{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T21:53:11Z","timestamp":1785880391183,"version":"3.56.0"},"reference-count":42,"publisher":"Springer Science and Business Media LLC","issue":"3","license":[{"start":{"date-parts":[[2021,2,11]],"date-time":"2021-02-11T00:00:00Z","timestamp":1613001600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,2,11]],"date-time":"2021-02-11T00:00:00Z","timestamp":1613001600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/100013297","name":"Eurostars","doi-asserted-by":"crossref","award":["ID 9809"],"award-info":[{"award-number":["ID 9809"]}],"id":[{"id":"10.13039\/100013297","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,3]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Corrective osteotomy of a malunited distal radius conventionally relies on 2D imaging techniques for alignment planning and evaluation. However, this approach results in suboptimal bone repositioning, which is associated with poor patient outcomes. In this case series, we evaluate the use of novel patient-specific plates (PSPs), which feature navigation and fixation of bone segments as preoperatively planned in 3D.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Ten participants with distal radius malunion underwent CT scans for preoperative alignment planning. Patient-specific guides and plates were designed, 3D-printed, and sterilized for use in corrective surgery of the distal radius. Pre- and postoperative results were compared in regard to clinical, functional, and radiographic outcomes.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The application of a PSP was successful in 7 of the 10 cases. After treatment, the residual alignment error was reduced by approximately 50% compared with conventional treatment. The use of PSPs reduced pain significantly. Pre- and postoperative results were pooled and demonstrated significant correlations between: (1) pain and malpositioning, (2) the range of pro- and supination motion, the MHOQ score, the EQ-5D-5L score and dorsovolar angulation, and (3) MHOQ score and proximodistal translation.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The correlation between malalignment and MHOQ score, EQ-5D-5L score, pain, and range of motion shows that alignment should be restored as well as possible. Compared to the conventional approach, which relies on 2D imaging techniques, corrective osteotomy based on 3D preoperative planning and intraoperative fixation with a PSP has been shown to improve bone alignment and reduce pain.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Level of evidence<\/jats:title>\n                <jats:p>IV.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-021-02320-5","type":"journal-article","created":{"date-parts":[[2021,2,11]],"date-time":"2021-02-11T18:05:44Z","timestamp":1613066744000},"page":"515-524","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":26,"title":["Patient-specific plate for navigation and fixation of the distal radius: a case series"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9454-6471","authenticated-orcid":false,"given":"Johannes G. G.","family":"Dobbe","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3312-0469","authenticated-orcid":false,"given":"Abbas","family":"Peymani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hendrika A. L.","family":"Roos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Maikel","family":"Beerens","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5590-7633","authenticated-orcid":false,"given":"Geert J.","family":"Streekstra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1487-5559","authenticated-orcid":false,"given":"Simon