{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,31]],"date-time":"2026-03-31T17:28:25Z","timestamp":1774978105956,"version":"3.50.1"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,7,28]],"date-time":"2018-07-28T00:00:00Z","timestamp":1532736000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100010661","name":"Horizon 2020 Framework Programme","doi-asserted-by":"publisher","award":["645331"],"award-info":[{"award-number":["645331"]}],"id":[{"id":"10.13039\/100010661","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100003130","name":"Fonds Wetenschappelijk Onderzoek","doi-asserted-by":"crossref","award":["1S41517N"],"award-info":[{"award-number":["1S41517N"]}],"id":[{"id":"10.13039\/501100003130","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1007\/s11548-018-1829-0","type":"journal-article","created":{"date-parts":[[2018,7,28]],"date-time":"2018-07-28T07:41:25Z","timestamp":1532763685000},"page":"301-309","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":37,"title":["Combined OCT distance and FBG force sensing cannulation needle for retinal vein cannulation: in vivo animal validation"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4885-8965","authenticated-orcid":false,"given":"M.","family":"Ourak","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6450-3796","authenticated-orcid":false,"given":"J.","family":"Smits","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Esteveny","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Borghesan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Gijbels","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L.","family":"Schoevaerdts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Douven","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.","family":"Scholtes","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E.","family":"Lankenau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"T.","family":"Eixmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Schulz-Hildebrandt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"H\u00fcttmann","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Kozlovszky","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Kronreif","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Willekens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"P.","family":"Stalmans","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.","family":"Faridpooya","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Cereda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"A.","family":"Giani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Staurenghi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"Reynaerts","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"E. B.","family":"Vander Poorten","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,7,28]]},"reference":[{"issue":"11","key":"1829_CR1","doi-asserted-by":"crossref","first-page":"117002","DOI":"10.1117\/1.JBO.21.11.117002","volume":"21","author":"S Ambastha","year":"2016","unstructured":"Ambastha S, Umesh S, Dabir S, Asokan S (2016) Spinal needle force monitoring during lumbar puncture using fiber Bragg grating force device. J Biomed Opt 21(11):117002","journal-title":"J Biomed Opt"},{"issue":"9","key":"1829_CR2","doi-asserted-by":"crossref","first-page":"OCT568","DOI":"10.1167\/iovs.15-18853","volume":"57","author":"T Asami","year":"2016","unstructured":"Asami T, Terasaki H, Ito Y, Sugita T, Kaneko H, Nishiyama J, Namiki H, Kobayashi M, Nishizawa N (2016) Development of a fiber-optic optical coherence tomography probe for intraocular use. Investig Opthalmol Vis Sci 57(9):OCT568\u2013OCT574","journal-title":"Investig Opthalmol Vis Sci"},{"key":"1829_CR3","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1007\/978-3-642-04268-3_14","volume-title":"Medical Image Computing and Computer-Assisted Intervention \u2013 MICCAI 2009","author":"Marcin Balicki","year":"2009","unstructured":"Balicki M, Han Jh, Iordachita I, Gehlbach P, Handa J, Taylor R, Kang J (2009) Single fiber optical coherence tomography microsurgical instruments for computer and robot-assisted retinal surgery. In: Medical image computing and computer-assisted intervention, pp 108\u2013115"},{"issue":"02","key":"1829_CR4","doi-asserted-by":"crossref","first-page":"1840005","DOI":"10.1142\/S2424905X18400056","volume":"3","author":"G Borghesan","year":"2018","unstructured":"Borghesan G, Ourak M, Lankenau E, H\u00fcttmann G, Schulz-Hildebrant H, Willekens K, Stalmans P, Reynaerts D, Vander Poorten E (2018) Single scan OCT-based retina detection for robot-assisted retinal vein cannulation. J Med Robot Res 3(02):1840005","journal-title":"J Med Robot Res"},{"key":"1829_CR5","doi-asserted-by":"crossref","unstructured":"Bruyninckx H, Soetens P, Koninckx B (2003) The real-time motion control core of the Orocos project. In: IEEE international conference on robotics and automation, vol 2, pp 2766\u20132771","DOI":"10.1109\/ROBOT.2003.1242011"},{"issue":"1","key":"1829_CR6","first-page":"61","volume":"16","author":"LT Du","year":"2001","unstructured":"Du