{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,9]],"date-time":"2026-01-09T23:26:50Z","timestamp":1768001210956,"version":"3.49.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2020,8,7]],"date-time":"2020-08-07T00:00:00Z","timestamp":1596758400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,8,7]],"date-time":"2020-08-07T00:00:00Z","timestamp":1596758400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/100009734","name":"Olympus","doi-asserted-by":"publisher","award":["30,000USD"],"award-info":[{"award-number":["30,000USD"]}],"id":[{"id":"10.13039\/100009734","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,10]]},"DOI":"10.1007\/s11548-020-02241-9","type":"journal-article","created":{"date-parts":[[2020,8,7]],"date-time":"2020-08-07T20:02:26Z","timestamp":1596830546000},"page":"1619-1630","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":32,"title":["A visual SLAM-based bronchoscope tracking scheme for bronchoscopic navigation"],"prefix":"10.1007","volume":"15","author":[{"given":"Cheng","family":"Wang","sequence":"first","affiliation":[]},{"given":"Masahiro","family":"Oda","sequence":"additional","affiliation":[]},{"given":"Yuichiro","family":"Hayashi","sequence":"additional","affiliation":[]},{"given":"Benjamin","family":"Villard","sequence":"additional","affiliation":[]},{"given":"Takayuki","family":"Kitasaka","sequence":"additional","affiliation":[]},{"given":"Hirotsugu","family":"Takabatake","sequence":"additional","affiliation":[]},{"given":"Masaki","family":"Mori","sequence":"additional","affiliation":[]},{"given":"Hirotoshi","family":"Honma","sequence":"additional","affiliation":[]},{"given":"Hiroshi","family":"Natori","sequence":"additional","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0100-4797","authenticated-orcid":false,"given":"Kensaku","family":"Mori","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2020,8,7]]},"reference":[{"issue":"13","key":"2241_CR1","first-page":"2785","volume":"124","author":"AC Kathleen","year":"2018","unstructured":"Kathleen AC, Andrew JL, Susan S, Recinda LS, Anne-Michelle N, Nadia H, Jane SH, Robert NA, Albert UF, Jiemin M, Betsy AK, Ahmedin J (2018) Annual report to the nation on the status of cancer, part I: National cancer statistics. Am Cancer Soc 124(13):2785\u20132800","journal-title":"Am Cancer Soc"},{"issue":"5","key":"2241_CR2","doi-asserted-by":"publisher","first-page":"703","DOI":"10.1109\/42.736022","volume":"17","author":"I Bricault","year":"1998","unstructured":"Bricault I, Ferretti G, Cinquin P (1998) Registration of real and CT-derived virtual bronchoscopic images to assist transbronchial biopsy. IEEE Trans Med Imaging 17(5):703\u2013714","journal-title":"IEEE Trans Med Imaging"},{"issue":"4","key":"2241_CR3","doi-asserted-by":"publisher","first-page":"621","DOI":"10.1016\/j.media.2009.06.001","volume":"13","author":"D Deguchi","year":"2009","unstructured":"Deguchi D, Mori K, Feuerstein M, Kitasaka T, Maurer CR, Suenaga Y, Takabatake H, Mori M, Natori H (2009) Selective image similarity measure for bronchoscope tracking based on image registration. Med Image Anal 13(4):621\u2013633","journal-title":"Med Image Anal"},{"key":"2241_CR4","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1177\/1753466619841234","volume":"13","author":"MR Bowling","year":"2019","unstructured":"Bowling MR, Folch EE, Khandhar SJ, Kazakov J, Krimsky WS, LeMense GP, Linden PA, Murillo BA, Nead MA, Pritchett MA, Teba CV, Towe CW, Williams T, Anciano CJ (2019) Fiducial marker placement with electromagnetic navigation bronchoscopy: a subgroup analysis of the prospective, multicenter NAVIGATE study. Ther Adv Respir Dis 13:1\u201311","journal-title":"Ther Adv Respir Dis"},{"issue":"8","key":"2241_CR5","doi-asserted-by":"publisher","first-page":"1376","DOI":"10.1109\/TMI.2013.2252361","volume":"32","author":"SA Merritt","year":"2013","unstructured":"Merritt SA, Khare R, Bascom R, Higgins WE (2013) Interactive CT-video registration for the continuous guidance of bronchoscopy. IEEE Trans Med Imaging 32(8):1376\u20131396","journal-title":"IEEE Trans Med Imaging"},{"key":"2241_CR6","unstructured":"Gilboa P, Blecher D (2004) Intrabody navigation system for medical applications, Google Patents. Patent number: US Patent 6,833,814. Dec. 21, 2004"},{"issue":"5","key":"2241_CR7","doi-asserted-by":"publisher","first-page":"1194","DOI":"10.2214\/AJR.10.5151","volume":"196","author":"L