{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T06:22:11Z","timestamp":1778826131230,"version":"3.51.4"},"reference-count":39,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T00:00:00Z","timestamp":1559174400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T00:00:00Z","timestamp":1559174400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["SCHL 1844\/2-1"],"award-info":[{"award-number":["SCHL 1844\/2-1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["SCHL 1844\/2-2"],"award-info":[{"award-number":["SCHL 1844\/2-2"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2019,9]]},"DOI":"10.1007\/s11548-019-02006-z","type":"journal-article","created":{"date-parts":[[2019,5,30]],"date-time":"2019-05-30T18:01:26Z","timestamp":1559239286000},"page":"1485-1493","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":17,"title":["Spatio-temporal deep learning models for tip force estimation during needle insertion"],"prefix":"10.1007","volume":"14","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6325-5092","authenticated-orcid":false,"given":"Nils","family":"Gessert","sequence":"first","affiliation":[]},{"given":"Torben","family":"Priegnitz","sequence":"additional","affiliation":[]},{"given":"Thore","family":"Saathoff","sequence":"additional","affiliation":[]},{"given":"Sven-Thomas","family":"Antoni","sequence":"additional","affiliation":[]},{"given":"David","family":"Meyer","sequence":"additional","affiliation":[]},{"given":"Moritz Franz","family":"Hamann","sequence":"additional","affiliation":[]},{"given":"Klaus-Peter","family":"J\u00fcnemann","sequence":"additional","affiliation":[]},{"given":"Christoph","family":"Otte","sequence":"additional","affiliation":[]},{"given":"Alexander","family":"Schlaefer","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2019,5,30]]},"reference":[{"issue":"4","key":"2006_CR1","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.medengphy.2006.07.003","volume":"29","author":"N Abolhassani","year":"2007","unstructured":"Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29(4):413\u2013431","journal-title":"Med Eng Phys"},{"key":"2006_CR2","doi-asserted-by":"publisher","first-page":"1657","DOI":"10.1007\/978-3-319-32552-1_63","volume-title":"Springer Handbook of Robotics","author":"Russell H. Taylor","year":"2016","unstructured":"Taylor RH, Menciassi A, Fichtinger G, Fiorini P, Dario P (2016) Medical robotics and computer-integrated surgery. In: Siciliano B, Khatib O (eds) Springer handbook of robotics. Springer Handbooks. Springer, Cham"},{"issue":"10","key":"2006_CR3","doi-asserted-by":"publisher","first-page":"1707","DOI":"10.1109\/TBME.2004.831542","volume":"51","author":"AM Okamura","year":"2004","unstructured":"Okamura AM, Simone C, O\u2019leary MD (2004) Force modeling for needle insertion into soft tissue. IEEE Trans Biomed Eng 51(10):1707\u20131716","journal-title":"IEEE Trans Biomed Eng"},{"key":"2006_CR4","doi-asserted-by":"crossref","unstructured":"Kataoka H, Washio T, Chinzei K, Mizuhara K, Simone C, Okamura AM (2002) Measurement of the tip and friction force acting on a needle during penetration. In: International conference on medical image computing and computer-assisted intervention, pp 216\u2013223","DOI":"10.1007\/3-540-45786-0_27"},{"issue":"13","key":"2006_CR5","doi-asserted-by":"publisher","first-page":"1766","DOI":"10.1002\/bjs.9669","volume":"101","author":"S Rodrigues","year":"2014","unstructured":"Rodrigues S, Horeman T, Sam P, Dankelman J, van den Dobbelsteen J, Jansen FW (2014) Influence of visual force feedback on tissue handling in minimally invasive surgery. British J Surg 101(13):1766\u20131773","journal-title":"British J Surg"},{"issue":"1","key":"2006_CR6","first-page":"109","volume":"62","author":"C Hatzfeld","year":"2017","unstructured":"Hatzfeld C, Wismath S, Hessinger M, Werthsch\u00fctzky R, Schlaefer A, Kupnik M (2017) A miniaturized sensor for needle tip force measurements. Biomed