{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,12]],"date-time":"2025-08-12T22:22:57Z","timestamp":1755037377386,"version":"3.37.3"},"reference-count":32,"publisher":"Springer Science and Business Media LLC","issue":"8","license":[{"start":{"date-parts":[[2019,6,5]],"date-time":"2019-06-05T00:00:00Z","timestamp":1559692800000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2019,6,5]],"date-time":"2019-06-05T00:00:00Z","timestamp":1559692800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13GW0019C","13GW0019E"],"award-info":[{"award-number":["13GW0019C","13GW0019E"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,8]]},"DOI":"10.1007\/s11548-019-02002-3","type":"journal-article","created":{"date-parts":[[2019,6,5]],"date-time":"2019-06-05T13:02:34Z","timestamp":1559739754000},"page":"1389-1401","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Workflow assessment as a preclinical development tool"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-6352-6486","authenticated-orcid":false,"given":"Samuel","family":"M\u00fcller","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"L\u00fcder A.","family":"Kahrs","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Johannes","family":"Gaa","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sebastian","family":"Tauscher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Marcel","family":"Kluge","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Samuel","family":"John","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas S.","family":"Rau","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Lenarz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Tobias","family":"Ortmaier","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Omid","family":"Majdani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2019,6,5]]},"reference":[{"key":"2002_CR1","unstructured":"National Institues of Health (2010) Cochlear implants \n                    https:\/\/report.nih.gov\/NIHfactsheets\/ Pdfs\/CochlearImplants(NIDCD).pdf\n                    \n                  . Accessed 12 Dec 2017 [Online]"},{"key":"2002_CR2","unstructured":"World Health Organization, WHO (2017) Deafness and hearing loss \n                    http:\/\/www.who.int\/mediacentre\/factsheets\/fs300\/en\/\n                    \n                  . Accessed 12 Dec 2017 [Online]"},{"key":"2002_CR3","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1016\/j.otohns.2009.11.029","volume":"142","author":"R Balachandran","year":"2010","unstructured":"Balachandran R, Mitchell JE, Blachon G, Noble JH, Dawant BM, Fitzpatrick JM, Labadie RF (2010) Percutaneous cochlear implant drilling via customized frames: an in vitro study. Otolaryngol Head Neck Surg 142:421\u2013426","journal-title":"Otolaryngol Head Neck Surg"},{"key":"2002_CR4","doi-asserted-by":"crossref","unstructured":"Kobler JP, Kotlarski J, Lexow GJ, Rau TS, Majdani O, Ortmaier T (2014) Design optimization of a bone-attached, redundant and reconfigurable parallel kinematic device for skull surgery. In: IEEE international conference on robotics and automation (ICRA), pp 2364\u20132371","DOI":"10.1109\/ICRA.2014.6907187"},{"key":"2002_CR5","doi-asserted-by":"publisher","first-page":"137","DOI":"10.1007\/s11548-011-0619-8","volume":"7","author":"JP Kobler","year":"2011","unstructured":"Kobler JP, Kotlarski J, \u00d6ltjen J, Baron S, Ortmaier T (2011) Design and analysis of a head-mounted parallel kinematic device for skull surgery. Int J Comput Assist Radiol Surg 7:137\u2013149","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR6","doi-asserted-by":"publisher","first-page":"421","DOI":"10.1007\/s11548-015-1300-4","volume":"11","author":"JP Kobler","year":"2016","unstructured":"Kobler JP, N\u00fclle K, Lexow GJ, Rau TS, Majdani O, Kahrs LA, Kotlarski J, Tobias Ortmaier (2016) Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery. Int J Comput Assist Radiol Surg 11:421\u2013436","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR7","first-page":"94","volume":"31","author":"LB Kratchman","year":"2010","unstructured":"Kratchman LB, Blachon GS, Withrow TJ, Balachandran R, Labadie RF, Webster RJ (2010) Toward automation of image-guided microstereotactic frames: a bone-attached parallel robot for percutaneous cochlear implantation. Robot Sci Syst Workshop Enabling Technol 31:94\u201399","journal-title":"Robot Sci Syst Workshop Enabling Technol"},{"key":"2002_CR8","doi-asserted-by":"publisher","first-page":"2904","DOI":"10.1109\/TBME.2011.2162512","volume":"58","author":"LB Kratchman","year":"2011","unstructured":"Kratchman LB, Blachon GS, Withrow TJ, Balachandran R, Labadie RF, Webster RJ (2011) Design of a bone-attached parallel robot for percutaneous cochlear implantation. IEEE Trans Biomed Eng 58:2904\u20132910","journal-title":"IEEE Trans Biomed Eng"},{"key":"2002_CR9","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1097\/MAO.0b013e3181c2f81a","volume":"31","author":"RF