{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,1]],"date-time":"2025-11-01T13:55:00Z","timestamp":1762005300992,"version":"3.37.3"},"reference-count":30,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T00:00:00Z","timestamp":1611187200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T00:00:00Z","timestamp":1611187200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>In corrective osteotomy of the distal radius, patient-specific 3D printed surgical guides or optical navigation systems are often used to navigate the surgical saw. The purpose of this cadaver study is to present and evaluate a novel cast-based guiding system to transfer the virtually planned corrective osteotomy of the distal radius.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>We developed a cast-based guiding system composed of a cast featuring two drilling slots as well as an external cutting guide that was used to orient the surgical saw for osteotomy in the preoperatively planned position. The device was tested on five cadaver specimens with different body fat percentages. A repositioning experiment was performed to assess the precision of replacing an arm in the cast. Accuracy and precision of drilling and cutting using the proposed cast-based guiding system were evaluated using the same five cadaver arms. CT imaging was used to quantify the positioning errors in 3D.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>For normal-weight cadavers, the resulting total translation and rotation repositioning errors were\u2009\u00b1\u20092\u00a0mm and\u2009\u00b1\u20092\u00b0. Across the five performed surgeries, the median accuracy and Inter Quartile Ranges (IQR) of pre-operatively planned drilling trajectories were 4.3\u00b0 (IQR\u2009=\u20092.4\u00b0) and 3.1\u00a0mm (IQR\u2009=\u20094.9\u00a0mm). Median rotational and translational errors in transferring the pre-operatively planned osteotomy plane were and 3.9\u00b0 (IQR\u2009=\u20094.5\u00b0) and 2.6\u00a0mm (IQR\u2009=\u20094.2\u00a0mm), respectively.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>For normal weight arm specimens, navigation of corrective osteotomy via a cast-based guide resulted in transfer errors comparable to those using invasive surgical guides. The promising positioning capabilities justify further investigating whether the method could ultimately be used in a clinical setting, which could especially be of interest when used with less invasive osteosynthesis material.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-021-02310-7","type":"journal-article","created":{"date-parts":[[2021,1,21]],"date-time":"2021-01-21T11:03:57Z","timestamp":1611227037000},"page":"505-513","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":1,"title":["A 3D printed cast for minimally invasive transfer of distal radius osteotomy: a cadaver study"],"prefix":"10.1007","volume":"16","author":[{"given":"G.","family":"Caiti","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9454-6471","authenticated-orcid":false,"given":"J. G. G.","family":"Dobbe","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"S. D.","family":"Strackee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M. H. M.","family":"van Doesburg","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. J.","family":"Strijkers","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G. J.","family":"Streekstra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,1,21]]},"reference":[{"key":"2310_CR1","doi-asserted-by":"publisher","first-page":"27","DOI":"10.5435\/00124635-200701000-00004","volume":"15","author":"BD Bushnell","year":"2007","unstructured":"Bushnell BD, Bynum DK (2007) Malunion of the distal radius. J Am Acad Orthop Surg 15:27\u201340. https:\/\/doi.org\/10.5435\/00124635-200701000-00004","journal-title":"J Am Acad Orthop Surg"},{"key":"2310_CR2","doi-asserted-by":"publisher","first-page":"1164","DOI":"10.2106\/00004623-198264080-00007","volume":"64","author":"DL Fernandez","year":"1982","unstructured":"Fernandez DL (1982) Correction of post-traumatic wrist deformity in adults by osteotomy, bone-grafting, and internal fixation. J Bone Joint Surg Am 64:1164\u20131178","journal-title":"J Bone Joint Surg Am"},{"key":"2310_CR3","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1016\/j.jhsa.2011.12.035","volume":"37A","author":"JC Vroemen","year":"2012","unstructured":"Vroemen