{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T17:14:55Z","timestamp":1773249295454,"version":"3.50.1"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T00:00:00Z","timestamp":1535760000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","award":["1R21NS091735-01"],"award-info":[{"award-number":["1R21NS091735-01"]}],"id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1007\/s11548-018-1854-z","type":"journal-article","created":{"date-parts":[[2018,9,1]],"date-time":"2018-09-01T10:41:09Z","timestamp":1535798469000},"page":"105-115","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":42,"title":["MR-conditional steerable needle robot for intracerebral hemorrhage removal"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9224-4165","authenticated-orcid":false,"given":"Yue","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isuru S.","family":"Godage","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Saikat","family":"Sengupta","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cindy Lin","family":"Liu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyle D.","family":"Weaver","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Eric J.","family":"Barth","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,9,1]]},"reference":[{"key":"1854_CR1","first-page":"301","volume":"60","author":"JH Tapia-Perez","year":"2016","unstructured":"Tapia-Perez JH, Zilke R, Schneider T (2016) Match-study of statin therapy in spontaneous intracerebral hemorrhage: is the discontinuation reasonable? J Neurosurg Sci 60:301\u2013312","journal-title":"J Neurosurg Sci"},{"key":"1854_CR2","doi-asserted-by":"publisher","first-page":"759","DOI":"10.1161\/STROKEAHA.111.616730","volume":"43","author":"N Etminan","year":"2012","unstructured":"Etminan N, Beseoglu K, Turowski B, Steiger H-J, H\u00e4nggi D (2012) Perfusion CT in patients with spontaneous lobar intracerebral hemorrhage: effect of surgery on perihemorrhagic perfusion. Stroke 43:759\u2013763","journal-title":"Stroke"},{"issue":"5","key":"1854_CR3","doi-asserted-by":"publisher","first-page":"657","DOI":"10.1055\/s-0028-1105974","volume":"28","author":"L Elijovich","year":"2008","unstructured":"Elijovich L, Patel PV, Hemphill JC (2008) Intracerebral hemorrhage. Semin Neurol 28(5):657\u2013667","journal-title":"Semin Neurol"},{"key":"1854_CR4","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1179\/016164102101199549","volume":"24","author":"G Maira","year":"2002","unstructured":"Maira G, Anile C, Colosimo C, Rossi GF (2002) Surgical treatment of primary supratentorial intracerebral hemorrhage in stuporous and comatose patients. Neurol Res 24:54\u201360","journal-title":"Neurol Res"},{"key":"1854_CR5","doi-asserted-by":"publisher","first-page":"2567","DOI":"10.1109\/TBME.2013.2260860","volume":"60","author":"J Burgner","year":"2013","unstructured":"Burgner J, Swaney PJ, Lathrop RA, Weaver KD, Webster RJ (2013) Debulking from within: a robotic steerable cannula for intracerebral hemorrhage evacuation. IEEE Trans Biomed Eng 60:2567\u20132575","journal-title":"IEEE Trans Biomed Eng"},{"key":"1854_CR6","doi-asserted-by":"publisher","first-page":"876","DOI":"10.1109\/LRA.2016.2528297","volume":"1","author":"J Granna","year":"2016","unstructured":"Granna J, Godage IS, Wirz R, Weaver KD, Webster RJ, Burgner-Kahrs J (2016) A 3-D volume coverage path planning algorithm with application to intracerebral hemorrhage evacuation. IEEE Robot Autom Lett 1:876\u2013883","journal-title":"IEEE Robot Autom Lett"},{"key":"1854_CR7","doi-asserted-by":"crossref","unstructured":"Godage IS, Remirez AA, Wirz R, Weaver KD, Burgner-Kahrs J, Webster RJ (2015) Robotic intracerebral hemorrhage evacuation: an in-scanner approach with concentric tube robots. In: 2015 IEEE\/RSJ international conference on intelligent robots and systems (IROS), 2015, pp 1447\u20131452","DOI":"10.1109\/IROS.2015.7353558"},{"key":"1854_CR8","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1109\/10.821778","volume":"47","author":"MI Miga","year":"2000","unstructured":"Miga MI, Paulsen KD, Hoopes PJ, Kennedy FE, Hartov A, Roberts DW (2000) In vivo quantification of a homogeneous brain deformation model for updating preoperative images during surgery. IEEE Trans Biomed Eng 47:266\u2013273","journal-title":"IEEE Trans Biomed Eng"},{"key":"1854_CR9","doi-asserted-by":"publisher","first-page":"502","DOI":"10.1161\/01.STR.0000114203.75678.88","volume":"35","author":"JB Fiebach","year":"2004","unstructured":"Fiebach JB, Schellinger PD, Gass A, Kucinski T, Siebler M, Villringer A, \u00d6lkers P, Hirsch JG, Heiland S, Wilde P (2004) Stroke magnetic resonance imaging is accurate in hyperacute intracerebral hemorrhage: a multicenter study on the validity of stroke imaging. Stroke 35:502\u2013506","journal-title":"Stroke"},{"key":"1854_CR10","series-title":"Acta Neurochirurgica Supplements","doi-asserted-by":"publisher","first-page":"7","DOI":"10.1007\/978-3-7091-6043-5_2","volume-title":"Intraoperative Imaging in Neurosurgery","author":"FA Jolesz","year":"2003","unstructured":"Jolesz FA (2003) Future perspectives in intraoperative imaging. In: Bernays RL, Imhof HG, Yonekawa Y (eds) Intraoperative Imaging in Neurosurgery, vol 85. Springer, Vienna, pp 7\u201313"},{"key":"1854_CR11","doi-asserted-by":"publisher","first-page":"971","DOI":"10.1002\/mrm.25001","volume":"72","author":"S Sengupta","year":"2014","unstructured":"Sengupta S, Tadanki S, Gore JC, Welch EB (2014) Prospective real-time head motion correction using inductively coupled wireless NMR probes. Magn Reson Med 72:971\u2013985","journal-title":"Magn Reson Med"},{"key":"1854_CR12","doi-asserted-by":"publisher","first-page":"7114","DOI":"10.1118\/1.4935535","volume":"42","author":"W Wang","year":"2015","unstructured":"Wang W, Viswanathan AN, Damato AL, Chen Y, Tse Z, Pan L, Tokuda J, Seethamraju RT, Dumoulin CL, Schmidt EJ (2015) Evaluation of an active magnetic resonance tracking system for interstitial brachytherapy. Med Phys 42:7114\u20137121","journal-title":"Med Phys"},{"key":"1854_CR13","doi-asserted-by":"publisher","first-page":"956","DOI":"10.1109\/TMECH.2015.2503427","volume":"21","author":"Y Chen","year":"2016","unstructured":"Chen Y, Wang W, Schmidt EJ, Kwok K-W, Viswanathan AN, Cormack R, Tse ZTH (2016) Design and fabrication of MR-tracked metallic stylet for gynecologic brachytherapy. IEEE\/ASME Trans Mechatron 21:956\u2013962","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"1854_CR14","volume-title":"Interfacing fast multi-phase cardiac image registration with MRI-based catheter tracking for MRI-guided electrophysiological ablative procedures","author":"K-W Kwok","year":"2014","unstructured":"Kwok K-W, Lee K-H, Chen Y, Wang W, Hu Y, Chow GC, Zhang HS, Stevenson WG, Kwong RY, Luk W (2014) Interfacing fast multi-phase cardiac image registration with MRI-based catheter tracking for MRI-guided electrophysiological ablative procedures. Am Heart Assoc, Dallas"},{"key":"1854_CR15","doi-asserted-by":"publisher","first-page":"O50","DOI":"10.1186\/1532-429X-16-S1-O50","volume":"16","author":"K-W Kwok","year":"2014","unstructured":"Kwok K-W, Chen Y, Chau TC, Luk W, Nilsson KR, Schmidt EJ, Zion TT (2014) MRI-based visual and haptic catheter feedback: simulating a novel system\u2019s contribution to efficient and safe MRI-guided cardiac electrophysiology procedures. J Cardiovasc Magn Reson 16:O50","journal-title":"J Cardiovasc Magn Reson"},{"key":"1854_CR16","doi-asserted-by":"publisher","first-page":"P237","DOI":"10.1186\/1532-429X-17-S1-P237","volume":"17","author":"Y Chen","year":"2015","unstructured":"Chen Y, Zion TT, Wang W, Kwong RY, Stevenson WG, Schmidt EJ (2015) Intra-cardiac MR imaging and MR-tracking catheter for improved MR-guided EP. J Cardiovasc Magn Reson 17:P237","journal-title":"J Cardiovasc Magn Reson"},{"key":"1854_CR17","doi-asserted-by":"publisher","first-page":"242","DOI":"10.1002\/(SICI)1522-712X(1995)1:4<242::AID-IGS7>3.0.CO;2-A","volume":"1","author":"K Masamune","year":"1995","unstructured":"Masamune K, Kobayashi E, Masutani Y, Suzuki M, Dohi T, Iseki H, Takakura K (1995) Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. J Image Guided Surg 1:242\u2013248","journal-title":"J Image Guided Surg"},{"key":"1854_CR18","doi-asserted-by":"publisher","first-page":"1141","DOI":"10.3171\/2009.2.JNS081334","volume":"111","author":"S Pandya","year":"2009","unstructured":"Pandya S, Motkoski JW, Serrano-Almeida C, Greer AD, Latour I, Sutherland GR (2009) Advancing neurosurgery with image-guided robotics. J Neurosurg 111:1141\u20131149","journal-title":"J Neurosurg"},{"key":"1854_CR19","doi-asserted-by":"crossref","unstructured":"Sheng J, Desai JP (2015) Towards a SMA-actuated neurosurgical intracerebral hemorrhage evacuation (NICHE) robot. In: 2015 IEEE\/RSJ international conference on intelligent robots and systems (IROS), pp 3805\u20133810","DOI":"10.1109\/IROS.2015.7353911"},{"key":"1854_CR20","doi-asserted-by":"publisher","first-page":"2863","DOI":"10.1007\/s10439-016-1585-7","volume":"44","author":"H Su","year":"2016","unstructured":"Su H, Li G, Rucker DC, Webster RJ III, Fischer GS (2016) A concentric tube continuum robot with piezoelectric actuation for MRI-guided closed-loop