{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,15]],"date-time":"2026-05-15T05:31:45Z","timestamp":1778823105453,"version":"3.51.4"},"reference-count":33,"publisher":"Springer Science and Business Media LLC","issue":"1","license":[{"start":{"date-parts":[[2020,11,4]],"date-time":"2020-11-04T00:00:00Z","timestamp":1604448000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2020,11,4]],"date-time":"2020-11-04T00:00:00Z","timestamp":1604448000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"name":"Collaborative Health Research Project (CHRP): Natural Sciences and Engineering Research Council of Canada (NSERC) and Canadian Institute of Health Research","award":["214110"],"award-info":[{"award-number":["214110"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,1]]},"DOI":"10.1007\/s11548-020-02280-2","type":"journal-article","created":{"date-parts":[[2020,11,4]],"date-time":"2020-11-04T09:08:38Z","timestamp":1604480918000},"page":"11-22","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["The effect of artificial X-rays on C-arm positioning performance in a simulated orthopaedic surgical setting"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-1491-4597","authenticated-orcid":false,"given":"Mich\u00e8le","family":"Touchette","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Robyn","family":"Newell","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Carolyn","family":"Anglin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Pierre","family":"Guy","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kelly","family":"Lefaivre","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Meena","family":"Amlani","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Antony","family":"Hodgson","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2020,11,4]]},"reference":[{"issue":"2","key":"2280_CR1","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1503\/cjs.015311","volume":"56","author":"E Pally","year":"2013","unstructured":"Pally E, Kreder H (2013) Survey of terminology used for the intraoperative direction of C-arm fluoroscopy. Can J Surg 56(2):109\u2013112","journal-title":"Can J Surg"},{"key":"2280_CR2","doi-asserted-by":"publisher","first-page":"152","DOI":"10.1097\/ACO.0b013e32809f9506","volume":"20","author":"L Booij","year":"2006","unstructured":"Booij L (2006) Conflicts in the operating theatre. Curr Opin Anesthesiol 20:152\u2013156","journal-title":"Curr Opin Anesthesiol"},{"issue":"5","key":"2280_CR3","doi-asserted-by":"publisher","first-page":"316","DOI":"10.1111\/ans.12482","volume":"84","author":"C Yeo","year":"2014","unstructured":"Yeo C, Gordon R, Nusem I (2014) Improving operating theatre communication between the orthopaedics surgeon and radiographer. ANZ J Surg 84(5):316\u2013319","journal-title":"ANZ J Surg"},{"issue":"8","key":"2280_CR4","doi-asserted-by":"publisher","first-page":"1727","DOI":"10.1016\/j.injury.2017.04.041","volume":"48","author":"A Matityahu","year":"2017","unstructured":"Matityahu A, Duffy R, Goldhahn S, Joeris A, Richter P, Gebhard F (2017) The great unknown-a systematic literature review about risk associated with intraoperative imaging during orthopaedic surgeries. Injury 48(8):1727\u20131734","journal-title":"Injury"},{"issue":"10","key":"2280_CR5","doi-asserted-by":"publisher","first-page":"687","DOI":"10.1097\/BOT.0b013e318158fd42","volume":"21","author":"F Matthews","year":"2007","unstructured":"Matthews F, Hoigne D, Weiser M, Wanner G, Regazzoni P, Suhm N, Messmer P (2007) Navigating the fluoroscope\u2019s C-arm back into position: an accurate and practicable solution to cut radiation and optimize intraoperative workflow. J Orthop Trauma 21(10):687\u2013692","journal-title":"J Orthop Trauma"},{"key":"2280_CR6","doi-asserted-by":"publisher","first-page":"399","DOI":"10.1007\/s11548-009-0322-1","volume":"4","author":"O Bott","year":"2009","unstructured":"Bott O, Wagner M, Duwenkamp C, Hellrung N, Dresing K (2009) Improving education on