{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,8,30]],"date-time":"2025-08-30T17:17:55Z","timestamp":1756574275427,"version":"3.37.3"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2020,6,8]],"date-time":"2020-06-08T00:00:00Z","timestamp":1591574400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,6,8]],"date-time":"2020-06-08T00:00:00Z","timestamp":1591574400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["JP17H01252"],"award-info":[{"award-number":["JP17H01252"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,9]]},"DOI":"10.1007\/s11548-020-02207-x","type":"journal-article","created":{"date-parts":[[2020,6,8]],"date-time":"2020-06-08T14:05:12Z","timestamp":1591625112000},"page":"1537-1547","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Softness sensing probe with multiple acoustic paths for laparoscopic surgery"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-6506-0125","authenticated-orcid":false,"given":"Taku","family":"Ukai","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7917-1379","authenticated-orcid":false,"given":"Yoshihiro","family":"Tanaka","sequence":"additional","affiliation":[]},{"given":"Tomohiro","family":"Fukuda","sequence":"additional","affiliation":[]},{"given":"Takuma","family":"Kajikawa","sequence":"additional","affiliation":[]},{"given":"Hiroshi","family":"Miura","sequence":"additional","affiliation":[]},{"given":"Yukihiro","family":"Terada","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,6,8]]},"reference":[{"issue":"3","key":"2207_CR1","doi-asserted-by":"publisher","first-page":"512","DOI":"10.3844\/ajassp.2009.512.517","volume":"6","author":"B Darvish","year":"2009","unstructured":"Darvish B, Najarian S, Shirzad E, Khodambashi R (2009) A novel tactile force probe for tissue stiffness classification. Am J Appl Sci 6(3):512\u2013517","journal-title":"Am J Appl Sci"},{"key":"2207_CR2","unstructured":"Li J, Liu H, Althoefer K, Seneviratne L (2012) A stiffness probe based on force and vision sensing for soft tissue diagnosis. In: Proceeding of annual international conference of the IEEE engineering in medicine and biology society. pp 944\u2013947"},{"issue":"15","key":"2207_CR3","doi-asserted-by":"publisher","first-page":"5889","DOI":"10.1109\/JSEN.2016.2574322","volume":"16","author":"T Watanabe","year":"2016","unstructured":"Watanabe T, Iwai T, Koyama T, Yoneyama T (2016) Stiffness measurement system using endoscopes with a visualization method. IEEE Sens J 16(15):5889\u20135897","journal-title":"IEEE Sens J"},{"key":"2207_CR4","doi-asserted-by":"crossref","unstructured":"Wanninayake I, Seneviratne L, Althoefer K (2012) Novel indentation depth measuring system for stiffness characterization in soft tissue palpation. In: Proceeding of IEEE international conference on robotics and automation. pp 4648\u20134653","DOI":"10.1109\/ICRA.2012.6225127"},{"issue":"2\u20133","key":"2207_CR5","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.sna.2004.01.038","volume":"112","author":"S Omata","year":"2004","unstructured":"Omata S, Murayama Y, Constantinou CE (2004) Real time robotic tactile sensor system for the determination of the physical properties of biomaterials. Sens Actuators, A 112(2\u20133):278\u2013285","journal-title":"Sens Actuators, A"},{"key":"2207_CR6","unstructured":"Peng Q, Omata S, Peehl D M, Constantinou C E (2011) Stiffness mapping prostate biopsy samples using a tactile sensor. In: Proceeding of annual international conference of the IEEE engineering in medicine and biology society. pp 8515\u20138518"},{"issue":"4","key":"2207_CR7","doi-asserted-by":"publisher","first-page":"5774","DOI":"10.4238\/2013.November.22.4","volume":"12","author":"Y Zhao","year":"2013","unstructured":"Zhao Y, Zhang TB, Bao CH, Chen XY, Wang Y, Wang Q (2013) Physical properties of gastrointestinal stromal tumors based on atomic force microscope analysis. Genet Mol Res 12(4):5774\u20135785","journal-title":"Genet Mol Res"},{"issue":"1","key":"2207_CR8","doi-asserted-by":"publisher","first-page":"46","DOI":"10.2174\/157340512799220562","volume":"8","author":"DV