{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,17]],"date-time":"2026-04-17T06:21:21Z","timestamp":1776406881646,"version":"3.51.2"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2018,11,19]],"date-time":"2018-11-19T00:00:00Z","timestamp":1542585600000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"NIH","award":["R01CA172244"],"award-info":[{"award-number":["R01CA172244"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,1]]},"DOI":"10.1007\/s11548-018-1889-1","type":"journal-article","created":{"date-parts":[[2018,11,19]],"date-time":"2018-11-19T03:13:11Z","timestamp":1542597191000},"page":"147-156","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Robotically assisted long bone biopsy under MRI: cadaver study results"],"prefix":"10.1007","volume":"14","author":[{"given":"Sunghwan","family":"Lim","sequence":"first","affiliation":[]},{"given":"Karun","family":"Sharma","sequence":"additional","affiliation":[]},{"given":"Pan","family":"Li","sequence":"additional","affiliation":[]},{"given":"Doru","family":"Petrisor","sequence":"additional","affiliation":[]},{"given":"Stanley","family":"Fricke","sequence":"additional","affiliation":[]},{"given":"Dan","family":"Stoianovici","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9809-4823","authenticated-orcid":false,"given":"Kevin","family":"Cleary","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2018,11,19]]},"reference":[{"key":"1889_CR1","unstructured":"National Cancer Institute. Cancer in Children and Adolescents [Internet]. National Cancer Institute. [cited 2016 Dec 10]. Available from: \n                    https:\/\/www.cancer.gov\/types\/childhood-cancers\/child-adolescent-cancers-fact-sheet"},{"issue":"2","key":"1889_CR2","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1016\/j.jss.2009.05.030","volume":"160","author":"V Vasudevan","year":"2010","unstructured":"Vasudevan V, Cheung MC, Yang R, Zhuge Y, Fischer AC, Koniaris LG et al (2010) Pediatric solid tumors and second\nmalignancies: characteristics and survival outcomes. J Surg Res 160(2):184\u2013189","journal-title":"J Surg Res"},{"issue":"5","key":"1889_CR3","doi-asserted-by":"publisher","first-page":"584","DOI":"10.1302\/0301-620X.94B5.28523","volume":"94","author":"J Dartnell","year":"2012","unstructured":"Dartnell J, Ramachandran M, Katchburian M (2012) Haematogenous acute and subacute paediatric osteomyelitis: a systematic review of the literature. J Bone Joint Surg Br 94(5):584\u2013595","journal-title":"J Bone Joint Surg Br"},{"issue":"1","key":"1889_CR4","doi-asserted-by":"publisher","first-page":"351","DOI":"10.1146\/annurev.bioeng.9.121806.160642","volume":"9","author":"NV Tsekos","year":"2007","unstructured":"Tsekos NV, Khanicheh A, Christoforou E, Mavroidis C (2007) Magnetic resonance-compatible robotic and mechatronics systems for image-guided interventions and rehabilitation: a review study. Annu Rev Biomed Eng 9(1):351\u2013387","journal-title":"Annu Rev Biomed Eng"},{"issue":"3","key":"1889_CR5","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1109\/EMB.2007.910265","volume":"27","author":"R Gassert","year":"2008","unstructured":"Gassert R, Burdet E, Chinzei K (2008) Opportunities and challenges in MR-compatible robotics. Eng Med Biol Mag IEEE 27(3):15\u201322","journal-title":"Eng Med Biol Mag IEEE"},{"issue":"4","key":"1889_CR6","doi-asserted-by":"publisher","first-page":"458","DOI":"10.1002\/rcs.1630","volume":"11","author":"MM Arnolli","year":"2015","unstructured":"Arnolli MM, Hanumara NC, Franken M, Brouwer DM, Broeders IA (2015) An overview of systems for CT-and MRI-guided percutaneous needle placement in the thorax and abdomen. Int J Med Robot 11(4):458\u2013475","journal-title":"Int J Med Robot"},{"key":"1889_CR7","first-page":"19","volume":"Jun","author":"R Monfaredi","year":"2018","unstructured":"Monfaredi R, Cleary K, Sharma KMRI (2018) Robots for needle-based interventions: systems and technology. Ann Biomed Eng Jun:19","journal-title":"Ann Biomed Eng"},{"issue":"4","key":"1889_CR8","doi-asserted-by":"publisher","first-page":"241","DOI":"10.1080\/13645700701520735","volume":"16","author":"D Stoianovici","year":"2007","unstructured":"Stoianovici D, Song D, Petrisor D, Ursu D, Mazilu D, Muntener M, Schar M, Patriciu A (2007) \u201cMRI Stealth\u201d robot for prostate interventions. Minim Invasive Ther Allied Technol MITAT Off J Soc Minim Invasive Ther. 16(4):241\u2013248","journal-title":"Minim Invasive Ther Allied Technol MITAT Off J Soc Minim Invasive Ther."