D.","family":"Strackee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,2,11]]},"reference":[{"key":"2320_CR1","doi-asserted-by":"publisher","first-page":"613","DOI":"10.2106\/00004623-198062040-00016","volume":"62","author":"WP Cooney","year":"1980","unstructured":"Cooney WP, Dobyns JH, Linscheid RL (1980) Complications of Colles\u2019 fractures. J Bone Joint Surg Am 62:613\u2013619","journal-title":"J Bone Joint Surg Am"},{"key":"2320_CR2","doi-asserted-by":"publisher","first-page":"207","DOI":"10.1055\/s-0035-1558831","volume":"4","author":"DJG Disseldorp","year":"2015","unstructured":"Disseldorp DJG, Poeze M, Hannemann PFW, Brink PRG (2015) Is bone grafting necessary in the treatment of malunited distal radius fractures? J Wrist Surg 4:207\u2013213. https:\/\/doi.org\/10.1055\/s-0035-1558831","journal-title":"J Wrist Surg"},{"issue":"4","key":"2320_CR3","doi-asserted-by":"publisher","first-page":"266","DOI":"10.1016\/j.jassh.2004.09.007","volume":"4","author":"MW Patton","year":"2004","unstructured":"Patton MW (2004) Distal radius malunion. J Am Soc Surg Hand 4(4):266\u2013274. https:\/\/doi.org\/10.1016\/j.jassh.2004.09.007","journal-title":"J Am Soc Surg Hand"},{"key":"2320_CR4","doi-asserted-by":"publisher","first-page":"148","DOI":"10.1007\/s00068-005-1405-5","volume":"2","author":"AWJ Wieland","year":"2004","unstructured":"Wieland AWJ, Dekkers GHG, Brink PRG (2004) Open wedge osteotomy for malunited extraarticular distal radius fractures with plate osteosynthesis without bone grafting. Eur J Trauma 2:148\u2013153. https:\/\/doi.org\/10.1007\/s00068-005-1405-5","journal-title":"Eur J Trauma"},{"key":"2320_CR5","doi-asserted-by":"publisher","DOI":"10.1007\/978-3-642-59373-4","volume-title":"Principles of deformity correction","author":"D Paley","year":"2002","unstructured":"Paley D (2002) Principles of deformity correction. Springer, Berlin"},{"key":"2320_CR6","doi-asserted-by":"publisher","first-page":"909","DOI":"10.1016\/j.jhsa.2013.02.02410.1016\/j.jhsa.2017.07.002","volume":"38A","author":"T Kataoka","year":"2013","unstructured":"Kataoka T, Oka K, Miyake J, Omori S, Tanaka H, Murase T (2013) 3-Dimensional prebent plate fixation in corrective osteotomy of malunited upper extremity fractures using real-sized plastic bone model prepared by preoperative computer simulation. J Hand Surg 38A:909\u2013919. https:\/\/doi.org\/10.1016\/j.jhsa.2013.02.02410.1016\/j.jhsa.2017.07.002","journal-title":"J Hand Surg"},{"issue":"4","key":"2320_CR7","doi-asserted-by":"publisher","first-page":"e457","DOI":"10.3928\/01477447-20130327-22","volume":"36","author":"JC Vroemen","year":"2013","unstructured":"Vroemen JC, Dobbe JGG, Sierevelt IN, Strackee SD, Streekstra GJ (2013) Accuracy of distal radius positioning using an anatomical plate. Orthopedics 36(4):e457\u2013e462. https:\/\/doi.org\/10.3928\/01477447-20130327-22","journal-title":"Orthopedics"},{"issue":"2","key":"2320_CR8","doi-asserted-by":"publisher","first-page":"e193","DOI":"10.3928\/01477447-20130122-22","volume":"36","author":"JC Vroemen","year":"2013","unstructured":"Vroemen JC, Dobbe JGG, Strackee SD, Streekstra GJ (2013) Positioning evaluation of corrective osteotomy for the malunited radius: 3-D CT versus 2-D radiographs. Orthopedics 36(2):e193\u2013e199. https:\/\/doi.org\/10.3928\/01477447-20130122-22","journal-title":"Orthopedics"},{"key":"2320_CR9","doi-asserted-by":"publisher","first-page":"951","DOI":"10.1016\/s0363-5023(03)00375-7","volume":"28A","author":"GS Athwal","year":"2003","unstructured":"Athwal GS, Ellis RE, Small CF, Pichora DR (2003) Computer-assisted