{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,4]],"date-time":"2026-03-04T03:36:16Z","timestamp":1772595376884,"version":"3.50.1"},"reference-count":45,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T00:00:00Z","timestamp":1598572800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["EXC 2177\/1"],"award-info":[{"award-number":["EXC 2177\/1"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Medizinische Hochschule Hannover (MHH)"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,11]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Automated insertion of electrode arrays (EA) in cochlear implant surgery is presumed to be less traumatic than manual insertions, but no tool is widely available in the operating room. We sought (1) to design and create a simple tool able to automate the EA insertion process; and (2) to perform preliminary evaluations of the designed prototype.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A first prototype of a tool with maximum simplicity was designed and fabricated to take advantage of hydraulic actuation. The prototype facilitates automated forward motion using a syringe connected to an infusion pump. Initial prototype evaluation included: (1) testing of forward motion at different velocities (2) EA insertion trials into an artificial cochlear model with force recordings, and (3) evaluation of device handling, fixation and positioning using cadaver head specimens and a surgical retractor. Alignment of the tool was explored with CT imaging.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>In this initial phase, the prototype demonstrated easy assembly and ability to respond to hydraulic actuation driven by an infusion pump at different velocities. EA insertions at an ultra-slow velocity of 0.03\u00a0mm\/s revealed smooth force profiles with mean maximum force of 0.060\u00a0N\u2009\u00b1\u20090.007\u00a0N. Device positioning with an appropriate insertion axis into the cochlea was deemed feasible and easy to achieve.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Initial testing of our hydraulic insertion tool did not reveal any serious complications that contradict the initially defined design specifications. Further meticulous testing is needed to determine the safety of the device, its reliability and clinical applicability.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-020-02243-7","type":"journal-article","created":{"date-parts":[[2020,8,28]],"date-time":"2020-08-28T06:02:22Z","timestamp":1598594542000},"page":"1931-1939","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["A simple tool to automate the insertion process in cochlear implant surgery"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7223-3618","authenticated-orcid":false,"given":"Thomas S.","family":"Rau","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. Geraldine","family":"Zuniga","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Rolf","family":"Salcher","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Thomas","family":"Lenarz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,8,28]]},"reference":[{"key":"2243_CR1","doi-asserted-by":"publisher","first-page":"1791","DOI":"10.1002\/ar.22599","volume":"295","author":"H Rask-Andersen","year":"2012","unstructured":"Rask-Andersen H, Liu W, Erixon E, Kinnefors A, Pfaller K, Schrott-Fischer A, Glueckert R (2012) Human cochlea: anatomical characteristics and their relevance for cochlear implantation. Anat Rec 295:1791\u20131811","journal-title":"Anat Rec"},{"key":"2243_CR2","first-page":"11","volume":"64","author":"PS Roland","year":"2006","unstructured":"Roland PS, Wright CG (2006) Surgical aspects of cochlear