{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T18:59:33Z","timestamp":1780340373962,"version":"3.54.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2018,8,9]],"date-time":"2018-08-09T00:00:00Z","timestamp":1533772800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2018,10]]},"DOI":"10.1007\/s11548-018-1842-3","type":"journal-article","created":{"date-parts":[[2018,8,9]],"date-time":"2018-08-09T05:35:01Z","timestamp":1533792901000},"page":"1629-1640","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":38,"title":["Preoperative liver registration for augmented monocular laparoscopy using backward\u2013forward biomechanical simulation"],"prefix":"10.1007","volume":"13","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5946-1213","authenticated-orcid":false,"given":"Erol","family":"\u00d6zg\u00fcr","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bongjin","family":"Koo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bertrand","family":"Le Roy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emmanuel","family":"Buc","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Adrien","family":"Bartoli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,8,9]]},"reference":[{"issue":"6","key":"1842_CR1","doi-asserted-by":"publisher","first-page":"594","DOI":"10.1016\/j.media.2005.04.005","volume":"9","author":"I Wolf","year":"2005","unstructured":"Wolf I, Vetter M, Wegner I, B\u00f6ttger T, Nolden M, Sch\u00f6binger M, Hastenteufel M, Kunert T, Meinzer HP (2005) The medical imaging interaction toolkit. Med Image Anal 9(6):594\u2013604","journal-title":"Med Image Anal"},{"issue":"3","key":"1842_CR2","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1016\/j.suronc.2011.07.002","volume":"20","author":"S Nicolau","year":"2011","unstructured":"Nicolau S, Soler L, Mutter D, Marescaux J (2011) Augmented reality in laparoscopic surgical oncology. Surg Oncol 20(3):189\u2013201","journal-title":"Surg Oncol"},{"key":"1842_CR3","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.media.2017.01.007","volume":"37","author":"S Bernhardt","year":"2017","unstructured":"Bernhardt S, Nicolau SA, Soler L, Doignon C (2017) The status of augmented reality in laparoscopic surgery as of 2016. Med Imaging Anal 37:66\u201390","journal-title":"Med Imaging Anal"},{"key":"1842_CR4","doi-asserted-by":"crossref","unstructured":"Koo\u00a0B, Ozgur\u00a0E, Le Roy\u00a0B, Buc\u00a0E, Bartoli\u00a0A (2017) Deformable registration of a preoperative 3D liver volume to a laparoscopy image using contour and shading cues. In: MICCAI","DOI":"10.1007\/978-3-319-66182-7_38"},{"key":"1842_CR5","doi-asserted-by":"crossref","unstructured":"Adagolodjo\u00a0Y, Trivisonne\u00a0R, Haouchine\u00a0N, Cotin\u00a0S, Courtecuisse\u00a0H (2017) Silhouette-based pose estimation for deformable organs application to surgical augmented reality. In: IROS","DOI":"10.1109\/IROS.2017.8202205"},{"key":"1842_CR6","doi-asserted-by":"crossref","unstructured":"Johnsen\u00a0SF, Thompson\u00a0S, Clarkson\u00a0MJ, Modat\u00a0M, Song\u00a0Y, Totz\u00a0J, Gurusamy\u00a0K, Davidson\u00a0B, Taylor\u00a0ZA, Hawkes\u00a0DJ, Ourselin\u00a0S (2015) Database-based estimation of liver deformation under pneumoperitoneum for surgical image-guidance and simulation. In: MICCAI","DOI":"10.1007\/978-3-319-24571-3_54"},{"key":"1842_CR7","doi-asserted-by":"crossref","unstructured":"Bano\u00a0J, Hostettler\u00a0A, Nicolau\u00a0SA, Doignon\u00a0C, Wu\u00a0HS, Huang\u00a0MH, Soler\u00a0L, Marescaux\u00a0J (2012) Simulation of the abdominal wall and its arteries after pneumoperitoneum for guidance of port