{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,14]],"date-time":"2026-02-14T06:44:19Z","timestamp":1771051459432,"version":"3.50.1"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2018,10,13]],"date-time":"2018-10-13T00:00:00Z","timestamp":1539388800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1007\/s11548-018-1870-z","type":"journal-article","created":{"date-parts":[[2018,10,13]],"date-time":"2018-10-13T00:49:14Z","timestamp":1539391754000},"page":"281-289","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":31,"title":["An oral and maxillofacial navigation system for implant placement with automatic identification of fiducial points"],"prefix":"10.1007","volume":"14","author":[{"given":"Chunxia","family":"Qin","sequence":"first","affiliation":[]},{"given":"Zhenggang","family":"Cao","sequence":"additional","affiliation":[]},{"given":"Shengchi","family":"Fan","sequence":"additional","affiliation":[]},{"given":"Yiqun","family":"Wu","sequence":"additional","affiliation":[]},{"given":"Yi","family":"Sun","sequence":"additional","affiliation":[]},{"given":"Constantinus","family":"Politis","sequence":"additional","affiliation":[]},{"given":"Chunliang","family":"Wang","sequence":"additional","affiliation":[]},{"given":"Xiaojun","family":"Chen","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,10,13]]},"reference":[{"issue":"12","key":"1870_CR1","doi-asserted-by":"crossref","first-page":"947","DOI":"10.1007\/s00106-006-1401-z","volume":"54","author":"G Strauss","year":"2006","unstructured":"Strauss G, Koulechov K, R\u00f6ttger S, Bahner J, Trantakis C, Hofer M (2006) Clinical efficiency and the influence of human factors on ear, nose, and throat navigation systems. Hno 54(12):947\u2013957","journal-title":"Hno"},{"issue":"1","key":"1870_CR2","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1080\/13645700310001577","volume":"12","author":"M Caversaccio","year":"2003","unstructured":"Caversaccio M, Freysinger W (2003) Computer assistance for intraoperative navigation in ENT surgery. Minim Invasive Ther Allied Technol 12(1):36\u201351","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"1870_CR3","doi-asserted-by":"crossref","first-page":"81","DOI":"10.1016\/j.medengphy.2017.01.005","volume":"41","author":"X Chen","year":"2017","unstructured":"Chen X, Xu L, Wang H, Wang F, Wang Q, Kikinis R (2017) Development of a surgical navigation system based on 3D Slicer for intraoperative implant placement surgery. Med Eng Phys 41:81\u201389","journal-title":"Med Eng Phys"},{"issue":"3","key":"1870_CR4","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/j.jdsr.2018.03.005","volume":"4","author":"S Sukegawa","year":"2018","unstructured":"Sukegawa S, Kanno T, Furuki Y (2018) Application of computer-assisted navigation systems in oral and maxillofacial surgery. Jpn Dent Sci Rev 4(3):139\u2013149","journal-title":"Jpn Dent Sci Rev"},{"key":"1870_CR5","first-page":"36","volume":"196","author":"T Brennecke","year":"2014","unstructured":"Brennecke T, Jansen N, Raczkowsky J, Schipper J, Woern H (2014) An ultrasound-based navigation system for minimally invasive neck surgery. Stud Health Technol Inform 196:36\u201342","journal-title":"Stud Health Technol Inform"},{"issue":"5","key":"1870_CR6","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1007\/s11548-014-0980-5","volume":"9","author":"R Balachandran","year":"2014","unstructured":"Balachandran R, Fritz MA, Dietrich MS, Danilchenko A, Mitchell JE, Oldfield VL, Lipscomb WW, Fitzpatrick JM, Neimat JS, Konrad PE, Labadie RF (2014) Clinical testing of an alternate method of inserting bone-implanted fiducial markers. Int J Comput Assist Radiol Surg 9(5):913\u2013920","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1870_CR7","first-page":"2","volume":"9036","author":"JP Kobler","year":"2014","unstructured":"Kobler JP, D\u00edaz JD, Fitzpatrick JM, Lexow GJ, Majdani O, Ortmaier T (2014) Localization accuracy of sphere fiducials in computed tomography