{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,2,21]],"date-time":"2025-02-21T13:24:55Z","timestamp":1740144295635,"version":"3.37.3"},"reference-count":19,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,7,30]],"date-time":"2020-07-30T00:00:00Z","timestamp":1596067200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,7,30]],"date-time":"2020-07-30T00:00:00Z","timestamp":1596067200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["Grant-in-Aid for Scientific Research (B) 16H03191"],"award-info":[{"award-number":["Grant-in-Aid for Scientific Research (B) 16H03191"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s11548-020-02239-3","type":"journal-article","created":{"date-parts":[[2020,7,30]],"date-time":"2020-07-30T11:28:10Z","timestamp":1596108490000},"page":"1653-1664","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["Suction-fixing surgical device for assisting liver manipulation with laparoscopic forceps"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3067-6290","authenticated-orcid":false,"given":"Yoshikazu","family":"Nakajima","sequence":"first","affiliation":[]},{"given":"Rina","family":"Suzuki","sequence":"additional","affiliation":[]},{"given":"Yutaro","family":"Suzuki","sequence":"additional","affiliation":[]},{"given":"Takaaki","family":"Sugino","sequence":"additional","affiliation":[]},{"given":"Toshihiro","family":"Kawase","sequence":"additional","affiliation":[]},{"given":"Shinya","family":"Onogi","sequence":"additional","affiliation":[]},{"given":"Haruna","family":"Seki","sequence":"additional","affiliation":[]},{"given":"Tatsuki","family":"Fujiwara","sequence":"additional","affiliation":[]},{"given":"Katsuhiro","family":"Ouchi","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,7,30]]},"reference":[{"issue":"3","key":"2239_CR1","first-page":"1","volume":"2","author":"Y Yamamoto","year":"2015","unstructured":"Yamamoto Y, Nakamura R (2015) Two-way least-incision transformable end-effector graspers for robot-assisted surgery. ROBOMECH J 2(3):1\u20136","journal-title":"ROBOMECH J"},{"key":"2239_CR2","doi-asserted-by":"crossref","unstructured":"Osaki M, Omata T, Takayama T, Ohizumi H (2011) Transformable lung positioner for thoracoscopic surgery. In: IEEE\/SICE international symposium on system integration, pp 138\u2013143","DOI":"10.1109\/SII.2011.6147434"},{"key":"2239_CR3","unstructured":"Kuwahara K, Tsukagoshi H, Kitagawa A (2013) A soft finger with the function of attaching and holding internal organs referring to an octopus sucker. In: Proceedings of the JSME conference on robotics and mechatronics, no. 13-2"},{"key":"2239_CR4","doi-asserted-by":"crossref","unstructured":"Katayama T, Kuroda K, Omata T (2014) Suction hand for grasping large internal organs for laparoscopic surgery. In: Proceedings of the 2014 JSME conference on robotics and mechatronics, Toyama, Japan, May 25\u201329, 3P1-C02(1)-(2)","DOI":"10.1299\/jsmermd.2014._3P1-C02_1"},{"key":"2239_CR5","doi-asserted-by":"publisher","first-page":"331","DOI":"10.1007\/s00464-013-3178-y","volume":"28","author":"P Gan","year":"2014","unstructured":"Gan P (2014) A novel liver retractor for reduced or single-port laparoscopic surgery. Surg Endosc 28:331\u2013335","journal-title":"Surg Endosc"},{"key":"2239_CR6","doi-asserted-by":"crossref","unstructured":"Cheng N, Ishigami G, Hawthorne S, Chen H, Hansen M, Telleria M, Playter R, Iagnemma K (2010) Design and analysis of a soft mobile robot composed of multiple thermally activated joints driven by a single actuator. In: Proceedings of the 2010 IEEE international conference on robot and automation, Anchorage, USA, pp 5207\u20135212","DOI":"10.1109\/ROBOT.2010.5509247"},{"key":"2239_CR7","doi-asserted-by":"crossref","unstructured":"Yamanaka N, Matsumiya K, Masamune K, Dohi T, Yamashita H, Chiba T, Liao H (2007) Balloon-based manipulator with multiple linkages for intrauterine surgery. In: Proceedings of the 2007 IEEE\/RSJ international conference on intelligent robots system, San Diego, USA, pp 1278\u20131283","DOI":"10.1109\/IROS.2007.4399620"},{"key":"2239_CR8","doi-asserted-by":"crossref","unstructured":"Degani A, Choset H, Zubiate B, Ota T, Zenati M (2006) Highly articulated robotic probe for minimally invasive surgery. In: Proceedings of the 2006 IEEE international conference on robotics and automation, Orlando, USA, pp 4167\u20134172","DOI":"10.1109\/ROBOT.2006.1642343"},{"issue":"2","key":"2239_CR9","doi-asserted-by":"publisher","first-page":"382","DOI":"10.1109\/TRO.2013.2287975","volume":"30","author":"YJ Kim","year":"2014","unstructured":"Kim YJ, Cheng S, Kim S, Iagnemma K (2014) A stiffness-adjustable hyperredundant manipulator using a variable neutral-line mechanism for minimally invasive surgery. IEEE Trans Robot 30(2):382\u2013395","journal-title":"IEEE Trans