},{"issue":"3","key":"1889_CR9","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1109\/EMB.2007.910274","volume":"27","author":"A Melzer","year":"2008","unstructured":"Melzer A, Gutmann B, Remmele T, Wolf R, Lukoscheck A, Bock M (2008) INNOMOTION for percutaneous image-guided interventions. IEEE Eng Med Biol Mag 27(3):66\u201373","journal-title":"IEEE Eng Med Biol Mag"},{"issue":"3","key":"1889_CR10","doi-asserted-by":"publisher","first-page":"295","DOI":"10.1109\/TMECH.2008.924044","volume":"13","author":"GS Fischer","year":"2008","unstructured":"Fischer GS, Iordachita I, Csoma C, Tokuda J, DiMaio SP, Tempany CM (2008) MRI-compatible pneumatic robot for transperineal prostate needle placement. IEEEASME Trans Mechatron 13(3):295\u2013305","journal-title":"IEEEASME Trans Mechatron"},{"issue":"11","key":"1889_CR11","doi-asserted-by":"publisher","first-page":"3049","DOI":"10.1109\/TBME.2011.2134096","volume":"58","author":"A Krieger","year":"2011","unstructured":"Krieger A, Iordachita II, Guion P, Singh AK, Kaushal A, M\u00e9nard C (2011) An MRI-compatible robotic system with hybrid tracking for MRI-guided prostate intervention. IEEE Trans Biomed Eng 58(11):3049\u20133060","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"1889_CR12","doi-asserted-by":"publisher","first-page":"011007","DOI":"10.1115\/1.2902854","volume":"2","author":"CJ Walsh","year":"2008","unstructured":"Walsh CJ, Shepard J-A, Gupta R, Hanumara NC, Slocum AH (2008) A patient-mounted, telerobotic tool for CT-guided percutaneous interventions. J Med Devices 2(1):011007","journal-title":"J Med Devices"},{"key":"1889_CR13","doi-asserted-by":"crossref","unstructured":"Hungr N, Fouard C, Robert A, Bricault I, Cinquin P Interventional radiology robot for CT and MRI guided percutaneous interventions. In: Fichtinger G, Martel A, Peters T (eds) Medical image computing and computer-assisted intervention\u2014MICCAI 2011 [Internet]. Springer Berlin Heidelberg; 2011 [cited 2014 Feb 28]. p. 137\u201344. (Lecture Notes in Computer Science). Available from: \n                    http:\/\/link.springer.com\/chapter\/10.1007\/978-3-642-23623-5_18","DOI":"10.1007\/978-3-642-23623-5_18"},{"key":"1889_CR14","unstructured":"Song S-E, Tokuda J, Tuncali K, Yamada A, Torabi M, Hata N. Design evaluation of a double ring RCM mechanism for robotic needle guidance in MRI-guided liver interventions. In: 2013 IEEE\/RSJ international conference on intelligent robots and systems (IROS). 2013. p 4078\u20134083"},{"key":"1889_CR15","doi-asserted-by":"crossref","unstructured":"Wu F, Torabi M, Yamada A, Golden A, Fischer GS, Tuncali K (2013) An MRI coil-mounted multi-probe robotic positioner for cryoablation. In: Proc ASME 2013 Int Des Engineering Tech Conf Comput Inf Eng Conf","DOI":"10.1115\/DETC2013-13132"},{"key":"1889_CR16","doi-asserted-by":"crossref","unstructured":"Monfaredi R, Seifabadi R, Iordachita I, Sze R, Safdar N, Sharma K, Cleary K (2014) Design of a body mounted mri-compatible robot for needle guidance in percutaneous procedures such as arthrography. In: Proceedings of the 5th IEEE RAS\/embs international conference on biomedical robotics and biomechatronics (BioRob2014)","DOI":"10.1109\/BIOROB.2014.6913749"},{"key":"1889_CR17","unstructured":"Stoianovici D, Jun C, Lim S, Li P, Petrisor D, Fricke S, Sharma K, Cleary K Multi-imager compatible, MR safe, remote center of motion needle-guide robot. In: IEEE Trans Biomed Eng [Internet]. 