Eng 62(1):109\u2013115","journal-title":"Biomed Eng"},{"issue":"1","key":"2006_CR7","doi-asserted-by":"publisher","first-page":"38","DOI":"10.3390\/s17010038","volume":"17","author":"S Beekmans","year":"2016","unstructured":"Beekmans S, Lembrechts T, van den Dobbelsteen J, van Gerwen D (2016) Fiber-optic Fabry\u2013P\u00e9rot interferometers for axial force sensing on the tip of a needle. Sensors 17(1):38","journal-title":"Sensors"},{"key":"2006_CR8","first-page":"131","volume":"4","author":"H Su","year":"2011","unstructured":"Su H, Zervas M, Furlong C, Fischer GS (2011) A miniature mri-compatible fiber-optic force sensor utilizing Fabry\u2013Perot interferometer. MEMS Nanotechnol 4:131\u2013136","journal-title":"MEMS Nanotechnol"},{"issue":"4","key":"2006_CR9","doi-asserted-by":"publisher","first-page":"355","DOI":"10.1088\/0957-0233\/8\/4\/002","volume":"8","author":"YJ Rao","year":"1997","unstructured":"Rao YJ (1997) In-fibre bragg grating sensors. Meas Sci Technol 8(4):355","journal-title":"Meas Sci Technol"},{"issue":"6","key":"2006_CR10","doi-asserted-by":"publisher","first-page":"1251","DOI":"10.1016\/j.jbiomech.2014.01.054","volume":"47","author":"P Roriz","year":"2014","unstructured":"Roriz P, Carvalho L, Fraz\u00e3o O, Santos JL, Sim\u00f5es JA (2014) From conventional sensors to fibre optic sensors for strain and force measurements in biomechanics applications: a review. J Biomechan 47(6):1251\u20131261","journal-title":"J Biomechan"},{"issue":"12","key":"2006_CR11","doi-asserted-by":"publisher","first-page":"127,009","DOI":"10.1117\/1.JBO.21.12.127009","volume":"21","author":"S Kumar","year":"2016","unstructured":"Kumar S, Shrikanth V, Amrutur B, Asokan S, Bobji MS (2016) Detecting stages of needle penetration into tissues through force estimation at needle tip using fiber bragg grating sensors. J Biomed Opt 21(12):127,009","journal-title":"J Biomed Opt"},{"issue":"15","key":"2006_CR12","first-page":"538","volume":"5","author":"KM Kennedy","year":"2015","unstructured":"Kennedy KM, Chin L, McLaughlin RA, Latham B, Saunders CM, Sampson DD, Kennedy BF (2015) Quantitative micro-elastography: imaging of tissue elasticity using compression optical coherence elastography. Sci Rep 5(15):538","journal-title":"Sci Rep"},{"issue":"2","key":"2006_CR13","doi-asserted-by":"publisher","first-page":"1172","DOI":"10.1364\/BOE.8.001172","volume":"8","author":"KV Larin","year":"2017","unstructured":"Larin KV, Sampson DD (2017) Optical coherence elastography-oct at work in tissue biomechanics. Biomed Opt Express 8(2):1172\u20131202","journal-title":"Biomed Opt Express"},{"key":"2006_CR14","doi-asserted-by":"crossref","unstructured":"Otte C, Beringhoff J, Latus S, Antoni ST, Rajput O, Schlaefer A (2016) Towards force sensing based on instrument-tissue interaction. In: IEEE international conference on multisensor fusion and integration for intelligent systems, pp 180\u2013185","DOI":"10.1109\/MFI.2016.7849486"},{"issue":"7","key":"2006_CR15","doi-asserted-by":"publisher","first-page":"1073","DOI":"10.1007\/s11548-018-1777-8","volume":"13","author":"N Gessert","year":"2018","unstructured":"Gessert N, Beringhoff J, Otte C, Schlaefer A (2018) Force estimation from oct volumes using 3d cnns. Int J Comput Assist Radiol Surg 13(7):1073\u20131082","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"12","key":"2006_CR16","doi-asserted-by":"publisher","first-page":"2310","DOI":"10.1364\/OL.37.002310","volume":"37","author":"KM Kennedy","year":"2012","unstructured":"Kennedy KM, Kennedy BF, McLaughlin RA, Sampson DD (2012) Needle optical coherence elastography for tissue boundary detection. Opt Lett 37(12):2310\u20132312","journal-title":"Opt Lett"},{"issue":"4","key":"2006_CR17","doi-asserted-by":"publisher","first-page":"245","DOI":"10.3414\/ME13-01-0135","volume":"53","author":"C Otte","year":"2014","unstructured":"Otte C, Otte S, Wittig L, H\u00fcttmann G, Kugler C, Dr\u00f6mann