positioning in laparoscopic surgery. In: ISVC","DOI":"10.1007\/978-3-642-33179-4_1"},{"issue":"4","key":"1842_CR8","doi-asserted-by":"publisher","first-page":"044004","DOI":"10.1117\/1.JMI.2.4.044004","volume":"2","author":"Y Nimura","year":"2015","unstructured":"Nimura Y, Qu JD, Hayashi Y, Oda M, Kitasaka T, Hashizume M, Misawa K, Mori K (2015) Pneumoperitoneum simulation based on mass-spring-damper models for laparoscopic surgical planning. J Med Imaging 2(4):044004","journal-title":"J Med Imaging"},{"key":"1842_CR9","doi-asserted-by":"crossref","unstructured":"Bano\u00a0J, Hostettler\u00a0A, Nicolau\u00a0SA, Cotin\u00a0S, Doignon\u00a0C, Wu\u00a0HS, Huang\u00a0MH, Soler\u00a0L, Marescaux\u00a0J (2012) Simulation of pneumoperitoneum for laparoscopic surgery planning. In: MICCAI","DOI":"10.1007\/978-3-642-33415-3_12"},{"key":"1842_CR10","doi-asserted-by":"crossref","unstructured":"Collins\u00a0T, Pizarro\u00a0D, Bartoli\u00a0A, Bourdel\u00a0N, Canis\u00a0M (2014) Computer-aided laparoscopic myomectomy by augmenting the uterus with pre-operative MRI data. In: ISMAR","DOI":"10.1109\/ISMAR.2014.6948434"},{"key":"1842_CR11","doi-asserted-by":"crossref","unstructured":"Bernhardt\u00a0S, Nicolau\u00a0S, Bartoli\u00a0A, Agnus\u00a0V, Soler\u00a0L, Doignon\u00a0C (2015) Using shading to register an intraoperative CT scan to a laparoscopic image. Workshop CARE at MICCAI","DOI":"10.1007\/978-3-319-29965-5_6"},{"key":"1842_CR12","doi-asserted-by":"crossref","unstructured":"Saito\u00a0A, Nakao\u00a0M, Uranishi\u00a0Y, Matsuda\u00a0T (2015) Deformation estimation of elastic bodies using multiple silhouette images for endoscopic image augmentation. In: ISMAR","DOI":"10.1109\/ISMAR.2015.49"},{"key":"1842_CR13","doi-asserted-by":"crossref","unstructured":"Haouchine\u00a0N, Roy\u00a0F, Untereiner\u00a0L, Cotin\u00a0S (2016) Using contours as boundary conditions for elastic registration during minimally invasive hepatic surgery. In: IROS","DOI":"10.1109\/IROS.2016.7759099"},{"issue":"11","key":"1842_CR14","doi-asserted-by":"publisher","first-page":"111901","DOI":"10.1118\/1.4896021","volume":"41","author":"S Suwelack","year":"2014","unstructured":"Suwelack S, R\u00f6hl S, Bodenstedt S, Reichard D, Dillmann R, Thiago S, Maier-Hein L, Wagner M, W\u00fcnscher J, Kenngott H, M\u00fcller BP, Spiedel S (2014) Physics-based shape matching for intraoperative image guidance. Med Phys 41(11):111901","journal-title":"Med Phys"},{"key":"1842_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.cag.2014.07.004","volume":"44","author":"J Bender","year":"2014","unstructured":"Bender J, Koschier D, Charrier P, Weber D (2014) Position-based simulation of continuous materials. Comput Graph 44:1\u201310","journal-title":"Comput Graph"},{"key":"1842_CR16","unstructured":"Toledo\u00a0M, Ribeiro\u00a0PC (2009) Radiological evaluation of a liver simulator in comparison to a human real liver. In: International Nuclear Atlantic Conference, INAC"},{"key":"1842_CR17","doi-asserted-by":"publisher","first-page":"23168","DOI":"10.3390\/s150923168","volume":"15","author":"Q Mourcou","year":"2015","unstructured":"Mourcou Q, Fleury A, Franco C, Klopcic F, Vuillerme N (2015) Performance evaluation of smartphone inertial sensors measurement for range of motion. Sensors 15:23168\u201323187","journal-title":"Sensors"},{"issue":"3","key":"1842_CR18","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1080\/10273660500148606","volume":"6","author":"J Whiteley","year":"2005","unstructured":"Whiteley J (2005) The solution of inverse non-linear elasticity problems that arise when locating breast tumours. J