{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T17:43:45Z","timestamp":1789753425374,"version":"4.0.1"},"reference-count":37,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,10,5]],"date-time":"2018-10-05T00:00:00Z","timestamp":1538697600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,10,5]],"date-time":"2018-10-05T00:00:00Z","timestamp":1538697600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000104","name":"National Aeronautics and Space Administration","doi-asserted-by":"publisher","award":["NNX14AL37H"],"award-info":[{"award-number":["NNX14AL37H"]}],"id":[{"id":"10.13039\/100000104","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["MCB-1616216"],"award-info":[{"award-number":["MCB-1616216"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100008875","name":"University of Akron","doi-asserted-by":"publisher","award":["Startup fund"],"award-info":[{"award-number":["Startup fund"]}],"id":[{"id":"10.13039\/100008875","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1007\/s11548-018-1865-9","type":"journal-article","created":{"date-parts":[[2018,10,5]],"date-time":"2018-10-05T10:44:17Z","timestamp":1538736257000},"page":"203-213","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":24,"title":["Real-time dual-modal vein imaging system"],"prefix":"10.1007","volume":"14","author":[{"given":"Christopher A.","family":"Mela","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David P.","family":"Lemmer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Forrest Sheng","family":"Bao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francis","family":"Papay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tyler","family":"Hicks","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yang","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,10,5]]},"reference":[{"issue":"8","key":"1865_CR1","doi-asserted-by":"publisher","first-page":"086401","DOI":"10.1117\/1.2009763","volume":"44","author":"H Zeman","year":"2005","unstructured":"Zeman H, Lovhoiden G, Vrancken C, Danish R (2005) Prototype vein contrast enhancer. Opt Eng 44(8):086401. \nhttps:\/\/doi.org\/10.1117\/1.2009763","journal-title":"Opt Eng"},{"issue":"8","key":"1865_CR2","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1111\/j.1524-4725.2006.32226.x","volume":"32","author":"RK Miyake","year":"2006","unstructured":"Miyake RK, Zeman HD, Duarte FH, Kikuchi R, Ramacciotti E, Lovhoiden G, Vrancken C (2006) Vein imaging: a new method of near infrared imaging, where a processed image is projected onto the skin for the enhancement of vein treatment. Dermatol Surg 32(8):1031\u20131038. \nhttps:\/\/doi.org\/10.1111\/j.1524-4725.2006.32226.x","journal-title":"Dermatol Surg"},{"key":"1865_CR3","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1002\/lsm.10248","volume":"34","author":"VP Zharov","year":"2004","unstructured":"Zharov VP, Ferguson S, Eidt JF, Howard PC, Fink LM, Waner M (2004) Infrared imaging of subcutaneous veins. Lasers Surg Med 34:56\u201361. \nhttps:\/\/doi.org\/10.1002\/lsm.10248","journal-title":"Lasers Surg Med"},{"issue":"1","key":"1865_CR4","first-page":"45","volume":"97","author":"R Fuksis","year":"2010","unstructured":"Fuksis R, Greitans M, Nikisins O, Pudzs M (2010) Infrared imaging system for analysis of blood vessel structure. Electron Electr Eng Kaunas Technol 97(1):45\u201348","journal-title":"Electron Electr Eng Kaunas Technol"},{"key":"1865_CR5","doi-asserted-by":"publisher","unstructured":"Crisan S, Tarnovan JG, Crisan TE (2007) A low cost vein detection