{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T14:05:09Z","timestamp":1777989909168,"version":"3.51.4"},"reference-count":26,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T00:00:00Z","timestamp":1598918400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T00:00:00Z","timestamp":1598918400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100003032","name":"Association Nationale de la Recherche et de la Technologie","doi-asserted-by":"publisher","award":["2017\/1639"],"award-info":[{"award-number":["2017\/1639"]}],"id":[{"id":"10.13039\/501100003032","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2020,11]]},"DOI":"10.1007\/s11548-020-02250-8","type":"journal-article","created":{"date-parts":[[2020,9,1]],"date-time":"2020-09-01T15:03:48Z","timestamp":1598972628000},"page":"1881-1894","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":4,"title":["Catheter navigation support for liver radioembolization guidance: feasibility of structure-driven intensity-based registration"],"prefix":"10.1007","volume":"15","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7642-9124","authenticated-orcid":false,"given":"Houda","family":"Hammami","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6754-9298","authenticated-orcid":false,"given":"Florent","family":"Lalys","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Rolland","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5444-7970","authenticated-orcid":false,"given":"Antoine","family":"Petit","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3451-8193","authenticated-orcid":false,"given":"Pascal","family":"Haigron","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,9,1]]},"reference":[{"key":"2250_CR1","unstructured":"World Health Organization. https:\/\/www.who.int\/news-room\/fact-sheets\/detail\/cancer"},{"key":"2250_CR2","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1186\/s13550-019-0485-x","volume":"9","author":"E Jafargholi Rangraz","year":"2019","unstructured":"Jafargholi Rangraz E, Coudyzer W, Maleux G, Baete K, Deroose CM, Nuyts J (2019) Multi-modal image analysis for semi-automatic segmentation of the total liver and liver arterial perfusion territories for radioembolization. EJNMMI Res 9:19","journal-title":"EJNMMI Res"},{"issue":"2","key":"2250_CR3","doi-asserted-by":"publisher","first-page":"215","DOI":"10.1007\/s11548-018-1877-5","volume":"14","author":"N Spahr","year":"2019","unstructured":"Spahr N, Thoduka S, Abolmaali N, Kikinis R, Schenk A (2019) Multimodal image registration for liver radioembolization planning and patient assessment. Int J Comput Assist Radiol Surg 14(2):215\u2013225","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"2250_CR4","doi-asserted-by":"publisher","first-page":"339","DOI":"10.2967\/jnumed.114.145177","volume":"56","author":"E Garin","year":"2015","unstructured":"Garin E, Rolland Y, Edeline J, Icard N, Lenoir L, Laffont S, Mesbah H, Breton M, Sulpice L, Boudjema K, Rohou T, Raoul JL, Cl\u00e9ment B, Boucher E (2015) Personalized dosimetry and intensification concept with 90Y-loaded glass microsphere radioembolization induce prolonged overall survival in hepatocellular carcinoma patients with portal vein thrombosis. J Nucl Med 56(3):339\u2013346","journal-title":"J Nucl Med"},{"key":"2250_CR5","doi-asserted-by":"publisher","DOI":"10.20517\/2394-5079.2019.28","author":"S Puppala","year":"2019","unstructured":"Puppala S (2019) Technical update on transcatheter arterial chemoembolization. Hepatoma Res. https:\/\/doi.org\/10.20517\/2394-5079.2019.28","journal-title":"Hepatoma Res"},{"issue":"5","key":"2250_CR6","doi-asserted-by":"publisher","first-page":"291","DOI":"10.3109\/10929080209146038","volume":"7","author":"MA Clifford","year":"2002","unstructured":"Clifford MA, Banovac F, Levy E, Cleary K (2002) Assessment of hepatic motion secondary to respiration for computer assisted interventions. Comput Aided Surg Off J Int Soc Comput Aided Surg 7(5):291\u2013299","journal-title":"Comput Aided Surg Off J Int Soc Comput Aided Surg"},{"key":"2250_CR7","doi-asserted-by":"crossref","unstructured":"Venkatraman V, Horn MHV, Weeks S, Bullitt E (2004) Liver motion due to needle pressure, cardiac, and respiratory motion during the TIPS procedure. In: Medical Image Computing and Computer-Assisted Intervention\u2014MICCAI 2004, pp 66\u201372","DOI":"10.1007\/978-3-540-30136-3_9"},{"key":"2250_CR8","doi-asserted-by":"crossref","unstructured":"Blackall JM, King AP, Penney GP, Adam A, Hawkes DJ (2001) A statistical model of respiratory motion and deformation of the liver. In: Medical Image Computing and Computer-Assisted Intervention\u2014MICCAI 2001. Springer, Berlin, pp 1338\u20131340","DOI":"10.1007\/3-540-45468-3_219"},{"issue":"3","key":"2250_CR9","doi-asserted-by":"publisher","first-page":"427","DOI":"10.1118\/1.1644513","volume":"31","author":"T Rohlfing","year":"2004","unstructured":"Rohlfing T, Maurer CR, O\u2019Dell WG, Zhong J (2004) Modeling liver motion and deformation during the respiratory cycle using intensity-based nonrigid registration of gated MR images. Med Phys 31(3):427\u2013432","journal-title":"Med Phys"},{"issue":"9","key":"2250_CR10","doi-asserted-by":"publisher","first-page":"1357","DOI":"10.1007\/s11548-015-1218-x","volume":"10","author":"P Ambrosini","year":"2015","unstructured":"Ambrosini P, Ruijters D, Niessen WJ, Moelker A, van Walsum T (2015) Continuous roadmapping in liver TACE procedures using 2D\u20133D catheter-based registration. Int J Comput Assist Radiol Surg 10(9):1357\u20131370","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"2250_CR11","doi-asserted-by":"publisher","first-page":"757","DOI":"10.1109\/TMI.2016.2625811","volume":"36","author":"P Ambrosini","year":"2017","unstructured":"Ambrosini P, Smal I, Ruijters D, Niessen WJ, Moelker A, Van Walsum T (2017) A hidden Markov model for 3D Catheter Tip Tracking With 2D X-ray catheterization sequence and 3D rotational angiography. IEEE Trans Med Imaging 36(3):757\u2013768","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"2250_CR12","doi-asserted-by":"publisher","first-page":"526","DOI":"10.1007\/s00270-012-0495-9","volume":"36","author":"I Bargellini","year":"2013","unstructured":"Bargellini I, Turini F, Bozzi E, Lauretti D, Cicorelli A, Lunardi A, Cioni R, Bartolozzi C (2013) Image fusion of preprocedural CTA with real-time fluoroscopy to guide proper hepatic artery catheterization during transarterial chemoembolization of hepatocellular carcinoma: a feasibility study. Cardiovasc Intervent Radiol 36(2):526\u2013530","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"6","key":"2250_CR13","doi-asserted-by":"publisher","first-page":"805","DOI":"10.1007\/s11548-018-1755-1","volume":"13","author":"JG Guevara","year":"2018","unstructured":"Guevara JG, Peterlik I, Berger M-O, Cotin S (2018) Biomechanics-based graph matching for augmented CT-CBCT. Int J Comput Assist Radiol Surg 13(6):805\u2013813","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"7","key":"2250_CR14","doi-asserted-by":"publisher","first-page":"912","DOI":"10.1016\/j.avsg.2010.03.018","volume":"24","author":"A Kaladji","year":"2010","unstructured":"Kaladji A, Lucas A, Kervio G, Haigron P, Cardon A (2010) Sizing for endovascular aneurysm repair: clinical evaluation of a new automated three-dimensional software. Ann Vasc Surg 24(7):912\u2013920","journal-title":"Ann Vasc Surg"},{"issue":"9","key":"2250_CR15","doi-asserted-by":"publisher","first-page":"1713","DOI":"10.1007\/s11548-016-1416-1","volume":"11","author":"A Dum\u00e9nil","year":"2016","unstructured":"Dum\u00e9nil A, Kaladji A, Castro M, G\u00f6ksu C, Lucas A, Haigron P (2016) A versatile intensity-based 3D\/2D rigid registration compatible with mobile C-arm for endovascular treatment of abdominal aortic aneurysm. Int J Comput Assist Radiol Surg 11(9):1713\u20131729","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2250_CR16","unstructured":"Kim K, Park S, Hong H, Shin YG (2005) Fast 2D\u20133D registration using GPU-based preprocessing. In: Proceedings of 7th international workshop on enterprise networking and computing in healthcare industry, 2005. HEALTHCOM 2005, pp 139\u2013143"},{"key":"2250_CR17","doi-asserted-by":"crossref","unstructured":"Kubias A, Deinzer F, Feldmann T, Paulus D (2007) Extended global optimization strategy for rigid 2D\/3D image registration. In: Computer analysis of images and patterns, Berlin, pp 759\u201376794","DOI":"10.1007\/978-3-540-74272-2_94"},{"issue":"6","key":"2250_CR18","first-page":"905","volume":"22","author":"AM Sailer","year":"2015","unstructured":"Sailer AM, Wagemans BA, Das M, de Haan MW, Nelemans PJ, Wildberger JE, Schurink GW (2015) Quantification of respiratory movement of the aorta and side branches. J Endovasc Ther Off J Int Soc Endovasc Spec 22(6):905\u2013911","journal-title":"J Endovasc Ther Off J Int Soc Endovasc Spec"},{"key":"2250_CR19","unstructured":"Raheem A, Carrell T, Modarai B, Penney G (2010) Non-rigid 2D\u20133D image registration for use in endovascular repair of abdominal aortic aneurysms. Presented at the Medical Image Understanding and Analysis, pp 