Theor Med 6(3):143\u2013149","journal-title":"J Theor Med"},{"key":"1842_CR19","doi-asserted-by":"crossref","unstructured":"Carter\u00a0T, Tanner\u00a0C, Beechey-Newman\u00a0N, Barratt\u00a0D, Hawkes\u00a0D (2008) MR navigated breast surgery: method and initial clinical experience. In: MICCAI","DOI":"10.1007\/978-3-540-85990-1_43"},{"key":"1842_CR20","doi-asserted-by":"crossref","unstructured":"Eiben\u00a0B, Han\u00a0L, Hipwell\u00a0J, Mertzanidou\u00a0T, Kabus\u00a0S, Buelow\u00a0T, Lorenz\u00a0C, Newstead\u00a0GM, Abe\u00a0H, Keshtgar\u00a0M, Ourselin\u00a0S, Hawkes\u00a0DJ (2013) Biomechanically guided prone-to-supine image registration of breast MRI using an estimated reference state. In: ISBI","DOI":"10.1109\/ISBI.2013.6556450"},{"key":"1842_CR21","doi-asserted-by":"publisher","first-page":"1461","DOI":"10.1016\/j.jfluidstructs.2011.08.002","volume":"27","author":"M Sellier","year":"2011","unstructured":"Sellier M (2011) An iterative method for the inverse elasto-static problem. J Fluids Struct 27:1461\u20131470","journal-title":"J Fluids Struct"},{"key":"1842_CR22","doi-asserted-by":"publisher","first-page":"2006","DOI":"10.1080\/10255842.2015.1070591","volume":"18","author":"F Morin","year":"2015","unstructured":"Morin F, Courtecuisse H, Chabanas M, Payan Y (2015) Rest shape computation for highly deformable model of brain. Comput Methods Biomech Biomed Eng 18:2006\u20132007","journal-title":"Comput Methods Biomech Biomed Eng"},{"key":"1842_CR23","doi-asserted-by":"crossref","unstructured":"Eiben\u00a0B, Vavourakis\u00a0V, Hipwell\u00a0J, Kabus\u00a0S, Lorenz\u00a0C, Buelow\u00a0T, Hawkes\u00a0DJ (2014) Breast deformation modelling: comparison of methods to obtain a patient specific unloaded configuration. In: Conference on medical imaging\u2014image-guided procedures, robotic interventions, and modeling","DOI":"10.1117\/12.2043607"},{"key":"1842_CR24","doi-asserted-by":"crossref","unstructured":"Mackling\u00a0M, M\u00fcller\u00a0M, Chentanez\u00a0N (2016) XPBD: position-based simulation of compliant constrained dynamics. In: MIG","DOI":"10.1145\/2994258.2994272"},{"issue":"2","key":"1842_CR25","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s11263-008-0152-6","volume":"81","author":"V Lepetit","year":"2008","unstructured":"Lepetit V, Moreno-Noguer F, Fua P (2008) EPnP: an accurate O(n) solution to the PnP problem. Int J Comput Vis 81(2):155\u2013166","journal-title":"Int J Comput Vis"},{"key":"1842_CR26","doi-asserted-by":"crossref","unstructured":"Bosman\u00a0J, Haouchine\u00a0N, Dequidt\u00a0J, Peterlik\u00a0I (2014) The role of ligaments: patient-specific or scenario-specific? In: ISBMS","DOI":"10.1007\/978-3-319-12057-7_26"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1842-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1842-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1842-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,8,8]],"date-time":"2019-08-08T19:14:46Z","timestamp":1565291686000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1842-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,9]]},"references-count":26,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2018,10]]}},"alternative-id":["1842"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1842-3","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,9]]},"assertion":[{"value":"16 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 July 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 August 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from the patients included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}