D, Zell A, Schlaefer A (2014) Investigating recurrent neural networks for OCT A-scan based tissue analysis. Methods Inf Med 53(4):245\u2013249","journal-title":"Methods Inf Med"},{"issue":"3","key":"2006_CR18","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1109\/TOH.2016.2640289","volume":"10","author":"AI Aviles","year":"2017","unstructured":"Aviles AI, Alsaleh SM, Hahn JK, Casals A (2017) Towards retrieving force feedback in robotic-assisted surgery: a supervised neuro-recurrent-vision approach. IEEE Trans Haptics 10(3):431\u2013443","journal-title":"IEEE Trans Haptics"},{"key":"2006_CR19","unstructured":"Simonyan K, Zisserman A (2014) Two-stream convolutional networks for action recognition in videos. In: Advances in neural information processing systems, pp 568\u2013576"},{"key":"2006_CR20","doi-asserted-by":"crossref","unstructured":"Wang L, Qiao Y, Tang X (2015) Action recognition with trajectory-pooled deep-convolutional descriptors. In: CVPR, pp 4305\u20134314","DOI":"10.1109\/CVPR.2015.7299059"},{"key":"2006_CR21","unstructured":"Yue-Hei\u00a0Ng J, Hausknecht M, Vijayanarasimhan S, Vinyals O, Monga R, Toderici G (2015) Beyond short snippets: deep networks for video classification. In: CVPR, pp 4694\u20134702"},{"key":"2006_CR22","doi-asserted-by":"crossref","unstructured":"Long X, Gan C, de\u00a0Melo G, Wu J, Liu X, Wen S (2018) Attention clusters: Purely attention based local feature integration for video classification. In: CVPR","DOI":"10.1109\/CVPR.2018.00817"},{"issue":"1","key":"2006_CR23","doi-asserted-by":"publisher","first-page":"221","DOI":"10.1109\/TPAMI.2012.59","volume":"35","author":"S Ji","year":"2013","unstructured":"Ji S, Xu W, Yang M, Yu K (2013) 3D convolutional neural networks for human action recognition. IEEE Trans Pattern Anal Mach Intell 35(1):221\u2013231","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"2006_CR24","doi-asserted-by":"crossref","unstructured":"Tran D, Bourdev L, Fergus R, Torresani L, Paluri M (2015) Learning spatiotemporal features with 3D convolutional networks. In: ICCV, pp 4489\u20134497","DOI":"10.1109\/ICCV.2015.510"},{"key":"2006_CR25","doi-asserted-by":"crossref","unstructured":"Donahue J, Anne\u00a0Hendricks L, Guadarrama S, Rohrbach M, Venugopalan S, Saenko K, Darrell T (2015) Long-term recurrent convolutional networks for visual recognition and description. In: CVPR, pp 2625\u20132634","DOI":"10.1109\/CVPR.2015.7298878"},{"key":"2006_CR26","unstructured":"Xingjian S, Chen Z, Wang H, Yeung DY, Wong WK, Woo Wc (2015) Convolutional LSTM network: A machine learning approach for precipitation nowcasting. In: Advances in Neural Information Processing Systems, pp 802\u2013810"},{"key":"2006_CR27","doi-asserted-by":"crossref","unstructured":"Gessert N, Priegnitz T, Saathoff T, Antoni ST, Meyer D, Hamann MF, J\u00fcnemann KP, Otte C, Schlaefer A (2018) Needle tip force estimation using an oct fiber and a fused convgru-cnn architecture. In: International conference on medical image computing and computer-assisted intervention, pp 222\u2013229","DOI":"10.1007\/978-3-030-00937-3_26"},{"key":"2006_CR28","unstructured":"Cooijmans T, Ballas N, Laurent C, G\u00fcl\u00e7ehre \u00c7, Courville A (2017) Recurrent batch normalization. In: ICLR"},{"key":"2006_CR29","doi-asserted-by":"crossref","unstructured":"Pham V, Bluche T, Kermorvant C, Louradour J (2014) Dropout improves recurrent neural networks for handwriting recognition. In: International conference on frontiers in handwriting recognition, pp 285\u2013290","DOI":"10.1109\/ICFHR.2014.55"},{"key":"2006_CR30","doi-asserted-by":"crossref","unstructured":"He K, Zhang X, Ren S, Sun J (2016) Deep residual learning for image recognition. In: CVPR, pp 770\u2013778","DOI":"10.1109\/CVPR.2016.90"},{"key":"2006_CR31","doi-asserted-by":"crossref","unstructured":"Cho K, Van\u00a0Merri\u00ebnboer B, Gulcehre C, Bahdanau D, Bougares F, Schwenk H, Bengio Y (2014) Learning phrase