{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,3]],"date-time":"2026-06-03T01:21:40Z","timestamp":1780449700280,"version":"3.54.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2018,8,20]],"date-time":"2018-08-20T00:00:00Z","timestamp":1534723200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100002701","name":"Ministry of Education","doi-asserted-by":"publisher","award":["NRF-2016R1D1A1B03933079"],"award-info":[{"award-number":["NRF-2016R1D1A1B03933079"]}],"id":[{"id":"10.13039\/501100002701","id-type":"DOI","asserted-by":"publisher"}]},{"name":"National Research Foundation of Korea (KR)","award":["2015M3D5A1065682"],"award-info":[{"award-number":["2015M3D5A1065682"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2018,11]]},"DOI":"10.1007\/s11548-018-1846-z","type":"journal-article","created":{"date-parts":[[2018,8,20]],"date-time":"2018-08-20T06:40:06Z","timestamp":1534747206000},"page":"1843-1852","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":29,"title":["Real-time microrobot posture recognition via biplane X-ray imaging system for external electromagnetic actuation"],"prefix":"10.1007","volume":"13","author":[{"given":"Phu Bao","family":"Nguyen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Byungjeon","family":"Kang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D. M.","family":"Bappy","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eunpyo","family":"Choi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sukho","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seong Young","family":"Ko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jong-Oh","family":"Park","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4532-2006","authenticated-orcid":false,"given":"Chang-Sei","family":"Kim","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,8,20]]},"reference":[{"key":"1846_CR1","unstructured":"World Health Organization (2015) Noncommunicable diseases progress monitor 2015"},{"key":"1846_CR2","unstructured":"Dharmarajah B (2015) European Congress of Radiology, p 1"},{"key":"1846_CR3","doi-asserted-by":"publisher","first-page":"1494","DOI":"10.1001\/jamainternmed.2014.3415","volume":"174","author":"R Bashir","year":"2014","unstructured":"Bashir R, Zack CJ, Zhao H, Comerota AJ, Bove AA (2014) Comparative outcomes of catheter-directed thrombolysis plus anticoagulation vs anticoagulation alone to treat lower-extremity proximal deep vein thrombosis. JAMA Intern Med 174:1494\u20131501. https:\/\/doi.org\/10.1001\/jamainternmed.2014.3415","journal-title":"JAMA Intern Med"},{"key":"1846_CR4","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1053\/j.jvca.2013.02.027","volume":"28","author":"A Bowdle","year":"2014","unstructured":"Bowdle A (2014) Vascular complications of central venous catheter placement: evidence-based methods for prevention and treatment. J Cardiothorac Vasc Anesth 28:358\u2013368","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"1846_CR5","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1146\/annurev-bioeng-010510-103409","volume":"12","author":"BJ Nelson","year":"2010","unstructured":"Nelson BJ, Kaliakatsos IK, Abbott JJ (2010) Microrobots for minimally invasive medicine. Annu Rev Biomed Eng 12:55\u201385. https:\/\/doi.org\/10.1146\/annurev-bioeng-010510-103409","journal-title":"Annu Rev Biomed Eng"},{"key":"1846_CR6","doi-asserted-by":"crossref","unstructured":"Belharet K, Folio D, Ferreira A (2010) 3D MRI-based predictive control of a ferromagnetic microrobot navigating in blood vessels. In: 2010 3rd IEEE RAS and EMBS international conference on biomedical robotics and biomechatronics, BioRob 2010, pp 808\u2013813","DOI":"10.1109\/BIOROB.2010.5628063"},{"key":"1846_CR7","doi-asserted-by":"publisher","first-page":"614","DOI":"10.1016\/j.compbiomed.2012.02.007","volume":"42","author":"J Climent","year":"2012","unstructured":"Climent J, Hexsel RA (2012) Particle filtering in the Hough space for instrument tracking. Comput Biol Med 42:614\u2013623. https:\/\/doi.org\/10.1016\/j.compbiomed.2012.02.007","journal-title":"Comput Biol Med"},{"key":"1846_CR8","doi-asserted-by":"publisher","first-page":"681","DOI":"10.1007\/s11548-017-1534-4","volume":"12","author":"E Lugez","year":"2017","unstructured":"Lugez E, Sadjadi H, Joshi CP, Akl SG, Fichtinger G (2017) Improved electromagnetic tracking for catheter path reconstruction with application in high-dose-rate brachytherapy. Int J Comput Assist Radiol Surg 12:681\u2013689","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1846_CR9","doi-asserted-by":"crossref","unstructured":"Oh J, Park JO, Park S, Ko SY (2015) Image-based guidance system for intravascular microrobot: Fiducial marker-based registration using biplanar fluoroscopic images and CTA images. In: 2015 15th international conference on control, automation and systems (ICCAS), pp 919\u2013922","DOI":"10.1109\/ICCAS.2015.7364753"},{"key":"1846_CR10","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1007\/978-3-319-10437-9_5","volume-title":"Augmented Environments for Computer-Assisted Interventions","author":"Laura J. Brattain","year":"2014","unstructured":"Brattain LJ, Loschak PM, Tschabrunn CM, Anter E, Howe RD (2014) Instrument tracking and visualization for ultrasound catheter guided procedures. In: Augmented environments for computer-assisted interventions, pp 41\u201350"},{"key":"1846_CR11","doi-asserted-by":"crossref","unstructured":"Saxena A, Driemeyer J, Ng AY (2009) Learning 3-d object orientation from images. In Robotics and Automation. In: ICRA\u201909. 