implantation: mechanisms of insertional trauma. Adv Otorhinolaryngol 64:11\u201330","journal-title":"Adv Otorhinolaryngol"},{"issue":"4","key":"2243_CR3","doi-asserted-by":"publisher","first-page":"414","DOI":"10.1055\/s-0038-1670707","volume":"39","author":"C Welch","year":"2018","unstructured":"Welch C, Dillon MT, Pillsbury HC (2018) Electric and acoustic stimulation in cochlear implant recipients with hearing preservation. Semin Hear 39(4):414\u2013427","journal-title":"Semin Hear"},{"issue":"S1","key":"2243_CR4","doi-asserted-by":"publisher","first-page":"8","DOI":"10.1159\/000206490","volume":"14","author":"A B\u00fcchner","year":"2009","unstructured":"B\u00fcchner A, Sch\u00fcssler M, Battmer RD, St\u00f6ver T, Lesinski-Schiedat A, Lenarz T (2009) Impact of low-frequency hearing. Audiol Neurotol 14(S1):8\u201313","journal-title":"Audiol Neurotol"},{"issue":"2","key":"2243_CR5","doi-asserted-by":"publisher","first-page":"69","DOI":"10.1007\/s40136-013-0012-y","volume":"1","author":"AP Campbell","year":"2013","unstructured":"Campbell AP, Dillon MT, Buchman CA, Adunka OF (2013) Hearing preservation cochlear implantation. Curr Otorhinolaryngol Rep 1(2):69\u201379","journal-title":"Curr Otorhinolaryngol Rep"},{"issue":"suppl 2","key":"2243_CR6","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1159\/000327765","volume":"16","author":"CA Von Ilberg","year":"2011","unstructured":"Von Ilberg CA, Baumann U, Kiefer J, Tillein J, Adunka OF (2011) Electric-acoustic stimulation of the auditory system: a review of the first decade. Audiol Neurotol 16(suppl 2):1\u201330","journal-title":"Audiol Neurotol"},{"key":"2243_CR7","doi-asserted-by":"publisher","first-page":"3","DOI":"10.1177\/1084713813480857","volume":"17","author":"PV Incerti","year":"2013","unstructured":"Incerti PV, Ching TYC, Cowan R (2013) A systematic review of electric-acoustic stimulation: device fitting ranges, outcomes, and clinical fitting practices. Trends Amplif 17:3\u201326","journal-title":"Trends Amplif"},{"issue":"7","key":"2243_CR8","first-page":"356","volume":"41","author":"E Lehnhardt","year":"1993","unstructured":"Lehnhardt E (1993) Intracochlear placement of cochlear implant electrodes in soft surgery technique [in German]. HNO 41(7):356\u2013359","journal-title":"HNO"},{"key":"2243_CR9","first-page":"532570","volume-title":"Definition of metrics to evaluate cochlear array insertion forces performed with forceps, insertion tool, or motorized tool in temporal bone specimens","author":"Y Nguyen","year":"2014","unstructured":"Nguyen Y, Kazmitcheff G, De Seta D, Miroir M, Ferrary E, Sterkers O (2014) Definition of metrics to evaluate cochlear array insertion forces performed with forceps, insertion tool, or motorized tool in temporal bone specimens. Biomed Res, Int., p 532570"},{"key":"2243_CR10","doi-asserted-by":"publisher","first-page":"631","DOI":"10.1097\/MAO.0000000000002608","volume":"41","author":"CR Kaufmann","year":"2020","unstructured":"Kaufmann CR, Henslee AM, Claussen A, Hansen MR (2020) Evaluation of insertion forces and cochlea trauma following robotics-assisted cochlear implant electrode array insertion. Otol Neurotol. 41:631\u2013638","journal-title":"Otol Neurotol."