{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,27]],"date-time":"2026-03-27T16:25:15Z","timestamp":1774628715796,"version":"3.50.1"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"5","license":[{"start":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T00:00:00Z","timestamp":1587340800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T00:00:00Z","timestamp":1587340800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Canadian Foundation for Innovation","award":["20994"],"award-info":[{"award-number":["20994"]}]},{"DOI":"10.13039\/501100000024","name":"Canadian Institutes of Health Research","doi-asserted-by":"publisher","award":["201409"],"award-info":[{"award-number":["201409"]}],"id":[{"id":"10.13039\/501100000024","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000038","name":"Natural Sciences and Engineering Research Council of Canada","doi-asserted-by":"publisher","award":["2014 04504"],"award-info":[{"award-number":["2014 04504"]}],"id":[{"id":"10.13039\/501100000038","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,5]]},"DOI":"10.1007\/s11548-020-02142-x","type":"journal-article","created":{"date-parts":[[2020,4,20]],"date-time":"2020-04-20T21:02:31Z","timestamp":1587416551000},"page":"749-757","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":16,"title":["Augmented reality simulator for ultrasound-guided percutaneous renal access"],"prefix":"10.1007","volume":"15","author":[{"given":"Yanyu","family":"Mu","sequence":"first","affiliation":[]},{"given":"David","family":"Hocking","sequence":"additional","affiliation":[]},{"given":"Zhan Tao","family":"Wang","sequence":"additional","affiliation":[]},{"given":"Gregory J.","family":"Garvin","sequence":"additional","affiliation":[]},{"given":"Roy","family":"Eagleson","sequence":"additional","affiliation":[]},{"given":"Terry M.","family":"Peters","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,4,20]]},"reference":[{"issue":"1","key":"2142_CR1","doi-asserted-by":"publisher","first-page":"15","DOI":"10.1016\/j.juro.2007.03.014","volume":"178","author":"NL Miller","year":"2007","unstructured":"Miller NL, Matlaga BR, Lingeman JE (2007) Techniques for fluoroscopic percutaneous renal access. J Urol 178(1):15\u201323","journal-title":"J Urol"},{"issue":"1","key":"2142_CR2","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1016\/j.eururo.2004.08.009","volume":"47","author":"A Skolarikos","year":"2005","unstructured":"Skolarikos A, Alivizatos G, de la Rosette JJMCH (2005) Percutaneous nephrolithotomy and its legacy. Eur Urol 47(1):22\u201328","journal-title":"Eur Urol"},{"key":"2142_CR3","unstructured":"Darren B, Hassan R, Naeem B, Jennifer B, David BB, David TT, Marshall LS, Thomas C (2019) Techniques\u2014ultrasound\u2014guided percutaneous nephrolithotomy: how we do it. Can Urol Assoc J 14(3)"},{"issue":"1","key":"2142_CR4","doi-asserted-by":"publisher","first-page":"54","DOI":"10.1016\/j.aju.2013.08.002","volume":"12","author":"CF Ng","year":"2014","unstructured":"Ng CF (2014) Training in percutaneous nephrolithotomy: the learning curve and options. Arab J Urol 12(1):54\u201357","journal-title":"Arab J Urol"},{"issue":"2","key":"2142_CR5","doi-asserted-by":"publisher","first-page":"592","DOI":"10.1097\/01.ju.0000104849.25168.6d","volume":"171","author":"CL Lee","year":"2004","unstructured":"Lee CL, Anderson JK, Monga M (2004) Residency training in percutaneous renal access: does it affect urological practice? J Urol 171(2):592\u2013595","journal-title":"J Urol"},{"issue":"1","key":"2142_CR6","doi-asserted-by":"publisher","first-page":"47","DOI":"10.1055\/s-0033-1333661","volume":"26","author":"H Samia","year":"2013","unstructured":"Samia H, Khan S, Lawrence J, Delaney CP (2013) Simulation and its role in training. Clin Colon Rectal Surg 26(1):47\u201355","journal-title":"Clin