LT, Wessels IF, Underdahl JP, Auran JD (2001) Stereoacuity and depth perception decrease with increased instrument magnification: comparing a non-magnified system with lens loupes and a surgical microscope. Binocul Vis Strabismus Q 16(1):61\u20137","journal-title":"Binocul Vis Strabismus Q"},{"issue":"8","key":"1829_CR7","doi-asserted-by":"crossref","first-page":"e105224","DOI":"10.1371\/journal.pone.0105224","volume":"9","author":"JP Ehlers","year":"2014","unstructured":"Ehlers JP, Srivastava SK, Feiler D, Noonan AI, Rollins AM, Tao YK (2014) Integrative Advances for OCT-guided ophthalmic surgery and intraoperative OCT: microscope integration, surgical instrumentation, and heads-up display surgeon feedback. PLoS ONE 9(8):e105224","journal-title":"PLoS ONE"},{"issue":"4","key":"1829_CR8","doi-asserted-by":"crossref","first-page":"044504","DOI":"10.1115\/1.4005318","volume":"5","author":"O Ergeneman","year":"2011","unstructured":"Ergeneman O, Pokki J, Po\u010depcov\u00e0 V, Hall H, Abbott JJ, Nelson BJ (2011) Characterization of puncture forces for retinal vein cannulation. J Med Devices 5(4):044504","journal-title":"J Med Devices"},{"key":"1829_CR9","doi-asserted-by":"crossref","unstructured":"Gijbels A, Vander Poorten EB, Stalmans P, Reynaerts D (2015) Development and experimental validation of a force sensing needle for robotically assisted retinal vein cannulations. In: IEEE international conference on robotics and automation, pp 2270\u20132276","DOI":"10.1109\/ICRA.2015.7139500"},{"key":"1829_CR10","doi-asserted-by":"crossref","unstructured":"Gijbels A, Willekens K, Esteveny L, Stalmans P, Reynaerts D, Vander Poorten EB (2016) Towards a clinically applicable robotic assistance system for retinal vein cannulation. In: IEEE international conference on biomedical robotics and biomechatronics, pp 284\u2013291","DOI":"10.1109\/BIOROB.2016.7523639"},{"issue":"11","key":"1829_CR11","doi-asserted-by":"crossref","first-page":"3526","DOI":"10.1109\/JSEN.2017.2694965","volume":"17","author":"B Gonenc","year":"2017","unstructured":"Gonenc B, Chamani A, Handa J, Gehlbach P, Taylor R, Iordachita I (2017) 3-DOF force-sensing motorized micro-forceps for robot-assisted vitreoretinal surgery. IEEE Sens 17(11):3526\u20133541","journal-title":"IEEE Sens"},{"key":"1829_CR12","doi-asserted-by":"crossref","unstructured":"Gonenc B, Iordachita I (2016) FBG-based transverse and axial force-sensing micro-forceps for retinal microsurgery. In: IEEE sensors","DOI":"10.1109\/ICSENS.2016.7808628"},{"key":"1829_CR13","doi-asserted-by":"crossref","unstructured":"Gonenc B, Taylor RH, Iordachita I, Gehlbach P, Handa J (2014) Force-sensing microneedle for assisted retinal vein cannulation. In: IEEE sensors proceedings, pp 698\u2013701","DOI":"10.1109\/ICSENS.2014.6985095"},{"key":"1829_CR14","doi-asserted-by":"crossref","unstructured":"Gonenc B, Tran N, Riviere CN, Gehlbach P, Taylor RH, Iordachita I (2015) Force-based puncture detection and active position holding for assisted retinal vein cannulation. In: IEEE\/SICE\/RSJ international conference on multisensor fusion and integration for intelligent systems, pp 322\u2013327","DOI":"10.1109\/MFI.2015.7295828"},{"issue":"4","key":"1829_CR15","doi-asserted-by":"crossref","first-page":"429","DOI":"10.1016\/S0002-9394(14)70001-7","volume":"117","author":"SS Hayreh","year":"1994","unstructured":"Hayreh SS, Zimmerman MB, Podhajsky P (1994) Incidence of various types of retinal vein occlusion and their recurrence and demographic characteristics. Am J Ophthalmol 117(4):429\u2013441","journal-title":"Am J Ophthalmol"},{"issue":"2","key":"1829_CR16","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1109\/TBME.2013.2283501","volume":"61","author":"X He","year":"2014","unstructured":"He X, Handa J, Gehlbach P, Taylor RH, Iordachita I (2014) A submillimetric 3-DOF force sensing instrument with integrated fiber bragg grating for retinal microsurgery. IEEE Trans Biomed Eng 61(2):522\u2013534","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"1829_CR17","doi-asserted-by":"crossref","first-page":"383","DOI":"10.1007\/s11548-009-0301-6","volume":"4","author":"I Iordachita","year":"2009","unstructured":"Iordachita I, Sun Z, Balicki M, Kang JU, Phee SJ, Handa J, Gehlbach P, Taylor R (2009) A sub-millimetric, 0.25 mN resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J Comput Assist Radiol Surg 4(4):383\u2013390","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1829_CR18","doi-asserted-by":"crossref","unstructured":"Menciassi A, Eisinberg A, Scalari G, Anticoli C, Carrozza M, Dario P (2001) Force feedback-based microinstrument for measuring tissue properties and pulse in microsurgery. In: IEEE international conference on robotics and automation, vol 1, pp 626\u2013631","DOI":"10.1109\/ROBOT.2001.932620"},{"key":"1829_CR19","first-page":"175","volume":"12","author":"A Molaei","year":"2017","unstructured":"Molaei A, Abedloo E, de Smet MD, Safi S, Khorshidifar M, Ahmadieh H, Khosravi MA, Daftarian N (2017) Toward the art of robotic-assisted vitreoretinal surgery. J