{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T15:52:05Z","timestamp":1786981925027,"version":"build-2736575974"},"reference-count":27,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,10,22]],"date-time":"2020-10-22T00:00:00Z","timestamp":1603324800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,10,22]],"date-time":"2020-10-22T00:00:00Z","timestamp":1603324800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100003399","name":"Science and Technology Commission of Shanghai Municipality","doi-asserted-by":"publisher","award":["18441900500"],"award-info":[{"award-number":["18441900500"]}],"id":[{"id":"10.13039\/501100003399","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1007\/s11548-020-02278-w","type":"journal-article","created":{"date-parts":[[2020,10,21]],"date-time":"2020-10-21T21:02:35Z","timestamp":1603314155000},"page":"179-192","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Force feedback controls of multi-gripper robotic endovascular intervention: design, prototype, and experiments"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-3969-5148","authenticated-orcid":false,"given":"Kundong","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jianyun","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Weiwu","family":"Yan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qingsheng","family":"Lu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shengdong","family":"Nie","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2020,10,22]]},"reference":[{"key":"2278_CR1","doi-asserted-by":"publisher","first-page":"493","DOI":"10.1016\/j.jvs.2010.06.154","volume":"52","author":"G Antoniou","year":"2011","unstructured":"Antoniou G, Riga CV, Mayer EK, Cheshire NW, Bicknell CD (2011) Clinical applications of robotic technology in vascular and endovascular surgery. J Vasc Surg 52:493\u2013499","journal-title":"J Vasc Surg"},{"key":"2278_CR2","doi-asserted-by":"publisher","first-page":"697","DOI":"10.1007\/s10439-013-0946-8","volume":"42","author":"H Rafii-Tari","year":"2013","unstructured":"Rafii-Tari H, Payne CJ, Yang GZ (2013) Current and emerging robot-assisted endovascular catheterization technologies: a review. Ann Biomed Eng 42:697\u2013715","journal-title":"Ann Biomed Eng"},{"key":"2278_CR3","doi-asserted-by":"publisher","first-page":"26","DOI":"10.1111\/j.1540-8167.2007.00708.x","volume":"18","author":"MP Armacost","year":"2007","unstructured":"Armacost MP, Adair J, Munger T (2007) Accurate and reproducible target navigation with the stereotaxis Niobe magnetic navigation system. Cardiovasc Electrophysiol 18:26\u201331","journal-title":"Cardiovasc Electrophysiol"},{"key":"2278_CR4","doi-asserted-by":"publisher","first-page":"44","DOI":"10.1109\/100.540149","volume":"3","author":"D Paolo","year":"1996","unstructured":"Paolo D, Eugenio G (1996) Robotics for medical applications. IEEE Robot Autom Mag 3:44\u201356","journal-title":"IEEE Robot Autom Mag"},{"key":"2278_CR5","doi-asserted-by":"publisher","first-page":"460","DOI":"10.1016\/j.jcin.2010.12.007","volume":"4","author":"JF Granada","year":"2011","unstructured":"Granada JF, Delgado JA, Uribe MP, Fernandez A, Blanco G, Leon MB (2011) First-in-human evaluation of a novel robotic-assisted coronary angioplasty system. JACC Cardiovasc Interv 4:460\u2013465","journal-title":"JACC Cardiovasc Interv"},{"key":"2278_CR6","doi-asserted-by":"publisher","first-page":"1901","DOI":"10.1109\/TBME.2009.2017203","volume":"56","author":"T Yogesh","year":"2009","unstructured":"Yogesh T, Jeffrey SB, Holdsworth WD, Drangova M (2009) Design and performance evaluation of a remote catheter navigation system. IEEE Trans Biomed Eng 56:1901\u20131908","journal-title":"IEEE Trans Biomed Eng"},{"key":"2278_CR7","doi-asserted-by":"publisher","first-page":"2140","DOI":"10.1109\/TBME.2008.921148","volume":"56","author":"Y