Labadie","year":"2010","unstructured":"Labadie RF, Balachandran R, Mitchel JE, Noble JH, Majdani O, Haynes DS (2010) Clinical validation study of percutaneous cochlear access using patient customized micro-stereotactic frames. Otol Neurotol 31:94\u201399","journal-title":"Otol Neurotol"},{"key":"2002_CR10","first-page":"1915","volume":"124","author":"RF Labadie","year":"2014","unstructured":"Labadie RF, Balachandran R, Noble JH, Blachon GS, Mitchell JE, Reda FA, Dawant BM, Fitzpatrick JM (2014) Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation the laryngoscope. Am Laryngol Rhinol Otol Soc 124:1915\u20131922","journal-title":"Am Laryngol Rhinol Otol Soc"},{"key":"2002_CR11","unstructured":"Vollmann B, M\u00fcller S, Kundrat D, Ortmaier T, Kahrs LA (2015) Methods for intraoperative, sterile pose-setting of patient-specific microstereotactic frames. In: Proceedings of SPIE, vol 9415, pp 94150M\u201394157"},{"key":"2002_CR12","unstructured":"Rau TS, Lexow GJ, Blume D, Kluge M, Lenarz T, Majdani O (2017) Micro-stereotactic frame utilizing bone cement for individual fabrication: an initial investigation of its accuracy. In: Proc SPIE, vol 10135, p 10135\u201310139"},{"key":"2002_CR13","doi-asserted-by":"publisher","first-page":"11","DOI":"10.1179\/1467010014Z.000000000192","volume":"15","author":"B Bell","year":"2014","unstructured":"Bell B, Williamson T, Gerber N, Gavaghan K, Wimmer W, Kompis M, Weber S, Caversaccio M (2014) An image-guided robot system for direct cochlear access. Cochlear Implants Int 15:11\u201313","journal-title":"Cochlear Implants Int"},{"key":"2002_CR14","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s11548-009-0360-8","volume":"4","author":"O Majdani","year":"2009","unstructured":"Majdani O, Rau TS, Baron S, Eilers H, Baier C, Heimann B, Ortmaier T, Bartling S, Lenarz T, Leinung M (2009) A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study. Int J Comput Assist Radiol Surg 4:475\u2013486","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR15","doi-asserted-by":"publisher","first-page":"1763","DOI":"10.1007\/s11548-017-1638-x","volume":"12","author":"S Tauscher","year":"2017","unstructured":"Tauscher S, Fuchs A, Baier F, Kahrs LA, Ortmaier T (2017) High-accuracy drilling with an image guided light weight robot: autonomous versus intuitive feed control. Int J Comput Assist Radiol Surg 12:1763\u20131773","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"eaal491","key":"2002_CR16","first-page":"6","volume":"2","author":"S Weber","year":"2017","unstructured":"Weber S, Gavaghan K, Wimmer W, Williamson T, Gerber N, Anso J, Bell B, Feldmann A, Rathgeb C, Matulic M, Stebinger M, Schneider D, Mantokoudis G, Scheidegger O, Wagner F, Kompis M, Caversaccio M (2017) Instrument flight to the inner ear. Sci Robot 2(eaal491):6","journal-title":"Sci Robot"},{"key":"2002_CR17","doi-asserted-by":"publisher","first-page":"1241","DOI":"10.4028\/www.scientific.net\/AMM.577.1241","volume":"577","author":"Y Zhu","year":"2014","unstructured":"Zhu Y, Xu Y, Ke J, Ma F, Hu L, Li C (2014) Research on computer-assisted minimally invasive cochlear implant system. Appl Mech Mater 577:1241\u20131244","journal-title":"Appl Mech Mater"},{"key":"2002_CR18","doi-asserted-by":"crossref","unstructured":"Dahroug B, Tamadazte B, Tavernier L, Weber S, Andreff N (2018) Review on otological robotic systems: toward micro-robot assisted cholesteatoma surgery. In: IEEE reviews in biomedical engineering, early access, ahead of print","DOI":"10.1109\/RBME.2018.2810605"},{"key":"2002_CR19","unstructured":"Ans\u00f3 J, Wimmer W, Rathgeb C, Gerber N, Schneider D, Hermann J, Williamson T, Mantokoudis G, Caversaccio M, Weber S, Gavaghan K (2017) Robotic cochlear implantation\u2014first clinical experiences. In: Proceedings of 16th annual meeting of the German society for computer and robot assisted surgery, CURAC 2017, pp 144\u2013150"},{"key":"2002_CR20","doi-asserted-by":"publisher","first-page":"2","DOI":"10.1016\/j.amjsurg.2004.08.025","volume":"188","author":"DB Camarillo","year":"2004","unstructured":"Camarillo DB, Krummel TM, Kenneth SJ (2004) Robotic technology in surgery: past, present, and future. Am J Surg 188:2\u201315","journal-title":"Am J Surg"},{"key":"2002_CR21","doi-asserted-by":"publisher","first-page":"701","DOI":"10.1056\/NEJMp1006602","volume":"363","author":"GI Barbash","year":"2010","unstructured":"Barbash GI, Glied SA (2010) New technology and health care costs\u2014the case of robot-assisted surgery. N Engl J Med 363:701\u2013704","journal-title":"N Engl J Med"},{"key":"2002_CR22","doi-asserted-by":"publisher","first-page":"31","DOI":"10.1115\/1.4030083","volume":"9","author":"NP Dillon","year":"2015","unstructured":"Dillon NP, Balachandran R, Fitzpatrick JM, Siebold MA, Labadie RF, Wanna GB, Withrow TJ, Webster RJ (2015) A compact bone-attached robot for mastoidectomy. J Med Device 9:31\u201337","journal-title":"J