{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,30]],"date-time":"2026-03-30T22:34:49Z","timestamp":1774910089781,"version":"3.50.1"},"reference-count":23,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T00:00:00Z","timestamp":1609632000000},"content-version":"tdm","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T00:00:00Z","timestamp":1609632000000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["JP19J23169"],"award-info":[{"award-number":["JP19J23169"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001691","name":"Japan Society for the Promotion of Science","doi-asserted-by":"publisher","award":["JP17H01252"],"award-info":[{"award-number":["JP17H01252"]}],"id":[{"id":"10.13039\/501100001691","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,2]]},"DOI":"10.1007\/s11548-020-02294-w","type":"journal-article","created":{"date-parts":[[2021,1,3]],"date-time":"2021-01-03T09:02:59Z","timestamp":1609664579000},"page":"289-299","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":8,"title":["A tactile sensor using the acoustic reflection principle for assessing the contact force component in laparoscopic tumor localization"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7878-6053","authenticated-orcid":false,"given":"Hiep Hoang","family":"Ly","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7917-1379","authenticated-orcid":false,"given":"Yoshihiro","family":"Tanaka","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Michitaka","family":"Fujiwara","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,3]]},"reference":[{"issue":"1","key":"2294_CR1","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1055\/s-2004-814113","volume":"36","author":"TN Robinson","year":"2004","unstructured":"Robinson TN, Stiegmann GV (2004) Minimally invasive surgery. Endoscopy 36(1):48\u201351","journal-title":"Endoscopy"},{"issue":"1","key":"2294_CR2","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1162\/105474699566062","volume":"8","author":"S Lederman","year":"1999","unstructured":"Lederman S, Klatzky R (1999) Sensing and displaying spatially distributed fingertip forces in haptic interfaces for teleoperator and virtual environment systems. Presence Teleoper Virtual Environ 8(1):86\u2013103","journal-title":"Presence Teleoper Virtual Environ"},{"issue":"4\u20135","key":"2294_CR3","doi-asserted-by":"publisher","first-page":"213","DOI":"10.3233\/CBM-2008-44-505","volume":"4","author":"K Hoyt","year":"2008","unstructured":"Hoyt K, Castaneda B, Zhang M, Nigwekar P, di Sant\u2019agnese PA, Joseph JV, Strang J, Rubens DJ, Parker KJ (2008) Tissue elasticity properties as biomarkers for prostate cancer. Cancer Biomark 4(4\u20135):213\u2013225","journal-title":"Cancer Biomark"},{"issue":"4","key":"2294_CR4","doi-asserted-by":"publisher","first-page":"260","DOI":"10.1177\/016173469802000403","volume":"20","author":"TA Krouskop","year":"1998","unstructured":"Krouskop TA, Wheeler TM, Kallel F, Garra BS, Hall T (1998) Elastic moduli of breast and prostate tissues under compression. Ultrason Imaging 20(4):260\u2013274","journal-title":"Ultrason Imaging"},{"key":"2294_CR5","unstructured":"Gwilliam JC, Pezzementi Z, Jantho E, Okamura AM, Hsiao S (2010) Human vs. robotic tactile sensing: detecting lumps in soft tissue. IEEE Haptics Symposium, pp\u00a021\u201328"},{"issue":"9","key":"2294_CR6","doi-asserted-by":"publisher","first-page":"3283","DOI":"10.1109\/JSEN.2014.2328182","volume":"14","author":"H Xie","year":"2014","unstructured":"Xie H, Liu H, Seneviratne LD, Althoefer K (2014) An optical tactile array probe head for tissue palpation during minimally invasive surgery. IEEE Sens J 14(9):3283\u20133291","journal-title":"IEEE Sens J"},{"issue":"4","key":"2294_CR7","doi-asserted-by":"publisher","first-page":"646","DOI":"10.1109\/TMECH.2011.2116033","volume":"17","author":"P Puangmali","year":"2012","unstructured":"Puangmali P, Liu H, Seneviratne LD, Dasgupta P, Althoefer K (2012) Miniature 3-axis distal force sensor for minimally invasive surgical palpation. IEEE ASME Trans Mechatron 17(4):646\u2013656","journal-title":"IEEE ASME Trans Mechatron"},{"issue":"2","key":"2294_CR8","doi-asserted-by":"publisher","first-page":"669","DOI":"10.1007\/s10439-019-02388-w","volume":"48","author":"C Lv","year":"2020","unstructured":"Lv C, Wang S, Shi C (2020) A high-precision and miniature fiber bragg grating-based force sensor for tissue palpation during minimally invasive surgery. Ann Biomed Eng 48(2):669\u2013681","journal-title":"Ann Biomed Eng"},{"issue":"2\u20133","key":"2294_CR9","doi-asserted-by":"publisher","first-page":"278","DOI":"10.1016\/j.sna.2004.01.038","volume":"112","author":"S Omata","year":"2004","unstructured":"Omata S, Murayama Y, Constantinou CE (2004) Real time robotic tactile sensor system for the determination of the physical properties of biomaterials. Sens Actuators A Phys 112(2\u20133):278\u2013285","journal-title":"Sens Actuators A Phys"},{"issue":"3","key":"2294_CR10","doi-asserted-by":"publisher","first-page":"2755","DOI":"10.1109\/TIE.2017.2739681","volume":"65","author":"U Kim","year":"2018","unstructured":"Kim U, Kim YB, Seok DY, So J, Choi HR (2018) A surgical palpation probe with 6-axis force\/torque sensing capability for minimally invasive surgery. IEEE Trans Ind Electron 65(3):2755\u20132765","journal-title":"IEEE Trans Ind Electron"},{"key":"2294_CR11","first-page":"137","volume-title":"Medical devices regulations, standards and practices","author":"S Ramakrishna","year":"2015","unstructured":"Ramakrishna