},{"issue":"12","key":"2243_CR11","doi-asserted-by":"publisher","first-page":"2947","DOI":"10.1007\/s00405-018-5159-1","volume":"275","author":"S H\u00fcgl","year":"2018","unstructured":"H\u00fcgl S, R\u00fclander K, Lenarz T, Majdani O, Rau TS (2018) Investigation of ultra-low insertion speeds in an inelastic artificial cochlear model using custom-made cochlear implant electrodes. Eur Arch Oto Rhino Laryngol 275(12):2947\u20132956","journal-title":"Eur Arch Oto Rhino Laryngol"},{"issue":"3","key":"2243_CR12","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1177\/0194599817704391","volume":"157","author":"K Kesler","year":"2017","unstructured":"Kesler K, Dillon NP, Fichera L, Labadie RF (2017) Human kinematics of cochlear implant surgery: an investigation of insertion micro-motions and speed limitations. Otolaryngol Head Neck Surg (US) 157(3):493\u2013498","journal-title":"Otolaryngol Head Neck Surg (US)"},{"issue":"3","key":"2243_CR13","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1109\/10.748987","volume":"46","author":"SJ Rebscher","year":"1999","unstructured":"Rebscher SJ, Heilmann M, Bruszewski W, Talbot NH, Snyder RL, Merzenich MM (1999) Strategies to improve electrode positioning and safety in cochlear implants. IEEE Trans Biomed Eng 46(3):340\u2013352","journal-title":"IEEE Trans Biomed Eng"},{"issue":"8","key":"2243_CR14","doi-asserted-by":"publisher","first-page":"1325","DOI":"10.1097\/01.mlg.0000167993.05007.35","volume":"115","author":"JT Roland","year":"2005","unstructured":"Roland JT (2005) A model for cochlear implant electrode insertion and force evaluation: results with a new electrode design and insertion technique. Laryngoscope 115(8):1325\u20131339","journal-title":"Laryngoscope"},{"issue":"7","key":"2243_CR15","doi-asserted-by":"publisher","first-page":"1247","DOI":"10.1109\/TBME.2007.891937","volume":"54","author":"CA Todd","year":"2007","unstructured":"Todd CA, Naghdy F, Svehla MJ (2007) Force application during cochlear implant insertion: an analysis for improvement of surgeon technique. IEEE Trans Biomed Eng 54(7):1247\u20131255","journal-title":"IEEE Trans Biomed Eng"},{"issue":"8","key":"2243_CR16","doi-asserted-by":"publisher","first-page":"1199","DOI":"10.1097\/MAO.0b013e3181e7117e","volume":"31","author":"J Zhang","year":"2010","unstructured":"Zhang J, Wei W, Ding J, Roland JT, Manolidis S, Simaan N (2010) Inroads toward robot-assisted cochlear implant surgery using steerable electrode arrays. Otol Neurotol 31(8):1199\u20131206","journal-title":"Otol Neurotol"},{"issue":"1","key":"2243_CR17","doi-asserted-by":"publisher","first-page":"011008","DOI":"10.1115\/1.4007005","volume":"5","author":"J Zhang","year":"2013","unstructured":"Zhang J, Simaan N (2013) Design of underactuated steerable electrode arrays for optimal insertions. J Mech Robot 5(1):011008","journal-title":"J Mech Robot"},{"key":"2243_CR18","first-page":"5593","volume":"2008","author":"A Hussong","year":"2008","unstructured":"Hussong A, Rau TS, Eilers H, Baron S, Heimann B, Leinung M, Lenarz T, Majdani O (2008) Conception and design of an automated insertion tool for cochlear implants. Conf Proc IEEE Eng Med Biol Soc 2008:5593\u20135596","journal-title":"Conf Proc IEEE Eng Med Biol Soc"},{"key":"2243_CR19","doi-asserted-by":"crossref","unstructured":"Schurzig D, Labadie RF, Hussong A, Rau TS, Webster III, RJ (2010) A force sensing automated insertion tool for cochlear electrode implantation. In: Proceedings of the IEEE international conference robotics automation May 3\u20138, Anchorage, Alaska, USA, pp 3674\u20133679","DOI":"10.1109\/ROBOT.2010.5509341"},{"issue":"3","key":"2243_CR20","doi-asserted-by":"publisher","first-page":"481","DOI":"10.1007\/s11548-013-0936-1","volume":"9","author":"J-P Kobler","year":"2014","unstructured":"Kobler J-P, Beckmann D, Rau TS, Majdani O, Ortmaier T (2014) An automated insertion tool for cochlear implants with integrated force sensing capability. Int J Comput Assist Radiol Surg 9(3):481\u2013494","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"5","key":"2243_CR21","doi-asserted-by":"publisher","first-page":"290","DOI":"10.1159\/000338406","volume":"17","author":"Y