Colon Rectal Surg"},{"issue":"S1","key":"2142_CR7","doi-asserted-by":"publisher","first-page":"S10","DOI":"10.1089\/end.2016.0587","volume":"31","author":"YA Noureldin","year":"2016","unstructured":"Noureldin YA, Andonian S (2016) Simulation for percutaneous renal access: where are we? J Endourol 31(S1):S10\u2013S19","journal-title":"J Endourol"},{"key":"2142_CR8","doi-asserted-by":"publisher","first-page":"635","DOI":"10.1089\/end.2009.0166","volume":"24","author":"S Mishra","year":"2010","unstructured":"Mishra S, Kurien A, Patel R, Patil P, Ganpule A, Muthu V, Ravindra B, Desai M (2010) Validation of virtual reality simulation for percutaneous renal access training. J Endourol Endourol Soc 24:635\u201340","journal-title":"J Endourol Endourol Soc"},{"issue":"10","key":"2142_CR9","doi-asserted-by":"publisher","first-page":"779","DOI":"10.4103\/0301-4738.171508","volume":"63","author":"P Singh","year":"2015","unstructured":"Singh P, Sarkar L, Sethi HS, Gupta VS (2015) A randomized controlled prospective study to assess the role of subconjunctival bevacizumab in primary pterygium surgery in indian patients. Indian J Ophthalmol 63(10):779\u2013784","journal-title":"Indian J Ophthalmol"},{"issue":"23","key":"2142_CR10","doi-asserted-by":"publisher","first-page":"453","DOI":"10.21037\/atm.2016.12.24","volume":"4","author":"Ido Badash","year":"2016","unstructured":"Badash I, Burtt K, Solorzano CA, Carey JN (2016) Innovations in surgery simulation: a review of past, current and future techniques. In: Annals of translational medicine (focus on: innovations and technology in surgery\u2019), vol 4, no 23","journal-title":"Annals of Translational Medicine"},{"issue":"4","key":"2142_CR11","doi-asserted-by":"publisher","first-page":"292","DOI":"10.1080\/2090598X.2019.1642600","volume":"17","author":"M Vijayakumar","year":"2019","unstructured":"Vijayakumar M, Balaji S, Singh A, Ganpule A, Sabnis R, Desai M (2019) A novel biological model for training in percutaneous renal access. Arab J Urol 17(4):292\u2013297. https:\/\/doi.org\/10.1080\/2090598X.2019.1642600","journal-title":"Arab J Urol"},{"issue":"2","key":"2142_CR12","doi-asserted-by":"publisher","first-page":"240","DOI":"10.1089\/end.2014.0401","volume":"29","author":"D Veneziano","year":"2014","unstructured":"Veneziano D, Smith A, Reihsen T, Speich J, Sweet RM (2014) The simportal fluoro-less c-arm trainer: an innovative device for percutaneous kidney access. J Endourol 29(2):240\u2013245","journal-title":"J Endourol"},{"issue":"4","key":"2142_CR13","doi-asserted-by":"publisher","first-page":"155014771984017","DOI":"10.1177\/1550147719840173","volume":"15","author":"Y Tai","year":"2019","unstructured":"Tai Y, Wei L, Zhou H, Peng J, Li Q, Li F, Zhang J, Shi J (2019) Augmented-reality-driven medical simulation platform for percutaneous nephrolithotomy with cybersecurity awareness. Int J Distrib Sens Netw 15(4):1550147719840173","journal-title":"Int J Distrib Sens Netw"},{"issue":"7","key":"2142_CR14","doi-asserted-by":"publisher","first-page":"1149","DOI":"10.1007\/s00345-018-2219-5","volume":"36","author":"YA Noureldin","year":"2018","unstructured":"Noureldin YA, Hoenig DM, Zhao P, Elsamra SE, Stern J, Gaunay G, Motamedinia P, Okeke Z, Rastinehad AR, Sweet RM (2018) Incorporation of the fluoroless c-arm trainer at the american urological association hands on training percutaneous renal access. World J Urol 36(7):1149\u20131155","journal-title":"World J Urol"},{"issue":"5","key":"2142_CR15","doi-asserted-by":"publisher","first-page":"346","DOI":"10.4111\/icu.2017.58.5.346","volume":"58","author":"FC Ng","year":"2017","unstructured":"Ng FC, Yam WL, Lim TYB, Teo JK, Ng KK, Lim SK (2017) Ultrasound-guided percutaneous nephrolithotomy: advantages and limitations. Invest Clin Urol 58(5):346\u2013352","journal-title":"Invest