{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,30]],"date-time":"2026-07-30T14:11:33Z","timestamp":1785420693271,"version":"3.56.0"},"reference-count":31,"publisher":"Springer Science and Business Media LLC","issue":"9","license":[{"start":{"date-parts":[[2021,4,2]],"date-time":"2021-04-02T00:00:00Z","timestamp":1617321600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,4,2]],"date-time":"2021-04-02T00:00:00Z","timestamp":1617321600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"name":"Federal State of Saxony-Anhalt (Germany), European Union","award":["ZS\/2016\/10\/81684"],"award-info":[{"award-number":["ZS\/2016\/10\/81684"]}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,9]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>\n                           <jats:bold>Purpose<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>Resection site repair during laparoscopic oncological surgery (e.g. laparoscopic partial nephrectomy) poses some unique challenges and opportunities for augmented reality (AR) navigation support. This work introduces an AR registration workflow that addresses the time pressure that is present during resection site repair.\n<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Methods<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>We propose a two-step registration process: the AR content is registered as accurately as possible prior to the tumour resection (the primary registration). This accurate registration is used to apply artificial fiducials to the physical organ and the virtual model. After the resection, these fiducials can be used for rapid re-registration (the secondary registration). We tested this pipeline in a simulated-use study with <jats:inline-formula><jats:alternatives><jats:tex-math>$$N=18$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mi>N<\/mml:mi>\n                      <mml:mo>=<\/mml:mo>\n                      <mml:mn>18<\/mml:mn>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> participants. We compared the registration accuracy and speed for our method and for landmark-based registration as a reference.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Results<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>Acquisition of and, thereby, registration with the artificial fiducials were significantly faster than the initial use of anatomical landmarks. Our method also had a trend to be more accurate in cases in which the primary registration was successful. The accuracy loss between the elaborate primary registration and the rapid secondary registration could be quantified with a mean target registration error increase of 2.35\u00a0mm.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Conclusion<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>This work introduces a registration pipeline for AR navigation support during laparoscopic resection site repair and provides a successful proof-of-concept evaluation thereof. Our results indicate that the concept is better suited than landmark-based registration during this phase, but further work is required to demonstrate clinical suitability and applicability.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-021-02336-x","type":"journal-article","created":{"date-parts":[[2021,4,2]],"date-time":"2021-04-02T07:02:26Z","timestamp":1617346946000},"page":"1577-1586","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Laparoscopic augmented reality registration for oncological resection site