Litwiller","year":"2012","unstructured":"Litwiller DV, Mariappan YK, Ehman RL (2012) Magnetic resonance elastography. Curr Med Imaging Rev 8(1):46\u201355","journal-title":"Curr Med Imaging Rev"},{"issue":"1","key":"2207_CR9","doi-asserted-by":"publisher","first-page":"88","DOI":"10.1152\/jn.1995.73.1.88","volume":"73","author":"MA Srinivasan","year":"1995","unstructured":"Srinivasan MA, Lamotte RH (1995) Tactual discrimination of softness. J Neurophysiol 73(1):88\u2013105","journal-title":"J Neurophysiol"},{"key":"2207_CR10","doi-asserted-by":"crossref","unstructured":"Peng P, Sezen A, Rajamani R, Erdman A (2009) Novel MEMS stiffness sensor for in vivo tissue characterization measurement. In: Proceeding of annual international conference of the IEEE engineering in medicine and biology society. pp 6640\u20136643","DOI":"10.1109\/IEMBS.2009.5332865"},{"issue":"4","key":"2207_CR11","doi-asserted-by":"publisher","first-page":"989","DOI":"10.1088\/0964-1726\/16\/4\/006","volume":"16","author":"S Sokhanvar","year":"2007","unstructured":"Sokhanvar S, Packirisamy M, Dargahi J (2007) A multifunctional PVDF-based tactile sensor for minimally invasive surgery. Smart Mater Struct 16(4):989","journal-title":"Smart Mater Struct"},{"issue":"4","key":"2207_CR12","doi-asserted-by":"publisher","first-page":"431","DOI":"10.1002\/rcs.413","volume":"7","author":"M Kalantari","year":"2011","unstructured":"Kalantari M, Ramezanifard M, Ahmadi R, Dargahi J, Kovecses JA (2011) Piezoresistive tactile sensor for tissue characterization during catheter-based cardiac surgery. Int J Med Robot Comput Assist Surg 7(4):431\u2013440","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"12","key":"2207_CR13","doi-asserted-by":"publisher","first-page":"1679","DOI":"10.1109\/JSEN.2009.2025586","volume":"9","author":"S Sokhanvar","year":"2009","unstructured":"Sokhanvar S, Packirisamy M, Dargahi J (2009) MEMS endoscopic tactile sensor: toward in- situ and in-vivo tissue softness characterization. IEEE Sens J 9(12):1679\u20131687","journal-title":"IEEE Sens J"},{"issue":"5","key":"2207_CR14","doi-asserted-by":"publisher","first-page":"548","DOI":"10.1109\/JSEN.2009.2016620","volume":"9","author":"H Leng","year":"2009","unstructured":"Leng H, Lin Y (2009) Development of a novel deformation-based tissue softness sensor. IEEE Sens J 9(5):548\u2013554","journal-title":"IEEE Sens J"},{"key":"2207_CR15","doi-asserted-by":"crossref","unstructured":"Tanii R, Nguyen T, Takahata T, Shimoyama I (2018) Elasticity sensor using different tactile properties on one chip. In: Proceedings of IEEE international conference on micro electro mechanical systems. pp 862\u2013865","DOI":"10.1109\/MEMSYS.2018.8346692"},{"key":"2207_CR16","doi-asserted-by":"crossref","unstructured":"Faragasso A, Bimbo J, Yamashita A, Asama H (2018) Disposable stiffness sensor for endoscopic examination. In: Proceeding of annual international conference of the IEEE engineering in medicine and biology society. pp 4309\u20134312","DOI":"10.1109\/EMBC.2018.8513350"},{"key":"2207_CR17","doi-asserted-by":"crossref","unstructured":"Faragasso A, Stilli A, Bimbo J, Wurdemann H, Althoefer K (2015) Multi-axis stiffness sensing device for medical palpation. In: Proceeding of IEEE\/RSJ international conference on intelligent robots and systems. pp 2711\u20132716","DOI":"10.1109\/IROS.2015.7353748"},{"issue":"2","key":"2207_CR18","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s11548-014-1067-z","volume":"10","author":"Y Tanaka","year":"2015","unstructured":"Tanaka Y, Fukuda T, Fujiwara M, Sano A (2015) Tactile sensor using acoustic reflection for lump detection in laparoscopic surgery. Int J Comput Assist Radiol Surg 10(2):183\u2013193","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2207_CR19","doi-asserted-by":"crossref","unstructured":"Takayama Y, Tanaka Y, Fukuda T, Miura H, Terada Y (2019) Soft wearable tactile sensor for softness evaluation through internal examination. In: Proceeding of IEEE international conference