S, Tian L, Wang C, Liao S, Teo WE (2015) Medical devices regulations, standards and practices. Elsevier Ltd, Amsterdam, pp 137\u2013153"},{"key":"2294_CR12","first-page":"e44","volume":"9","author":"RM Fish","year":"2009","unstructured":"Fish RM, Geddes LA (2009) Conduction of electrical current to and through the human body: a review. Eplasty 9:e44","journal-title":"Eplasty"},{"issue":"7","key":"2294_CR13","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.1243\/09544062JMES1917","volume":"224","author":"AL Trejos","year":"2010","unstructured":"Trejos AL, Patel RV, Naish MD (2010) Force sensing and its application in minimally invasive surgery: a survey. Proc Inst Mech Eng J Mech Eng Sci 224(7):1435\u20131454","journal-title":"Proc Inst Mech Eng J Mech Eng Sci"},{"issue":"2","key":"2294_CR14","doi-asserted-by":"publisher","first-page":"183","DOI":"10.1007\/s11548-014-1067-z","volume":"10","author":"Y Tanaka","year":"2015","unstructured":"Tanaka Y, Fukuda T, Fujiwara M, Sano A (2015) Tactile sensor using acoustic reflection for lump detection in laparoscopic surgery. Int J Comput Assist Radiol Surg 10(2):183\u2013193","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"2294_CR15","doi-asserted-by":"publisher","first-page":"e0171706","DOI":"10.1371\/journal.pone.0171706","volume":"12","author":"J Konstantinova","year":"2017","unstructured":"Konstantinova J, Cotugno G, Dasgupta P, Althoefer K, Nanayakkara T (2017) Palpation force modulation strategies to identify hard regions in soft tissue organs. PLoS ONE 12(2):e0171706","journal-title":"PLoS ONE"},{"key":"2294_CR16","doi-asserted-by":"crossref","unstructured":"Kim H, Choi S, Chung WK (2015) Feasibility of a novel indicator for lump detection using contact pressure distribution. In: Proceedings of IEEE\/RSJ international conference on robots and systems, pp 2111\u20132117","DOI":"10.1109\/IROS.2015.7353658"},{"key":"2294_CR17","doi-asserted-by":"publisher","DOI":"10.1201\/b17685","volume-title":"Resistive capacitive inductive and magnetic sensor technologies","author":"WY Du","year":"2014","unstructured":"Du WY (2014) Resistive capacitive inductive and magnetic sensor technologies. CRC Press, Boca Raton"},{"issue":"2","key":"2294_CR18","doi-asserted-by":"publisher","first-page":"101","DOI":"10.1007\/s10120-011-0041-5","volume":"14","author":"Japanese Gastric Cancer Association","year":"2011","unstructured":"Japanese Gastric Cancer Association (2011) Japanese classification of gastric carcinoma: 3rd English edition. Gastric Cancer 14(2):101\u2013112","journal-title":"Gastric Cancer"},{"issue":"2","key":"2294_CR19","doi-asserted-by":"publisher","first-page":"e1879","DOI":"10.1002\/rcs.1879","volume":"14","author":"T Fukuda","year":"2018","unstructured":"Fukuda T, Tanaka Y, Kappers AML, Fujiwara M, Sano A (2018) Visual and tactile feedback for a direct manipulating tactile sensor in laparoscopic palpation. Int J Med Robot Comput Assist Surg 14(2):e1879","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"4","key":"2294_CR20","doi-asserted-by":"publisher","first-page":"485","DOI":"10.1109\/TOH.2018.2854753","volume":"11","author":"T Fukuda","year":"2018","unstructured":"Fukuda T, Tanaka Y, Kappers AML, Fujiwara M, Sano A (2018) A pneumatic tactile ring for instantaneous sensory feedback in laparoscopic tumor localization. IEEE Trans Haptics 11(4):485\u2013497","journal-title":"IEEE Trans Haptics"},{"key":"2294_CR21","unstructured":"Lazeroms M, Villavicencio G, Jongkind W, Honderd G (1996) Optical fibre force sensor for minimal invasive surgery grasping instruments. In: Proceedings of the international conference of the IEEE engineering in medicine and biology society, Amsterdam, The Netherlands, pp 234\u2013235"},{"key":"2294_CR22","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1002\/rcs.169","volume":"4","author":"GL McCreery","year":"2008","unstructured":"McCreery GL, Trejos AL, Naish MD, Patel RV, Malthaner RA (2008) Feasibility of locating tumours in lung via kinaesthetic feedback. Int J Med Robot Comput Assist Surg 4:58\u201368","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"4","key":"2294_CR23","doi-asserted-by":"publisher","first-page":"3529","DOI":"10.1109\/LRA.2018.2853712","volume":"3","author":"S Akita","year":"2018","unstructured":"Akita S, Fukuda T, Tanaka Y, Kappers AML, Fujiwara M, Sano A (2018) Frequency-based temperature compensation for a tactile sensor using acoustic reflection. IEEE Robot Autom Lett 3(4):3529\u20133536","journal-title":"IEEE Robot Autom Lett"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02294-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-020-02294-w\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-020-02294-w.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,2,12]],"date-time":"2021-02-12T12:09:13Z","timestamp":1613131753000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-020-02294-w"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,3]]},"references-count":23,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2021,2]]}},"alternative-id":["2294"],"URL":"https:\/\/doi.org\/10.1007\/s11548-020-02294-w","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,1,3]]},"assertion":[{"value":"9 July 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"9 November 2020","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors have no conflict of interest to declare.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This article does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}