Nguyen","year":"2012","unstructured":"Nguyen Y, Miroir M, Kazmitcheff G, Sutter J, Bensidhoum M, Ferrary E, Sterkers O, Bozorg Grayeli A (2012) Cochlear implant insertion forces in microdissected human cochlea to evaluate a prototype array. Audiol Neurotol 17(5):290\u2013298","journal-title":"Audiol Neurotol"},{"issue":"2","key":"2243_CR22","doi-asserted-by":"publisher","first-page":"168","DOI":"10.1097\/MAO.0000000000001648","volume":"39","author":"R Torres","year":"2018","unstructured":"Torres R, Drouillard M, De Seta D, Bensimon JL, Ferrary E, Sterkers O, Bernardeschi D, Nguyen Y (2018) Cochlear implant insertion axis into the basal turn: a critical factor in electrode array translocation. Otol Neurotol 39(2):168\u2013176","journal-title":"Otol Neurotol"},{"key":"2243_CR23","doi-asserted-by":"crossref","unstructured":"Pile J, Wanna GB, Simaan N (2014) Force-based flexible path plans for robotic electrode insertion. In: 2014 IEEE international conference on robotics automation (ICRA), 31 May\u20137 June, Hong Kong, China","DOI":"10.1109\/ICRA.2014.6906625"},{"issue":"2","key":"2243_CR24","doi-asserted-by":"publisher","first-page":"173","DOI":"10.1007\/s11548-009-0299-9","volume":"5","author":"TS Rau","year":"2010","unstructured":"Rau TS, Hussong A, Leinung M, Lenarz T, Majdani O (2010) Automated insertion of preformed cochlear implant electrodes: evaluation of curling behaviour and insertion forces on an artificial cochlear model. Int J Comput Assist Radiol Surg 5(2):173\u2013181","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"8","key":"2243_CR25","doi-asserted-by":"publisher","first-page":"1207","DOI":"10.1097\/MAO.0b013e3181f2ebc3","volume":"31","author":"D Schurzig","year":"2010","unstructured":"Schurzig D, Webster RJ, Dietrich MS, Labadie RF (2010) Force of cochlear implant electrode insertion performed by a robotic insertion tool: comparison of traditional versus advance off-stylet techniques. Otol Neurotol 31(8):1207\u20131210","journal-title":"Otol Neurotol"},{"key":"2243_CR26","first-page":"1","volume":"1344","author":"D De Seta","year":"2016","unstructured":"De Seta D, Torres R, Russo FY, Ferrary E, Kazmitcheff G, Heymann D, Amiaud J, Sterkers O, Bernardeschi D, Nguyen Y (2016) Damage to inner ear structure during cochlear implantation: correlation between insertion force and radio-histological findings in temporal bone specimens. Hear. Res. 1344:1\u20138","journal-title":"Hear. Res."},{"key":"2243_CR27","doi-asserted-by":"publisher","first-page":"e168","DOI":"10.1097\/AUD.0000000000000394","volume":"38","author":"E Avci","year":"2016","unstructured":"Avci E, Nauwelaers T, Hamacher V, Kral A (2016) Three-dimensional force profile during cochlear implantation depends on individual geometry and insertion trauma. Ear Hear 38:e168\u2013e179","journal-title":"Ear Hear"},{"issue":"3","key":"2243_CR28","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1097\/MAO.0b013e31820e75d9","volume":"32","author":"S Helbig","year":"2011","unstructured":"Helbig S, Settevendemie C, MacK M, Baumann U, Helbig M, St\u00f6ver T (2011) Evaluation of an electrode prototype for atraumatic cochlear implantation in hearing preservation candidates: preliminary results from a temporal bone study. Otol Neurotol 32(3):419\u2013423","journal-title":"Otol Neurotol"},{"issue":"1","key":"2243_CR29","doi-asserted-by":"publisher","first-page":"30","DOI":"10.1159\/000442041","volume":"21","author":"I Todt","year":"2016","unstructured":"Todt I, Ernst A, Mittmann P (2016) Effects of different insertion techniques of a cochlear implant electrode on the intracochlear pressure. Audiol Neurotol 