{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,11]],"date-time":"2026-03-11T05:55:07Z","timestamp":1773208507767,"version":"3.50.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2019,3,11]],"date-time":"2019-03-11T00:00:00Z","timestamp":1552262400000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,12]]},"DOI":"10.1007\/s11548-019-01942-0","type":"journal-article","created":{"date-parts":[[2019,3,11]],"date-time":"2019-03-11T07:18:27Z","timestamp":1552288707000},"page":"2095-2107","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["HoTPiG: a novel graph-based 3-D image feature set and its applications to computer-assisted detection of cerebral aneurysms and lung nodules"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7496-1651","authenticated-orcid":false,"given":"Shouhei","family":"Hanaoka","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yukihiro","family":"Nomura","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tomomi","family":"Takenaga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Masaki","family":"Murata","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takahiro","family":"Nakao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Soichiro","family":"Miki","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Takeharu","family":"Yoshikawa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Naoto","family":"Hayashi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Osamu","family":"Abe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Akinobu","family":"Shimizu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,3,11]]},"reference":[{"issue":"1","key":"1942_CR1","first-page":"112","volume":"2","author":"Y Nomura","year":"2010","unstructured":"Nomura Y, Hayashi N, Masutani Y, Yoshikawa T, Nemoto M, Hanaoka S, Miki S, Maeda E, Ohtomo K (2010) CIRCUS: an MDA platform for clinical image analysis in hospitals. Trans Mass Data Anal Images Signals 2(1):112\u2013127","journal-title":"Trans Mass Data Anal Images Signals"},{"key":"1942_CR2","doi-asserted-by":"crossref","unstructured":"Hentschke CM, Beuing O, Nickl R, T\u00f6nnies KD (2011) Automatic cerebral aneurysm detection in multimodal angiographic images. In: Nuclear science symposium and medical imaging conference (NSS\/MIC). IEEE, pp 3116\u20133120","DOI":"10.1109\/NSSMIC.2011.6152566"},{"issue":"2","key":"1942_CR3","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1016\/j.acra.2007.09.018","volume":"15","author":"Q Li","year":"2008","unstructured":"Li Q, Li F, Doi K (2008) Computerized detection of lung nodules in thin-section CT images by use of selective enhancement filters and an automated rule-based classifier. Acad Radiol 15(2):165\u2013175. \nhttps:\/\/doi.org\/10.1016\/j.acra.2007.09.018","journal-title":"Acad Radiol"},{"issue":"6","key":"1942_CR4","doi-asserted-by":"publisher","first-page":"617","DOI":"10.1016\/j.acra.2004.02.009","volume":"11","author":"H Arimura","year":"2004","unstructured":"Arimura H, Katsuragawa S, Suzuki K, Li F, Shiraishi J, Sone S, Doi K (2004) Computerized scheme for automated detection of lung nodules in low-dose computed tomography images for lung cancer screening. 1. Acad Radiol 11(6):617\u2013629","journal-title":"Acad Radiol"},{"issue":"9","key":"1942_CR5","doi-asserted-by":"publisher","first-page":"091904","DOI":"10.1118\/1.4890775","volume":"41","author":"CM Hentschke","year":"2014","unstructured":"Hentschke CM, Beuing O, Paukisch H, Scherlach C, Skalej M, T\u00f6nnies KD (2014) A system to detect cerebral aneurysms in multimodality angiographic data sets. Med Phys 41(9):091904","journal-title":"Med Phys"},{"issue":"4","key":"1942_CR6","first-page":"12","volume":"4","author":"Y Nomura","year":"2014","unstructured":"Nomura Y, Masutani Y, Miki S, Nemoto M, Hanaoka S, Yoshikawa T, Hayashi N, Ohtomo K (2014) Performance improvement in computerized detection of cerebral aneurysms by retraining classifier using feedback data collected in routine reading environment. J Biomed Graph Comput 4(4):12","journal-title":"J Biomed Graph Comput"},{"issue":"4","key":"1942_CR7","doi-asserted-by":"publisher","first-page":"948","DOI":"10.1002\/jmri.25842","volume":"47","author":"T Nakao","year":"2018","unstructured":"Nakao T, Hanaoka S, Nomura Y, Sato I, Nemoto M, Miki