JC, Dobbe JGG, Jonges R, Strackee SD, Streekstra GJ (2012) Three-dimensional assessment of bilateral symmetry of the radius and ulna for planning corrective surgeries. J Hand Surg 37A:982\u2013988. https:\/\/doi.org\/10.1016\/j.jhsa.2011.12.035","journal-title":"J Hand Surg"},{"key":"2310_CR4","doi-asserted-by":"publisher","first-page":"713","DOI":"10.1007\/s11548-013-0966-8","volume":"9","author":"B Ma","year":"2014","unstructured":"Ma B, Kunz M, Gammon B, Ellis RE, Pichora DR (2014) A laboratory comparison of computer navigation and individualized guides for distal radius osteotomy. Int J Comput Assist Radiol Surg 9:713\u2013724. https:\/\/doi.org\/10.1007\/s11548-013-0966-8","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2310_CR5","doi-asserted-by":"publisher","first-page":"2041","DOI":"10.1016\/j.jhsa.2012.07.013","volume":"37","author":"GA Buijze","year":"2012","unstructured":"Buijze GA, Prommersberger KJ, Gonz\u00e1lez Del Pino J, Fernandez DL, Jupiter JB (2012) Corrective osteotomy for combined intra- and extra-articular distal radius malunion. J Hand Surg Am 37:2041\u20132049. https:\/\/doi.org\/10.1016\/j.jhsa.2012.07.013","journal-title":"J Hand Surg Am"},{"key":"2310_CR6","doi-asserted-by":"publisher","first-page":"464","DOI":"10.1016\/j.jhsa.2015.12.022","volume":"41","author":"P Honigmann","year":"2016","unstructured":"Honigmann P, Thieringer F, Steiger R, Haefeli M, Schumacher R, Henning J (2016) A Simple 3-dimensional printed aid for a corrective palmar opening wedge osteotomy of the distal radius. J Hand Surg Am 41:464\u2013469. https:\/\/doi.org\/10.1016\/j.jhsa.2015.12.022","journal-title":"J Hand Surg Am"},{"key":"2310_CR7","doi-asserted-by":"publisher","first-page":"2339","DOI":"10.1016\/j.jhsa.2013.09.023","volume":"38","author":"A Schweizer","year":"2013","unstructured":"Schweizer A, F\u00fcrnstahl P, Nagy L (2013) Three-dimensional correction of distal radius intra-articular malunions using patient-specific drill guides. J Hand Surg Am 38:2339\u20132347. https:\/\/doi.org\/10.1016\/j.jhsa.2013.09.023","journal-title":"J Hand Surg Am"},{"key":"2310_CR8","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1109\/MPUL.2013.2279617","volume":"4","author":"J Banks","year":"2013","unstructured":"Banks J (2013) Adding value in additive manufacturing: researchers in the United Kingdom and Europe look to 3D printing for customization. IEEE Pulse 4:22\u201326. https:\/\/doi.org\/10.1109\/MPUL.2013.2279617","journal-title":"IEEE Pulse"},{"key":"2310_CR9","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1007\/s11548-017-1682-6","volume":"13","author":"G Caiti","year":"2018","unstructured":"Caiti G, Dobbe JGG, Strijkers GJ, Strackee SD, Streekstra GJ (2018) Positioning error of custom 3D-printed surgical guides for the radius: influence of fitting location and guide design. Int J Comput Assist Radiol Surg 13:507\u2013518. https:\/\/doi.org\/10.1007\/s11548-017-1682-6","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2310_CR10","doi-asserted-by":"publisher","first-page":"115","DOI":"10.1186\/s12938-016-0236-4","volume":"15","author":"P Tack","year":"2016","unstructured":"Tack P, Victor J, Gemmel P, Annemans L (2016) 3D-printing techniques in a medical setting: a systematic literature review. Biomed Eng Online 15:115. https:\/\/doi.org\/10.1186\/s12938-016-0236-4","journal-title":"Biomed Eng Online"},{"key":"2310_CR11","doi-asserted-by":"publisher","first-page":"41","DOI":"10.1016\/j.medengphy.2018.05.001","volume":"58","author":"JGG Dobbe","year":"2018","unstructured":"Dobbe JGG, Caiti G, Schreurs AW, Strackee SD, Beerens M, Streekstra GJ (2018) Positioning accuracy of a patient-tailored rimmed wedge implant for corrective osteotomy of the distal radius. Med Eng Phys 58:41\u201346. https:\/\/doi.org\/10.1016\/j.medengphy.2018.05.001","journal-title":"Med Eng Phys"},{"key":"2310_CR12","doi-asserted-by":"publisher","first-page":"333","DOI":"10.1016\/J.OTSR.2015.12.024","volume":"102","author":"X-M Wei","year":"2016","unstructured":"Wei X-M, Sun Z-Z, Rui Y-J, Song X-J, Jiang W-M (2016) Minimally invasive percutaneous plate osteosynthesis for distal radius fractures with long-segment metadiaphyseal comminution. Orthop Traumatol Surg Res 102:333\u2013338. https:\/\/doi.org\/10.1016\/J.OTSR.2015.12.024","journal-title":"Orthop Traumatol Surg