repair"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8105-9263","authenticated-orcid":false,"given":"Fabian","family":"Joeres","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2363-2460","authenticated-orcid":false,"given":"Tonia","family":"Mielke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5734-7529","authenticated-orcid":false,"given":"Christian","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,4,2]]},"reference":[{"issue":"3","key":"2336_CR1","doi-asserted-by":"publisher","first-page":"511","DOI":"10.1089\/end.2010.0249","volume":"25","author":"HO Altamar","year":"2011","unstructured":"Altamar HO, Ong RE, Glisson CL, Viprakasit DP, Miga MI, Herrell SD, Galloway RL (2011) Kidney deformation and intraprocedural registration: a study of elements of image-guided kidney surgery. J Endourol 25(3):511\u2013517. https:\/\/doi.org\/10.1089\/end.2010.0249","journal-title":"J Endourol"},{"issue":"5","key":"2336_CR2","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1109\/tpami.1987.4767965","volume":"9","author":"KS Arun","year":"1987","unstructured":"Arun KS, Huang TS, Blostein SD (1987) Least-squares fitting of two 3-d point sets. IEEE Trans Pattern Anal Mach Intell 9(5):698\u2013700. https:\/\/doi.org\/10.1109\/tpami.1987.4767965","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"2336_CR3","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.media.2017.01.007","volume":"37","author":"S Bernhardt","year":"2017","unstructured":"Bernhardt S, Nicolau S, Soler L, Doignon C (2017) The status of augmented reality in laparoscopic surgery as of 2016. Med Image Anal 37:66\u201390","journal-title":"Med Image Anal"},{"issue":"9","key":"2336_CR4","doi-asserted-by":"publisher","first-page":"2167","DOI":"10.1007\/s00345-019-02711-z","volume":"38","author":"R Bertolo","year":"2019","unstructured":"Bertolo R, Hung A, Porpiglia F, Bove P, Schleicher M, Dasgupta P (2019) Systematic review of augmented reality in urological interventions: the evidences of an impact on surgical outcomes are yet to come. World J Urol 38(9):2167\u20132176. https:\/\/doi.org\/10.1007\/s00345-019-02711-z","journal-title":"World J Urol"},{"issue":"2","key":"2336_CR5","doi-asserted-by":"publisher","first-page":"239","DOI":"10.1109\/34.121791","volume":"14","author":"PJ Besl","year":"1992","unstructured":"Besl PJ, McKay ND (1992) A method for registration of 3-D shapes. IEEE Trans Pattern Anal Mach Intell 14(2):239\u2013256. https:\/\/doi.org\/10.1109\/34.121791","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"key":"2336_CR6","first-page":"120","volume":"25","author":"G Bradski","year":"2000","unstructured":"Bradski G (2000) The OpenCV library. Dr. Dobb\u2019s J Softw Tools 25:120\u2013125","journal-title":"Dr. Dobb\u2019s J Softw Tools"},{"issue":"6","key":"2336_CR7","doi-asserted-by":"publisher","first-page":"1493","DOI":"10.1007\/s00345-013-1222-0","volume":"32","author":"Y Chen","year":"2014","unstructured":"Chen Y, Li H, Wu D, Bi K, Liu C (2014) Surgical planning and manual image fusion based on 3D model facilitate laparoscopic partial nephrectomy for intrarenal tumors. World J Urol 32(6):1493\u20131499. https:\/\/doi.org\/10.1007\/s00345-013-1222-0","journal-title":"World J Urol"},{"issue":"4","key":"2336_CR8","doi-asserted-by":"publisher","first-page":"e31","DOI":"10.1016\/j.jamcollsurg.2016.06.392","volume":"223","author":"C Conrad","year":"2016","unstructured":"Conrad C, Fusaglia M, Peterhans M, Lu H, Weber S, Gayet B (2016) Augmented reality navigation surgery facilitates laparoscopic rescue of failed portal vein embolization. J Am Coll Surg 223(4):e31-4. https:\/\/doi.org\/10.1016\/j.jamcollsurg.2016.06.392","journal-title":"J Am Coll Surg"},{"key":"2336_CR9","doi-asserted-by":"publisher","unstructured":"Detmer F.J, Hettig J, Schindele D, Schostak M, Hansen C (2017) Virtual and augmented reality systems for renal interventions: a systematic review. IEEE Rev Biomed