2009 IEEE international conference on robotics and automation, pp 794\u2013800","DOI":"10.1109\/ROBOT.2009.5152855"},{"key":"1846_CR12","doi-asserted-by":"crossref","unstructured":"Nakabo Y, Ishi I, Ishikawa M (2002) 3D tracking using two high-speed vision systems. In: Proceedings of IEEE\/RSJ international conference on intelligent robots and systems, pp 360\u2013365","DOI":"10.1109\/IRDS.2002.1041415"},{"key":"1846_CR13","doi-asserted-by":"publisher","first-page":"5","DOI":"10.1007\/s11701-011-0332-1","volume":"6","author":"S Tognarelli","year":"2012","unstructured":"Tognarelli S, Castelli V, Ciuti G, Di Natali C, Sinibaldi E, Dario P, Menciassi A (2012) Magnetic propulsion and ultrasound tracking of endovascular devices. J Robot Surg 6:5\u201312. https:\/\/doi.org\/10.1007\/s11701-011-0332-1","journal-title":"J Robot Surg"},{"key":"1846_CR14","doi-asserted-by":"publisher","first-page":"118","DOI":"10.1016\/j.compbiomed.2017.11.006","volume":"92","author":"JM Iaquinto","year":"2018","unstructured":"Iaquinto JM, Kindig MW, Haynor DR, Vu QB, Pepin N, Tsai R, Sangeorzan BJ, Ledoux WR (2018) Model-based tracking of the bones of the foot: a biplane fluoroscopy validation study. Comput Biol Med 92:118\u2013127. https:\/\/doi.org\/10.1016\/j.compbiomed.2017.11.006","journal-title":"Comput Biol Med"},{"key":"1846_CR15","doi-asserted-by":"publisher","first-page":"476","DOI":"10.1109\/34.765658","volume":"21","author":"A Fitzgibbon","year":"1999","unstructured":"Fitzgibbon A, Pilu M, Fisher RB (1999) Direct least square fitting of ellipses. IEEE Trans Pattern Anal Mach Intell 21:476\u2013480. https:\/\/doi.org\/10.1109\/34.765658","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1846_CR16","doi-asserted-by":"publisher","first-page":"229","DOI":"10.1007\/s11548-017-1692-4","volume":"13","author":"JR Benjamin","year":"2018","unstructured":"Benjamin JR, Jayasree T (2018) Improved medical image fusion based on cascaded PCA and shift invariant wavelet transforms. Int J Comput Assist Radiol Surg 13:229\u2013240","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1846_CR17","unstructured":"Wijewickrema SNR, Paplinski AP (2005) Principal component analysis for the approximation of a fruit as an ellipse. In: Proceedings of 13th international conference central Europe on computer graphics, visualization and computer vision, pp 1\u20136"},{"key":"1846_CR18","doi-asserted-by":"publisher","first-page":"1319","DOI":"10.1007\/s11548-015-1325-8","volume":"11","author":"C Baur","year":"2016","unstructured":"Baur C, Milletari F, Belagiannis V, Navab N, Fallavollita P (2016) Automatic 3D reconstruction of electrophysiology catheters from two-view monoplane C-arm image sequences. Int J Comput Assist Radiol Surg 11:1319\u20131328","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1846_CR19","doi-asserted-by":"crossref","unstructured":"Nguyen PB, Park JO, Park S, Ko SY (2016) Medical micro-robot navigation using image processing-blood vessel extraction and X-ray calibration. In Proceedings of the IEEE RAS and EMBS international conference on biomedical robotics and biomechatronics, vol 2016, pp 365\u2013370","DOI":"10.1109\/BIOROB.2016.7523653"},{"key":"1846_CR20","volume-title":"Multiple view geometry in computer vision","author":"AZ Richard Harltey","year":"2004","unstructured":"Richard Harltey AZ (2004) Multiple view geometry in computer vision. Cambridge University Press, Cambridge"},{"key":"1846_CR21","doi-asserted-by":"publisher","first-page":"403","DOI":"10.1016\/j.medengphy.2016.01.001","volume":"38","author":"S Jeong","year":"2016","unstructured":"Jeong S, Choi H, Go G, Lee C, Lim KS, Sim DS, Jeong MH, Ko SY, Park JO, Park S (2016) Penetration of an artificial arterial thromboembolism in a live animal using an intravascular therapeutic microrobot system. Med Eng Phys 38:403\u2013410","journal-title":"Med Eng Phys"},{"key":"1846_CR22","doi-asserted-by":"crossref","unstructured":"M\u00f6nnich H, Stein D, Raczkowsky J, W\u00f6rn H (2010) An automatic and complete self-calibration method for robotic guided laser ablation. In: Proceedings of IEEE international conference on robotics and automation, pp 1086\u20131087","DOI":"10.1109\/ROBOT.2010.5509228"},{"key":"1846_CR23","doi-asserted-by":"publisher","first-page":"629","DOI":"10.1364\/JOSAA.4.000629","volume":"4","author":"BKP Horn","year":"1987","unstructured":"Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4:629. https:\/\/doi.org\/10.1364\/JOSAA.4.000629","journal-title":"J Opt Soc Am A"},{"key":"1846_CR24","unstructured":"Stein D, Moennich H, Raczkowsky J, Woern H (2009) IEEE automatic and hand guided self-registration between a robot and an optical tracking system. In: ICAR 2009 14th international conference on advanced robotics, vol 1\u20132, pp 13\u201317"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1846-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1846-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1846-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,11,8]],"date-time":"2020-11-08T00:31:15Z","timestamp":1604795475000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1846-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,8,20]]},"references-count":24,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2018,11]]}},"alternative-id":["1846"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1846-z","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,8,20]]},"assertion":[{"value":"24 April 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 August 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflicts of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies, performed by any of the authors, with human participants or animals.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}