on systems, man and cybernetics. pp 3210\u20133215","DOI":"10.1109\/SMC.2019.8914425"},{"key":"2207_CR20","doi-asserted-by":"crossref","unstructured":"Fujii Y, Okamoto S, Yamada Y (2014) Interactive forces caused by scanning wavy surfaces. In: Proceeding of IEEE haptics symposium. pp 449\u2013453","DOI":"10.1109\/HAPTICS.2014.6775497"},{"key":"2207_CR21","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.triboint.2012.11.024","volume":"65","author":"J Van Kuilenburg","year":"2012","unstructured":"Van Kuilenburg J, Masen M, van der Heide E (2012) The role of the skin microrelief in the contact behaviour of human skin contact between the human finger and regular surface textures. Tribol Int 65:81\u201390","journal-title":"Tribol Int"},{"issue":"1","key":"2207_CR22","doi-asserted-by":"publisher","first-page":"81","DOI":"10.1016\/j.triboint.2004.11.003","volume":"39","author":"C Pailler-Mattei","year":"2006","unstructured":"Pailler-Mattei C, Zahouani H (2006) Analysis of adhesive behaviour of human skin in vivo by an indentation test. Tribol Int 39(1):81\u201390","journal-title":"Tribol Int"},{"issue":"3","key":"2207_CR23","doi-asserted-by":"publisher","first-page":"875","DOI":"10.1016\/j.juro.2012.05.017","volume":"118","author":"L Zhou","year":"2012","unstructured":"Zhou L, Lee J, Wen Y, Constantinou CE, Murayama Y, Omata S, Chen B (2012) Biomechanical properties and associated collagen composition in vaginal tissue of women with pelvic organ prolapse. J Urol 118(3):875\u2013880","journal-title":"J Urol"},{"issue":"7","key":"2207_CR24","doi-asserted-by":"publisher","first-page":"593","DOI":"10.1007\/s11517-006-0069-6","volume":"44","author":"V Jalkanen","year":"2006","unstructured":"Jalkanen V, Andersson BM, Bergh A, Ljungberg B, Lindahl OA (2006) Prostate tissue stiffness as measured with a resonance sensorsystem: a study on silicone and human prostate tissue in vitro. Med Biol Eng Comput 44(7):593\u2013603","journal-title":"Med Biol Eng Comput"},{"issue":"2","key":"2207_CR25","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1002\/rcs.1879","volume":"14","author":"T Fukuda","year":"2018","unstructured":"Fukuda T, Tanaka Y, Kappers A, Fujiwara M, Sano A (2018) Visual and tactile feedback for a direct-manipulating tactile sensor in laparoscopic palpation. Int J Med Robot Comput Assist Surg 14(2):1\u201313","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"2207_CR26","doi-asserted-by":"crossref","unstructured":"Kimura F, Yamamoto A, Higuchi T (2010) Development of a 2-DOF softness feeling display for tactile tele-presentation of deformable surfaces. In: Proceeding of IEEE international conference on robotics and automation. pp 1822\u20131827","DOI":"10.1109\/ROBOT.2010.5509688"},{"issue":"2","key":"2207_CR27","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1109\/TOH.2015.2404353","volume":"8","author":"M Bianchi","year":"2015","unstructured":"Bianchi M, Serio A (2015) Design and characterization of a fabric-based softness display. IEEE Trans Haptics 8(2):152\u2013163","journal-title":"IEEE Trans Haptics"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02207-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02207-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02207-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,6,8]],"date-time":"2021-06-08T00:10:10Z","timestamp":1623111010000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02207-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6,8]]},"references-count":27,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2020,9]]}},"alternative-id":["2207"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02207-x","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2020,6,8]]},"assertion":[{"value":"12 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"27 May 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"8 June 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the research ethics committee of Nagoya Institute of Technology and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}