distal radius osteotomy. J Hand Surg 28A:951\u2013958. https:\/\/doi.org\/10.1016\/s0363-5023(03)00375-7","journal-title":"J Hand Surg"},{"issue":"5","key":"2320_CR10","doi-asserted-by":"publisher","first-page":"829","DOI":"10.1007\/s11548-018-1896-2","volume":"14","author":"G Caiti","year":"2019","unstructured":"Caiti G, Dobbe JGG, Loenen ACY, Beerens M, Strackee SD, Strijkers GJ, Streekstra GJ (2019) Implementation of a semiautomatic method to design patient-specific instruments for corrective osteotomy of the radius. Int J Comp Assist Radiol Surg 14(5):829\u2013840. https:\/\/doi.org\/10.1007\/s11548-018-1896-2","journal-title":"Int J Comp Assist Radiol Surg"},{"key":"2320_CR11","doi-asserted-by":"publisher","DOI":"10.1016\/j.media.2019.101598","author":"F Carrillo","year":"2020","unstructured":"Carrillo F, Roner S, Von Atzigen M, Schweizer A, Nagy L, Vlachopoulos L, Snedeker JG, F\u00fcrnstahl P (2020) An automatic genetic algorithm framework for the optimization of three-dimensional surgical plans of forearm corrective osteotomies. Med Image Anal. https:\/\/doi.org\/10.1016\/j.media.2019.101598","journal-title":"Med Image Anal"},{"key":"2320_CR12","doi-asserted-by":"publisher","first-page":"58","DOI":"10.1016\/j.compmedimag.2008.10.005","volume":"33","author":"L Ciocca","year":"2009","unstructured":"Ciocca L, De Crescenzio F, Fantini M, Scotti R (2009) CAD\/CAM and rapid prototyped scaffold construction for bone regenerative medicine and surgical transfer of virtual planning: a pilot study. Comput Med Image Gr 33:58\u201362. https:\/\/doi.org\/10.1016\/j.compmedimag.2008.10.005","journal-title":"Comput Med Image Gr"},{"issue":"1","key":"2320_CR13","doi-asserted-by":"publisher","first-page":"182","DOI":"10.1109\/tbme.2010.2084576","volume":"58","author":"JGG Dobbe","year":"2011","unstructured":"Dobbe JGG, Strackee SD, Schreurs AW, Jonges R, Carelsen B, Vroemen JC, Grimbergen CA, Streekstra GJ (2011) Computer-assisted planning and navigation for corrective distal radius osteotomy, based on pre- and intraoperative imaging. IEEE Trans Biomed Eng 58(1):182\u2013190. https:\/\/doi.org\/10.1109\/tbme.2010.2084576","journal-title":"IEEE Trans Biomed Eng"},{"issue":"5","key":"2320_CR14","doi-asserted-by":"publisher","first-page":"982","DOI":"10.1016\/j.jhsa.2011.12.035","volume":"37","author":"JC Vroemen","year":"2012","unstructured":"Vroemen JC, Dobbe JGG, Jonges R, Strackee SD, Streekstra GJ (2012) Three-dimensional assessment of bilateral symmetry of the radius and ulna for planning corrective surgeries. J Hand Surg Am 37(5):982\u2013988. https:\/\/doi.org\/10.1016\/j.jhsa.2011.12.035","journal-title":"J Hand Surg Am"},{"key":"2320_CR15","doi-asserted-by":"publisher","first-page":"19","DOI":"10.1007\/s11517-012-0959-8","volume":"51","author":"JGG Dobbe","year":"2013","unstructured":"Dobbe JGG, Vroemen JC, Strackee SD, Streekstra GJ (2013) Patient-tailored plate for bone fixation and accurate 3D positioning in corrective osteotomy. Med Biol Eng Comput 51:19\u201327. https:\/\/doi.org\/10.1007\/s11517-012-0959-8","journal-title":"Med Biol Eng Comput"},{"issue":"3","key":"2320_CR16","doi-asserted-by":"publisher","first-page":"179","DOI":"10.1007\/s11751-014-0203-1","volume":"9","author":"JGG Dobbe","year":"2014","unstructured":"Dobbe JGG, Vroemen JC, Strackee SD, Streekstra GJ (2014) Patient-specific distal radius locking plate for fixation and accurate 3D positioning in corrective osteotomy. Strateg Trauma Limb Reconstr 9(3):179\u2013183. https:\/\/doi.org\/10.1007\/s11751-014-0203-1","journal-title":"Strateg Trauma Limb