C-arm operation and radiation protection with a computer-based training and simulation system. Int J Comput Assist Radiol Surg 4:399\u2013407","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2280_CR7","first-page":"65","volume":"31","author":"O Bott","year":"2011","unstructured":"Bott O, Dresing K, Wagner M, Raab B, Teistler M (2011) Use of a C-arm fluoroscopy simulator to support training in intraoperative radiography. Radiogr Radiol Soc N Am 31:65\u201376","journal-title":"Radiogr Radiol Soc N Am"},{"key":"2280_CR8","doi-asserted-by":"publisher","first-page":"270","DOI":"10.3414\/ME0476","volume":"47","author":"O Bott","year":"2008","unstructured":"Bott O, Teistler M, Duwenkamp C, Wagner M, Marschollek M, Plischke M, Raab B, St\u00fcrmer K, Pretschner D, Dresing K (2008) virtX: evaluation of a computer-based training system for mobile C-arm systems in trauma and orthopaedics. Methods Inf Med 47:270\u2013278","journal-title":"Methods Inf Med"},{"issue":"1","key":"2280_CR9","doi-asserted-by":"publisher","first-page":"13","DOI":"10.3109\/10929088.2010.542694","volume":"16","author":"M M\u00fcller","year":"2011","unstructured":"M\u00fcller M, Belei P, de la Fuente M, Strake M, Weber O, Burger C, Radermacher K, Wirtz D (2011) Evaluation of a fluoroscopy-based navigation system enabling a virtual radiation-free preview of X-ray images for placement of cannulated hip screws: a cadaver study. Comput Aided Surg 16(1):13\u201322","journal-title":"Comput Aided Surg"},{"key":"2280_CR10","doi-asserted-by":"publisher","first-page":"56","DOI":"10.1007\/978-3-642-13711-2_6","volume":"6135","author":"L Wang","year":"2010","unstructured":"Wang L, Weidert S (2010) First animal cadaver study for interlocking of intramedullary nails under camera augmented mobile C-arm. A surgical workflow based preclinical evaluation. Proc IPCAI Lect Notes Comput Sci 6135:56\u201366","journal-title":"Proc IPCAI Lect Notes Comput Sci"},{"key":"2280_CR11","first-page":"209","volume":"57","author":"M M\u00fcller","year":"2012","unstructured":"M\u00fcller M, Kabir K, Gravius S, de la Fuente M, Belei P, Strake M, Wirtz D (2012) Fluoroscopy-based computer-assisted navigation for implant placement and hip resurfacing arthroplasty in the proximal femur: the zero-dose C-arm navigation approach. Biomed Eng 57:209\u2013219","journal-title":"Biomed Eng"},{"issue":"1","key":"2280_CR12","first-page":"256","volume":"2","author":"M De la Fuente","year":"2007","unstructured":"De la Fuente M, Belei P, Ohnsorge J, Skwara A, Radermacher K (2007) Zero-dose C-arm navigation: an efficient approach based on virtual X-ray targeting. Int J Comput Assist Radiol Surg 2(1):256\u2013272","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2280_CR13","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s11548-012-0682-9","volume":"7","author":"S Reaungamornrat","year":"2012","unstructured":"Reaungamornrat S, Otake Y, Uneri A, Schafer S, Mirota D, Nithiananthan S, Stayman J, Kleinszig G, Khanna A, Taylor R, Siewerdsen J (2012) An on-board surgical tracking and video augmentation system for C-arm image guidance. Int J Comput Assist Radiol Surg 7:647\u2013665","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2280_CR14","first-page":"101352","volume":"10135","author":"T De Silva","year":"2017","unstructured":"De Silva T, Punnoose J, Uneri A, Goerres J, Jacobson M, Ketcha M, Manbachi A, Vogt S, Kleinszig G, Khanna A, Wolinksy J, Osgood G, Siewerdsen J (2017) C-arm positioning using virtual fluoroscopy for image-guided surgery. Proc SPIE Int Soc Opt Eng 10135:101352","journal-title":"Proc SPIE Int Soc Opt Eng"},{"key":"2280_CR15","doi-asserted-by":"publisher","first-page":"762506","DOI":"10.1117\/12.843958","volume":"7625","author":"P Dressel","year":"2010","unstructured":"Dressel P, Wang L, Kutter O, Traub J, Heining S, Navab N (2010) Intraoperative positioning of mobile c-arms using artificial fluoroscopy. Proc SPIE 7625:762506","journal-title":"Proc