{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,18]],"date-time":"2026-07-18T14:49:54Z","timestamp":1784386194134,"version":"3.55.0"},"reference-count":28,"publisher":"Springer Science and Business Media LLC","issue":"6","license":[{"start":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T00:00:00Z","timestamp":1620000000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T00:00:00Z","timestamp":1620000000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["51575343"],"award-info":[{"award-number":["51575343"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,6]]},"DOI":"10.1007\/s11548-021-02385-2","type":"journal-article","created":{"date-parts":[[2021,5,3]],"date-time":"2021-05-03T21:13:31Z","timestamp":1620076411000},"page":"1015-1025","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":14,"title":["Automatic ultrasound scanning robotic system with optical waveguide-based force measurement"],"prefix":"10.1007","volume":"16","author":[{"given":"Shihang","family":"Chen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhaojun","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yanping","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Qixin","family":"Cao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,5,3]]},"reference":[{"issue":"1","key":"2385_CR1","doi-asserted-by":"publisher","first-page":"89","DOI":"10.1016\/j.jrras.2017.11.005","volume":"11","author":"MZ Mahmoud","year":"2019","unstructured":"Mahmoud MZ, Aslam M, Alsaadi M, Fagiri MA, Alonazi B (2019) Evolution of robot-assisted ultrasound-guided breast biopsy systems. J Radiat Res Appl Sci 11(1):89\u201397","journal-title":"J Radiat Res Appl Sci"},{"issue":"4","key":"2385_CR2","doi-asserted-by":"publisher","first-page":"799","DOI":"10.1109\/TBME.2009.2030169","volume":"57","author":"Z Neubach","year":"2010","unstructured":"Neubach Z, Shoham M (2010) Ultrasound-guided robot for flexible needle steering. IEEE Trans Biomed Eng 57(4):799\u2013805","journal-title":"IEEE Trans Biomed Eng"},{"issue":"11","key":"2385_CR3","doi-asserted-by":"publisher","first-page":"112903","DOI":"10.1118\/1.4824326","volume":"40","author":"H Neshat","year":"2013","unstructured":"Neshat H, Cool DW, Barker K, Gardi L, Kakani N, Fenster A (2013) A 3D ultrasound scanning system for image guided liver interventions. Med Phys 40(11):112903","journal-title":"Med Phys"},{"key":"2385_CR4","doi-asserted-by":"publisher","DOI":"10.1155\/2017\/6027029","author":"Q Huang","year":"2017","unstructured":"Huang Q, Zeng Z (2017) A review on real-time 3D ultrasound imaging technology. Biomed Res Int. https:\/\/doi.org\/10.1155\/2017\/6027029","journal-title":"Biomed Res Int"},{"issue":"2","key":"2385_CR5","first-page":"125","volume":"97","author":"FM Agel","year":"2005","unstructured":"Agel FM, Lorenzo MJV (2005) Tridimensional (3D) ultrasonography. Rev Esp Enferm Dig 97(2):125\u2013134","journal-title":"Rev Esp Enferm Dig"},{"issue":"4","key":"2385_CR6","first-page":"501","volume":"18","author":"A Saftoiu","year":"2009","unstructured":"Saftoiu A, Gheonea DI (2009) Tridimensional (3D) endoscopic ultrasound\u2014a pictorial review. J Gastrointest Liver Dis 18(4):501\u2013505","journal-title":"J Gastrointest Liver Dis"},{"issue":"4","key":"2385_CR7","doi-asserted-by":"publisher","first-page":"143","DOI":"10.1016\/j.ultrasmedbio.2004.11.001","volume":"31","author":"L Mercier","year":"2005","unstructured":"Mercier L, Lang\u00f8 T, Lindseth F, Collins DL (2005) A review of calibration techniques for freehand 3-D ultrasound systems. Ultrasound Med Biol 31(4):143\u2013165","journal-title":"Ultrasound Med Biol"},{"issue":"3","key":"2385_CR8","doi-asserted-by":"publisher","first-page":"256","DOI":"10.1002\/rcs.313","volume":"6","author":"J Xu","year":"2010","unstructured":"Xu