Res"},{"key":"2310_CR13","doi-asserted-by":"publisher","first-page":"861","DOI":"10.1016\/j.otsr.2015.07.016","volume":"101","author":"C Taleb","year":"2015","unstructured":"Taleb C, Zemirline A, Lebailly F, Bodin F, Facca S, Gouzou S, Liverneaux P (2015) Minimally invasive osteotomy for distal radius malunion: a preliminary series of 9 cases. Orthop Traumatol Surg Res 101:861\u2013865. https:\/\/doi.org\/10.1016\/j.otsr.2015.07.016","journal-title":"Orthop Traumatol Surg Res"},{"key":"2310_CR14","doi-asserted-by":"publisher","first-page":"62","DOI":"10.4055\/cios.2011.3.1.62","volume":"3","author":"JK Oh","year":"2011","unstructured":"Oh JK, Hwang JH, Sahu D, Jun SH (2011) Complication rate and pitfalls of temporary bridging external fixator in periarticular comminuted fractures. Clin Orth Surg 3:62\u201368. https:\/\/doi.org\/10.4055\/cios.2011.3.1.62","journal-title":"Clin Orth Surg"},{"key":"2310_CR15","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s11548-013-0834-6","volume":"9","author":"EJ Smith","year":"2014","unstructured":"Smith EJ, Allan G, Gammon B, Sellens RW, Ellis RE, Pichora DR (2014) Investigating the performance of a wrist stabilization device for image-guided percutaneous scaphoid fixation. Int J Comput Assist Radiol Surg 9:155\u2013164. https:\/\/doi.org\/10.1007\/s11548-013-0834-6","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2310_CR16","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1002\/rcs.194","volume":"4","author":"PA Liverneaux","year":"2008","unstructured":"Liverneaux PA, Gherissi A, Stefanelli MB (2008) Kirschner wire placement in scaphoid bones using fluoroscopic navigation: a cadaver study comparing conventional techniques with navigation. Int J Med Robot Comput Assist Surg 4:165\u2013173. https:\/\/doi.org\/10.1002\/rcs.194","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"2310_CR17","doi-asserted-by":"publisher","first-page":"165","DOI":"10.3109\/13645706.2012.724688","volume":"22","author":"C Niederwanger","year":"2013","unstructured":"Niederwanger C, Widmann G, Knoflach M, Schullian P, Hoermann R, Bale R (2013) Kirschner wire placement in scaphoid bones using intraoperative CT-guided stereotaxy. Minim Invasive Ther Allied Technol 22:165\u2013170. https:\/\/doi.org\/10.3109\/13645706.2012.724688","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"2310_CR18","doi-asserted-by":"publisher","first-page":"109","DOI":"10.1007\/s11751-015-0234-2","volume":"10","author":"MMJ Walenkamp","year":"2015","unstructured":"Walenkamp MMJ, de Muinck Keizer RJO, Dobbe JGG, Streekstra GJ, Goslings JC, Kloen P, Strackee SD, Schep NWL (2015) Computer-assisted 3D planned corrective osteotomies in eight malunited radius fractures. Strateg Trauma Limb Reconstr 10:109\u2013116. https:\/\/doi.org\/10.1007\/s11751-015-0234-2","journal-title":"Strateg Trauma Limb Reconstr"},{"key":"2310_CR19","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1109\/TBME.2010.2084576","volume":"58","author":"JGG Dobbe","year":"2011","unstructured":"Dobbe JGG, Strackee SD, Schreurs AW, Jonges R, Carelsen B, Vroemen JC, Grimbergen CA, Streekstra GJ (2011) Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging. IEEE Trans Biomed Eng 58:182\u2013190. https:\/\/doi.org\/10.1109\/TBME.2010.2084576","journal-title":"IEEE Trans Biomed Eng"},{"key":"2310_CR20","doi-asserted-by":"publisher","first-page":"791","DOI":"10.1007\/s11517-013-1049-2","volume":"51","author":"JGG Dobbe","year":"2013","unstructured":"Dobbe JGG, Vroemen JC, Strackee SD, Streekstra GJ (2013) Corrective distal radius osteotomy: including bilateral differences in 3-D planning. Med Biol Eng Comput 51:791\u2013797. https:\/\/doi.org\/10.1007\/s11517-013-1049-2","journal-title":"Med Biol Eng Comput"},{"key":"2310_CR21","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s11517-012-0959-8","volume":"51","author":"JGG Dobbe","year":"2013","unstructured":"Dobbe JGG, Vroemen JC, Strackee SD, Streekstra GJ (2013) Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy. Med Biol Eng Comput 51:19\u201327. https:\/\/doi.org\/10.1007\/s11517-012-0959-8","journal-title":"Med Biol Eng Comput"},{"key":"2310_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-018-1896-2","author":"G Caiti","year":"2018","unstructured":"Caiti G, Dobbe JGG, Loenen ACY, Beerens M, Strackee SD, Strijkers GJ, Streekstra GJ (2018) Implementation of a semiautomatic method to design