21(1):30\u201337","journal-title":"Audiol Neurotol"},{"issue":"1","key":"2243_CR30","doi-asserted-by":"publisher","first-page":"31","DOI":"10.3109\/00016480902998281","volume":"130","author":"O Majdani","year":"2010","unstructured":"Majdani O, Schurzig D, Hussong A, Rau TS, Wittkopf J, Lenarz T, Labadie RF (2010) Force measurement of insertion of cochlear implant electrode arrays in vitro: comparison of surgeon to automated insertion tool. Acta Otolaryngol 130(1):31\u201336","journal-title":"Acta Otolaryngol"},{"key":"2243_CR31","doi-asserted-by":"publisher","DOI":"10.1007\/s00405-020-06070-z","volume-title":"Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report","author":"S Vittoria","year":"2020","unstructured":"Vittoria S, Lahlou G, Torres R, Daoudi H, Mosnier I, Mazalaigue S, Ferrary E, Nguyen Y, Sterkers O (2020) Robot-based assistance in middle ear surgery and cochlear implantation: first clinical report. Arch Oto Rhino Laryngol, Eur. https:\/\/doi.org\/10.1007\/s00405-020-06070-z"},{"issue":"5","key":"2243_CR32","doi-asserted-by":"publisher","first-page":"1191","DOI":"10.1007\/s13346-018-0539-z","volume":"8","author":"NK Prenzler","year":"2018","unstructured":"Prenzler NK, Salcher R, Timm M, Gaertner L, Lenarz T, Warnecke A (2018) Intracochlear administration of steroids with a catheter during human cochlear implantation: a safety and feasibility study. Drug Deliv Transl Res 8(5):1191\u20131199","journal-title":"Drug Deliv Transl Res"},{"issue":"2","key":"2243_CR33","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1007\/s11548-009-0368-0","volume":"5","author":"A Hussong","year":"2010","unstructured":"Hussong A, Rau TS, Ortmaier T, Heimann B, Lenarz T, Majdani O (2010) An automated insertion tool for cochlear implants: another step towards atraumatic cochlear implant surgery. Int J Comput Assist Radiol Surg 5(2):163\u2013171","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2243_CR34","unstructured":"Salcher RB, Nullmeier M, Cramer J, Pawsey N, Lenarz T, Rau TS (2019) Artificial cochlea model material validation for insertion force measurements. In: Conference on implant abutments prostheses (CIAP), July 14\u201319, Lake Tahoe, CA, US"},{"key":"2243_CR35","unstructured":"Rau TS, Nullmeier M, Cramer J, H\u00fcgl S, Pawsey N, Lenarz T, Salcher RB (2019) A method for building individualized two-dimensional artificial cochlea models. Proc Assoc Res Otolaryngol 4236"},{"key":"2243_CR36","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1155\/2015\/574209","volume":"574209","author":"JP Kobler","year":"2015","unstructured":"Kobler JP, Dhanasingh A, Kiran R, Jolly C, Ortmaier T (2015) Cochlear dummy electrodes for insertion training and research purposes: fabrication, mechanical characterization, and experimental validation. Biomed Res. Int. 574209:1\u20139","journal-title":"Biomed Res. Int."},{"issue":"7","key":"2243_CR37","doi-asserted-by":"publisher","first-page":"1237","DOI":"10.1097\/00005537-200407000-00018","volume":"114","author":"O Adunka","year":"2004","unstructured":"Adunka O, Kiefer J, Unkelbach MH, Lehnert T, Gstoettner W (2004) Development and evaluation of an improved cochlear implant electrode design for electric acoustic stimulation. Laryngoscope 114(7):1237\u20131241","journal-title":"Laryngoscope"},{"issue":"4","key":"2243_CR38","doi-asserted-by":"publisher","first-page":"244","DOI":"10.1159\/000445736","volume":"21","author":"LB Kratchman","year":"2016","unstructured":"Kratchman LB, Schuster D, Dietrich MS, Labadie RF (2016) Force perception thresholds in cochlear implantation surgery. Audiol Neurotol 21(4):244\u2013249","journal-title":"Audiol