Eng. https:\/\/doi.org\/10.1109\/RBME.2017.2749527","DOI":"10.1109\/RBME.2017.2749527"},{"issue":"1","key":"2336_CR10","doi-asserted-by":"publisher","first-page":"95","DOI":"10.1016\/j.media.2015.04.008","volume":"25","author":"P Edgcumbe","year":"2015","unstructured":"Edgcumbe P, Pratt P, Yang GZ, Nguan C, Rohling R (2015) Pico Lantern: Surface reconstruction and augmented reality in laparoscopic surgery using a pick-up laser projector. Med Image Anal 25(1):95\u2013102. https:\/\/doi.org\/10.1016\/j.media.2015.04.008","journal-title":"Med Image Anal"},{"issue":"12","key":"2336_CR11","doi-asserted-by":"publisher","first-page":"1081","DOI":"10.1016\/j.ijom.2006.09.015","volume":"35","author":"G Eggers","year":"2006","unstructured":"Eggers G, M\u00fchling J, Marmulla R (2006) Image-to-patient registration techniques in head surgery. Int J Oral Maxillofac Surg 35(12):1081\u20131095. https:\/\/doi.org\/10.1016\/j.ijom.2006.09.015","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"9","key":"2336_CR12","doi-asserted-by":"publisher","first-page":"1323","DOI":"10.1016\/j.mri.2012.05.001","volume":"30","author":"A Fedorov","year":"2012","unstructured":"Fedorov A, Beichel R, Kalpathy-Cramer J, Finet J, Fillion-Robin JC, Pujol S, Bauer C, Jennings D, Fennessy F, Sonka M, Buatti J, Aylward S, Miller JV, Pieper S, Kikinis R (2012) 3D slicer as an image computing platform for the quantitative imaging network. Magn Reson Imaging 30(9):1323\u20131341. https:\/\/doi.org\/10.1016\/j.mri.2012.05.001","journal-title":"Magn Reson Imaging"},{"issue":"6","key":"2336_CR13","doi-asserted-by":"publisher","first-page":"2280","DOI":"10.1016\/j.patcog.2014.01.005","volume":"47","author":"S Garrido-Jurado","year":"2014","unstructured":"Garrido-Jurado S, Mu\u00f1oz-Salinas R, Madrid-Cuevas FJ, Mar\u00edn-Jim\u00e9nez MJ (2014) Automatic generation and detection of highly reliable fiducial markers under occlusion. Pattern Recogn 47(6):2280\u20132292. https:\/\/doi.org\/10.1016\/j.patcog.2014.01.005","journal-title":"Pattern Recogn"},{"issue":"2","key":"2336_CR14","doi-asserted-by":"publisher","first-page":"483","DOI":"10.1016\/S0022-5347(05)63939-0","volume":"169","author":"B Guillonneau","year":"2003","unstructured":"Guillonneau B, Berm\u00fadez H, Gholami S, El Fettouh H, Gupta R, Adorno Rosa J, Baumert H, Cathelineau X, Fromont G, Vallancien G (2003) Laparoscopic partial nephrectomy for reanl tumor: single center experience comparing clamping and no clamping techniques of the renal vasculature. J Urol 169(2):483\u2013486. https:\/\/doi.org\/10.1016\/S0022-5347(05)63939-0","journal-title":"J Urol"},{"key":"2336_CR15","doi-asserted-by":"publisher","DOI":"10.1007\/978-1-84628-789-3","volume-title":"Laparoscopic techniques in uro-oncology","author":"B Guillonneau","year":"2009","unstructured":"Guillonneau B, Gill IS, Janetschek G, Tuerk IA (2009) Laparoscopic techniques in uro-oncology. Springer, London"},{"issue":"8","key":"2336_CR16","doi-asserted-by":"publisher","first-page":"1887","DOI":"10.1007\/s00268-010-0561-x","volume":"34","author":"O Heizmann","year":"2010","unstructured":"Heizmann O, Zidowitz S, Bourquain H, Potthast S, Peitgen HO, Oertli D, Kettelhack C (2010) Assessment of intraoperative liver deformation during hepatic resection: prospective clinical study. World J Surg 34(8):1887\u20131893. https:\/\/doi.org\/10.1007\/s00268-010-0561-x","journal-title":"World J Surg"},{"key":"2336_CR17","unstructured":"Heller N, Sathianathen N, Kalapara A, Walczak E, Moore K, Kaluzniak H, Rosenberg J, Blake P, Rengel Z, Oestreich M, Dean J, Tradewell M, Shah A, Tejpaul R, Edgerton Z, Peterson M, Raza S, Regmi S, Papanikolopoulos N, Weight C. The KiTS19 challenge data: 300 kidney tumor cases with clinical context, CT semantic segmentations, and surgical