Robot"},{"issue":"3","key":"2239_CR10","doi-asserted-by":"publisher","first-page":"181","DOI":"10.1108\/01439910010371597","volume":"27","author":"W Townsend","year":"2000","unstructured":"Townsend W (2000) The BarrettHand grasper\u2014programmably flexible part handling and assembly. Ind Robot 27(3):181\u2013188","journal-title":"Ind Robot"},{"issue":"2","key":"2239_CR11","doi-asserted-by":"publisher","first-page":"341","DOI":"10.1109\/TRO.2011.2171093","volume":"28","author":"JR Amend","year":"2012","unstructured":"Amend JR, Brown E, Rodenberg N, Jaeger HM, Kipson H (2012) A positive pressure universal gripper based on the jamming of granular material. IEEE Trans Robot 28(2):341\u2013350","journal-title":"IEEE Trans Robot"},{"key":"2239_CR12","doi-asserted-by":"crossref","unstructured":"Jiang A, Xynogalas G, Dasupta P, Althoefer K, Nanayakkara T (2012) Design of a variable stiffness flexible manipulator with composite granular jamming and membrane coupling. In: IEEE\/RSJ international conference on intelligent robots and systems, pp 2922\u20132927","DOI":"10.1109\/IROS.2012.6385696"},{"key":"2239_CR13","doi-asserted-by":"crossref","unstructured":"Shepherd MK, Rouse EJ (2017) Design of quasi-passive ankle-foot prosthesis with biomimetic, variable stiffness. In: IEEE international conference on robotics and automation (ICRA), pp 6672\u20136678","DOI":"10.1109\/ICRA.2017.7989788"},{"issue":"4","key":"2239_CR14","doi-asserted-by":"publisher","first-page":"1031","DOI":"10.1109\/TRO.2013.2256313","volume":"29","author":"YJ Kim","year":"2013","unstructured":"Kim YJ, Cheng S, Kim S, Iagnemma K (2013) A novel layer jamming mechanism with stiffness-tuning capability or minimally invasive surgery. IEEE Trans Robot 29(4):1031\u20131042","journal-title":"IEEE Trans Robot"},{"key":"2239_CR15","doi-asserted-by":"publisher","first-page":"857","DOI":"10.1007\/s11548-014-0981-4","volume":"9","author":"S Zuo","year":"2014","unstructured":"Zuo S, Iijima K, Tokumiya T, Masamune K (2014) Variable stiffness outer sheath with \u201cDragon skin\u201d structure and negative pneumatic shape-locking mechanism. Int J CARS 9:857\u2013865","journal-title":"Int J CARS"},{"issue":"1","key":"2239_CR16","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1109\/TMECH.2017.2777507","volume":"23","author":"J Kim","year":"2018","unstructured":"Kim J, Nakajima Y, Kobayashi K (2018) A suction-fixing, stiffness-tunable liver manipulator for laparoscopic surgeries. IEEE\/ASME Trans Mechatron 23(1):262\u2013273","journal-title":"IEEE\/ASME Trans Mechatron"},{"key":"2239_CR17","doi-asserted-by":"crossref","unstructured":"Kim J (2018) Suction-fixing and stiffness-tunable liver retractor for laparoscopic surgeries. A doctoral thesis in the University of Tokyo. http:\/\/doi.org\/10.15083\/00078124","DOI":"10.1109\/TMECH.2017.2777507"},{"issue":"5","key":"2239_CR18","doi-asserted-by":"publisher","first-page":"858","DOI":"10.1016\/j.jsurg.2016.04.009","volume":"73","author":"MSR Prasad","year":"2016","unstructured":"Prasad MSR, Manivannan M, Manoharan G, Chandramohan SM (2016) Objective assessment of laparoscopic force and psychomotor skills in a novel virtual reality-based haptic simulator. J Surg Educ 73(5):858\u2013869","journal-title":"J Surg Educ"},{"issue":"12","key":"2239_CR19","doi-asserted-by":"publisher","first-page":"e84466","DOI":"10.1371\/journal.pone.0084466","volume":"8","author":"T Horeman","year":"2013","unstructured":"Horeman T, Meijer E, Harlaar JJ, Lange JF, van den Dobbesteen JJ, Dankelman J (2013) Force sensing in surgical sutures. PLoS ONE 8(12):e84466","journal-title":"PLoS ONE"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02239-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02239-3\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02239-3.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,7,29]],"date-time":"2021-07-29T23:17:53Z","timestamp":1627600673000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02239-3"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,7,30]]},"references-count":19,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["2239"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02239-3","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2020,7,30]]},"assertion":[{"value":"14 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"14 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"30 July 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All applicable international, national and\/or institutional guidelines for the care and use of animals were followed. All procedures performed in studies involving animals were in accordance with the ethical standards of the institution or practice at which the studies were conducted. This article does not contain patient data.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}}]}}