system using near infrared radiation. In: IEEE sensors applications symposium, San Diego, CA, USA. IEEE. \nhttps:\/\/doi.org\/10.1109\/SAS.2007.374359","DOI":"10.1109\/SAS.2007.374359"},{"key":"1865_CR6","doi-asserted-by":"publisher","unstructured":"Mansoor M, Sravani SN, Naqvi SZ, Badshah I, Saleem M (2013) Real-time low cast infrared vein imaging system. In: International conference on signal processing, image processing and pattern recognition, Coimbatore, India, 2013. IEEE. \nhttps:\/\/doi.org\/10.1109\/ICSIPR.2013.6497970","DOI":"10.1109\/ICSIPR.2013.6497970"},{"key":"1865_CR7","doi-asserted-by":"publisher","unstructured":"Paquita V, Pricea JR, Meriaudeaub F, Tobina KW, Ferrellc TL (2006) Combining near-infrared illuminants to optimize venous imaging. In: Medical imaging 2007: visualization and image-guided procedures, San Diego, CA, USA. SPIE, p 65090H. \nhttps:\/\/doi.org\/10.1117\/12.712576","DOI":"10.1117\/12.712576"},{"key":"1865_CR8","doi-asserted-by":"publisher","unstructured":"Wang L, Leedham G (2006) Near- and far-infrared imaging for vein pattern biometrics. In: IEEE international conference on video and signal based surveillance, Sydney, NSW, Australia. IEEE. \nhttps:\/\/doi.org\/10.1109\/AVSS.2006.80","DOI":"10.1109\/AVSS.2006.80"},{"issue":"3","key":"1865_CR9","doi-asserted-by":"publisher","first-page":"2319","DOI":"10.3390\/s110302319","volume":"11","author":"EC Lee","year":"2011","unstructured":"Lee EC, Jung H, Kim D (2011) New finger biometric method using near infrared imaging. Sensors 11(3):2319\u20132333. \nhttps:\/\/doi.org\/10.3390\/s110302319","journal-title":"Sensors"},{"key":"1865_CR10","doi-asserted-by":"publisher","unstructured":"Michael GKO, Connie T, Teoh ABJ (2011) A contactless biometric system using palm print and palm vein features. In: Chetty G (ed) Advanced biometric technologies. InTech, pp 155\u2013178. \nhttps:\/\/doi.org\/10.1109\/icarcv.2010.5707951","DOI":"10.1109\/icarcv.2010.5707951"},{"key":"1865_CR11","doi-asserted-by":"publisher","first-page":"2401","DOI":"10.1007\/s00268-017-4050-3","volume":"41","author":"EZ Cai","year":"2017","unstructured":"Cai EZ, Sankaran K, Tan M, Chan YH, Lim TC (2017) Pen torch transillumination: difficult venepuncture made easy. World J Surg 41:2401\u20132408. \nhttps:\/\/doi.org\/10.1007\/s00268-017-4050-3","journal-title":"World J Surg"},{"key":"1865_CR12","doi-asserted-by":"publisher","first-page":"433","DOI":"10.1016\/j.medengphy.2012.06.007","volume":"35","author":"NJ Cuper","year":"2013","unstructured":"Cuper NJ, Klaessens JH, Jaspers JE, de Roodea R, Noordmans HJ, de Graaff JC, Verdaasdonk RM (2013) The use of near-infrared light for safe and effective visualization of subsurface blood vessels to facilitate blood withdrawal in children. Med Eng Phys 35:433\u2013440. \nhttps:\/\/doi.org\/10.1016\/j.medengphy.2012.06.007","journal-title":"Med Eng Phys"},{"issue":"7","key":"1865_CR13","doi-asserted-by":"publisher","first-page":"2565","DOI":"10.1364\/BOE.7.002565","volume":"7","author":"D Ai","year":"2016","unstructured":"Ai D, Yang J, Fan J, Zhao Y, Song X, Shen J, Shao L, Wang Y (2016) Augmented reality based real-time subcutaneous vein imaging system. Biomed Opt 7(7):2565\u20132585. \nhttps:\/\/doi.org\/10.1364\/BOE.7.002565","journal-title":"Biomed Opt"},{"issue":"7","key":"1865_CR14","first-page":"2913","volume":"28","author":"M Francis","year":"2017","unstructured":"Francis M, Jose A, Devadhas G, Avinashe K (2017) A novel technique for forearm blood vein detection and enhancement. Biomed Res 