outcomes. http:\/\/arxiv.org\/pdf\/1904.00445v1"},{"issue":"7","key":"2336_CR18","doi-asserted-by":"publisher","first-page":"e0219920","DOI":"10.1371\/journal.pone.0219920","volume":"14","author":"F Joeres","year":"2019","unstructured":"Joeres F, Schindele D, Luz M, Blaschke S, Russwinkel N, Schostak M, Hansen C (2019) How well do software assistants for minimally invasive partial nephrectomy meet surgeon information needs? A cognitive task analysis and literature review study. PLoS ONE 14(7):e0219920. https:\/\/doi.org\/10.1371\/journal.pone.0219920","journal-title":"PLoS ONE"},{"issue":"3","key":"2336_CR19","doi-asserted-by":"publisher","first-page":"553","DOI":"10.1016\/j.eururo.2012.05.021","volume":"62","author":"JH Kaouk","year":"2012","unstructured":"Kaouk JH, Khalifeh A, Hillyer S, Haber GP, Stein RJ, Autorino R (2012) Robot-assisted laparoscopic partial nephrectomy: step-by-step contemporary technique and surgical outcomes at a single high-volume institution. Eur Urol 62(3):553\u2013561. https:\/\/doi.org\/10.1016\/j.eururo.2012.05.021","journal-title":"Eur Urol"},{"issue":"7","key":"2336_CR20","doi-asserted-by":"publisher","first-page":"2863","DOI":"10.1007\/s00464-016-5297-8","volume":"31","author":"SH Kong","year":"2017","unstructured":"Kong SH, Haouchine N, Soares R, Klymchenko A, Andreiuk B, Marques B, Shabat G, Piechaud T, Diana M, Cotin S, Marescaux J (2017) Robust augmented reality registration method for localization of solid organs\u2019 tumors using CT-derived virtual biomechanical model and fluorescent fiducials. Surg Endosc 31(7):2863\u20132871. https:\/\/doi.org\/10.1007\/s00464-016-5297-8","journal-title":"Surg Endosc"},{"key":"2336_CR21","doi-asserted-by":"publisher","unstructured":"Ong RE, Herrell III SD, Miga MI, Galloway JL (2008) A kidney deformation model for use in non-rigid registration during image-guided surgery. In: Miga MI, Cleary KR (eds) Medical imaging 2008: visualization, image-guided procedures, and modeling. SPIE Proceedings, p 69180W. SPIE. https:\/\/doi.org\/10.1117\/12.771669","DOI":"10.1117\/12.771669"},{"issue":"1","key":"2336_CR22","doi-asserted-by":"publisher","first-page":"23","DOI":"10.1007\/s11701-011-0334-z","volume":"6","author":"P Pratt","year":"2012","unstructured":"Pratt P, Mayer E, Vale J, Cohen D, Edwards E, Darzi A, Yang GZ (2012) An effective visualisation and registration system for image-guided robotic partial nephrectomy. J Robot Surg 6(1):23\u201331. https:\/\/doi.org\/10.1007\/s11701-011-0334-z","journal-title":"J Robot Surg"},{"issue":"3","key":"2336_CR23","doi-asserted-by":"publisher","first-page":"272","DOI":"10.1016\/S1072-7515(00)00339-2","volume":"191","author":"DJ Scott","year":"2000","unstructured":"Scott DJ, Bergen PC, Rege RV, Laycock R, Tesfay ST, Valentine R, Euhus DM, Jeyarajah D, Thompson WM, Jones DB (2000) Laparoscopic training on bench models: better and more cost effective than operating room experience? J Am Coll Surg 191(3):272\u2013283. https:\/\/doi.org\/10.1016\/S1072-7515(00)00339-2","journal-title":"J Am Coll Surg"},{"issue":"5","key":"2336_CR24","doi-asserted-by":"publisher","first-page":"541","DOI":"10.1007\/s11548-014-1075-z","volume":"10","author":"ND Serej","year":"2015","unstructured":"Serej ND, Ahmadian A, Mohagheghi S, Sadrehosseini SM (2015) A projected landmark method for reduction of registration error in image-guided surgery systems. Int J Comput Assist Radiol Surg 10(5):541\u2013554. https:\/\/doi.org\/10.1007\/s11548-014-1075-z","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"5","key":"2336_CR25","doi-asserted-by":"publisher","first-page":"204","DOI":"10.1049\/htl.2017.0063","volume":"4","author":"R Singla","year":"2017","unstructured":"Singla R, Edgcumbe P, Pratt P, Nguan C, Rohling R (2017) Intra-operative