{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:25:46Z","timestamp":1740144346889,"version":"3.37.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,10,6]],"date-time":"2018-10-06T00:00:00Z","timestamp":1538784000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100000781","name":"European Research Council","doi-asserted-by":"publisher","award":["320378 \u2013 SNLSID"],"award-info":[{"award-number":["320378 \u2013 SNLSID"]}],"id":[{"id":"10.13039\/501100000781","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1007\/s11548-018-1869-5","type":"journal-article","created":{"date-parts":[[2018,10,6]],"date-time":"2018-10-06T02:47:58Z","timestamp":1538794078000},"page":"129-137","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Tactile sensor-based real-time clustering for tissue differentiation"],"prefix":"10.1007","volume":"14","author":[{"given":"Ralf","family":"Stroop","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Makoto","family":"Nakamura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johan","family":"Schoukens","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5532-7145","authenticated-orcid":false,"given":"David","family":"Oliva Uribe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2018,10,6]]},"reference":[{"issue":"3","key":"1869_CR1","doi-asserted-by":"publisher","first-page":"175","DOI":"10.1615\/CritRevBiomedEng.v40.i3.20","volume":"40","author":"D Kuhnt","year":"2012","unstructured":"Kuhnt D, Bauer MHA, Nimsky C (2012) Brain shift compensation and neurosurgical image fusion using intraoperative MRI: current status and future challenges. Crit Rev Biomed Eng 40(3):175\u2013185","journal-title":"Crit Rev Biomed Eng"},{"issue":"6","key":"1869_CR2","doi-asserted-by":"publisher","first-page":"572","DOI":"10.1055\/s-0031-1273443","volume":"32","author":"K Leyen van","year":"2011","unstructured":"van Leyen K, Klotzsch C, Harrer JU (2011) Brain tumor imaging with transcranial sonography: state of the art and review of the literature. Ultraschall in der Medizin 32(6):572\u2013581","journal-title":"Ultraschall in der Medizin"},{"issue":"3","key":"1869_CR3","doi-asserted-by":"publisher","first-page":"327","DOI":"10.1002\/rcs.1425","volume":"8","author":"M Finke","year":"2012","unstructured":"Finke M, Kantelhardt S, Schlaefer A, Bruder R, Lankenau E, Giese A, Schweikard A (2012) Automatic scanning of large tissue areas in neurosurgery using optical coherence tomography. Int J Med Robot Comput Assist Surg MRCAS 8(3):327\u2013336","journal-title":"Int J Med Robot Comput Assist Surg MRCAS"},{"issue":"4","key":"1869_CR4","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1007\/s00216-010-4116-7","volume":"398","author":"M Kirsch","year":"2010","unstructured":"Kirsch M, Schackert G, Salzer R, Krafft C (2010) Raman spectroscopic imaging for in vivo detection of cerebral brain metastases. Anal Bioanal Chem 398(4):1707\u20131713","journal-title":"Anal Bioanal Chem"},{"issue":"1","key":"1869_CR5","doi-asserted-by":"publisher","first-page":"16001","DOI":"10.1117\/1.3528011","volume":"16","author":"G Steiner","year":"2011","unstructured":"Steiner G, Sobottka SB, Koch E, Schackert G, Kirsch M (2011) Intraoperative imaging of cortical cerebral perfusion by time-resolved thermography and multivariate data analysis. J Biomed Opt 16(1):16001","journal-title":"J Biomed Opt"},{"issue":"12","key":"1869_CR6","doi-asserted-by":"publisher","first-page":"1611","DOI":"10.1016\/j.jocn.2012.03.013","volume":"19","author":"MJ Colditz","year":"2012","unstructured":"Colditz MJ, van Leyen K, Jeffree RL (2012) Aminolevulinic acid (ALA)-protoporphyrin IX fluorescence guided tumour resection. Part 2: theoretical, biochemical and practical aspects. J Clin Neurosci 19(12):1611\u20131616","journal-title":"J Clin Neurosci"},{"key":"1869_CR7","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-540-88248-0","volume-title":"Engineering haptic devices: a beginner\u2019s guide for engineers","author":"TA Kern","year":"2009","unstructured":"Kern TA (2009) Engineering haptic devices: a beginner\u2019s guide for engineers. Springer, Dordrecht"},{"issue":"1","key":"1869_CR8","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/S0957-4158(98)00045-2","volume":"9","author":"MH Lee","year":"1999","unstructured":"Lee MH, Nicholls HR (1999) Review article tactile sensing for mechatronics\u2014a state of the art survey. Mechatronics 