images. Proc SPIE 9036:2\u20137","journal-title":"Proc SPIE"},{"issue":"6","key":"1870_CR8","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1007\/s11548-013-0842-6","volume":"8","author":"TR McRackan","year":"2013","unstructured":"McRackan TR, Balachandran R, Blachon GS, Mitchell JE, Noble JH, Wright CG, Fitzpatrick JM, Dawant BM, Labadie RF (2013) Validation of minimally invasive, image-guided cochlear implantation using advanced bionics, cochlear, and medel electrodes in a cadaver model. Int J Comput Assist Radiol Surg 8(6):989\u2013995","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1870_CR9","doi-asserted-by":"crossref","first-page":"375","DOI":"10.1016\/j.infrared.2016.03.011","volume":"76","author":"Q Lin","year":"2016","unstructured":"Lin Q, Yang R, Cai K, Si X, Chen X, Wu X (2016) Real-time automatic registration in optical surgical navigation. Infrared Phys Technol 76:375\u2013385","journal-title":"Infrared Phys Technol"},{"key":"1870_CR10","unstructured":"Zhang Y, Shen X, Hu Y (2017) Face registration and surgical instrument tracking for image-guided surgical navigation. In: International conference on virtual reality and visualization. IEEE, pp 65\u201371"},{"issue":"4","key":"1870_CR11","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.1109\/TBME.2014.2301191","volume":"61","author":"J Wang","year":"2014","unstructured":"Wang J, Suenaga H, Hoshi K, Yang L, Kobayashi E, Sakuma I, Liao H (2014) Augmented reality navigation with automatic marker-free image registration using 3-D image overlay for dental surgery. IEEE Trans Biomed Eng 61(4):1295\u20131304","journal-title":"IEEE Trans Biomed Eng"},{"issue":"3","key":"1870_CR12","doi-asserted-by":"crossref","first-page":"259","DOI":"10.1016\/j.zemedi.2016.03.007","volume":"26","author":"M Schwerter","year":"2016","unstructured":"Schwerter M, Lietzmann F, Schad LR (2016) A novel approach for a 2D\/3D image registration routine for medical tool navigation in minimally invasive vascular interventions. Z Med Phys 26(3):259\u2013269","journal-title":"Z Med Phys"},{"issue":"4","key":"1870_CR13","doi-asserted-by":"crossref","first-page":"944","DOI":"10.1007\/s00464-009-0568-2","volume":"24","author":"J Hong","year":"2010","unstructured":"Hong J, Hashizume M (2010) An effective point-based registration tool for surgical navigation. Surg Endosc 24(4):944\u2013948","journal-title":"Surg Endosc"},{"issue":"10","key":"1870_CR14","doi-asserted-by":"crossref","first-page":"2005","DOI":"10.1016\/j.joms.2015.03.017","volume":"73","author":"ZS Peacock","year":"2015","unstructured":"Peacock ZS, Magill JC, Tricomi BJ, Murphy BA, Nikonovskiy V, Hata N, Chauvin L, Troulis MJ (2015) Assessment of the osteomark-navigation system for oral and maxillofacial surgery. J Oral Maxillofac Surg 73(10):2005\u20132016","journal-title":"J Oral Maxillofac Surg"},{"issue":"6","key":"1870_CR15","doi-asserted-by":"crossref","first-page":"20280","DOI":"10.1038\/srep20280","volume":"4","author":"X Chen","year":"2016","unstructured":"Chen X, Xu L, Yang Y, Egger J (2016) A semi-automatic computer-aided method for surgical template design. Sci Rep 4(6):20280","journal-title":"Sci Rep"},{"issue":"6","key":"1870_CR16","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1118\/1.595032","volume":"8","author":"GH Glover","year":"1981","unstructured":"Glover GH, Pelc NJ (1981) An algorithm for the reduction of metal clip artifacts in CT reconstructions. Med Phys 8(6):799\u2013807","journal-title":"Med Phys"},{"issue":"2","key":"1870_CR17","doi-asserted-by":"crossref","first-page":"576","DOI":"10.1148\/radiology.164.2.3602406","volume":"164","author":"WA Kalender","year":"1987","unstructured":"Kalender WA, Hebel R, Ebersberger J (1987) Reduction of CT artifacts caused by metallic implants. Radiology 164(2):576\u2013577","journal-title":"Radiology"},{"issue":"5","key":"1870_CR18","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1109\/34.1000236","volume":"24","author":"D