targeting. Ann Biomed Eng 44:2863\u20132873","journal-title":"Ann Biomed Eng"},{"key":"1854_CR21","doi-asserted-by":"crossref","unstructured":"Chen Y, Godage IS, Sengupta S, Liu CL, Weaver KD, Barth EJ, Webster RJ (2017) An MRI-compatible robot for intracerebral hemorrhage removal. In: 2017 design of medical devices conference, pp V001T08A019\u2013V001T08A019","DOI":"10.1115\/DMD2017-3451"},{"key":"1854_CR22","unstructured":"ASTM. F2503 (2005) Standard practice for marking medical devices and other items for safety in the magnetic resonance environment. \n                    http:\/\/www.astm.org\/\n                    \n                  . Accessed 21 Jan 2018"},{"key":"1854_CR23","doi-asserted-by":"publisher","first-page":"1286","DOI":"10.1136\/adc.67.10.1286","volume":"67","author":"K Bushby","year":"1992","unstructured":"Bushby K, Cole T, Matthews J, Goodship J (1992) Centiles for adult head circumference. Arch Dis Child 67:1286\u20131287","journal-title":"Arch Dis Child"},{"key":"1854_CR24","doi-asserted-by":"publisher","first-page":"2780","DOI":"10.1109\/TMECH.2017.2767906","volume":"22","author":"Y Chen","year":"2017","unstructured":"Chen Y, Godage IS, Tse ZTH, Webster RJ, Barth EJ (2017) Characterization and control of a pneumatic motor for MR-conditional robotic applications. IEEE\/ASME Trans Mechatron 22:2780\u20132789","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"1854_CR25","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1109\/TMMS.1969.299896","volume":"10","author":"DE Whitney","year":"1969","unstructured":"Whitney DE (1969) Resolved motion rate control of manipulators and human prostheses. IEEE Trans Man Mach Syst 10:47\u201353","journal-title":"IEEE Trans Man Mach Syst"},{"key":"1854_CR26","doi-asserted-by":"publisher","first-page":"E5","DOI":"10.3171\/2016.4.FOCUS1622","volume":"41","author":"AY Chan","year":"2016","unstructured":"Chan AY, Tran DKT, Gill AS, Hsu FP, Vadera S (2016) Stereotactic robot-assisted MRI-guided laser thermal ablation of radiation necrosis in the posterior cranial fossa. Neurosurg Focus 41:E5","journal-title":"Neurosurg Focus"},{"key":"1854_CR27","doi-asserted-by":"publisher","first-page":"694","DOI":"10.1109\/42.736021","volume":"17","author":"JM Fitzpatrick","year":"1998","unstructured":"Fitzpatrick JM, West JB, Maurer CR Jr (1998) Predicting error in rigid-body point-based registration. IEEE Trans Med Imaging 17:694\u2013702","journal-title":"IEEE Trans Med Imaging"},{"key":"1854_CR28","unstructured":"Sinclair T, Mougenot C, Kivinen J (2012) MatMRI and MatHIFU: Matlab toolboxes for real-time monitoring and control of MR-HIFU. In: 12th international society for therapeutic ultrasound symposium, Heidelberg, Germany, pp 156\u2013161"},{"key":"1854_CR29","doi-asserted-by":"publisher","first-page":"1823","DOI":"10.1007\/s10439-014-1049-x","volume":"42","author":"Y Chen","year":"2014","unstructured":"Chen Y, Kwok K-W, Tse ZTH (2014) An MR-conditional high-torque pneumatic stepper motor for MRI-guided and robot-assisted intervention. Ann Biomed Eng 42:1823\u20131833","journal-title":"Ann Biomed Eng"},{"key":"1854_CR30","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1109\/TMECH.2014.2305839","volume":"20","author":"Y Chen","year":"2015","unstructured":"Chen Y, Mershon CD, Tse ZTH (2015) A 10-mm MR-conditional unidirectional pneumatic stepper motor. IEEE\/ASME Trans Mechatron 20:782\u2013788","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"1854_CR31","doi-asserted-by":"publisher","first-page":"107","DOI":"10.1109\/TMECH.2016.2611570","volume":"22","author":"Y Chen","year":"2017","unstructured":"Chen Y, Squires A, Seifabadi R, Xu S, Agarwal HK, Bernardo M, Pinto PA, Choyke P, Wood B, Tse ZTH (2017) Robotic system for MRI-guided focal laser ablation in the prostate. IEEE\/ASME Trans Mechatron 22:107\u2013114","journal-title":"IEEE\/ASME Trans Mechatron"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1854-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1854-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1854-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T21:41:59Z","timestamp":1589665319000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1854-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,9,1]]},"references-count":31,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["1854"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1854-z","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,9,1]]},"assertion":[{"value":"26 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 August 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}