Reconstr"},{"issue":"4","key":"2320_CR17","doi-asserted-by":"publisher","first-page":"1048","DOI":"10.1109\/tmi.2018.2877503","volume":"38","author":"JGG Dobbe","year":"2019","unstructured":"Dobbe JGG, De Roo MGA, Visschers JC, Strackee SD, Streekstra GJ (2019) Evaluation of a quantitative method for carpal motion analysis using clinical 3-D and 4D CT protocols. IEEE Trans Med Imaging 38(4):1048\u20131057. https:\/\/doi.org\/10.1109\/tmi.2018.2877503","journal-title":"IEEE Trans Med Imaging"},{"issue":"11","key":"2320_CR18","doi-asserted-by":"publisher","first-page":"2375","DOI":"10.2106\/jbjs.g.01299","volume":"90","author":"T Murase","year":"2008","unstructured":"Murase T, Kunihiro O, Moritomo H, Goto A, Yoshikawa H, Sugamoto K (2008) Three-dimensional corrective osteotomy of malunited fractures of the upper extremity with use of a computer simulation system. J Bone Joint Surg Am 90(11):2375\u20132389. https:\/\/doi.org\/10.2106\/jbjs.g.01299","journal-title":"J Bone Joint Surg Am"},{"key":"2320_CR19","doi-asserted-by":"publisher","first-page":"1766","DOI":"10.1007\/s11999-010-1748-z","volume":"469","author":"J Miyake","year":"2011","unstructured":"Miyake J, Murase T, Moritomo H, Sugamoto K, Yoshikawa H (2011) Distal radius osteotomy with volar locking plates based on computer simulation. Clin Orthop Relat Res 469:1766\u20131773. https:\/\/doi.org\/10.1007\/s11999-010-1748-z","journal-title":"Clin Orthop Relat Res"},{"key":"2320_CR20","doi-asserted-by":"publisher","first-page":"196","DOI":"10.1002\/rcs.1530","volume":"10","author":"S Omori","year":"2014","unstructured":"Omori S, Murase T, Kataoka T, Kawanishi Y, Oura K, Miyake J, Tanaka H, Yoshikawa H (2014) Three-dimensional corrective osteotomy using a patient-specific osteotomy guide and bone plate based on a computer simulation system: accuracy analysis in a cadaver study. J Med Robot Comput Assist Surg 10:196\u2013202. https:\/\/doi.org\/10.1002\/rcs.1530","journal-title":"J Med Robot Comput Assist Surg"},{"key":"2320_CR21","doi-asserted-by":"publisher","first-page":"123","DOI":"10.1007\/978-3-319-23482-3_7","volume":"23","author":"P F\u00fcrnstahl","year":"2015","unstructured":"F\u00fcrnstahl P, Schweizer A, Graf M, Vlachopoulos L, Fucentses S, Wirth S, Nagy L, Szekely G, Goksel O (2015) Surgical treatment of long-bone deformities: 3D preoperative planning and patient-specific instrumentation. Comput Radiol Orthop Interv 23:123\u2013149. https:\/\/doi.org\/10.1007\/978-3-319-23482-3_7","journal-title":"Comput Radiol Orthop Interv"},{"issue":"4","key":"2320_CR22","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1177\/1753193419893561","volume":"45","author":"Y G\u00f6ren","year":"2020","unstructured":"G\u00f6ren Y, Sauerbier M, Arsalan-Werner A (2020) Impact of Soong grading on flexor tendon ruptures following palmar plating for distal radius fractures. J Hand Surg 45(4):348\u2013353. https:\/\/doi.org\/10.1177\/1753193419893561","journal-title":"J Hand Surg"},{"issue":"5","key":"2320_CR23","doi-asserted-by":"publisher","first-page":"370","DOI":"10.1177\/1753193409357373","volume":"35E","author":"SA Lozano-Calderon","year":"2010","unstructured":"Lozano-Calderon SA, Brouwer KM, Doornberg JN, Goslings JC, Kloen P, Jupiter JB (2010) Long-term outcomes of corrective osteotomy for the treatment of distal radius malunion. J Hand Surg (Eur) 35E(5):370\u2013380. https:\/\/doi.org\/10.1177\/1753193409357373","journal-title":"J Hand Surg (Eur)"},{"issue":"8","key":"2320_CR24","doi-asserted-by":"publisher","first-page":"710","DOI":"10.2106\/JBJS.18.00765","volume":"101","author":"K Oka","year":"2019","unstructured":"Oka K, Tanaka H, Okada K, Sahara W, Myoui A, Yamada T, Yamamoto