S, Maeda E, Yoshikawa T, Hayashi N, Abe O (2018) Deep neural network-based computer-assisted detection of cerebral aneurysms in MR angiography. J Magn Reson Imaging 47(4):948\u2013953","journal-title":"J Magn Reson Imaging"},{"issue":"3","key":"1942_CR8","doi-asserted-by":"publisher","first-page":"390","DOI":"10.1016\/j.media.2010.02.004","volume":"14","author":"T Messay","year":"2010","unstructured":"Messay T, Hardie RC, Rogers SK (2010) A new computationally efficient CAD system for pulmonary nodule detection in CT imagery. Med Image Anal 14(3):390\u2013406. \nhttps:\/\/doi.org\/10.1016\/j.media.2010.02.004","journal-title":"Med Image Anal"},{"issue":"7","key":"1942_CR9","doi-asserted-by":"publisher","first-page":"1810","DOI":"10.1109\/TBME.2009.2017027","volume":"56","author":"X Ye","year":"2009","unstructured":"Ye X, Lin X, Dehmeshki J, Slabaugh G, Beddoe G (2009) Shape-based computer-aided detection of lung nodules in thoracic CT images. IEEE Trans Biomed Eng 56(7):1810\u20131820. \nhttps:\/\/doi.org\/10.1109\/TBME.2009.2017027","journal-title":"IEEE Trans Biomed Eng"},{"issue":"1","key":"1942_CR10","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1093\/ietisy\/e89-d.1.340","volume":"89","author":"S Kobashi","year":"2006","unstructured":"Kobashi S, Kondo K, Yutaka H (2006) Computer-aided diagnosis of intracranial aneurysms in MRA images with case-based reasoning. IEICE Trans Inf Syst 89(1):340\u2013350","journal-title":"IEICE Trans Inf Syst"},{"key":"1942_CR11","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/978-3-642-35428-1_8","volume-title":"Machine Learning in Medical Imaging","author":"Santiago Suniaga","year":"2012","unstructured":"Suniaga S, Werner R, Kemmling A, Groth M, Fiehler J, Forkert ND (2012) Computer-aided detection of aneurysms in 3D time-of-flight MRA datasets. In: International workshop on machine learning in medical imaging. Springer, Berlin, pp 63\u201369"},{"issue":"1","key":"1942_CR12","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1007\/s10278-009-9254-0","volume":"24","author":"X Yang","year":"2011","unstructured":"Yang X, Blezek DJ, Cheng LT, Ryan WJ, Kallmes DF, Erickson BJ (2011) Computer-aided detection of intracranial aneurysms in MR angiography. J Digit Imaging 24(1):86\u201395","journal-title":"J Digit Imaging"},{"issue":"11","key":"1942_CR13","doi-asserted-by":"publisher","first-page":"1098","DOI":"10.1016\/j.compbiomed.2012.09.002","volume":"42","author":"D Cascio","year":"2012","unstructured":"Cascio D, Magro R, Fauci F, Iacomi M, Raso G (2012) Automatic detection of lung nodules in CT datasets based on stable 3D mass-spring models. Comput Biol Med 42(11):1098\u20131109. \nhttps:\/\/doi.org\/10.1016\/j.compbiomed.2012.09.002","journal-title":"Comput Biol Med"},{"issue":"2","key":"1942_CR14","doi-asserted-by":"publisher","first-page":"193","DOI":"10.1007\/s11548-012-0767-5","volume":"8","author":"A Teramoto","year":"2012","unstructured":"Teramoto A, Fujita H (2012) Fast lung nodule detection in chest CT images using cylindrical nodule-enhancement filter. Int J Comput Assist Radiol Surg 8(2):193\u2013205. \nhttps:\/\/doi.org\/10.1007\/s11548-012-0767-5","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"10","key":"1942_CR15","doi-asserted-by":"publisher","first-page":"5630","DOI":"10.1118\/1.3633941","volume":"38","author":"M Tan","year":"2011","unstructured":"Tan M, Deklerck R, Jansen B, Bister M, Cornelis J (2011) A novel computer-aided lung nodule detection system for CT images. Med Phys 38(10):5630\u20135645. \nhttps:\/\/doi.org\/10.1118\/1.3633941","journal-title":"Med Phys"},{"key":"1942_CR16","doi-asserted-by":"crossref","unstructured":"Uchiyama Y, Ando H, Yokoyama R, Hara T, Fujita H, Iwama T (2005) Computer-aided diagnosis scheme for detection of unruptured intracranial aneurysms in MR angiography. In: 2005 IEEE engineering in medicine and biology 27th annual conference, pp 3031\u20133034","DOI":"10.1109\/IEMBS.2005.1617113"},{"key":"1942_CR17","doi-asserted-by":"publisher","first-page":"103","DOI":"10.1007\/978-3-319-24571-3_13","volume-title":"Lecture Notes in Computer Science","author":"Shouhei Hanaoka","year":"2015","unstructured":"Hanaoka S, Nomura Y, Nemoto M, Miki S, Yoshikawa T, Hayashi N, Ohtomo K, Masutani Y, Shimizu