9(1):1\u201331","journal-title":"Mechatronics"},{"issue":"10","key":"1869_CR9","doi-asserted-by":"publisher","first-page":"1163","DOI":"10.1016\/S0957-4158(03)00048-5","volume":"13","author":"MEH Eltaib","year":"2003","unstructured":"Eltaib MEH, Hewit JR (2003) Tactile sensing technology for minimal access surgery\u2014a review. Mechatronics 13(10):1163\u20131177","journal-title":"Mechatronics"},{"issue":"8","key":"1869_CR10","first-page":"32","volume":"143","author":"RA Rahim","year":"2012","unstructured":"Rahim RA, Waduth MFA, Jaafar HI, Ayob NMN, Leow PL (2012) Current trend of tactile sensor in advanced applications. Sens Transducers 143(8):32\u201343","journal-title":"Sens Transducers"},{"key":"1869_CR11","doi-asserted-by":"publisher","first-page":"17","DOI":"10.1016\/j.sna.2012.02.051","volume":"179","author":"MI Tiwana","year":"2012","unstructured":"Tiwana MI, Redmond SJ, Lovell NH (2012) A review of tactile sensing technologies with applications in biomedical engineering. Sens Actuators A 179:17\u201331","journal-title":"Sens Actuators A"},{"issue":"2","key":"1869_CR12","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.3390\/s130201435","volume":"13","author":"C Lucarotti","year":"2013","unstructured":"Lucarotti C, Oddo CM, Vitiello N, Carrozza MC (2013) Synthetic and bio-artificial tactile sensing: a review. Sensors 13(2):1435\u20131466","journal-title":"Sensors"},{"issue":"4","key":"1869_CR13","doi-asserted-by":"publisher","first-page":"422","DOI":"10.3390\/bios4040422","volume":"4","author":"P Saccomandi","year":"2014","unstructured":"Saccomandi P, Schena E, Oddo C, Zollo L, Silvestri S, Guglielmelli E (2014) Microfabricated tactile sensors for biomedical applications: a review. Biosensors 4(4):422\u2013448","journal-title":"Biosensors"},{"issue":"8","key":"1869_CR14","doi-asserted-by":"publisher","first-page":"1486","DOI":"10.1109\/JSEN.2008.920723","volume":"8","author":"C Bonomo","year":"2008","unstructured":"Bonomo C, Brunetto P, Fortuna L, Giannone P, Graziani S, Strazzeri S (2008) A tactile sensor for biomedical applications based on IPMCs. IEEE Sens J 8(8):1486\u20131493","journal-title":"IEEE Sens J"},{"issue":"5","key":"1869_CR15","doi-asserted-by":"publisher","first-page":"1453","DOI":"10.1109\/TIM.2009.2038297","volume":"59","author":"P Brunetto","year":"2010","unstructured":"Brunetto P, Fortuna L, Giannone P, Graziani S, Pagano F (2010) A resonant vibrating tactile probe for biomedical applications based on IPMC. IEEE Trans Instrum Meas 59(5):1453\u20131462","journal-title":"IEEE Trans Instrum Meas"},{"issue":"3\u20135","key":"1869_CR16","doi-asserted-by":"publisher","first-page":"441","DOI":"10.1016\/j.jsv.2007.03.063","volume":"308","author":"T Hemsel","year":"2007","unstructured":"Hemsel T, Stroop R, Uribe DO, Wallaschek J (2007) Resonant vibrating sensors for tactile tissue differentiation. J Sound Vib 308(3\u20135):441\u2013446","journal-title":"J Sound Vib"},{"issue":"4","key":"1869_CR17","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s11548-010-0426-7","volume":"5","author":"Y Tanaka","year":"2010","unstructured":"Tanaka Y, Yu Q, Doumoto K, Sano A, Hayashi Y, Fujii M, Kajita Y, Mizuno M, Wakabayashi T, Fujimoto H (2010) Development of a real-time tactile sensing system for brain tumor diagnosis. Int J Comput Assist Radiol Surg 5(4):359\u2013367","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1869_CR18","doi-asserted-by":"publisher","first-page":"25","DOI":"10.1016\/j.sna.2012.10.039","volume":"190","author":"D Johannsmann","year":"2013","unstructured":"Johannsmann D, Langhoff A, Bode B, Mpoukouvalas K, Heimann A, Kempski O, Charalampaki P (2013) Towards in vivo differentiation of brain tumor versus normal tissue by means of torsional resonators. Sens Actuators A 190:25\u201331","journal-title":"Sens Actuators A"},{"key":"1869_CR19","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1016\/j.ymssp.2017.07.007","volume":"99","author":"DO Uribe","year":"2018","unstructured":"Uribe DO, Schoukens J, Stroop R (2018) Improved tactile resonance sensor for robotic assisted surgery. Mech Syst Signal Process 99:600\u2013610","journal-title":"Mech Syst Signal Process"},{"key":"1869_CR20","doi-asserted-by":"crossref","unstructured":"Uribe DO, Stroop R, Wallaschek J (2009) Piezoelectric self-sensing system for tactile intraoperative brain tumor delineation in neurosurgery. In: Conference proceedings: annual international conference of the IEEE engineering in medicine and biology society, vol 2009. IEEE Engineering in Medicine and Biology Society, pp 