M, Kurimoto S, Hirata H, Murase T (2019) Three-dimensional corrective osteotomy for malunited fractures of the upper extremity using patient-matched instruments. A prospective, multicenter, open-label, single-arm trial. J Bone Joint Surg 101(8):710\u2013721. https:\/\/doi.org\/10.2106\/JBJS.18.00765","journal-title":"J Bone Joint Surg"},{"issue":"10","key":"2320_CR25","doi-asserted-by":"publisher","first-page":"836.e1","DOI":"10.1016\/j.jhsa.2017.06.003","volume":"42","author":"AM Byrne","year":"2017","unstructured":"Byrne AM, Impelmans B, Bertrand V, Van Haver A, Verstreken F (2017) Corrective osteotomy for malunited diaphyseal forearm fractures using preoperative 3-dimensional planning and patient-specific surgical guides and implants. J Hand Surg Am 42(10):836.e1-e12. https:\/\/doi.org\/10.1016\/j.jhsa.2017.06.003","journal-title":"J Hand Surg Am"},{"key":"2320_CR26","doi-asserted-by":"publisher","first-page":"163","DOI":"10.1145\/37401.37422","volume":"21","author":"WE Lorenzen","year":"1987","unstructured":"Lorenzen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. Comput Gr 21:163\u2013169. https:\/\/doi.org\/10.1145\/37401.37422","journal-title":"Comput Gr"},{"key":"2320_CR27","doi-asserted-by":"publisher","first-page":"S17","DOI":"10.1016\/j.otsr.2010.03.008","volume":"956","author":"F Cronier","year":"2010","unstructured":"Cronier F, Pietu G, Dujardin C, Bigorre N, Ducellier F, Gerard R (2010) The concept of locking plates. Orthop Traumatol Surg Res 956:S17\u2013S36. https:\/\/doi.org\/10.1016\/j.otsr.2010.03.008","journal-title":"Orthop Traumatol Surg Res"},{"issue":"11","key":"2320_CR28","doi-asserted-by":"publisher","first-page":"2236","DOI":"10.1016\/j.jhsa.2015.07.034","volume":"40","author":"M Nishiwaki","year":"2015","unstructured":"Nishiwaki M, Welsh MF, Gammon B, Ferreira LM, Johnson JA, King GJW (2015) Effect of volarly angulated distal radius fractures on formarm rotation and distal radiolnar joint kinematics. J Hand Surg Am 40(11):2236\u20132242. https:\/\/doi.org\/10.1016\/j.jhsa.2015.07.034","journal-title":"J Hand Surg Am"},{"issue":"4","key":"2320_CR29","doi-asserted-by":"publisher","first-page":"547","DOI":"10.1002\/jor.20322","volume":"25","author":"JJ Crisco","year":"2007","unstructured":"Crisco JJ, Moore DC, Marai GE, Laidlaw DH, Akelman E, Weiss APC, Wolfe SW (2007) Effects of distal radius malunion on distal radioulnar joint mechanics\u2014an in vivo study. J Orthop Res 25(4):547\u2013555. https:\/\/doi.org\/10.1002\/jor.20322","journal-title":"J Orthop Res"},{"key":"2320_CR30","doi-asserted-by":"publisher","first-page":"98","DOI":"10.2174\/1874325001509010098","volume":"9","author":"K Barbaric","year":"2015","unstructured":"Barbaric K, Rujevcan G, Labas M, Delimar D, Bicanic G (2015) Ulnar shortening osteotomy after distal radius fracture malunion: review of the literature. Open Orth J 9:98\u2013106. https:\/\/doi.org\/10.2174\/1874325001509010098","journal-title":"Open Orth J"},{"key":"2320_CR31","doi-asserted-by":"publisher","first-page":"1531","DOI":"10.1007\/s00590-018-2265-0","volume":"28","author":"M Michielsen","year":"2018","unstructured":"Michielsen M, Van Haver A, Bertrand V, Vanhees M, Verstreken F (2018) Corrective osteotomy of distal radius malunions using three-dimensional computer simulation and patient-specific guides to achieve anatomic reduction. Eur J Orthopaed Surg Traumatol 28:1531\u20131535. https:\/\/doi.org\/10.1007\/s00590-018-2265-0","journal-title":"Eur J Orthopaed Surg Traumatol"},{"issue":"336","key":"2320_CR32","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1186\/s12891-015-0793-x","volume":"16","author":"L