{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,5]],"date-time":"2026-03-05T03:25:04Z","timestamp":1772681104754,"version":"3.50.1"},"reference-count":15,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,7,28]],"date-time":"2020-07-28T00:00:00Z","timestamp":1595894400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,7,28]],"date-time":"2020-07-28T00:00:00Z","timestamp":1595894400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s11548-020-02234-8","type":"journal-article","created":{"date-parts":[[2020,7,28]],"date-time":"2020-07-28T17:26:17Z","timestamp":1595957177000},"page":"1719-1725","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":18,"title":["A surgical navigated cutting guide for mandibular osteotomies: accuracy and reproducibility of an image-guided mandibular osteotomy"],"prefix":"10.1007","volume":"15","author":[{"given":"Timon Peter","family":"ter Braak","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0171-6759","authenticated-orcid":false,"given":"Susan Gijsbertje","family":"Brouwer de Koning","sequence":"additional","affiliation":[]},{"given":"Maarten Jan Antony","family":"van Alphen","sequence":"additional","affiliation":[]},{"given":"Ferdinand","family":"van der Heijden","sequence":"additional","affiliation":[]},{"given":"Willem Hans","family":"Schreuder","sequence":"additional","affiliation":[]},{"given":"Robert Leonardus Petrus","family":"van Veen","sequence":"additional","affiliation":[]},{"given":"Munir Baris","family":"Karakullukcu","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,7,28]]},"reference":[{"key":"2234_CR1","doi-asserted-by":"publisher","first-page":"133","DOI":"10.1016\/j.oraloncology.2017.11.011","volume":"75","author":"T Bao","year":"2017","unstructured":"Bao T, He J, Yu C, Zhao W, Lin Y, Wang H, Liu J, Zhu H (2017) Utilization of a pre-bent plate-positioning surgical guide system in precise mandibular reconstruction with a free fibula flap. Oral Oncol 75:133\u2013139. https:\/\/doi.org\/10.1016\/j.oraloncology.2017.11.011","journal-title":"Oral Oncol"},{"key":"2234_CR2","doi-asserted-by":"publisher","first-page":"2824","DOI":"10.1016\/j.joms.2010.06.177","volume":"68","author":"SM Roser","year":"2010","unstructured":"Roser SM, Ramachandra S, Blair H, Grist W, Carlson GW, Christensen AM, Weimer KA, Steed MB (2010) The accuracy of virtual surgical planning in free fibula mandibular reconstruction: comparison of planned and final results. J Oral Maxillofac Surg 68:2824\u20132832. https:\/\/doi.org\/10.1016\/j.joms.2010.06.177","journal-title":"J Oral Maxillofac Surg"},{"key":"2234_CR3","doi-asserted-by":"publisher","first-page":"1171","DOI":"10.1016\/j.bjps.2014.04.038","volume":"67","author":"KA Rodby","year":"2014","unstructured":"Rodby KA, Turin S, Jacobs RJ, Cruz JF, Hassid VJ, Kolokythas A, Antony AK (2014) Advances in oncologic head and neck reconstruction: systematic review and future considerations of virtual surgical planning and computer aided design\/computer aided modeling. J Plast Reconstr Aesthet Surg 67:1171\u20131185. https:\/\/doi.org\/10.1016\/j.bjps.2014.04.038","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"2234_CR4","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1097\/PRS.0b013e31828bd6b0","volume":"131","author":"S Mazzoni","year":"2013","unstructured":"Mazzoni S, Marchetti C, Sgarzani R, Cipriani R, Scotti R, Ciocca L (2013) Prosthetically guided maxillofacial surgery: evaluation of the accuracy of a surgical guide and custom-made bone plate in oncology patients after mandibular reconstruction. Plast Reconstr Surg 131:1376\u20131385. https:\/\/doi.org\/10.1097\/PRS.0b013e31828bd6b0","journal-title":"Plast Reconstr Surg"},{"key":"2234_CR5","doi-asserted-by":"publisher","first-page":"2049","DOI":"10.1016\/j.jcms.2014.09.014","volume":"42","author":"J Rustemeyer","year":"2014","unstructured":"Rustemeyer J, Melenberg A, Sari-Rieger A (2014) Costs incurred by applying computer-aided design\/computer-aided manufacturing techniques for the reconstruction of maxillofacial defects. J Cranio-Maxillofac Surg 42:2049\u20132055. https:\/\/doi.org\/10.1016\/j.jcms.2014.09.014","journal-title":"J Cranio-Maxillofac Surg"},{"key":"2234_CR6","doi-asserted-by":"publisher","first-page":"793","DOI":"10.1016\/j.ijom.2015.12.018","volume":"45","author":"P Pietruski","year":"2016","unstructured":"Pietruski P, Majak M, Swiatek-Najwer E, Popek M, Szram D, Zuk M, Jaworowski J (2016) Accuracy of experimental mandibular osteotomy using the image-guided sagittal saw. Int J Oral Maxillofac Surg 45:793\u2013800. https:\/\/doi.org\/10.1016\/j.ijom.2015.12.018","journal-title":"Int J Oral Maxillofac Surg"},{"key":"2234_CR7","doi-asserted-by":"publisher","first-page":"e0173111","DOI":"10.1371\/journal.pone.0173111","volume":"12","author":"JM Bernstein","year":"2017","unstructured":"Bernstein JM, Daly MJ, Chan