Appelbaum","year":"2011","unstructured":"Appelbaum L, Sosna J, Nissenbaum Y, Benshtein A, Goldberg SN (2011) Electromagnetic navigation system for CT-guided biopsy of small lesions. Am J Roentgenol 196(5):1194\u20131200","journal-title":"Am J Roentgenol"},{"issue":"3","key":"2241_CR8","doi-asserted-by":"publisher","first-page":"371","DOI":"10.1007\/s11548-011-0645-6","volume":"7","author":"X Luo","year":"2012","unstructured":"Luo X, Feuerstein M, Kitasaka T, Mori K (2012) Robust bronchoscope motion tracking using sequential Monte Carlo methods in navigated bronchoscopy: dynamic phantom and patient validation. Int J Comput Assist Radiol Surg 7(3):371\u2013387","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2241_CR9","doi-asserted-by":"crossref","unstructured":"Deguchi D, Mori K, Hasegawa J, Toriwaki J, Takabatake H, Natori H (2002) Camera motion tracking of real bronchoscope using epipolar geometry analysis and CT-derived bronchoscopic images. In: Medical imaging 2002: physiology and function from multidimensional images, vol 4683, pp 30\u201342","DOI":"10.1117\/12.463591"},{"issue":"1","key":"2241_CR10","doi-asserted-by":"publisher","first-page":"85","DOI":"10.1109\/TBME.2013.2277609","volume":"61","author":"X Luo","year":"2014","unstructured":"Luo X, Mori K (2014) Robust endoscope motion estimation via an animated particle filter for electromagnetically navigated endoscopy. IEEE Trans Biomed Eng 61(1):85\u201395","journal-title":"IEEE Trans Biomed Eng"},{"key":"2241_CR11","first-page":"644","volume":"4792","author":"K Mori","year":"2007","unstructured":"Mori K, Deguchi D, Ishitani K, Kitasaka T, Suenaga Y, Hasegawa Y, Imaizumi K, Takabatake H (2007) Bronchoscope tracking without fiducial markers using ultra-tiny electromagnetic tracking system and its evaluation in different environments. Int Conf Med Image Comput Comput Assis Interv 4792:644\u2013651","journal-title":"Int Conf Med Image Comput Comput Assis Interv"},{"key":"2241_CR12","first-page":"543","volume":"3750","author":"K Mori","year":"2005","unstructured":"Mori K, Deguchi D, Akiyama K (2005) Hybrid bronchoscope tracking using a magnetic tracking sensor and image registration. Int Conf Med Image Comput Comput Assis Interv 3750:543\u2013550","journal-title":"Int Conf Med Image Comput Comput Assis Interv"},{"issue":"3","key":"2241_CR13","doi-asserted-by":"publisher","first-page":"359","DOI":"10.1007\/s11548-011-0626-9","volume":"7","author":"D Deguchi","year":"2012","unstructured":"Deguchi D, Feuerstein M, Kitasaka T, Suenaga Y, Ide I, Murase H, Imaizumi K, Hasegawa Y, Mori K (2012) Real-time marker-free patient registration for electromagnetic navigated bronchoscopy: a phantom study. Int J Comput Assist Radiol Surg 7(3):359\u2013369","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"6","key":"2241_CR14","doi-asserted-by":"publisher","first-page":"1248","DOI":"10.1109\/TMI.2014.2307052","volume":"33","author":"X Luo","year":"2014","unstructured":"Luo X, Mori K (2014) A discriminative structural similarity measure and its application to video-volume registration for endoscope three-dimensional motion tracking. IEEE Trans Med Imaging 33(6):1248\u20131261","journal-title":"IEEE Trans Med Imaging"},{"issue":"3","key":"2241_CR15","doi-asserted-by":"publisher","first-page":"379","DOI":"10.3390\/jcm8030379","volume":"8","author":"SW Kuo","year":"2019","unstructured":"Kuo SW, TsengYF Dai KY, Chang YC, Chen KC, Lee JM (2019) Electromagnetic navigation bronchoscopy localization versus percutaneous CT-guided localization for lung resection via video-assisted thoracoscopic surgery: a propensity-matched study. J Clin Med 8(3):379","journal-title":"J Clin Med"},{"issue":"3","key":"2241_CR16","doi-asserted-by":"publisher","first-page":"321","DOI":"10.1016\/S1361-8415(02)00089-0","volume":"6","author":"K Mori","year":"2002","unstructured":"Mori K, Deguchi D, Sugiyama J, Suenaga Y, Toriwaki J, Maurer JCR, Takabatake H, Natori H (2002) Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images. Med Image Anal 6(3):321\u2013336","journal-title":"Med Image Anal"},{"key":"2241_CR17","doi-asserted-by":"crossref","unstructured":"Wegner I, Biederer J, Tetzlaff R, Wolf I, Meinzer HP (2007) Evaluation and extension of a navigation system for bronchoscopy inside human lungs. In: Medical imaging 2007: international society for optics and photonics, visualization and image-guided procedures, p 