28(7):2913\u20132919","journal-title":"Biomed Res"},{"key":"1865_CR15","doi-asserted-by":"publisher","DOI":"10.1142\/s1793545816500516","author":"K Seker","year":"2016","unstructured":"Seker K, Engin M (2016) Deep tissue near-infrared imaging for vascular network analysis. J Innov Opt Health Sci. \nhttps:\/\/doi.org\/10.1142\/s1793545816500516","journal-title":"J Innov Opt Health Sci"},{"key":"1865_CR16","doi-asserted-by":"publisher","DOI":"10.3390\/s17020304","author":"D Kim","year":"2017","unstructured":"Kim D, Kim Y, Yoon S, Lee D (2017) Preliminary study for designing a novel vein-visualizing device. Sensors. \nhttps:\/\/doi.org\/10.3390\/s17020304","journal-title":"Sensors"},{"key":"1865_CR17","doi-asserted-by":"publisher","unstructured":"Lee S, Park S, Lee D (2013) A phantom study on the propagation of NIR rays under the skin for designing a novel vein-visualizing device. In: 13th international conference on control, automation and systems, Gwangui, Korea. IEEE. \nhttps:\/\/doi.org\/10.1109\/ICCAS.2013.6704026","DOI":"10.1109\/ICCAS.2013.6704026"},{"key":"1865_CR18","doi-asserted-by":"publisher","DOI":"10.1002\/0471465380","volume-title":"Introduction to biophotonics","author":"PN Prasad","year":"2003","unstructured":"Prasad PN (2003) Introduction to biophotonics. Wiley, Hoboken"},{"key":"1865_CR19","volume-title":"Photographic techniques in scientific research","author":"A Newman","year":"1976","unstructured":"Newman A (1976) Photographic techniques in scientific research, vol 2. Academic Press, Cambridge"},{"key":"1865_CR20","doi-asserted-by":"publisher","first-page":"920","DOI":"10.1016\/j.patcog.2007.07.012","volume":"41","author":"L Wang","year":"2008","unstructured":"Wang L, Leedham G, Choa DS-Y (2008) Minutiae feature analysis for infrared hand vein pattern biometrics. Pattern Recogn 41:920\u2013929. \nhttps:\/\/doi.org\/10.1016\/j.patcog.2007.07.012","journal-title":"Pattern Recogn"},{"issue":"2","key":"1865_CR21","doi-asserted-by":"publisher","first-page":"294","DOI":"10.1109\/tim.2016.2622860","volume":"66","author":"L Chen","year":"2017","unstructured":"Chen L, Wang J, Yang S, He H (2017) A finger vein image-based personal identification system with self-adaptive illuminance control. IEEE Trans Instrum Meas 66(2):294\u2013304. \nhttps:\/\/doi.org\/10.1109\/tim.2016.2622860","journal-title":"IEEE Trans Instrum Meas"},{"issue":"9","key":"1865_CR22","doi-asserted-by":"publisher","first-page":"884","DOI":"10.1111\/j.1460-9592.2012.03896.x","volume":"22","author":"R Kaddoum","year":"2012","unstructured":"Kaddoum R, Anghelescu D, Parish M, Wright B, Trujillo L, Wu J, Wu Y, Burgoyne L (2012) A randomized controlled trial comparing the AccuVein AV300 device to standard insertion technique for intravenous cannulation of anesthetized children. Paediatr Anaesth 22(9):884\u2013889. \nhttps:\/\/doi.org\/10.1111\/j.1460-9592.2012.03896.x","journal-title":"Paediatr Anaesth"},{"key":"1865_CR23","doi-asserted-by":"publisher","first-page":"119","DOI":"10.5999\/aps.2016.43.1.119","volume":"43","author":"MW Chu","year":"2016","unstructured":"Chu MW, Sarik JR, Wu LC, Serletti JM, Bank J (2016) Non-invasive imaging of preoperative mapping of superficial veins in free flap breast reconstruction. Arch Plast Surg 43:119\u2013121. \nhttps:\/\/doi.org\/10.5999\/aps.2016.43.1.119","journal-title":"Arch Plast Surg"},{"key":"1865_CR24","doi-asserted-by":"publisher","unstructured":"Hebden JC, Alkhaja A, Mahe L, Powell S, Everdell N (2015) Measurement of contrast of phantom and in vivo subsurface