jan 2018"},{"issue":"12","key":"1709_CR11","doi-asserted-by":"publisher","first-page":"1705","DOI":"10.1016\/j.ultrasmedbio.2003.07.001","volume":"29","author":"L Sandrin","year":"2013","unstructured":"Sandrin L, Fourquet B, Hasquenoph JM, Yon S, Fournier C, Mal F, Christidis C, Ziol M, Poulet B, Kazemi F, Beaugrand M, Palau R (2013) Transient elastography: a new noninvasive method for assessment of hepatic fibrosis. Ultrasound Med Biol 29(12):1705\u20131713","journal-title":"Ultrasound Med Biol"},{"key":"1709_CR12","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1016\/j.procir.2015.09.005","volume":"49","author":"H Sato","year":"2016","unstructured":"Sato H, Harada K, Arata J, Oguri S, Onogi S, Ikeda T, Hashizume M, Mitsuishi M (2016) Design and prototyping of handheld 3-DOF laparoscopic ultrasound manipulator. Procedia CIRP 49:121\u2013124","journal-title":"Procedia CIRP"},{"issue":"7","key":"1709_CR13","doi-asserted-by":"publisher","first-page":"634","DOI":"10.7210\/jrsj.29.634","volume":"29","author":"Y Takachi","year":"2011","unstructured":"Takachi Y, Masuda K, Yasunaga T, Aoki Y (2011) Development of support system for handling ultrasound probe to alleviate fatigue of physician by introducing a coordinated motion with robot. J Robot Soc Jpn 29(7):634\u2013642 (in Japanese)","journal-title":"J Robot Soc Jpn"},{"issue":"Suppl 1","key":"1709_CR14","first-page":"S256","volume":"11","author":"S Onogi","year":"2016","unstructured":"Onogi S, Ikeda T, Arata J, Nakadate R, Oguri S, Akahoshi T, Harada K, Mitsuishi M, Hashizume M (2016) Intra-operative three dimensional ultrasound reconstruction and visualization for endoscopic liver surgery. Int J CARS 11(Suppl 1):S256\u2013257","journal-title":"Int J CARS"},{"issue":"1","key":"1709_CR15","first-page":"S96","volume":"12","author":"S Onogi","year":"2017","unstructured":"Onogi S, Nakadate R, Arata J, Akahoshi T, Ikeda T, Hashizume M (2017) Technical trial of GPGPU volume reconstruction by using a tablet PC for practical clinical navigation system. Int J CARS 12(1):S96\u201397","journal-title":"Int J CARS"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1709-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1709-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1709-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T21:41:02Z","timestamp":1589665262000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1709-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,2,28]]},"references-count":15,"journal-issue":{"issue":"7","published-print":{"date-parts":[[2018,7]]}},"alternative-id":["1709"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1709-7","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2018,2,28]]},"assertion":[{"value":"17 September 2017","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 January 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 February 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"Jumpei Arata, Kazunari Fukami, Susumu Oguri, Tetsuo Ikeda, Ryu Nakadate, Shinya Onogi, Masamichi Sakaguchi, Kanako Harada, Mamoru Mitsuishi, and Makoto Hashizume declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors. All procedures performed in studies involving animals were in accordance with the ethical standards of the institution or practice at which the studies were conducted.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}}]}}