Vlachopoulos","year":"2015","unstructured":"Vlachopoulos L, Schweizer A, Graf M, Nagy L, F\u00fcrnstahl P (2015) Three-dimensional postoperative accuracy of extra-articular forearm osteotomies using CT-scan based patient-specific surgical guides. BMC Musculoskelet Disord 16(336):1\u20138. https:\/\/doi.org\/10.1186\/s12891-015-0793-x","journal-title":"BMC Musculoskelet Disord"},{"issue":"12","key":"2320_CR33","doi-asserted-by":"publisher","first-page":"1031.e1","DOI":"10.1016\/j.jhsa.2017.07.002","volume":"42","author":"S Roner","year":"2017","unstructured":"Roner S, Vlachopoulos L, Nagy L, F\u00fcrnstahl SAP (2017) Accuracy and early clinical outcome of 3-dimensional planned and guided single-cut osteotomies of malunited forearm bones. J Hand Surg Am 42(12):1031.e1-1031.e8. https:\/\/doi.org\/10.1016\/j.jhsa.2017.07.002","journal-title":"J Hand Surg Am"},{"issue":"6","key":"2320_CR34","doi-asserted-by":"publisher","first-page":"e13864","DOI":"10.1097\/MD.0000000000013864","volume":"98","author":"SH Kim","year":"2019","unstructured":"Kim SH, Lee SJ, Lee JW, Jeong HS, Suh IS (2019) Staged reconstruction of large skull defects with soft tissue infection after craniectomy using free flap and cranioplasty with a custom-made titanium mesh constructed by 3D-CT guided 3D printing technology. Medicine 98(6):e13864. https:\/\/doi.org\/10.1097\/MD.0000000000013864","journal-title":"Medicine"},{"issue":"10","key":"2320_CR35","doi-asserted-by":"publisher","first-page":"e341","DOI":"10.1016\/j.bjoms.2020.08.082","volume":"58","author":"A Gonzalez Alvarez","year":"2020","unstructured":"Gonzalez Alvarez A, Ananth S, Dovgalski L, Evans PL (2020) Custom three-dimensional printed orbital plate composed of two joined parts with variable thickness for a large orbital floor reconstruction after post-traumatic zygomatic fixation. Br J Oral Maxillofac Surg 58(10):e341\u2013e342. https:\/\/doi.org\/10.1016\/j.bjoms.2020.08.082","journal-title":"Br J Oral Maxillofac Surg"},{"key":"2320_CR36","doi-asserted-by":"publisher","first-page":"743","DOI":"10.1007\/s11517-012-0898-4","volume":"50","author":"L Ciocca","year":"2012","unstructured":"Ciocca L, Mazzoni S, Fantini M, Persiani F, Baldissara P, Marchetti C, Scotti R (2012) A CAD\/CAM-prototyped anatomical condylar prosthesis connected to a cumstom-made bone plate to support a fibula free flap. Med Biol Eng Comput 50:743\u2013749. https:\/\/doi.org\/10.1007\/s11517-012-0898-4","journal-title":"Med Biol Eng Comput"},{"issue":"1","key":"2320_CR37","doi-asserted-by":"publisher","first-page":"43","DOI":"10.1186\/s40902-019-0228-y","volume":"41","author":"M Takano","year":"2019","unstructured":"Takano M, Sugahara K, Koyachi M, Odaka K, Matsunaga S, Homma S, Abe S, Katakura A, Shibahara T (2019) Maxillary reconstruction using tunneling flap technique with 3D custom-made titanium mesh plate and particulate cancellous bone and marrow graft: a case report. Maxillofacial Plast Reconstr Surg 41(1):43. https:\/\/doi.org\/10.1186\/s40902-019-0228-y","journal-title":"Maxillofacial Plast Reconstr Surg"},{"key":"2320_CR38","doi-asserted-by":"publisher","first-page":"145","DOI":"10.1093\/icvts\/ivt456","volume":"18","author":"P Demondion","year":"2014","unstructured":"Demondion P, Mercier O, Kolb F, Fadel E (2014) Sternal replacement with a custom-made titanium plate after resection of a solitary breast cancer metastasis. Interact Cariovasc Thoracic Surg 18:145\u2013147. https:\/\/doi.org\/10.1093\/icvts\/ivt456","journal-title":"Interact Cariovasc Thoracic Surg"},{"key":"2320_CR39","doi-asserted-by":"publisher","first-page":"451","DOI":"10.1186\/s12891-020-03370-7","volume":"21","author":"C