blood vessels using two near-infrared imaging systems. In: Optical diagnostics and sensing XV: toward point-of-care diagnostics, San Francisco, CA, USA. SPIE, p 933213. \nhttps:\/\/doi.org\/10.1117\/12.2084673","DOI":"10.1117\/12.2084673"},{"key":"1865_CR25","doi-asserted-by":"publisher","DOI":"10.1117\/1.JBO.18.5.050504","author":"F Wang","year":"2013","unstructured":"Wang F, Behrooz A, Morris M, Adibi A (2013) High-contrast subcutaneous vein detection and localization using multispectral imaging. J Biomed Opt. \nhttps:\/\/doi.org\/10.1117\/1.JBO.18.5.050504","journal-title":"J Biomed Opt"},{"issue":"14","key":"1865_CR26","doi-asserted-by":"publisher","first-page":"11360","DOI":"10.1109\/ICIP.2009.5414511","volume":"16","author":"V Paquit","year":"2009","unstructured":"Paquit V, Tobin K, Price J, M\u00e8riaudeau F (2009) 3D and multispectral imaging for subcutaneous veins detection. Opt Express 16(14):11360\u201311365. \nhttps:\/\/doi.org\/10.1109\/ICIP.2009.5414511","journal-title":"Opt Express"},{"key":"1865_CR27","doi-asserted-by":"publisher","first-page":"388","DOI":"10.1007\/978-3-319-46726-9_45","volume-title":"Lecture Notes in Computer Science","author":"Alvin I. Chen","year":"2016","unstructured":"Chen AI, Balter ML, Maguire TJ, Yarmush ML (2016) 3D near infrared and ultrasound imaging of peripheral blood vessels for real-time localization and needle guidance. In: Ourselin S, Joskowicz L, Sabuncu M, Unal G, Wells W (eds) Medical image computing and computer-assisted intervention, Athens, Greece. Lecture notes in computer science. Springer, pp 388\u2013396. \nhttps:\/\/doi.org\/10.1007\/978-3-319-46726-9_45"},{"key":"1865_CR28","doi-asserted-by":"publisher","unstructured":"Ahmed T, Rahman KS, Shawlin SS, Hasan M, Bhattacharjee A, Fattah SA, Shahnaz C (2017) Real time injecting device with automated robust vein detection using near infrared camera and live video. In: Global humanitarian technology conference (GHTC), San Jose, CA, USA. IEEE. \nhttps:\/\/doi.org\/10.1109\/GHTC.2017.8239298","DOI":"10.1109\/GHTC.2017.8239298"},{"key":"1865_CR29","doi-asserted-by":"publisher","first-page":"83","DOI":"10.1097\/PEC.0b013e318163db5f","volume":"24","author":"Y Katsogridakis","year":"2008","unstructured":"Katsogridakis Y, Seshadri R, Sullivan C, Waltzman M (2008) Veinlite transillumination in the pediatric emergency department: a therapeutic interventional trial. Pediatr Emerg Care 24:83\u201388. \nhttps:\/\/doi.org\/10.1097\/PEC.0b013e318163db5f","journal-title":"Pediatr Emerg Care"},{"key":"1865_CR30","doi-asserted-by":"publisher","first-page":"37","DOI":"10.1007\/s00238-015-1165-3","volume":"39","author":"M Nizamoglu","year":"2016","unstructured":"Nizamoglu M, Tan A, Gerrish H, Barnes D, Dziewulski P (2016) Infrared technology to improve efficacy of venous access in burns population. Eur J Plast Surg 39:37\u201340. \nhttps:\/\/doi.org\/10.1007\/s00238-015-1165-3","journal-title":"Eur J Plast Surg"},{"issue":"6","key":"1865_CR31","doi-asserted-by":"publisher","first-page":"1066","DOI":"10.1016\/j.jos.2017.07.004","volume":"22","author":"T Nakasa","year":"2017","unstructured":"Nakasa T, Ishikawa M, Ikuta Y, Yoshikawa M, Sawa M, Tsuyuguchi Y, Adachi N (2017) In-vivo imaging of the sentinel vein using the near-infrared vascular imaging system in hallux valgus patients. J Orthop Sci 22(6):1066\u20131070. \nhttps:\/\/doi.org\/10.1016\/j.jos.2017.07.004","journal-title":"J Orthop Sci"},{"issue":"4","key":"1865_CR32","doi-asserted-by":"publisher","first-page":"273","DOI":"10.1177\/1043454215600425","volume":"33","author":"L