ultrasound-based augmented reality guidance for laparoscopic surgery. Healthc Technol Lett 4(5):204\u2013209. https:\/\/doi.org\/10.1049\/htl.2017.0063","journal-title":"Healthc Technol Lett"},{"key":"2336_CR26","doi-asserted-by":"publisher","unstructured":"Stolka PJ, Keil M, Sakas G, McVeigh E, Allaf ME, Taylor RH, Boctor EM (2010) A 3D-elastography-guided system for laparoscopic partial nephrectomies. In: SPIE Proceedings, p 76251I. SPIE . https:\/\/doi.org\/10.1117\/12.844589","DOI":"10.1117\/12.844589"},{"issue":"4","key":"2336_CR27","doi-asserted-by":"publisher","first-page":"195","DOI":"10.3109\/10929080109146083","volume":"6","author":"N Sugano","year":"2001","unstructured":"Sugano N, Sasama T, Sato Y, Nakajima Y, Nishii T, Yonenobu K, Tamura S, Ochi T (2001) Accuracy evaluation of surface-based registration methods in a computer navigation system for hip surgery performed through a posterolateral approach. Comput Aided Surg 6(4):195\u2013203. https:\/\/doi.org\/10.3109\/10929080109146083","journal-title":"Comput Aided Surg"},{"issue":"3","key":"2336_CR28","doi-asserted-by":"publisher","first-page":"340","DOI":"10.1016\/j.eururo.2010.05.047","volume":"58","author":"RH Thompson","year":"2010","unstructured":"Thompson RH, Lane BR, Lohse CM, Leibovich BC, Fergany A, Frank I, Gill IS, Blute ML, Campbell SC (2010) Every minute counts when the renal hilum is clamped during partial nephrectomy. Eur Urol 58(3):340\u2013345. https:\/\/doi.org\/10.1016\/j.eururo.2010.05.047","journal-title":"Eur Urol"},{"issue":"6","key":"2336_CR29","doi-asserted-by":"publisher","first-page":"899","DOI":"10.1007\/s11548-016-1385-4","volume":"11","author":"E Wild","year":"2016","unstructured":"Wild E, Teber D, Schmid D, Simpfend\u00f6rfer T, M\u00fcller M, Baranski AC, Kenngott H, Kopka K, Maier-Hein L (2016) Robust augmented reality guidance with fluorescent markers in laparoscopic surgery. Int J Comput Assist Radiol Surg 11(6):899\u2013907. https:\/\/doi.org\/10.1007\/s11548-016-1385-4","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"8","key":"2336_CR30","doi-asserted-by":"publisher","first-page":"1285","DOI":"10.1007\/s11548-019-01974-6","volume":"14","author":"X Zhang","year":"2019","unstructured":"Zhang X, Wang J, Wang T, Ji X, Shen Y, Sun Z, Zhang X (2019) A markerless automatic deformable registration framework for augmented reality navigation of laparoscopy partial nephrectomy. Int J Comput Assist Radiol Surg 14(8):1285\u20131294. https:\/\/doi.org\/10.1007\/s11548-019-01974-6","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2336_CR31","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1109\/34.888718","volume":"22","author":"Z Zhang","year":"2000","unstructured":"Zhang Z (2000) A flexible new technique for camera calibration. IEEE Trans Pattern Anal Mach Intell 22:1330\u20131334","journal-title":"IEEE Trans Pattern Anal Mach Intell"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02336-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-021-02336-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02336-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,8,10]],"date-time":"2021-08-10T12:20:25Z","timestamp":1628598025000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-021-02336-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,4,2]]},"references-count":31,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2021,9]]}},"alternative-id":["2336"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02336-x","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,4,2]]},"assertion":[{"value":"29 October 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 February 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"2 April 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}