Med Device"},{"key":"2002_CR23","doi-asserted-by":"publisher","first-page":"845","DOI":"10.1007\/s11548-013-0973-9","volume":"9","author":"B Cho","year":"2014","unstructured":"Cho B, Matsumoto N, Mori M, Komune S, Hashizume M (2014) Image-guided placement of the Bonebridge without surgical navigation equipment. Int J Comput Assist Radiol Surg 9:845\u2013855","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR24","first-page":"123","volume":"2","author":"T Neumuth","year":"2016","unstructured":"Neumuth T (2016) Surgical process modeling. Innov Surg Sci 2:123\u2013137","journal-title":"Innov Surg Sci"},{"key":"2002_CR25","doi-asserted-by":"publisher","first-page":"495","DOI":"10.1007\/s11548-013-0940-5","volume":"9","author":"F Lalys","year":"2014","unstructured":"Lalys F, Jannin P (2014) Surgical process modeling: a review. Int J Comput Assist Radiol Surg 9:495\u2013511","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR26","doi-asserted-by":"publisher","first-page":"121","DOI":"10.1080\/136457001753192222","volume":"10","author":"L MacKenzie","year":"2001","unstructured":"MacKenzie L, Ibbotson JA, Cao CGL, Lomax AJ (2001) Hierarchical decomposition of laparoscopic surgery: a human factors approach to investigating the operating room environment. Minim Invasive Therapy Allied Technol 10:121\u2013127","journal-title":"Minim Invasive Therapy Allied Technol"},{"issue":"3","key":"2002_CR27","doi-asserted-by":"publisher","first-page":"147","DOI":"10.1016\/j.artmed.2010.12.003","volume":"51","author":"D Neumuth","year":"2011","unstructured":"Neumuth D, Loebe F, Herre H, Neumuth T (2011) Modeling surgical processes: a four-level translational approach. Artif Intell Med 51(3):147\u2013161","journal-title":"Artif Intell Med"},{"key":"2002_CR28","first-page":"438","volume":"1","author":"T Neumuth","year":"2006","unstructured":"Neumuth T, Schumann S, Strau\u00df G, Jannin P, Meixensberger J, Dietz A, Lemke HU, Burgert O (2006) Visualization options for surgical workflows. Int J Comput Assist Radiol Surg 1:438\u2013440","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR29","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.medengphy.2015.02.012","volume":"37","author":"JP Kobler","year":"2015","unstructured":"Kobler JP, Prielozny L, Lexow GJ, Rau TS, Majdani O, Ortmaier T (2015) Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery. Med Eng Phys 37:460\u2013468","journal-title":"Med Eng Phys"},{"key":"2002_CR30","doi-asserted-by":"publisher","first-page":"1625","DOI":"10.1007\/s11548-015-1153-x","volume":"10","author":"JP Kobler","year":"2015","unstructured":"Kobler JP, Wall S, Lexow GJ, Lang CP, Majdani O, Kahrs LA, Ortmaier T (2015) An experimental evaluation of loads occurring during guided drilling for cochlear implantation. Int J Comput Assist Radiol Surg 10:1625\u20131637","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2002_CR31","unstructured":"Schneider V, Mueller S, Nuelle K, Kahrs LA, Majdani O, Ortmaier T (2017) Experimental accuracy optimization of a parallel kinematic tool for minimally invasive cochlear-implant surgery. In: Proceedings of 16th annual meeting of the German society for computer and robot assisted surgery, CURAC 2017, pp 202\u2013207"},{"key":"2002_CR32","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1007\/s11548-013-0936-1","volume":"9","author":"JP Kobler","year":"2014","unstructured":"Kobler JP, Beckmann Dl, Rau TS, Majdani O, Ortmaier T (2014) An automated insertion tool for cochlear implants with integrated force sensing capability. Int J Comput Assist Radiol Surg 9:481\u2013494","journal-title":"Int J Comput Assist Radiol Surg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-02002-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-019-02002-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-02002-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,6,3]],"date-time":"2020-06-03T23:10:36Z","timestamp":1591225836000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-019-02002-3"}},"subtitle":["Surgical process models of three techniques for minimally invasive cochlear implantation"],"short-title":[],"issued":{"date-parts":[[2019,6,5]]},"references-count":32,"journal-issue":{"issue":"8","published-print":{"date-parts":[[2019,8]]}},"alternative-id":["2002"],"URL":"https:\/\/doi.org\/10.1007\/s11548-019-02002-3","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2019,6,5]]},"assertion":[{"value":"9 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 June 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors Tobias Ortmaier, Marcel Kluge, Samuel John, Thomas Rau, Omid Majdani and Thomas Lenarz declare being limited partners of H\u00f6rSys IP GmbH & Co. KG that holds intellectual property regarding the RoboJig<sup>TM<\/sup> technology.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical statement"}},{"value":"This articles does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}