Comaniciu","year":"2002","unstructured":"Comaniciu D, Meer P (2002) Mean shift: a robust approach toward feature space analysis. IEEE Trans Pattern Anal Mach Intell 24(5):603\u2013619","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1870_CR19","first-page":"179","volume":"482","author":"C Deng","year":"2015","unstructured":"Deng C, Li S, Bian F, Yang Y (2015) Remote sensing image segmentation based on mean shift algorithm with adaptive bandwidth. Commun Comput Inf Sci 482:179\u2013185","journal-title":"Commun Comput Inf Sci"},{"issue":"4","key":"1870_CR20","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1002\/rcs.215","volume":"4","author":"X Chen","year":"2008","unstructured":"Chen X, Lin Y, Wu Y, Wang C (2008) Real-time motion tracking in image-guided oral implantology. Int J Med Robot 4(4):339\u2013347","journal-title":"Int J Med Robot"},{"issue":"4","key":"1870_CR21","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1364\/JOSAA.4.000629","volume":"4","author":"BKP Horn","year":"1987","unstructured":"Horn BKP (1987) Closed-form solution of absolute orientation using unit quaternions. J Opt Soc Am A 4(4):629\u2013642","journal-title":"J Opt Soc Am A"},{"issue":"9","key":"1870_CR22","doi-asserted-by":"crossref","first-page":"1987","DOI":"10.1016\/j.joms.2017.01.004","volume":"75","author":"I Azarmehr","year":"2017","unstructured":"Azarmehr I, Stokbro K, Bell RB, Thygesen T (2017) Surgical navigation: a systematic review of indications, treatments, and outcomes in oral and maxillofacial surgery. J Oral Maxillofac Surg 75(9):1987\u20132005","journal-title":"J Oral Maxillofac Surg"},{"issue":"4","key":"1870_CR23","first-page":"810","volume":"48","author":"JB West","year":"2001","unstructured":"West JB, Fitzpatrick JM, Toms SA, Maurer CR Jr, Maciunas RJ (2001) Fiducial point placement and the accuracy of point-based, rigid body registration. Neurosurgery 48(4):810\u2013816","journal-title":"Neurosurgery"},{"issue":"3","key":"1870_CR24","doi-asserted-by":"crossref","first-page":"725","DOI":"10.1109\/TMI.2011.2175939","volume":"31","author":"RR Shamir","year":"2012","unstructured":"Shamir RR, Joskowicz L, Shoshan Y (2012) Fiducial optimization for minimal target registration error in image-guided neurosurgery. IEEE Trans Med Imaging 31(3):725\u2013737","journal-title":"IEEE Trans Med Imaging"},{"issue":"9","key":"1870_CR25","doi-asserted-by":"crossref","first-page":"917","DOI":"10.1109\/42.952729","volume":"20","author":"JB West","year":"2001","unstructured":"West JB, Fitzpatrick JM (2001) The distribution of target registration error in rigid-body point-based registration. IEEE Trans Med Imaging 20(9):917\u2013927","journal-title":"IEEE Trans Med Imaging"},{"issue":"6","key":"1870_CR26","doi-asserted-by":"crossref","first-page":"666","DOI":"10.1016\/j.media.2008.03.002","volume":"12","author":"H Cai","year":"2008","unstructured":"Cai H, Xu X, Lu J, Lichtman J, Yung SP, Wong ST (2008) Using nonlinear diffusion and mean shift to detect and connect cross-sections of axons in 3D optical microscopy images. Med Image Anal 12(6):666\u2013675","journal-title":"Med Image Anal"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1870-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1870-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1870-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,2,6]],"date-time":"2020-02-06T10:20:37Z","timestamp":1580984437000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1870-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,10,13]]},"references-count":26,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2019,2]]}},"alternative-id":["1870"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1870-z","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,10,13]]},"assertion":[{"value":"10 January 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 October 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 October 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}