{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T20:08:33Z","timestamp":1790712513072,"version":"4.1.0"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2019,5,22]],"date-time":"2019-05-22T00:00:00Z","timestamp":1558483200000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,5,22]],"date-time":"2019-05-22T00:00:00Z","timestamp":1558483200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,8]]},"DOI":"10.1007\/s11548-019-01996-0","type":"journal-article","created":{"date-parts":[[2019,5,23]],"date-time":"2019-05-23T03:40:59Z","timestamp":1558582859000},"page":"1353-1364","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":12,"title":["Automatic detection of intracranial aneurysm using LBP and Fourier descriptor in angiographic images"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9086-5080","authenticated-orcid":false,"given":"Ines","family":"Rahmany","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mohamed El Arbi","family":"Nemmala","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Nawres","family":"Khlifa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Houda","family":"Megdiche","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2019,5,22]]},"reference":[{"key":"1996_CR1","doi-asserted-by":"publisher","first-page":"103110","DOI":"10.1016\/S0140-6736(03)13860-3","volume":"362","author":"D Wiebers","year":"2003","unstructured":"Wiebers D (2003) The international study of unruptured intracranial aneurysms investigators, unruptured intracranial aneurysms: natural history, clinical outcome, and risks of surgical and endovascular treatment. Lancet 362:103110","journal-title":"Lancet"},{"key":"1996_CR2","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1016\/j.wneu.2016.12.053","volume":"99","author":"T Abboud","year":"2015","unstructured":"Abboud T, Rustom J, Bester M, Czorlich P, Vittorazzi E, Pinnschmidt HO (2015) Morphology of ruptured and unruptured intracranial aneurysms. World Neurosurg 99:610\u2013617","journal-title":"World Neurosurg"},{"key":"1996_CR3","doi-asserted-by":"publisher","first-page":"994","DOI":"10.1161\/STROKEAHA.108.191395","volume":"40","author":"JB Bederson","year":"2009","unstructured":"Bederson JB, Connolly ESJ, Batjer HH (2009) Guidelines for the management of aneurysmal subarachnoid hemorrhage: a statement for healthcare professionals from a special writing group of the Stroke Council, American Heart Association. Stroke 40:994\u20131025","journal-title":"Stroke"},{"issue":"7","key":"1996_CR4","first-page":"11871198","volume":"23","author":"JP Villablanca","year":"2002","unstructured":"Villablanca JP, Jahan R, Hooshi P, Lim S, Duckwiler G, Patel A, Sayre J, Martin N, Frazee J, Bentson J, Viuela F (2002) Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography. Am J Neuroradiol 23(7):11871198","journal-title":"Am J Neuroradiol"},{"key":"1996_CR5","doi-asserted-by":"publisher","first-page":"336","DOI":"10.1227\/01.NEU.0000103448.07132.E1","volume":"54","author":"M Kangasniemi","year":"2004","unstructured":"Kangasniemi M, Makela T, Koskinen S, Porras M, Hernesniemi KPJ (2004) Detection of intracranial aneurysms with two-dimensional and three-dimensional multislice helical computed tomographic angiography. Neurosurgery 54:336\u2013341","journal-title":"Neurosurgery"},{"issue":"5","key":"1996_CR6","doi-asserted-by":"publisher","first-page":"2439","DOI":"10.1118\/1.3575417","volume":"38","author":"I Larrabide","year":"2011","unstructured":"Larrabide I, Villa-Uriol MC, Cardenes R, Maria J (2011) Three-dimensional morphological analysis of intracranial aneurysms: a fully automated method for aneurysm sac isolation and quantication. Med Phys 38(5):2439\u20132449","journal-title":"Med Phys"},{"key":"1996_CR7","unstructured":"Jerman T, Pernu F, Likar B, Spiclin Z (2015) Computer-aided detection and quantication of intracranial aneurysms. Lecture Notes in Computer Science; 9350; MICCAI, International Conference on Medical