J, Jia ZZ, Song ZJ, Yang XD, Chen K, Liang P (2010) Three-dimensional ultrasound image-guided robotic system for accurate microwave coagulation of malignant liver tumours. Int J Med Robot Comput Assist Surg 6(3):256\u2013268","journal-title":"Int J Med Robot Comput Assist Surg"},{"issue":"4","key":"2385_CR9","first-page":"491","volume":"15","author":"PK Seitz","year":"2019","unstructured":"Seitz PK, Baumann B, Johnen W, Lissek C, Seidel J, Bendl R (2019) Development of a robot-assisted ultrasound-guided radiation therapy (USgRT). Int J Comput Assist Radiol Surg 15(4):491\u2013501","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"4","key":"2385_CR10","doi-asserted-by":"publisher","first-page":"835","DOI":"10.1109\/TRO.2015.2429051","volume":"31","author":"MW Gilbertson","year":"2015","unstructured":"Gilbertson MW, Anthony BW (2015) Force and position control system for freehand ultrasound. IEEE Trans Robot 31(4):835\u2013849","journal-title":"IEEE Trans Robot"},{"issue":"8","key":"2385_CR11","doi-asserted-by":"publisher","first-page":"4229","DOI":"10.1007\/s13369-017-2893-4","volume":"43","author":"ME Karar","year":"2018","unstructured":"Karar ME (2018) A simulation study of adaptive force controller for medical robotic liver ultrasound guidance. Arab J Sci Eng 43(8):4229\u20134238","journal-title":"Arab J Sci Eng"},{"issue":"6","key":"2385_CR12","doi-asserted-by":"publisher","first-page":"2365","DOI":"10.1109\/TII.2016.2576960","volume":"12","author":"K Lau","year":"2016","unstructured":"Lau K, Leun EYY, Chiu PWY, Yam Y, Lau JYW, Poon CCY (2016) A flexible surgical robotic system for removal of early-stage gastrointestinal cancers by endoscopic submucosal dissection. IEEE Trans Ind Inform 12(6):2365\u20132374","journal-title":"IEEE Trans Ind Inform"},{"issue":"6","key":"2385_CR13","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1007\/s11548-016-1408-1","volume":"11","author":"R Kojcev","year":"2016","unstructured":"Kojcev R, Fuerst B, Zettinig O, Fotouhi J, Lee SC, Frisch B, Taylor R, Sinibaldi E, Navab N (2016) Dual-robot ultrasound-guided needle placement: closing the planning-imaging-action loop. Int J Comput Assist Radiol Surg 11(6):1173\u20131181","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2385_CR14","doi-asserted-by":"publisher","DOI":"10.1109\/TIE.2020.3036215","author":"Z Jiang","year":"2020","unstructured":"Jiang Z, Grimm M, Zhou M, Hu Y, Esteban J, Navab N (2020) Automatic force-based probe positioning for precise robotic ultrasound acquisition. IEEE Trans Ind Electron. https:\/\/doi.org\/10.1109\/TIE.2020.3036215","journal-title":"IEEE Trans Ind Electron"},{"issue":"2","key":"2385_CR15","doi-asserted-by":"publisher","first-page":"1342","DOI":"10.1109\/LRA.2020.2967682","volume":"5","author":"Z Jiang","year":"2020","unstructured":"Jiang Z, Grimm M, Zhou M, Esteban J, Simson W, Zahnd G, Navab N (2020) Automatic normal positioning of robotic ultrasound probe based only on confidence map optimization and force measurement. IEEE Robot Autom Lett 5(2):1342\u20131349","journal-title":"IEEE Robot Autom Lett"},{"key":"2385_CR16","doi-asserted-by":"crossref","unstructured":"Wu B, Huang Q (2016) A Kinect-based automatic ultrasound scanning system. In: International conference on advanced robotics and mechatronics (ICARM), pp 585\u2013590","DOI":"10.1109\/ICARM.2016.7606986"},{"issue":"5","key":"2385_CR17","doi-asserted-by":"publisher","first-page":"619","DOI":"10.1007\/s11548-018-1716-8","volume":"13","author":"S Virga","year":"2018","unstructured":"Virga S, Gobl R, Baust M, Navab N, Hennersperger C (2018) Use the force: deformation correction in robotic 3D ultrasound. Int J Comput Assist Radiol Surg 