2017 [cited 2017 Aug 27]; Available from: \n                    http:\/\/ieeexplore.ieee.org\/abstract\/document\/7911199\/"},{"issue":"1","key":"1889_CR18","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1016\/j.acra.2017.08.008","volume":"25","author":"K Cleary","year":"2018","unstructured":"Cleary K, Lim S, Jun C, Monfaredi R, Sharma K, Fricke ST, Vargas L, Petrisor D, Stoianovici D (2018) Robotically assisted long bone biopsy under MRI imaging: workflow and preclinical study. Acad Radiol 25(1):74\u201381. \n                    https:\/\/doi.org\/10.1016\/j.acra.2017.08.008","journal-title":"Acad Radiol"},{"key":"1889_CR19","doi-asserted-by":"crossref","unstructured":"Stoianovici D, Whitcomb LL, Anderson JH, Taylor RH, Kavoussi LR A modular surgical robotic system for image guided percutaneous procedures. In: International conference on medical image computing and computer-assisted intervention [Internet]. Springer; 1998 [cited 2016 Dec 11]. p. 404\u2013410. Available from: \n                    http:\/\/link.springer.com\/chapter\/10.1007\/BFb0056225","DOI":"10.1007\/BFb0056225"},{"issue":"5","key":"1889_CR20","doi-asserted-by":"publisher","first-page":"927","DOI":"10.1109\/TRA.2003.817072","volume":"19","author":"D Stoianovici","year":"2003","unstructured":"Stoianovici D, Cleary K, Patriciu A, Mazilu D, Stanimir A, Craciunoiu N, Kavoussi LR (2003) AcuBot: a robot for radiological interventions. IEEE Trans Robot Autom 19(5):927\u2013930","journal-title":"IEEE Trans Robot Autom"},{"issue":"1","key":"1889_CR21","doi-asserted-by":"publisher","first-page":"98","DOI":"10.1109\/TMECH.2006.886258","volume":"12","author":"D Stoianovici","year":"2007","unstructured":"Stoianovici D, Patriciu A, Petrisor D, Mazilu D, Kavoussi L (2007) A new type of motor: pneumatic step motor. IEEEASME Trans Mechatron. 12(1):98\u2013106","journal-title":"IEEEASME Trans Mechatron."},{"issue":"4","key":"1889_CR22","doi-asserted-by":"publisher","first-page":"1289","DOI":"10.1109\/TMECH.2013.2279775","volume":"19","author":"D Stoianovici","year":"2014","unstructured":"Stoianovici D, Kim C, Srimathveeravalli G, Sebrecht P, Petrisor D, Coleman J, Solomon SB, Hricak H (2014) MRI-safe robot for endorectal prostate biopsy. IEEEASME Trans Mechatron. 19(4):1289\u20131299","journal-title":"IEEEASME Trans Mechatron."},{"issue":"4","key":"1889_CR23","doi-asserted-by":"publisher","first-page":"1077","DOI":"10.1109\/TBME.2014.2385307","volume":"62","author":"G Li","year":"2015","unstructured":"Li G, Su H, Cole GA, Shang W, Harrington K, Camilo A (2015) Robotic system for MRI-guided stereotactic neurosurgery. IEEE Trans Biomed Eng 62(4):1077","journal-title":"IEEE Trans Biomed Eng"},{"key":"1889_CR24","doi-asserted-by":"crossref","unstructured":"Abdelaziz ME, Groenhuis V, Veltman J, Siepel F, Stramigioli S (2017) Controlling the Stormram 2: An MRI-compatible robotic system for breast biopsy. In: IEEE international conference on robotics and automation (ICRA) 2017. p 1746\u20131753","DOI":"10.1109\/ICRA.2017.7989206"},{"issue":"1","key":"1889_CR25","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1109\/TMECH.2016.2618362","volume":"22","author":"D Stoianovici","year":"2017","unstructured":"Stoianovici D, Kim C, Petrisor D, Jun C, Lim S, Ball MW (2017) MR safe robot, FDA clearance, safety and feasibility of prostate biopsy clinical trial. IEEEASME Trans Mechatron 22(1):115\u2013126","journal-title":"IEEEASME Trans Mechatron"},{"issue":"5","key":"1889_CR26","doi-asserted-by":"publisher","first-page":"W83","DOI":"10.2214\/AJR.15.15067","volume":"206","author":"MG Cohen","year":"2016","unstructured":"Cohen MG, McMahon CJ, Kung JW, Wu JS (2016) Comparison of battery-powered and manual bone biopsy systems for core needle biopsy of sclerotic bone lesions. Am J Roentgenol 206(5):W83\u2013W86","journal-title":"Am J Roentgenol"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-018-1889-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1889-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-018-1889-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2019,12,18]],"date-time":"2019-12-18T06:08:51Z","timestamp":1576649331000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-018-1889-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11,19]]},"references-count":26,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2019,1]]}},"alternative-id":["1889"],"URL":"https:\/\/doi.org\/10.1007\/s11548-018-1889-1","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2018,11,19]]},"assertion":[{"value":"20 June 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 November 2018","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 November 2018","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}}]}}