patient-specific instruments for corrective osteotomy of the radius. Int J Comput Assist Radiol Surg. https:\/\/doi.org\/10.1007\/s11548-018-1896-2","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2310_CR23","doi-asserted-by":"publisher","DOI":"10.1109\/TMI.2018.2877503","author":"JGG Dobbe","year":"2018","unstructured":"Dobbe JGG, de Roo MGA, Visschers JC, Strackee SD, Streekstra GJ (2018) Evaluation of a quantitative method for carpal motion analysis using clinical 3D and 4D CT protocols. IEEE Trans Med Imag. https:\/\/doi.org\/10.1109\/TMI.2018.2877503","journal-title":"IEEE Trans Med Imag"},{"key":"2310_CR24","unstructured":"Polytechnic University 3D Printing Case Study | Stratasys. https:\/\/www.stratasys.com\/resources\/search\/case-studies\/polytechnic-university. Accessed 17 Aug 2019"},{"key":"2310_CR25","doi-asserted-by":"publisher","unstructured":"Kuo HY, Su HR, Lai SH, Wu CC (2014) 3D object detection and pose estimation from depth image for robotic bin picking. IEEE Int Conf Autom Sci Eng 2014-Janua: 1264\u20131269. https:\/\/doi.org\/10.1109\/CoASE.2014.6899489","DOI":"10.1109\/CoASE.2014.6899489"},{"key":"2310_CR26","doi-asserted-by":"publisher","first-page":"e0160480","DOI":"10.1371\/journal.pone.0160480","volume":"11","author":"N Ben\u00edtez Brito","year":"2016","unstructured":"Ben\u00edtez Brito N, Su\u00e1rez Llanos JP, Fuentes Ferrer M, Oliva Garc\u00eda JG, Delgado Brito I, Pereyra-Garc\u00eda Castro F, Caracena Castellanos N, Acevedo Rodr\u00edguez CX, Palacio Abizanda E (2016) Relationship between mid-upper arm circumference and body mass index in inpatients. PLoS ONE 11:e0160480. https:\/\/doi.org\/10.1371\/journal.pone.0160480","journal-title":"PLoS ONE"},{"key":"2310_CR27","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1016\/j.medengphy.2014.05.012","volume":"36","author":"JGG Dobbe","year":"2014","unstructured":"Dobbe JGG, Kievit AJ, Schafroth MU, Blankevoort L, Streekstra GJ (2014) Evaluation of a CT-based technique to measure the transfer accuracy of a virtually planned osteotomy. Med Eng Phys 36:1081\u20131087. https:\/\/doi.org\/10.1016\/j.medengphy.2014.05.012","journal-title":"Med Eng Phys"},{"key":"2310_CR28","unstructured":"The Practical Guide Identification, Evaluation, and Treatment of Overweight and Obesity in Adults NHLBI Obesity Education Initiative"},{"key":"2310_CR29","doi-asserted-by":"publisher","first-page":"159","DOI":"10.1016\/J.JOCN.2018.03.012","volume":"52","author":"J Li","year":"2018","unstructured":"Li J, Lin J, Yang Y, Xu J, Fei Q (2018) 3-Dimensional printing guide template assisted percutaneous vertebroplasty: technical note. J Clin Neurosci 52:159\u2013164. https:\/\/doi.org\/10.1016\/J.JOCN.2018.03.012","journal-title":"J Clin Neurosci"},{"key":"2310_CR30","doi-asserted-by":"publisher","first-page":"301.e1","DOI":"10.1016\/j.jhsa.2017.01.017","volume":"42","author":"HW Yin","year":"2017","unstructured":"Yin HW, Xu J, Xu WD (2017) 3-Dimensional printing-assisted percutaneous fixation for acute scaphoid fracture: 1-shot procedure. J Hand Surg Am 42:301.e1-301.e5. https:\/\/doi.org\/10.1016\/j.jhsa.2017.01.017","journal-title":"J Hand Surg Am"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02310-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-021-02310-7\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02310-7.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,10]],"date-time":"2021-03-10T05:21:51Z","timestamp":1615353711000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-021-02310-7"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,1,21]]},"references-count":30,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["2310"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02310-7","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"type":"print","value":"1861-6410"},{"type":"electronic","value":"1861-6429"}],"subject":[],"published":{"date-parts":[[2021,1,21]]},"assertion":[{"value":"26 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"21 January 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"This article does not contain any studies involving animals performed by any of the authors.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}},{"value":"Formal consent is not required for this type of study.","order":6,"name":"Ethics","group":{"name":"EthicsHeading","label":"Retrospective studies"}}]}}