H, Qiu J, Goldstein D, Muhanna N, De Almeida JR, Irish JC (2017) Accuracy and reproducibility of virtual cutting guides and 3D-navigation for osteotomies of the mandible and maxilla. PLoS ONE 12:e0173111. https:\/\/doi.org\/10.1371\/journal.pone.0173111","journal-title":"PLoS ONE"},{"key":"2234_CR8","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.1016\/j.jcms.2015.06.012","volume":"43","author":"P Pietruski","year":"2015","unstructured":"Pietruski P, Majak M, Swiatek-Najwer E, Popek M, Jaworowski J, Zuk M, Nowakowski F (2015) Image-guided bone resection as a prospective alternative to cutting templates\u2014a preliminary study. J Cranio-Maxillofac Surg 43:1021\u20131027. https:\/\/doi.org\/10.1016\/j.jcms.2015.06.012","journal-title":"J Cranio-Maxillofac Surg"},{"key":"2234_CR9","doi-asserted-by":"publisher","first-page":"510","DOI":"10.1002\/jso.25351","volume":"119","author":"J Nijkamp","year":"2019","unstructured":"Nijkamp J, Kuhlmann KFD, Ivashchenko O, Pouw B, Hoetjes N, Lindenberg MA, Aalbers AGJ, Beets GL, van Coevorden F, KoK N, Ruers TJM (2019) Prospective study on image-guided navigation surgery for pelvic malignancies. J Surg Oncol 119:510\u2013517. https:\/\/doi.org\/10.1002\/jso.25351","journal-title":"J Surg Oncol"},{"key":"2234_CR10","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J, Aylward S, Miller JV, Pieper S, Kikinis R (2012) 3D slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30:1323\u20131341. https:\/\/doi.org\/10.1016\/j.mri.2012.05.001","journal-title":"Magn Reson Imaging"},{"key":"2234_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.ijom.2020.06.013","author":"SG Brouwer de Koning","year":"2019","unstructured":"Brouwer de Koning SG, ter Braak TP, Geldof F, van Veen RLP, van Alphen MJA, Karssemakers LHE, Ruers TJM, Schreuder WH, Karakullukcu MB (2019) Evaluating the accuracy of resection planes in mandibular surgery using a preoperative, intraoperative, and postoperative approach. Int J Oral Maxillofac Surg. https:\/\/doi.org\/10.1016\/j.ijom.2020.06.013","journal-title":"Int J Oral Maxillofac Surg"},{"key":"2234_CR12","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1016\/j.bjps.2018.03.018","volume":"71","author":"M Zhu","year":"2018","unstructured":"Zhu M, Liu F, Zhou C, Lin L, Zhang Y, Chai G, Xie L, Qi F, Li Q (2018) Does intraoperative navigation improve the accuracy of mandibular angle osteotomy: comparison between augmented reality navigation, individualised templates and free-hand techniques. J Plast Reconstr Aesthet Surg 71:1188\u20131195. https:\/\/doi.org\/10.1016\/j.bjps.2018.03.018","journal-title":"J Plast Reconstr Aesthet Surg"},{"key":"2234_CR13","doi-asserted-by":"publisher","first-page":"905","DOI":"10.1118\/1.1469625","volume":"29","author":"A Wagner","year":"2002","unstructured":"Wagner A, Schicho K, Birkfellner W, Figl M, Seemann R, K\u00f6nig F, Kainberger F, Ewers R (2002) Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems. Med Phys 29:905\u2013912. https:\/\/doi.org\/10.1118\/1.1469625","journal-title":"Med Phys"},{"key":"2234_CR14","doi-asserted-by":"publisher","first-page":"156","DOI":"10.1016\/j.jcms.2011.03.003","volume":"40","author":"R Seeberger","year":"2012","unstructured":"Seeberger R, Kane G, Hoffmann J, Eggers G (2012) Accuracy assessment for navigated maxillo-facial surgery using an electromagnetic tracking device. J Cranio-Maxillofac Surg 40:156\u2013161. https:\/\/doi.org\/10.1016\/j.jcms.2011.03.003","journal-title":"J Cranio-Maxillofac Surg"},{"key":"2234_CR15","doi-asserted-by":"publisher","first-page":"854","DOI":"10.1016\/j.jcms.2019.03.004","volume":"47","author":"P Pietruski","year":"2019","unstructured":"Pietruski P, Majak M, \u015awiatek-Najwer E, \u017buk M, Popek M, Mazurek M, \u015awiecka M, Jaworowski J (2019) Supporting mandibular resection with intraoperative navigation utilizing augmented reality technology\u2014a proof of concept study. J Cranio-Maxillofac Surg 47:854\u2013859. https:\/\/doi.org\/10.1016\/j.jcms.2019.03.004","journal-title":"J Cranio-Maxillofac Surg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02234-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02234-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02234-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,27]],"date-time":"2021-07-27T23:49:58Z","timestamp":1627429798000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02234-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,28]]},"references-count":15,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["2234"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02234-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,7,28]]},"assertion":[{"value":"16 April 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"The authors declare that they have no conflict of interest.","order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}