Wang","year":"2020","unstructured":"Wang C, Chen Y, Wang L, Wang D, Gu C, Lin X, Liu H, Chen J, Wen X, Liu Y, Huang F, Yao L, Fan S, Huang W, Dong J (2020) Three-dimensional printing of patient-specific plates for the treatment of acetabular fractures involving quadrilateral plate disruption. BMC Musculoskeletal Disord 21:451. https:\/\/doi.org\/10.1186\/s12891-020-03370-7","journal-title":"BMC Musculoskeletal Disord"},{"issue":"4","key":"2320_CR40","doi-asserted-by":"publisher","first-page":"507","DOI":"10.1007\/s11548-017-1682-6","volume":"113","author":"G Caiti","year":"2019","unstructured":"Caiti G, Dobbe JGG, Strackee SD, Strijkers GJ, Streekstra GJ (2019) Positioning error of custom 3D printed surgical guides for the radius: influence of fitting location and guide design. Int J Comput Assist Radiol Surg 113(4):507\u2013518. https:\/\/doi.org\/10.1007\/s11548-017-1682-6","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"6","key":"2320_CR41","doi-asserted-by":"publisher","first-page":"447","DOI":"10.1016\/j.jhsa.2017.03.024","volume":"42","author":"DE Bauer","year":"2017","unstructured":"Bauer DE, Zimmermann S, Aichmair A, Hingsammer A, Schweizer A, Nagy L, F\u00fcrnstahl P (2017) Conventional versus computer-assisted corrective osteotomy of the forearm: a retrospective analysis of 56 consecutive cases. J Hand Surg 42(6):447\u2013455. https:\/\/doi.org\/10.1016\/j.jhsa.2017.03.024","journal-title":"J Hand Surg"},{"issue":"5","key":"2320_CR42","doi-asserted-by":"publisher","first-page":"1099","DOI":"10.1007\/s11517-018-1945-6","volume":"57","author":"G Caiti","year":"2019","unstructured":"Caiti G, Dobbe JGG, Bervoets E, Beerens M, Strackee SD, Strijkers GJ, Streekstra GJ (2019) Biomechanical considerations in the design of patient-specific fixation plates for the distal radius. Med Biol Eng Comput 57(5):1099\u20131107. https:\/\/doi.org\/10.1007\/s11517-018-1945-6","journal-title":"Med Biol Eng Comput"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02320-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/article\/10.1007\/s11548-021-02320-5\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"http:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02320-5.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,3,10]],"date-time":"2021-03-10T05:22:55Z","timestamp":1615353775000},"score":1,"resource":{"primary":{"URL":"http:\/\/link.springer.com\/10.1007\/s11548-021-02320-5"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,2,11]]},"references-count":42,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,3]]}},"alternative-id":["2320"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02320-5","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,2,11]]},"assertion":[{"value":"4 September 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"26 January 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"11 February 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Compliance with ethical standards"}},{"value":"MB is CEO of Xilloc Medical.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Ethical approval to report this case series was obtained from our institutional review board (Date August 12, 2016, No. NL56144.018.16).","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Written informed consent was obtained from patients for their data to be published anonymously in this article.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}},{"value":"This study was performed in line with the principles of the Declaration of Helsinki.","order":5,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animal rights"}}]}}