Clin Urol"},{"issue":"7","key":"2142_CR16","doi-asserted-by":"publisher","first-page":"1065","DOI":"10.1007\/s11548-014-1120-y","volume":"10","author":"A Pacioni","year":"2015","unstructured":"Pacioni A, Carbone M, Freschi C, Viglialoro R, Ferrari V, Ferrari M (2015) Patient-specific ultrasound liver phantom: materials and fabrication method. Int J Comput Assist Radiol Surg 10(7):1065\u20131075","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"6","key":"2142_CR17","doi-asserted-by":"publisher","first-page":"1043","DOI":"10.1007\/s11548-013-0901-z","volume":"8","author":"L Bartha","year":"2013","unstructured":"Bartha L, Lasso A, Pinter C, Ungi T, Keri Z, Fichtinger G (2013) Open-source surface mesh-based ultrasound-guided spinal intervention simulator. Int J Comput Assist Radiol Surg 8(6):1043\u20131051","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"10","key":"2142_CR18","doi-asserted-by":"publisher","first-page":"4174","DOI":"10.1007\/s00464-016-4800-6","volume":"30","author":"EZ Barsom","year":"2016","unstructured":"Barsom EZ, Graafland M, Schijven MP (2016) Systematic review on the effectiveness of augmented reality applications in medical training. Surg Endosc 30(10):4174\u201383","journal-title":"Surg Endosc"},{"issue":"10","key":"2142_CR19","doi-asserted-by":"publisher","first-page":"1525","DOI":"10.1007\/s00464-003-0035-4","volume":"17","author":"AG Gallagher","year":"2003","unstructured":"Gallagher AG, Ritter EM, Satava RM (2003) Fundamental principles of validation, and reliability: rigorous science for the assessment of surgical education and training. Surg Endosc 17(10):1525\u20131529","journal-title":"Surg Endosc"},{"issue":"4\/5","key":"2142_CR20","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1080\/13645700500221881","volume":"14","author":"MP Schijven","year":"2005","unstructured":"Schijven MP, Jakimowicz JJ (2005) Validation of virtual reality simulators: key to the successful integration of a novel teaching technology into minimal access surgery. Minim Invas Ther Allied Technol 14(4\/5):244\u2013246","journal-title":"Minim Invas Ther Allied Technol"},{"key":"2142_CR21","doi-asserted-by":"publisher","first-page":"125976","DOI":"10.1109\/ACCESS.2019.2939229","volume":"7","author":"W Xia","year":"2019","unstructured":"Xia W, Chen ECS, Pautler SE, Peters TM (2019) A global optimization method for specular highlight removal from a single image. IEEE Access 7:125976\u2013125990","journal-title":"IEEE Access"},{"issue":"6","key":"2142_CR22","first-page":"243","volume":"9","author":"O Gerovich","year":"2004","unstructured":"Gerovich O, Marayong P, Okamura AM (2004) The effect of visual and haptic feedback on computer-assisted needle insertion. Comput Aided Surg 9(6):243\u2013249","journal-title":"Comput Aided Surg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02142-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02142-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02142-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,4,19]],"date-time":"2021-04-19T23:25:41Z","timestamp":1618874741000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02142-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,4,20]]},"references-count":22,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2020,5]]}},"alternative-id":["2142"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02142-x","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,4,20]]},"assertion":[{"value":"14 November 2019","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 March 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 April 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study. This article does not contain patient data beyond the anonymized retrospective imaging data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}