Neurotol"},{"issue":"6","key":"2243_CR39","doi-asserted-by":"publisher","first-page":"882","DOI":"10.1097\/00129492-200311000-00010","volume":"24","author":"AJ Fishman","year":"2003","unstructured":"Fishman AJ, Roland JT, Alexiades G, Mierzwinski J, Cohen NL (2003) Fluoroscopically assisted cochlear implantation. Otol Neurotol 24(6):882\u2013886","journal-title":"Otol Neurotol"},{"key":"2243_CR40","first-page":"1","volume":"23","author":"S Haumann","year":"2019","unstructured":"Haumann S, Imsiecke M, Bauernfeind G, B\u00fcchner A, Helmstaedter V, Lenarz T, Salcher RB (2019) Monitoring of the inner ear function during and after cochlear implant insertion using electrocochleography. Trends Hear 23:1\u201318","journal-title":"Trends Hear"},{"issue":"8","key":"2243_CR41","doi-asserted-by":"publisher","first-page":"2009","DOI":"10.1007\/s00405-015-3763-x","volume":"273","author":"R Torres","year":"2016","unstructured":"Torres R, Kazmitcheff G, Bernardeschi D, De Seta D, Bensimon JL, Ferrary E, Sterkers O, Nguyen Y (2016) Variability of the mental representation of the cochlear anatomy during cochlear implantation. Eur Arch Oto Rhino Laryngol 273(8):2009\u20132018","journal-title":"Eur Arch Oto Rhino Laryngol"},{"key":"2243_CR42","doi-asserted-by":"publisher","first-page":"329","DOI":"10.1007\/s00106-004-1057-5","volume":"53","author":"J Schipper","year":"2004","unstructured":"Schipper J, Aschendorff A, Arapakis I, Ridder GJ, Laszig R (2004) Does navigation-controlled cochleostomy improve the results of cochlear implant surgery? (in German). HNO 53:329\u2013335","journal-title":"HNO"},{"issue":"4","key":"2243_CR43","doi-asserted-by":"publisher","first-page":"l4916","DOI":"10.1126\/scirobotics.aal4916","volume":"2","author":"S Weber","year":"2017","unstructured":"Weber S, Gavaghan K, Wimmer W, Williamson T, Gerber N, Anso J, Bell B, Feldmann A, Rathgeb C, Matulic M, Stebinger M, Schneider D, Mantokoudis G, Scheidegger O, Wagner F, Kompis M, Caversaccio M (2017) Instrument flight to the inner ear. Sci Robot 2(4):l4916","journal-title":"Sci Robot"},{"issue":"1","key":"2243_CR44","doi-asserted-by":"publisher","first-page":"94","DOI":"10.1097\/MAO.0b013e3181c2f81a","volume":"31","author":"R Labadie","year":"2010","unstructured":"Labadie R, Balachandran R (2010) Clinical validation study of percutaneous cochlear access using patient customized micro-stereotactic frames. Otol Neurotol 31(1):94\u201399","journal-title":"Otol Neurotol"},{"key":"2243_CR45","first-page":"10135","volume-title":"Micro-stereotactic frame utilizing bone cement for individual fabrication: an initial investigation of its accuracy","author":"TS Rau","year":"2017","unstructured":"Rau TS, Lexow GJ, Blume D, Kluge M, Lenarz T, Majdania O (2017) Micro-stereotactic frame utilizing bone cement for individual fabrication: an initial investigation of its accuracy. SPIE, Prog Biomed Opt Imaging Proc, p 10135"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02243-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02243-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02243-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,27]],"date-time":"2021-08-27T23:31:47Z","timestamp":1630107107000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02243-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,8,28]]},"references-count":45,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["2243"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02243-7","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,8,28]]},"assertion":[{"value":"10 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 August 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interests.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}}]}}