{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,20]],"date-time":"2026-06-20T15:42:12Z","timestamp":1781970132894,"version":"3.54.5"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T00:00:00Z","timestamp":1538611200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T00:00:00Z","timestamp":1538611200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100000001","name":"National Science Foundation","doi-asserted-by":"publisher","award":["00039202"],"award-info":[{"award-number":["00039202"]}],"id":[{"id":"10.13039\/100000001","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1007\/s11548-018-1866-8","type":"journal-article","created":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T15:16:32Z","timestamp":1538666192000},"page":"117-127","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":10,"title":["Conditions for reliable grip force and jaw angle estimation of da Vinci surgical tools"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9974-4090","authenticated-orcid":false,"given":"Trevor K.","family":"Stephens","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John J.","family":"O\u2019Neill","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nathan J.","family":"Kong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark V.","family":"Mazzeo","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jack E.","family":"Norfleet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert M.","family":"Sweet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Timothy M.","family":"Kowalewski","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2018,10,4]]},"reference":[{"key":"1866_CR1","doi-asserted-by":"crossref","unstructured":"Anooshahpour F, Polushin IG, Patel RV (2014) Quasi-static modeling of the da Vinci instrument. In: International conference on intelligent robots and systems (IROS). IEEE, pp 1308\u20131313","DOI":"10.1109\/IROS.2014.6942726"},{"issue":"3","key":"1866_CR2","doi-asserted-by":"publisher","first-page":"030934","DOI":"10.1115\/1.4033854","volume":"10","author":"V Barocas","year":"2016","unstructured":"Barocas V, Tenorio LM, Devine K, Lee J, Sweet R, Norfleet J, Mazzeo M (2016) A paradigm for materials design for surgical simulators, with specific application to the pleura and needle decompression. J Med Dev 10(3):030934","journal-title":"J Med Dev"},{"issue":"2","key":"1866_CR3","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1109\/MCG.2004.1274062","volume":"24","author":"C Basdogan","year":"2004","unstructured":"Basdogan C, De S, Kim J, Muniyandi M, Kim H, Srinivasan MA (2004) Haptics in minimally invasive surgical simulation and training. IEEE Comput Graph Appl 24(2):56\u201364","journal-title":"IEEE Comput Graph Appl"},{"issue":"11\u201312","key":"1866_CR4","doi-asserted-by":"publisher","first-page":"1159","DOI":"10.1177\/0278364907082847","volume":"26","author":"S De","year":"2007","unstructured":"De S, Rosen J, Dagan A, Hannaford B, Swanson P, Sinanan M (2007) Assessment of tissue damage due to mechanical stresses. Int J Robot Res 26(11\u201312):1159\u20131171","journal-title":"Int J Robot Res"},{"key":"1866_CR5","unstructured":"Dockter R, O\u2019Neill J, Stephens T, Kowalewski T (2016) Feasibility of tissue classification via da Vinci endowrist surgical tool. In: Hamlyn symposium on medical robotics, pp 64\u201365"},{"issue":"2","key":"1866_CR6","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.medengphy.2007.02.007","volume":"30","author":"V Egorov","year":"2008","unstructured":"Egorov V, Tsyuryupa S, Kanilo S, Kogit M, Sarvazyan A (2008) Soft tissue elastometer. Med Eng Phys 30(2):206\u2013212","journal-title":"Med Eng Phys"},{"key":"1866_CR7","first-page":"1930","volume":"3","author":"FD Foresee","year":"1997","unstructured":"Foresee FD, Hagan MT (1997) Gauss\u2013Newton approximation to Bayesian learning. IEEE Int Conf Neural Netw 3:1930\u20131935","journal-title":"IEEE Int Conf Neural Netw"},{"key":"1866_CR8","unstructured":"Hecht-Nielsen R (1987) Kolmogorov\u2019s mapping neural network existence theorem. In: Proceedings of the international