Thakur","year":"2009","unstructured":"Thakur Y, Holdsworth WD, Drangova M (2009) Characterization of catheter dynamics during percutaneous transluminal catheter procedures. IEEE Trans Biomed Eng 56:2140\u20132143","journal-title":"IEEE Trans Biomed Eng"},{"key":"2278_CR8","doi-asserted-by":"publisher","first-page":"1034","DOI":"10.1111\/j.1525-1594.2010.01142.x","volume":"34","author":"JW Park","year":"2010","unstructured":"Park JW, Choi J, Park HN, Song SJ, Lee JC, Park Y, Shin SM, Sun K (2010) Development of a force-reflecting robotic platform for cardiac catheter navigation. Artif Organs 34:1034\u20131039","journal-title":"Artif Organs"},{"key":"2278_CR9","doi-asserted-by":"publisher","first-page":"132","DOI":"10.1002\/rcs.1650","volume":"12","author":"WS Lu","year":"2016","unstructured":"Lu WS, Xu W, Pan F, Liu D, Tian ZM, Zeng Y (2016) Clinical application of a vascular interventional robot in cerebral angiography. Int J Med Robot Comput Assist Surg 12:132\u2013136","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"2278_CR10","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.sna.2004.04.057","volume":"115","author":"J Peirs","year":"2004","unstructured":"Peirs J, Clijnena J, Reynaertsa D, Brussel HV, Herijgers P, Corteville B, Boone S (2004) A micro optical force sensor for force feedback during minimally invasive robotic surgery. Sens Actuators A Phys 115:447\u2013455","journal-title":"Sens Actuators A Phys"},{"key":"2278_CR11","doi-asserted-by":"publisher","first-page":"76","DOI":"10.1007\/s10544-016-0100-0","volume":"18","author":"J Guo","year":"2016","unstructured":"Guo J, Guo SX, Yu Y (2016) Design and characteristics evaluation of a novel teleoperated robotic catheterization system with force feedback for vascular interventional surgery. Biomed Microdevices 18:76\u201392","journal-title":"Biomed Microdevices"},{"key":"2278_CR12","unstructured":"Guo J, Guo SX, Wang P, Wei W, Wang Y (2013) A novel type of catheter sidewall tactile sensor array for vascular interventional surgery. In: 2013 ICME international conference on complex medical engineering. pp 264\u2013267"},{"key":"2278_CR13","doi-asserted-by":"publisher","first-page":"1361","DOI":"10.1007\/s11548-015-1324-9","volume":"11","author":"Z Hu","year":"2016","unstructured":"Hu Z, Yoon CH, Park SB, Jo YH (2016) Design of a haptic device with grasp and push\u2013pull force feedback for a master\u2013slave surgical robot. Int J CARS 11:1361\u20131369","journal-title":"Int J CARS"},{"key":"2278_CR14","doi-asserted-by":"publisher","first-page":"819","DOI":"10.1007\/s11548-012-0807-1","volume":"8","author":"T Yoneyama","year":"2013","unstructured":"Yoneyama T, Watanabe T, Kagawa H, Hamada J, Hayashi Y, Nakada M (2013) Force-detecting gripper and force feedback system for neurosurgery applications. Int J CARS 8:819\u2013829","journal-title":"Int J CARS"},{"key":"2278_CR15","doi-asserted-by":"crossref","first-page":"160","DOI":"10.1002\/rcs.301","volume":"6","author":"G Srimathveeravalli","year":"2010","unstructured":"Srimathveeravalli G, Kesavadas T, Li X (2010) Design and fabrication of a robotic mechanism for remote steering and positioning of interventional devices. Int J Med Robot Comput Assist Surg 6:160\u2013170","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"2278_CR16","doi-asserted-by":"crossref","unstructured":"Payne CJ, Ra-Tari H, Yang GZ (2012) A force feedback system for endovascular catheterization. In: 2012 IEEE\/RSJ international conference on intelligent robotics and systems. pp 1298\u20131304","DOI":"10.1109\/IROS.2012.6386149"},{"key":"2278_CR17","doi-asserted-by":"publisher","first-page":"1045","DOI":"10.1109\/TRO.2011.2160467","volume":"27","author":"SB Kesner","year":"2011","unstructured":"Kesner SB, Howe RD (2011) Position control of motion compensation cardiac catheters. IEEE Trans Robot 27:1045\u20131055","journal-title":"IEEE Trans