737\u2013740","DOI":"10.1109\/IEMBS.2009.5332409"},{"key":"1869_CR21","doi-asserted-by":"crossref","unstructured":"Uribe DO, Zhu H, Wallaschek J (2010) Automated measurement system for mechanical characterization of soft tissues and phantoms. In: 2010 International conference on electronic devices, systems and applications (ICEDSA), pp 227\u2013231","DOI":"10.1109\/ICEDSA.2010.5503068"},{"issue":"23","key":"1869_CR22","doi-asserted-by":"publisher","first-page":"5597","DOI":"10.1088\/0031-9155\/50\/23\/013","volume":"50","author":"EL Madsen","year":"2005","unstructured":"Madsen EL, Hobson MA, Shi H, Varghese T, Frank GR (2005) Tissue-mimicking agar\/gelatin materials for use in heterogeneous elastography phantoms. Phys Med Biol 50(23):5597\u20135618","journal-title":"Phys Med Biol"},{"issue":"4","key":"1869_CR23","doi-asserted-by":"publisher","first-page":"893","DOI":"10.1109\/TIM.2009.2026613","volume":"59","author":"P Brunetto","year":"2010","unstructured":"Brunetto P, Fortuna L, Giannone P, Graziani S, Strazzeri S (2010) Static and dynamic characterization of the temperature and humidity influence on IPMC actuators. IEEE Trans Instrum Meas 59(4):893\u2013908","journal-title":"IEEE Trans Instrum Meas"},{"issue":"1","key":"1869_CR24","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1109\/19.206670","volume":"42","author":"I Kollar","year":"1993","unstructured":"Kollar I (1993) On frequency-domain identification of linear systems. IEEE Trans Instrum Meas 42(1):2\u20136","journal-title":"IEEE Trans Instrum Meas"},{"issue":"1","key":"1869_CR25","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.mechmat.2004.03.002","volume":"37","author":"L Cheng","year":"2005","unstructured":"Cheng L, Xia X, Scriven LE, Gerberich WW (2005) Spherical-tip indentation of viscoelastic material. Mech Mater 37(1):213\u2013226","journal-title":"Mech Mater"},{"key":"1869_CR26","volume-title":"Multivariate observations","author":"GAF Seber","year":"2004","unstructured":"Seber GAF (2004) Multivariate observations. Wiley, New York"},{"issue":"7","key":"1869_CR27","doi-asserted-by":"publisher","first-page":"755","DOI":"10.1002\/nbm.1254","volume":"21","author":"MA Green","year":"2008","unstructured":"Green MA, Bilston LE, Sinkus R (2008) In vivo brain viscoelastic properties measured by magnetic resonance elastography. NMR Biomed 21(7):755\u2013764","journal-title":"NMR Biomed"},{"issue":"12","key":"1869_CR28","doi-asserted-by":"publisher","first-page":"1373","DOI":"10.1088\/0967-3334\/27\/12\/009","volume":"27","author":"V Jalkanen","year":"2006","unstructured":"Jalkanen V, Andersson BM, Bergh A, Ljungberg B, Lindahl OA (2006) Resonance sensor measurements of stiffness variations in prostate tissue in vitro\u2014a weighted tissue proportion model. Physiol Meas 27(12):1373\u20131386","journal-title":"Physiol Meas"},{"key":"1869_CR29","doi-asserted-by":"publisher","DOI":"10.4236\/ojbiphy.2014.41004","author":"T Sasaki","year":"2014","unstructured":"Sasaki T, Haruta M, Omata S (2014) Ct elastography: a pilot study via a new endoscopic tactile sensor. Open J Biophys. \n                    https:\/\/doi.org\/10.4236\/ojbiphy.2014.41004","journal-title":"Open J Biophys"},{"key":"1869_CR30","doi-asserted-by":"publisher","DOI":"10.1016\/0924-4247(92)87002-X","author":"S Omata","year":"1992","unstructured":"Omata S, Terunuma Y (1992) New tactile sensor like the human hand and its applications. Sens Actuators A. \n                    https:\/\/doi.org\/10.1016\/0924-4247(92)87002-X","journal-title":"Sens Actuators A"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1869-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1869-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1869-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,10,5]],"date-time":"2019-10-05T19:10:53Z","timestamp":1570302653000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1869-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,6]]},"references-count":30,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["1869"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1869-5","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2018,10,6]]},"assertion":[{"value":"13 May 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 September 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Research involving human participants and\/or animals"}},{"value":"For this type of study, formal consent is not required. This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}