conference on neural networks. IEEE Press, pp 11\u201314"},{"key":"1866_CR9","unstructured":"Holoborodko P (2008) Smooth noise robust differentiators. \n                    http:\/\/HrBwww.holoborodko.com\/pavel\/numerical-methods\/numerical-deriHrBvative\/smooth-low-noise-differentiators\/"},{"key":"1866_CR10","doi-asserted-by":"publisher","DOI":"10.1089\/end.2017.0894","author":"D Jones","year":"2018","unstructured":"Jones D, Jaffer A, Nodeh AA, Biyani CS, Culmer P (2018) Analysis of mechanical forces used during laparoscopic training procedures. J Endourol. \n                    https:\/\/doi.org\/10.1089\/end.2017.0894","journal-title":"J Endourol"},{"key":"1866_CR11","doi-asserted-by":"crossref","unstructured":"Kehoe B, Kahn G, Mahler J, Kim J, Lee A, Lee A, Nakagawa K, Patil S, Boyd WD, Abbeel P, Goldberg K (2014) Autonomous multilateral debridement with the raven surgical robot. In: International conference on robotics and automation (ICRA). IEEE, pp 1432\u20131439","DOI":"10.1109\/ICRA.2014.6907040"},{"issue":"5","key":"1866_CR12","doi-asserted-by":"publisher","first-page":"1214","DOI":"10.1109\/TRO.2015.2473515","volume":"31","author":"U Kim","year":"2015","unstructured":"Kim U, Lee DH, Yoon WJ, Hannaford B, Choi HR (2015) Force sensor integrated surgical forceps for minimally invasive robotic surgery. IEEE Trans Robot 31(5):1214\u20131224","journal-title":"IEEE Trans Robot"},{"key":"1866_CR13","doi-asserted-by":"crossref","unstructured":"Kim U, Kim YB, Seok DY, So J, Choi HR (2016) A new type of surgical forceps integrated with three-axial force sensor for minimally invasive robotic surgery. In: 2016 13th international conference on ubiquitous robots and ambient intelligence (URAI). IEEE, pp 135\u2013137","DOI":"10.1109\/URAI.2016.7734039"},{"key":"1866_CR14","unstructured":"Kong NJ, Stephens TK, ONeill JJ, Kowalewski TM (2017) Design of a portable dynamic calibration instrument for da Vinci Si tools. In: 2017 design of medical devices conference. American Society of Mechanical Engineers, pp V001T11A023\u2013V001T11A023"},{"key":"1866_CR15","doi-asserted-by":"crossref","unstructured":"Kong NJ, Stephens TK, Kowalewski TM (2018) Da Vinci tool torque mapping over 50,000 grasps and its implications on grip force estimation accuracy. In: 2018 international symposium on medical robotics (ISMR). IEEE, pp 1\u20136","DOI":"10.1109\/ISMR.2018.8333292"},{"issue":"4","key":"1866_CR16","doi-asserted-by":"publisher","first-page":"998","DOI":"10.1016\/j.juro.2015.10.087","volume":"195","author":"TM Kowalewski","year":"2016","unstructured":"Kowalewski TM, Sweet R, Lendvay TS, Menhadji A, Averch T, Box G, Brand T, Ferrandino M, Kaouk J, Knudsen B, Landman J, Lee B, Schwartz B, McDougall E (2016) Validation of the aua blus tasks. J Urol 195(4):998\u20131005","journal-title":"J Urol"},{"issue":"1","key":"1866_CR17","doi-asserted-by":"publisher","first-page":"14","DOI":"10.1097\/01.sla.0000103020.19595.7d","volume":"239","author":"AR Lanfranco","year":"2004","unstructured":"Lanfranco AR, Castellanos AE, Desai JP, Meyers WC (2004) Robotic surgery: a current perspective. Ann Surg 239(1):14\u201321","journal-title":"Ann Surg"},{"issue":"3","key":"1866_CR18","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1007\/s11517-014-1230-2","volume":"53","author":"C Lee","year":"2015","unstructured":"Lee C, Park YH, Yoon C, Noh S, Lee C, Kim Y, Kim HC, Kim HH, Kim S (2015) A grip force model for the da vinci end-effector to predict a compensation force. Med Biol Eng Comput 53(3):253\u2013261","journal-title":"Med Biol Eng Comput"},{"issue":"3","key":"1866_CR19","doi-asserted-by":"publisher","first-page":"1312","DOI":"10.1109\/LRA.2017.2666420","volume":"2","author":"Y Li","year":"2017","unstructured":"Li Y, Hannaford B (2017) Gaussian process regression for sensorless grip force estimation of cable-driven elongated surgical instruments. IEEE Robot Autom Lett 2(3):1312\u20131319","journal-title":"IEEE Robot Autom Lett"},{"key":"1866_CR20","doi-asserted-by":"crossref","unstructured":"Li Y, Miyasaka M, Haghighipanah M, Cheng L, Hannaford B (2016) Dynamic modeling of cable driven elongated surgical instruments for sensorless grip force estimation. In: International conference on robotics and automation (ICRA). IEEE, pp 4128\u20134134","DOI":"10.1109\/ICRA.2016.7487605"},{"issue":"3","key":"1866_CR21","doi-asserted-by":"publisher","first-page":"448","DOI":"10.1162\/neco.1992.4.3.448","volume":"4","author":"DJ MacKay","year":"1992","unstructured":"MacKay DJ (1992) A practical Bayesian framework for backpropagation networks. Neural Comput 4(3):448\u2013472","journal-title":"Neural Comput"},{"issue":"3","key":"1866_CR22","doi-asserted-by":"publisher","first-page":"523","DOI":"10.1089\/end.2010.0306","volume":"25","author":"P Mucksavage","year":"2011","unstructured":"Mucksavage P, Kerbl DC, Pick DL, Lee JY, McDougall EM, Louie MK (2011) Differences in grip forces among various robotic instruments and da Vinci surgical platforms. J Endourol 25(3):523\u2013528","journal-title":"J Endourol"},{"key":"1866_CR23","doi-asserted-by":"crossref","unstructured":"Nakai A, Kuwana K, Saito K, Dohi T, Kumagai A, Shimoyama I (2017) Mems 6-axis force-torque sensor attached to the tip of grasping forceps for identification of tumor in thoracoscopic surgery. In: 2017 IEEE 30th international conference on micro electro mechanical systems (MEMS). IEEE, pp 546\u2013548","DOI":"10.1109\/MEMSYS.2017.7863464"},{"issue":"4","key":"1866_CR24","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1109\/JSEN.2008.917481","volume":"8","author":"P Puangmali","year":"2008","unstructured":"Puangmali P, Althoefer K, Seneviratne LD, Murphy D, Dasgupta P (2008) State-of-the-art in force and tactile sensing for minimally invasive surgery. IEEE Sens J 8(4):371\u2013381","journal-title":"IEEE Sens J"},{"issue":"337","key":"1866_CR25","doi-asserted-by":"publisher","first-page":"337ra64","DOI":"10.1126\/scitranslmed.aad9398","volume":"8","author":"A Shademan","year":"2016","unstructured":"Shademan A, Decker RS, Opfermann JD, Leonard S, Krieger A, Kim PC (2016) Supervised autonomous robotic soft tissue surgery. Sci Transl Med 8(337):337ra64","journal-title":"Sci Transl Med"},{"issue":"6","key":"1866_CR26","doi-asserted-by":"publisher","first-page":"769","DOI":"10.1007\/s11548-018-1745-3","volume":"13","author":"T Stephens","year":"2018","unstructured":"Stephens T, Kong N, Dockter R, O\u2019Neill J, Sweet R, Kowalewski T (2018) Blended shared control utilizing online identification: regulating grasping forces of a surrogate surgical grasper. Int J Comput Assist Radiol Surg 13(6):769\u2013776","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"1866_CR27","first-page":"030939","volume":"9","author":"TK Stephens","year":"2015","unstructured":"Stephens TK, Meier ZC, Sweet RM, Kowalewski TM (2015) Tissue identification through back end sensing on da Vinci endowrist surgical tool. J Med Dev Tech Brief 9(3):030939","journal-title":"J Med Dev Tech Brief"},{"key":"1866_CR28","doi-asserted-by":"crossref","unstructured":"Yamamoto T, Vagvolgyi B, Balaji K, Whitcomb LL, Okamura AM (2009) Tissue property estimation and graphical display for teleoperated robot-assisted surgery. In: International conference on robotics and automation (ICRA). IEEE, pp 4239\u20134245","DOI":"10.1109\/ROBOT.2009.5152674"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1866-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1866-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1866-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,16]],"date-time":"2020-05-16T21:42:04Z","timestamp":1589665324000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1866-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,4]]},"references-count":28,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["1866"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1866-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,4]]},"assertion":[{"value":"30 March 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"24 September 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical standard"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}