Robot"},{"key":"2278_CR18","doi-asserted-by":"crossref","unstructured":"Kesner SB, Howe RD (2011) Force control of flexible catheter robots for beating heart surgery. In: Proceedings of the 2011 IEEE international conference on robotics and automation. IEEE, Shanghai, China, pp 1589\u20131594","DOI":"10.1109\/ICRA.2011.5979690"},{"key":"2278_CR19","doi-asserted-by":"crossref","unstructured":"Razban M, Dargahi J, Boulet B (2018) A sensor-less catheter contact force estimation approach in endovascular intervention procedures. In: 2018 IEEE\/RSJ international conference on intelligent robotics and systems. pp 2100\u20132106","DOI":"10.1109\/IROS.2018.8593387"},{"key":"2278_CR20","doi-asserted-by":"crossref","unstructured":"Zhang L, Guo SX, Yu H, Song Y, Song D (2018) Rotary encoder-based position transmission and feedback of a novel robotic catheter system for endovascular catheterization. In: 2018 IEEE international conference on information and automation. pp 32\u201336","DOI":"10.1109\/ICInfA.2018.8812539"},{"key":"2278_CR21","doi-asserted-by":"crossref","unstructured":"Dagnino G, Liu J, Abdelaziz ME, Chi W, Riga C, Yang GZ (2018) Haptic feedback and dynamic active constraints for robot assisted endovascular catheterization. In: 2018 IEEE\/RSJ international conference on intelligent robotics and systems. pp 1770\u20131775","DOI":"10.1109\/IROS.2018.8593628"},{"key":"2278_CR22","first-page":"53","volume":"14","author":"TM Patel","year":"2019","unstructured":"Patel TM, Shah SC, Pancholy SB (2019) Long distance tele-robotic assisted percutaneous coronary intervention: a report of first-in-human experience. E Clin Med 14:53\u201358","journal-title":"E Clin Med"},{"key":"2278_CR23","doi-asserted-by":"crossref","unstructured":"Molinero MB, Dagnino G, Liu J, Chi W (2019) Haptic guidance for robot-assisted endovascular procedures: implementation and evaluation on surgical simulator. In: 2019 international conference on intelligent robotics and systems. pp 5398\u20135403","DOI":"10.1109\/IROS40897.2019.8967712"},{"key":"2278_CR24","doi-asserted-by":"publisher","first-page":"e617","DOI":"10.1016\/j.wneu.2019.03.221","volume":"127","author":"M Shigeru","year":"2019","unstructured":"Shigeru M, Yoshitaka N, Takahide H (2019) Support robot with sensory-motor feedback system for neuro-endovascular novel operation intervention. World Neurosurg 127:e617\u2013e623","journal-title":"World Neurosurg"},{"key":"2278_CR25","unstructured":"Robocath (2020) Robocath successfully completes first robotic coronary angioplasties in Germany with R-One\u2122. https:\/\/www.robocath.com\/product\/. Accessed 21 Jan 2020"},{"key":"2278_CR26","first-page":"545","volume":"24","author":"L Liu","year":"2014","unstructured":"Liu L, Cao L, Liu D, Wang D, Cao XD (2014) Achieving for force feedback in master\u2013slave vascular intervention systems. High Technol Lett 24:545\u2013550","journal-title":"High Technol Lett"},{"key":"2278_CR27","first-page":"1","volume":"6","author":"CD He","year":"2000","unstructured":"He CD, Sen W, Zhang HF (2000) Study on reaction time and movement time of fingers. Ergonomics 6:1\u20135","journal-title":"Ergonomics"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02278-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-020-02278-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02278-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,10,10]],"date-time":"2023-10-10T04:55:42Z","timestamp":1696913742000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-020-02278-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,10,22]]},"references-count":27,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["2278"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02278-w","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,10,22]]},"assertion":[{"value":"28 May 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}