Image Computing and Computer-Assisted Intervention 18:3-10"},{"key":"1996_CR8","first-page":"10931104","volume":"11","author":"H Arimura","year":"2004","unstructured":"Arimura H, Li Q, Korogi Y, Hirai T, Abe H, Yamashita Y, Katsuragawa S, Ikeda R, Doi K (2004) Automated computerized scheme for detection of unruptured intracranial aneurysms in three-dimensional magnetic resonance angiography. Acad Radiol 11:10931104","journal-title":"Acad Radiol"},{"key":"1996_CR9","doi-asserted-by":"crossref","unstructured":"Uchiyama Y, Ando H, Hara T, Fujita H, Iwama T (2005) Computer-aided diagnosis scheme for detection of unruptured intracranial aneurysms in MR angiography. In: Proceedings of the 2005 IEEE engineering in medicine and biology 27th annual conference Shanghai, China, September 1\u20134, 30313034","DOI":"10.1109\/IEMBS.2005.1617113"},{"issue":"1","key":"1996_CR10","first-page":"2531","volume":"6","author":"K Okamoto","year":"2000","unstructured":"Okamoto K, Ito J, Sakai K, Yoshimura S (2000) The principle of digital subtraction angiography and radiological protection. Interv Neuroradiol 6(1):2531","journal-title":"Interv Neuroradiol"},{"issue":"1","key":"1996_CR11","doi-asserted-by":"publisher","first-page":"5159","DOI":"10.1016\/0031-3203(95)00067-4","volume":"29","author":"T Ojala","year":"1996","unstructured":"Ojala T, Pietikinen M, Harwood D (1996) A comparative study of texture measures with classification based on feature distributions. Pattern Recognit 29(1):5159","journal-title":"Pattern Recognit"},{"issue":"3","key":"1996_CR12","doi-asserted-by":"publisher","first-page":"9775","DOI":"10.4249\/scholarpedia.9775","volume":"5","author":"M Pietikinen","year":"2010","unstructured":"Pietikinen M (2010) Local binary patterns. Scholarpedia 5(3):9775","journal-title":"Scholarpedia"},{"key":"1996_CR13","doi-asserted-by":"publisher","first-page":"117125","DOI":"10.1016\/j.artmed.2010.02.006","volume":"49","author":"L Nanni","year":"2010","unstructured":"Nanni L, Lumini A, Brahnam S (2010) Local binary patterns variants as texture descriptors for medical image analysis. Artif Intell Med 49:117125","journal-title":"Artif Intell Med"},{"issue":"2","key":"1996_CR14","doi-asserted-by":"publisher","first-page":"24","DOI":"10.3390\/jimaging5020024","volume":"5","author":"M George","year":"2019","unstructured":"George M, Zwiggelaar R (2019) Comparative study on local binary patterns for mammographic density and risk scoring. J Imaging 5(2):24\u201343","journal-title":"J Imaging"},{"issue":"6","key":"1996_CR15","first-page":"286293","volume":"41","author":"AA Oliver","year":"2011","unstructured":"Oliver AA, Llado X, Freixenet J, Marti J (2011) False positive reduction in mammographic mass detection using local binary patterns. IEEE Trans Syst Man Cybern Appl Rev 41(6):286293","journal-title":"IEEE Trans Syst Man Cybern Appl Rev"},{"issue":"14","key":"1996_CR16","doi-asserted-by":"publisher","first-page":"29172936","DOI":"10.1080\/01431160500057723","volume":"26","author":"A Lucieer","year":"2005","unstructured":"Lucieer A, Stein A, Fisher P (2005) Multivariate texture-based segmentation of remotely sensed imagery for extraction of objects and their uncertainty. Int J Remote Sens 26(14):29172936","journal-title":"Int J Remote Sens"},{"key":"1996_CR17","doi-asserted-by":"crossref","unstructured":"Ali W, Georgsson F, Hellstrom T (2008) Visual tree detection for autonomous navigation in forest environment. In: Proceedings of the IEEE intelligence in vehicle symposium, 560565","DOI":"10.1109\/IVS.2008.4621315"},{"issue":"7","key":"1996_CR18","doi-asserted-by":"publisher","first-page":"971987","DOI":"10.1109\/TPAMI.2002.1017623","volume":"24","author":"T Ojala","year":"2002","unstructured":"Ojala T, Pietikinen M, Menp T (2002) Multiresolution gray-scale and rotation invariant texture classification with local binary patterns. IEEE Trans Pattern Anal Mach Intell 