SPIE"},{"key":"2280_CR16","doi-asserted-by":"publisher","first-page":"903618","DOI":"10.1117\/12.2044112","volume":"9036","author":"R Gong","year":"2014","unstructured":"Gong R, Jenkins B, Sze R, Yaniv Z (2014) A cost effective and high fidelity fluoroscopy simulator using the image-guided surgery toolkit (IGSTK). Proc SPIE 9036:903618","journal-title":"Proc SPIE"},{"key":"2280_CR17","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1007\/s11548-012-0746-x","volume":"8","author":"X Chen","year":"2013","unstructured":"Chen X, Wang L, Fallavollita P, Navab N (2013) Precise X-ray and video overlay for augmented reality fluoroscopy. Int J Comput Assist Radiol Surg 8:29\u201338","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2280_CR18","doi-asserted-by":"publisher","first-page":"473","DOI":"10.1016\/j.ics.2004.03.038","volume":"1268","author":"K Cleary","year":"2004","unstructured":"Cleary K, Ibanez L, Ranjan S, Blake B (2004) IGSTK: a software toolkit for image-guided surgery applications. Int Congr Ser 1268:473\u2013479","journal-title":"Int Congr Ser"},{"issue":"1","key":"2280_CR19","doi-asserted-by":"publisher","first-page":"015005","DOI":"10.1117\/1.JMI.5.1.015005","volume":"5","author":"T De Silva","year":"2018","unstructured":"De Silva T, Punnoose J, Uneri A, Mahesh M, Goerres J, Jacobson M, Ketcha M, Manbachi A, Vogt S, Kleinszig G, Khanna A, Wolinksy J, Siewerdsen J, Osgood G (2018) Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction. J Med Imaging 5(1):015005","journal-title":"J Med Imaging"},{"issue":"5","key":"2280_CR20","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1049\/htl.2018.5066","volume":"5","author":"M Unberath","year":"2018","unstructured":"Unberath M, Fotouhi J, Hajek J, Maier A, Osgood G, Taylor R, Armand M, Navab N (2018) Augmented reality-based feedback for technician-in-the-loop C-arm repositioning. Healthc Technol Lett 5(5):143\u2013147","journal-title":"Healthc Technol Lett"},{"issue":"2","key":"2280_CR21","doi-asserted-by":"publisher","first-page":"252","DOI":"10.1118\/1.595715","volume":"12","author":"R Siddon","year":"1985","unstructured":"Siddon R (1985) Fast calculation of the exact radiological path for a three-dimensional CT array. Med Phys 12(2):252\u2013255","journal-title":"Med Phys"},{"issue":"1","key":"2280_CR22","doi-asserted-by":"publisher","first-page":"55","DOI":"10.1016\/j.ocl.2010.08.004","volume":"42","author":"P Bates","year":"2011","unstructured":"Bates P, Starr A, Reinert C (2011) The percutaneous treatment of pelvic and acetabular fractures. Orthop Clin N Am 42(1):55\u201367","journal-title":"Orthop Clin N Am"},{"issue":"69","key":"2280_CR23","first-page":"1","volume":"93","author":"B Giordano","year":"2011","unstructured":"Giordano B, Grauer J, Miller C, Morgan T, Rechtine G (2011) Radiation exposure issues in orthopaedics. J Bone Jt Surg 93(69):1\u201310","journal-title":"J Bone Jt Surg"},{"key":"2280_CR24","doi-asserted-by":"publisher","first-page":"570","DOI":"10.3171\/SPI.2008.4.08182","volume":"9","author":"R Bindal","year":"2008","unstructured":"Bindal R, Glaze S, Ognoskie M, Tunner V, Malone R, Ghosh S (2008) Surgeon and patient radiation exposure in minimally invasive transforaminal lumbar interbody fusion. J Neurosurg Spine 9:570\u2013573","journal-title":"J Neurosurg Spine"},{"key":"2280_CR25","first-page":"1515","volume":"3","author":"G Han","year":"2000","unstructured":"Han G, Liang Z, You J (2000) A fast ray-tracing technique for TCT and ECT studies. IEEE Nucl Sci Symp 3:1515\u20131518","journal-title":"IEEE Nucl Sci Symp"},{"issue":"1","key":"2280_CR26","first-page":"1","volume":"6","author":"F Jacobs","year":"1998","unstructured":"Jacobs F, Sundermann E, Sutter B, Christiaens M, Lemahieu I (1998) A fast algorithm to calculate the exact radiological path through a pixel or voxel space. J Comput Inf Tech 6(1):1\u201312","journal-title":"J Comput Inf Tech"},{"issue":"8","key":"2280_CR27","doi-asserted-by":"publisher","first-page":"1257","DOI":"10.1007\/s11548-018-1732-8","volume":"13","author":"R