153\u2013157"},{"key":"2250_CR20","doi-asserted-by":"crossref","unstructured":"Penney GP, Weese J, Little JA, Desmedt P, Hill DLG, Hawkes DJ (1998) A comparison of similarity measures for use in 2D\u20133D medical image registration. In: Wells WM, Colchester A, Delp S (eds) Medical Image Computing and Computer-Assisted Intervention\u2014MICCAI\u201998. Springer, Berlin, pp 1153\u20131161","DOI":"10.1007\/BFb0056305"},{"issue":"7","key":"2250_CR21","doi-asserted-by":"publisher","first-page":"997","DOI":"10.1007\/s11548-018-1731-9","volume":"13","author":"F Lalys","year":"2018","unstructured":"Lalys F, Favre K, Villena A, Durrmann V, Colleaux M, Lucas A, Kaladji A (2018) A hybrid image fusion system for endovascular interventions of peripheral artery disease. Int J Comput Assist Radiol Surg 13(7):997\u20131007","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"2250_CR22","doi-asserted-by":"publisher","first-page":"70","DOI":"10.1053\/j.tvir.2019.02.006","volume":"22","author":"E Wehrenberg-Klee","year":"2019","unstructured":"Wehrenberg-Klee E, Gandhi RT, Ganguli S (2019) Patient selection and clinical outcomes of Y90 in hepatocellular carcinoma. Tech Vasc Interv Radiol 22(2):70\u201373","journal-title":"Tech Vasc Interv Radiol"},{"key":"2250_CR23","doi-asserted-by":"publisher","DOI":"10.2967\/jnumed.112.117614","author":"M Wondergem","year":"2013","unstructured":"Wondergem M, Smits ML, Elschot M, de Jong HW, Verkooijen HM, van den Bosch MA, Nijsen JF, Lam MG (2013) 99\u00a0mTc-macroaggregated albumin poorly predicts the intrahepatic distribution of\u00a090Y resin microspheres in hepatic radioembolization. J Nucl Med. https:\/\/doi.org\/10.2967\/jnumed.112.117614","journal-title":"J Nucl Med"},{"issue":"1","key":"2250_CR24","doi-asserted-by":"publisher","first-page":"62","DOI":"10.1186\/s13550-019-0533-6","volume":"9","author":"M Kafrouni","year":"2019","unstructured":"Kafrouni M, Allimant C, Fourcade M, Vauclin S, Guiu B, Mariano-Goulart D, Bouall\u00e8gue FB (2019) Analysis of differences between 99mTc-MAA SPECT- and 90Y-microsphere PET-based dosimetry for hepatocellular carcinoma selective internal radiation therapy. EJNMMI Res 9(1):62","journal-title":"EJNMMI Res"},{"issue":"3","key":"2250_CR25","doi-asserted-by":"publisher","first-page":"253","DOI":"10.1177\/153303461000900304","volume":"9","author":"K Knesaurek","year":"2010","unstructured":"Knesaurek K, Machac J, Muzinic M, DaCosta M, Zhang Z, Heiba S (2010) Quantitative comparison of yttrium-90 (90Y)-microspheres and technetium-99m (99mTc)-macroaggregated albumin SPECT images for planning 90Y therapy of liver cancer. Technol Cancer Res Treat 9(3):253\u2013262","journal-title":"Technol Cancer Res Treat"},{"issue":"2","key":"2250_CR26","doi-asserted-by":"publisher","first-page":"387","DOI":"10.1109\/TMI.2012.2227337","volume":"32","author":"A Varnavas","year":"2013","unstructured":"Varnavas A, Carrell T, Penney G (2013) Increasing the automation of a 2D-3D registration system. IEEE Trans Med Imaging 32(2):387\u2013399","journal-title":"IEEE Trans Med Imaging"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02250-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02250-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02250-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,9,1]],"date-time":"2021-09-01T01:08:46Z","timestamp":1630458526000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02250-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,9,1]]},"references-count":26,"journal-issue":{"issue":"11","published-print":{"date-parts":[[2020,11]]}},"alternative-id":["2250"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02250-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,9,1]]},"assertion":[{"value":"31 March 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"16 August 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 September 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This was an observational study for which anonymous retrospective data were used. It was performed in accordance with the ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all individual patients included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}},{"value":"Informed consent was obtained from all patients for whom data are included in this article.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent for publication"}},{"value":"The data that support the findings of this study are available from the corresponding author, H.H, upon reasonable request.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Availability of data and materials"}}]}}