A (2015) HoTPiG: a novel geometrical feature for vessel morphometry and its application to cerebral aneurysm detection. In: Navab N, Hornegger J, Wells MW, Frangi FA (eds) Medical image computing and computer-assisted intervention\u2014MICCAI 2015: 18th international conference, Munich, Germany, October 5\u20139, 2015, proceedings, Part II. Springer, Cham, pp 103\u2013110. \nhttps:\/\/doi.org\/10.1007\/978-3-319-24571-3_13"},{"issue":"3","key":"1942_CR18","first-page":"36","volume":"4","author":"Y Nomura","year":"2014","unstructured":"Nomura Y, Nemoto M, Masutani Y, Hanaoka S, Yoshikawa T, Miki S, Maeda E, Hayashi N, Yoshioka N, Ohtomo K (2014) Reduction of false positives at vessel bifurcations in computerized detection of lung nodules. J Biomed Graph Comput 4(3):36","journal-title":"J Biomed Graph Comput"},{"key":"1942_CR19","unstructured":"Sreekanth V, Vedaldi A, Zisserman A, Jawahar C (2010) Generalized RBF feature maps for efficient detection. In: Proceedings of the British machine vision conference (BMVC), 31 August\u20133 September 2010, Aberystwyth, pp 1\u201311"},{"issue":"6","key":"1942_CR20","doi-asserted-by":"publisher","first-page":"707","DOI":"10.1016\/j.media.2010.05.005","volume":"14","author":"B Ginneken van","year":"2010","unstructured":"van Ginneken B, Armato SG, de Hoop B, van Amelsvoort-van de Vorst S, Duindam T, Niemeijer M, Murphy K, Schilham A, Retico A, Fantacci ME, Camarlinghi N, Bagagli F, Gori I, Hara T, Fujita H, Gargano G, Bellotti R, Tangaro S, Bola\u00f1os L, Carlo FD, Cerello P, Cristian Cheran S, Lopez Torres E, Prokop M (2010) Comparing and combining algorithms for computer-aided detection of pulmonary nodules in computed tomography scans: the ANODE09 study. Med Image Anal 14(6):707\u2013722. \nhttps:\/\/doi.org\/10.1016\/j.media.2010.05.005","journal-title":"Med Image Anal"},{"issue":"Suppl. 1","key":"1942_CR21","first-page":"S132","volume":"10","author":"Y Nomura","year":"2015","unstructured":"Nomura Y, Masutani Y, Kudo S, Nakaguchi T, Hanaoka S, Nemoto M, Miki S, Yoshikawa T, Hayashi N (2015) Preliminary study for training and evaluation of various computerized detection software of cerebral aneurysms in-hospital testbed environment. Int J Comput Assist Radiol Surg 10(Suppl. 1):S132\u2013S133","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"1942_CR22","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1016\/j.media.2017.06.015","volume":"42","author":"AAA Setio","year":"2017","unstructured":"Setio AAA, Traverso A, de Bel T, Berens MSN, Bogaard C, Cerello P, Chen H, Dou Q, Fantacci ME, Geurts B, Gugten R, Heng PA, Jansen B, de Kaste MMJ, Kotov V, Lin JY-H, Manders JTMC, S\u00f3\u00f1ora-Mengana A, Garc\u00eda-Naranjo JC, Papavasileiou E, Prokop M, Saletta M, Schaefer-Prokop CM, Scholten ET, Scholten L, Snoeren MM, Torres EL, Vandemeulebroucke J, Walasek N, Zuidhof GCA, Ginneken B, Jacobs C (2017) Validation, comparison, and combination of algorithms for automatic detection of pulmonary nodules in computed tomography images: the LUNA16 challenge. Med Image Anal 42:1\u201313. \nhttps:\/\/doi.org\/10.1016\/j.media.2017.06.015","journal-title":"Med Image Anal"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-01942-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-019-01942-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-01942-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,3,10]],"date-time":"2020-03-10T00:10:50Z","timestamp":1583799050000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-019-01942-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,3,11]]},"references-count":22,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2019,12]]}},"alternative-id":["1942"],"URL":"https:\/\/doi.org\/10.1007\/s11548-019-01942-0","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,3,11]]},"assertion":[{"value":"15 August 2018","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 March 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 March 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"All authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1975 Helsinki declaration, as revised in 2008(5). For this type of study, formal consent is not required.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical standards"}}]}}