Newell","year":"2018","unstructured":"Newell R, Esfandiari H, Anglin C, Bernard R, Street J, Hodgson A (2018) An intraoperative fluoroscopic method to accurately measure the post-implantation position of pedicle screws. Int J Comput Assist Radiol Surg 13(8):1257\u20131267","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"9","key":"2280_CR28","doi-asserted-by":"publisher","first-page":"1335","DOI":"10.1007\/s11548-018-1807-6","volume":"13","author":"P Stefan","year":"2018","unstructured":"Stefan P, Habert S, Winkler A, Lazarovici M, F\u00fcrmetz J, Eck U, Navab N (2018) A radiation-free mixed-reality training environment and assessment concept for C-arm-based surgery. Int J Comput Assist Radiol Surg 13(9):1335\u20131344","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"4","key":"2280_CR29","doi-asserted-by":"publisher","first-page":"695","DOI":"10.1007\/s11548-013-0957-9","volume":"9","author":"S Amiri","year":"2014","unstructured":"Amiri S, Wilson D, Masri B, Anglin C (2014) A low-cost tracked C-arm (TC-arm) upgrade system for versatile quantitative intraoperative imaging. Int J Comput Assist Radiol Surg 9(4):695\u2013711","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2280_CR30","doi-asserted-by":"publisher","first-page":"1597","DOI":"10.1007\/s11548-020-02229-5","volume":"15","author":"L Haliburton","year":"2020","unstructured":"Haliburton L, Esfandiari H, Guy P, Anglin C, Hodgson A (2020) A visual odometry base-tracking system for intraoperative C-arm guidance. Int J Comput Assist Radiol Surg 15:1597\u20131609","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2280_CR31","first-page":"671","volume":"2489","author":"F Wang","year":"2002","unstructured":"Wang F, Davis T, Vemuri B (2002) Real-time DRR generation using cylindrical harmonics. Med Image Comput Comput Assist Interv 2489:671\u2013678","journal-title":"Med Image Comput Comput Assist Interv"},{"issue":"11","key":"2280_CR32","doi-asserted-by":"publisher","first-page":"4302","DOI":"10.1118\/1.2789500","volume":"34","author":"J Spoerk","year":"2007","unstructured":"Spoerk J, Bergmann H, Wanschlitz F, Dong S, Birkfellner W (2007) Fast DRR splat rendering using common consumer graphics hardware. Med Phys 34(11):4302\u20134308","journal-title":"Med Phys"},{"key":"2280_CR33","first-page":"98","volume":"2018","author":"M Unberath","year":"2018","unstructured":"Unberath M, Zaech J, Lee S, Bier B, Fotouhi J, Armand M, Navab N (2018) DeepDRR: a catalyst for machine learning in fluoroscopy-guided procedures. Med Image Comput Comput Assist Interv 2018:98\u2013106","journal-title":"Med Image Comput Comput Assist Interv"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02280-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-020-02280-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02280-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,1,23]],"date-time":"2021-01-23T15:09:28Z","timestamp":1611414568000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-020-02280-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,11,4]]},"references-count":33,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2021,1]]}},"alternative-id":["2280"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02280-2","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2020,11,4]]},"assertion":[{"value":"12 January 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 October 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 November 2020","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest related to this study.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethics approval was received from the University of British Columbia Clinical Research Ethics Board (H15-00005) and by the British Columbia Institute of Technology Research Ethics Board (2016-09). All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki declaration and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}