Ramer","year":"2016","unstructured":"Ramer L, Hunt P, Ortega E, Knowlton J, Briggs R, Hirokawa S (2016) Effect of intravenous (IV) assistive device (VeinViewer) on IV access attempts, procedural time, and patient and nurse satisfaction. J Pediatr Oncol Nurs 33(4):273\u2013281. \nhttps:\/\/doi.org\/10.1177\/1043454215600425","journal-title":"J Pediatr Oncol Nurs"},{"key":"1865_CR33","doi-asserted-by":"publisher","unstructured":"Bandara A, Rajarata K, Giragama P (2017) Super-efficient spatially adaptive contrast enhancement algorithm for superficial vein imaging. In: IEEE international conference on industrial and information systems, Peradeniya, Sri Lanka. IEEE. \nhttps:\/\/doi.org\/10.1109\/iciinfs.2017.8300427","DOI":"10.1109\/iciinfs.2017.8300427"},{"key":"1865_CR34","doi-asserted-by":"publisher","unstructured":"Yakno M, Saleh JM, Rosdi BA (2011) Low contrast hand vein image enhancement. In: IEEE international conference on signal and image processing applications, Kuala Lumpur, Malaysia. IEEE. \nhttps:\/\/doi.org\/10.1109\/ICSIPA.2011.6144135","DOI":"10.1109\/ICSIPA.2011.6144135"},{"issue":"34","key":"1865_CR35","doi-asserted-by":"publisher","first-page":"D67","DOI":"10.1364\/AO.55.000D67","volume":"55","author":"M Asrar","year":"2016","unstructured":"Asrar M, Al-Habaibeh A, Houda M (2016) Innovative algorithm to evaluate the capabilities of visual, near infrared, and infrared technologies for the detection of veins for intravenous cannulation. Appl Opt 55(34):D67\u2013D75. \nhttps:\/\/doi.org\/10.1364\/AO.55.000D67","journal-title":"Appl Opt"},{"key":"1865_CR36","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1016\/S0734-189X(87)80186-X","volume":"39","author":"S Pizer","year":"1987","unstructured":"Pizer S, Amburn E, Austin J, Cromartie R, Geselowitz A, Greer T, ter Haar Romeny B, Zimmerman J, Zuiderveld K (1987) Adaptive histogram equalization and its variations. Comput Vis Graph Image Proc 39:355\u2013368. \nhttps:\/\/doi.org\/10.1016\/S0734-189X(87)80186-X","journal-title":"Comput Vis Graph Image Proc"},{"issue":"1","key":"1865_CR37","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1023\/B:VLSI.0000028532.53893.82","volume":"38","author":"A Reza","year":"2004","unstructured":"Reza A (2004) Realization of the contrast limited adaptive histogram equalization (CLAHE) for real-time image enhancement. J VLSI Signal Process Syst Signal Image Video Technol 38(1):35\u201344. \nhttps:\/\/doi.org\/10.1023\/B:VLSI.0000028532.53893.82","journal-title":"J VLSI Signal Process Syst Signal Image Video Technol"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1865-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1865-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1865-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T21:42:44Z","timestamp":1589665364000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1865-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,5]]},"references-count":37,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["1865"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1865-9","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,5]]},"assertion":[{"value":"6 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}},{"value":"Informed consent was obtained from all individual participants included in the study. Additional informed consent was obtained from all individual participants for whom identifying information is included in this article.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}