Ophthalmic Vis Res 12:175\u2013182","journal-title":"J Ophthalmic Vis Res"},{"key":"1829_CR20","first-page":"1","volume":"8","author":"Y Noda","year":"2013","unstructured":"Noda Y, Ida Y, Tanaka S, Toyama T, Roggia MF, Tamaki Y, Sugita N, Mitsuishi M, Ueta T (2013) Impact of robotic assistance on precision of vitreoretinal surgical procedures. PLoS ONE 8:1\u20136","journal-title":"PLoS ONE"},{"key":"1829_CR21","volume-title":"Ophthalmology at a glance","author":"J Olver","year":"2005","unstructured":"Olver J, Cassidy L (2005) Ophthalmology at a glance. Blackwell Science, Hoboken"},{"issue":"2\u20133","key":"1829_CR22","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1016\/j.sna.2004.04.057","volume":"115","author":"J Peirs","year":"2004","unstructured":"Peirs J, Clijnen J, Reynaerts D, Brussel HV, Herijgers P, Corteville B, Boone S (2004) A micro optical force sensor for force feedback during minimally invasive robotic surgery. Sens Actuators A 115(2\u20133):447\u2013455","journal-title":"Sens Actuators A"},{"key":"1829_CR23","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1109\/TRA.2003.817506","volume":"19","author":"C Riviere","year":"2003","unstructured":"Riviere C, Ang WT, Khosla P (2003) Toward active tremor canceling in handheld microsurgical instruments. IEEE Trans Robot Autom 19:793\u2013800","journal-title":"IEEE Trans Robot Autom"},{"key":"1829_CR24","first-page":"1","volume":"117","author":"S Rogers","year":"2011","unstructured":"Rogers S, Mcintosh RL, Grad B, Journ D, Cheung N, Lim L, Wang JJ, Mitchell P, Kowalski JW, Nguyen H, Wong TY (2011) The prevalence of retinal vein occlusion: pooled data from population studies from the United States, Europe, Asia, and Australia. Popul Stud 117:1\u201314","journal-title":"Popul Stud"},{"issue":"9","key":"1829_CR25","doi-asserted-by":"crossref","first-page":"1387","DOI":"10.1016\/S0161-6420(95)30859-7","volume":"102","author":"RN Sjaarda","year":"1995","unstructured":"Sjaarda RN, Glaser BM, Thompson JT, Murphy RP, Hanham A (1995) Distribution of iatrogenic retinal breaks in macular hole surgery. Ophthalmology 102(9):1387\u20131392","journal-title":"Ophthalmology"},{"key":"1829_CR26","doi-asserted-by":"crossref","unstructured":"Smits J, Mouloud O, Gijbels A, Esteveny L, Borghesan G, Schoevaerdts L, Willekens K, Stalmans P, Lankenau E, Schulz-Hildebrant H, H\u00fcttmann G, Reynaerts D, Vander Poorten, E (2018) Development and experimental validation of a combined FBG force and OCT distance sensing needle for robot-assisted retinal vein cannulation. In: IEEE international conference on robotics and automation","DOI":"10.1109\/ICRA.2018.8460983"},{"key":"1829_CR27","unstructured":"Smits J, Ourak M, Gijbels A, Borghesan G, Esteveny L, Schoevaerdts L, Willekens K, Stalmans P, Lankenau E, H\u00fcttmann G, Reynaerts D, Poorten EBV (2017) Combined force and distance sensing for robot-assisted vitreo-retinal surgery. In: Proceedings of the 7th joint workshop on new technologies for computer\/robot assisted surgery"},{"issue":"21","key":"1829_CR28","doi-asserted-by":"crossref","first-page":"23414","DOI":"10.1364\/OE.20.023414","volume":"20","author":"C Song","year":"2012","unstructured":"Song C, Gehlbach PL, Kang JU (2012) Active tremor cancellation by a \u201csmart\u201d handheld vitreoretinal microsurgical tool using swept source optical coherence tomography. Opt Express 20(21):23414\u201323421","journal-title":"Opt Express"},{"issue":"1","key":"1829_CR29","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1001\/archopht.118.1.138","volume":"118","author":"WM Tang","year":"2000","unstructured":"Tang WM, Han DP (2000) A study of surgical approaches to retinal vascular occlusions. Arch Ophthalmol 118(1):138\u201343","journal-title":"Arch Ophthalmol"},{"issue":"1","key":"1829_CR30","doi-asserted-by":"crossref","first-page":"37","DOI":"10.1108\/02602280410515806","volume":"24","author":"X Zhang","year":"2004","unstructured":"Zhang X (2004) Silicon microsurgery-force sensor based on diffractive optical MEMS encoders. Sensor Rev 24(1):37\u201341","journal-title":"Sensor Rev"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1829-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1829-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1829-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T10:19:53Z","timestamp":1580984393000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1829-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,7,28]]},"references-count":30,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["1829"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1829-0","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,7,28]]},"assertion":[{"value":"27 April 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"18 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors. All applicable international, national, and\/or institutional guidelines for the care and use of animals were followed.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This articles does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}