24(7):971987","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"1996_CR19","doi-asserted-by":"publisher","first-page":"21","DOI":"10.1109\/TIT.1967.1053964","volume":"13","author":"T Cover","year":"1967","unstructured":"Cover T, Hart P (1967) Nearest-neighbor pattern classification. IEEE Trans Inf Theory 13:21\u201327","journal-title":"IEEE Trans Inf Theory"},{"issue":"2","key":"1996_CR20","doi-asserted-by":"publisher","first-page":"305","DOI":"10.1007\/s00357-007-0015-9","volume":"24","author":"RO Duda","year":"2007","unstructured":"Duda RO, Hart PE, Stork DG (2007) Pattern classification. J Classif 24(2):305\u2013307","journal-title":"J Classif"},{"key":"1996_CR21","unstructured":"Yang M, Kpalma K, Ronsin J (2008) A survey of shape feature extraction techniques. In: Yin PY (ed) Pattern recognition. IN-TECH, pp 43\u201390"},{"issue":"1","key":"1996_CR22","doi-asserted-by":"publisher","first-page":"57","DOI":"10.5565\/rev\/elcvia.529","volume":"12","author":"J Mitra","year":"2000","unstructured":"Mitra J, Chandra A, Haldar T (2000) Peak trekking of hierarchy mountain for the detection of cerebral aneurysm using modified hough circle transform. Electron Lett Comput Vis Image Anal 12(1):57\u201384","journal-title":"Electron Lett Comput Vis Image Anal"},{"issue":"9","key":"1996_CR23","doi-asserted-by":"publisher","first-page":"3127","DOI":"10.1161\/STROKEAHA.109.553800","volume":"40","author":"M Li","year":"2009","unstructured":"Li M (2009) Large-cohort comparison between three-dimensional time-of-flight magnetic resonance and rotational digital subtraction angiographies in intracranial aneurysm detection. Stroke 40(9):3127\u20133129","journal-title":"Stroke"},{"issue":"1","key":"1996_CR24","first-page":"57","volume":"12","author":"S Mondal","year":"2014","unstructured":"Mondal S, Chandra A (2014) One novel algorithm for the detection of Cerebral Aneurysm using morphological filtering. Electron Lett Comput Vis Image Anal 12(1):57\u201384","journal-title":"Electron Lett Comput Vis Image Anal"},{"key":"1996_CR25","doi-asserted-by":"crossref","unstructured":"Momeni S, Pourghassem H (2015) An automatic aneurysm extraction algorithm in fused brain digital subtraction angiography images. In: International conference on communications and signal processing (ICCSP)","DOI":"10.1016\/j.bbe.2015.06.003"},{"issue":"4","key":"1996_CR26","doi-asserted-by":"publisher","first-page":"445","DOI":"10.1515\/bmt-2016-0168","volume":"63","author":"I Rahmany","year":"2018","unstructured":"Rahmany I, Khlifa N (2018) A priori knowledge integration for the detection of cerebral aneurysm. Biomed Eng\/Biomedizinische Technik, BMT 63(4):445\u2013452","journal-title":"Biomed Eng\/Biomedizinische Technik, BMT"},{"issue":"5","key":"1996_CR27","doi-asserted-by":"publisher","first-page":"771","DOI":"10.2174\/1573405613666170502162130","volume":"14","author":"I Rahmany","year":"2018","unstructured":"Rahmany I, Laajili S, Khlifa N (2018) Automated computerized method for detection of unruptured cerebral aneurysms in DSA images. Curr Med Imaging Rev CMIR 14(5):771\u2013777","journal-title":"Curr Med Imaging Rev CMIR"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-01996-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-019-01996-0\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-01996-0.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,20]],"date-time":"2020-05-20T23:26:48Z","timestamp":1590017208000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-019-01996-0"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,22]]},"references-count":27,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019,8]]}},"alternative-id":["1996"],"URL":"https:\/\/doi.org\/10.1007\/s11548-019-01996-0","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,22]]},"assertion":[{"value":"9 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"13 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 May 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}