65091H","DOI":"10.1117\/12.708199"},{"key":"2241_CR18","first-page":"11","volume":"13","author":"C Wang","year":"2018","unstructured":"Wang C, Oda M, Hayashi Y, Kitasaka T, Honma H, Takabatake H, Mori M, Natori H, Mori K (2018) Improvement of robustness of SLAM-based bronchoscope tracking by posture guided feature matching. Int J Comput Assist Radiol Surg (CARS) 2018 13:11\u201312","journal-title":"Int J Comput Assist Radiol Surg (CARS) 2018"},{"key":"2241_CR19","doi-asserted-by":"crossref","unstructured":"Davison AJ (2003) Real-time simultaneous localisation and mapping with a single camera. In: International conference on computer vision, pp 1403\u20131410","DOI":"10.1109\/ICCV.2003.1238654"},{"key":"2241_CR20","doi-asserted-by":"crossref","unstructured":"Engel, J, Schops T, Cremers D (2014) LSD-SLAM: large-scale direct monocular SLAM. In: European conference on computer vision, pp 834\u2013849","DOI":"10.1007\/978-3-319-10605-2_54"},{"key":"2241_CR21","doi-asserted-by":"crossref","unstructured":"Newcombe RA, Lovegrove SJ, Davison AJ (2011) DTAM: dense tracking and mapping in real-time. In: 2011 International conference on computer vision, pp 2320\u20132327","DOI":"10.1109\/ICCV.2011.6126513"},{"issue":"5","key":"2241_CR22","doi-asserted-by":"publisher","first-page":"1147","DOI":"10.1109\/TRO.2015.2463671","volume":"31","author":"R Mur-Artal","year":"2015","unstructured":"Mur-Artal R, Montiel JMM, Tardos JD (2015) ORB-SLAM: a versatile and accurate monocular SLAM system. IEEE Trans Robot 31(5):1147\u20131163","journal-title":"IEEE Trans Robot"},{"key":"2241_CR23","doi-asserted-by":"crossref","unstructured":"Rublee E, Rabaud V, Konolige K, Bradski G (2011) ORB: an efficient alternative to SIFT or SURF. In: IEEE International conference on computer vision (ICCV), 2011, pp 2564\u20132571","DOI":"10.1109\/ICCV.2011.6126544"},{"issue":"3","key":"2241_CR24","first-page":"187","volume":"26","author":"Y Nimura","year":"2008","unstructured":"Nimura Y (2008) PLUTO: a common platform for computer-aided diagnosis. Med Imag Tech 26(3):187\u2013191","journal-title":"Med Imag Tech"},{"issue":"11","key":"2241_CR25","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1109\/34.888718","volume":"22","author":"Z Zhang","year":"2000","unstructured":"Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22(11):1330\u20131334","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"2241_CR26","doi-asserted-by":"crossref","unstructured":"Mori K, Suenaga Y, Toriwaki J (2002) Fast volume rendering based on software optimisation using multimedia instructions on PC platforms. In: Lemke HU, Vannier MW, Inamura K, Farman K, Doi K, Reiber JHC (eds) CARS 2002. Springer, Berlin, pp 467\u2013472","DOI":"10.1007\/978-3-642-56168-9_78"},{"key":"2241_CR27","doi-asserted-by":"crossref","unstructured":"Mori K, Suenaga Y and Toriwaki J (2003) Fast software-based volume rendering using multimedia instructions on PC platforms and its application to virtual endoscopy. In Medical imaging 2003: physiology and function: methods, systems, and applications, vol 5031, pp 111\u2013122","DOI":"10.1117\/12.480417"},{"issue":"3","key":"2241_CR28","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1109\/38.511","volume":"8","author":"M Levoy","year":"1988","unstructured":"Levoy M (1988) Display of surfaces from volume data. IEEE Comput Graph Appl 8(3):29\u201337","journal-title":"IEEE Comput Graph Appl"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02241-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02241-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02241-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,6]],"date-time":"2021-08-06T23:51:03Z","timestamp":1628293863000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02241-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,7]]},"references-count":28,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2020,10]]}},"alternative-id":["2241"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02241-9","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,7]]},"assertion":[{"value":"13 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 July 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"7 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"K. Mori is receiving research funding from Olympus (Grant No. 30,000USD).","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain any patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}