representations using rnn encoder-decoder for statistical machine translation. In: EMNLP, pp 1724\u20131734","DOI":"10.3115\/v1\/D14-1179"},{"key":"2006_CR32","doi-asserted-by":"publisher","first-page":"63","DOI":"10.1007\/978-3-540-28650-9_4","volume-title":"Advanced Lectures on Machine Learning","author":"Carl Edward Rasmussen","year":"2004","unstructured":"Rasmussen CE (2004) Gaussian processes in machine learning. In: Advanced lectures on machine learning, pp 63\u201371"},{"key":"2006_CR33","first-page":"265","volume":"16","author":"M Abadi","year":"2016","unstructured":"Abadi M, Barham P, Chen J, Chen Z, Davis A, Dean J, Devin M, Ghemawat S, Irving G, Isard M et al (2016) Tensorflow: a system for large-scale machine learning. OSDI 16:265\u2013283","journal-title":"OSDI"},{"issue":"3","key":"2006_CR34","doi-asserted-by":"publisher","first-page":"037,501","DOI":"10.1117\/1.JMI.2.3.037501","volume":"2","author":"BG Muller","year":"2015","unstructured":"Muller BG, de Bruin DM, Van den Bos W, Brandt MJ, Velu JF, Bus MT, Faber DJ, Heijink CDS, Zondervan PJ, de Reijke TM et al (2015) Prostate cancer diagnosis: the feasibility of needle-based optical coherence tomography. J Med Imaging 2(3):037,501","journal-title":"J Med Imaging"},{"key":"2006_CR35","unstructured":"Ballas N, Yao L, Pal C, Courville A (2016) Delving deeper into convolutional networks for learning video representations. In: ICLR"},{"issue":"1","key":"2006_CR36","doi-asserted-by":"publisher","first-page":"151","DOI":"10.1016\/j.jtcvs.2004.05.029","volume":"129","author":"M Kitagawa","year":"2005","unstructured":"Kitagawa M, Dokko D, Okamura AM, Yuh DD (2005) Effect of sensory substitution on suture-manipulation forces for robotic surgical systems. J Thorac Cardiovasc Surg 129(1):151\u2013158","journal-title":"J Thorac Cardiovasc Surg"},{"issue":"4","key":"2006_CR37","doi-asserted-by":"publisher","first-page":"e1809","DOI":"10.1002\/rcs.1809","volume":"13","author":"L Meli","year":"2017","unstructured":"Meli L, Pacchierotti C, Prattichizzo D (2017) Experimental evaluation of magnified haptic feedback for robot-assisted needle insertion and palpation. Int J Med Robot Comput Assist Surg 13(4):e1809","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"3","key":"2006_CR38","first-page":"16:1","volume":"15","author":"AI Aviles-Rivero","year":"2018","unstructured":"Aviles-Rivero AI, Alsaleh SM, Philbeck J, Raventos SP, Younes N, Hahn JK, Casals A (2018) Sensory substitution for force feedback recovery: a perception experimental study. ACM Trans Appl Percept (TAP) 15(3):16:1\u201316:19","journal-title":"ACM Trans Appl Percept (TAP)"},{"issue":"2","key":"2006_CR39","doi-asserted-by":"publisher","first-page":"522","DOI":"10.1109\/TBME.2013.2283501","volume":"61","author":"X He","year":"2014","unstructured":"He X, Handa J, Gehlbach P, Taylor R, Iordachita I (2014) A submillimetric 3-DOF force sensing instrument with integrated fiber Bragg grating for retinal microsurgery. IEEE Trans Biomed Eng 61(2):522\u2013534","journal-title":"IEEE Trans Biomed Eng"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-02006-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-019-02006-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-019-02006-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2020,5,28]],"date-time":"2020-05-28T19:12:31Z","timestamp":1590693151000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-019-02006-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,5,30]]},"references-count":39,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2019,9]]}},"alternative-id":["2006"],"URL":"https:\/\/doi.org\/10.1007\/s11548-019-02006-z","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2019,5,30]]},"assertion":[{"value":"25 January 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 May 2019","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 May 2019","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}