13(5):619\u2013627","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"2385_CR18","doi-asserted-by":"publisher","first-page":"895","DOI":"10.1007\/s11548-018-1759-x","volume":"13","author":"J Esteban","year":"2018","unstructured":"Esteban J, Simson W, Requena Witzig S, Rienm\u00fcller A, Virga S, Frisch B, Zettinig O, Sakara D, Ryang Y, Navab N, Hennersperger C (2018) Robotic ultrasound-guided facet joint insertion. Int J Comput Assist Radiol Surg 13(1):895\u2013904","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"2385_CR19","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1109\/TUFFC.2015.2499084","volume":"63","author":"S Merouche","year":"2016","unstructured":"Merouche S, Allard L, Montagnon E, Soulez G, Bigras P, Cloutier G (2016) A robotic ultrasound scanner for automatic vessel tracking and three-dimensional reconstruction of B-mode images. IEEE Trans Ultrason Ferroelectr Freq Control 63(1):35\u201346","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"8","key":"2385_CR20","doi-asserted-by":"publisher","first-page":"1330","DOI":"10.1109\/TUFFC.2005.1509791","volume":"52","author":"MR Burcher","year":"2005","unstructured":"Burcher MR, Noble JA, Han L, Gooding M (2005) A system for simultaneously measuring contact force, ultrasound, and position information for use in force-based correction of freehand scanning. IEEE Trans Ultrason Ferroelectr Freq Control 52(8):1330\u20131342","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"2","key":"2385_CR21","doi-asserted-by":"publisher","first-page":"1173","DOI":"10.1109\/TII.2018.2871864","volume":"15","author":"Q Huang","year":"2019","unstructured":"Huang Q, Lan J, Li X (2019) Robotic arm based automatic ultrasound scanning for three-dimensional Imaging. IEEE Trans Ind Inform 15(2):1173\u20131182","journal-title":"IEEE Trans Ind Inform"},{"key":"2385_CR22","doi-asserted-by":"publisher","first-page":"677","DOI":"10.1016\/j.sna.2017.07.031","volume":"263","author":"E Fujiwara","year":"2017","unstructured":"Fujiwara E, Wu YT, Dos Santos MFM, Schenkel EA, Suzuki CK (2017) Development of a tactile sensor based on optical fiber specklegram analysis and sensor data fusion technique. Sens Actuator A-Phys 263:677\u2013686","journal-title":"Sens Actuator A-Phys"},{"issue":"10","key":"2385_CR23","doi-asserted-by":"publisher","first-page":"3631","DOI":"10.1109\/JSEN.2014.2330998","volume":"14","author":"E Fujiwara","year":"2014","unstructured":"Fujiwara E, Ferreira M, Dos Santos MFM, Suzuki CK (2014) Flexible optical fiber bending transducer for application in glove-based sensors. IEEE Sens J 14(10):3631\u20133636","journal-title":"IEEE Sens J"},{"issue":"1","key":"2385_CR24","doi-asserted-by":"publisher","first-page":"22","DOI":"10.1109\/JSEN.2011.2113394","volume":"12","author":"R Ahmadi","year":"2012","unstructured":"Ahmadi R, Packirisamy M, Dargahi J, Cecere R (2012) Discretely loaded beam-type optical fiber tactile sensor for tissue manipulation and palpation in minimally invasive robotic surgery. IEEE Sens J 12(1):22\u201332","journal-title":"IEEE Sens J"},{"key":"2385_CR25","doi-asserted-by":"crossref","unstructured":"Graumann C, Fuerst B, Hennersperger C, Bork F, Navab N (2016) Robotic ultrasound trajectory planning for volume of interest coverage. In: IEEE international conference on robotics and automation (ICRA), pp 736\u2013741","DOI":"10.1109\/ICRA.2016.7487201"},{"issue":"3","key":"2385_CR26","doi-asserted-by":"publisher","first-page":"348","DOI":"10.1002\/rcs.1420","volume":"8","author":"D Miller","year":"2012","unstructured":"Miller D, Lippert C, Vollmar V, Bozinov O, Benes L, Schulte DM, Sure U (2012) Comparison of different reconstruction algorithms for three dimensional ultrasound imaging in a neurosurgical setting. Int J Med Robot Comput Assist Surg 8(3):348\u2013359","journal-title":"Int J Med Robot Comput Assist Surg"},{"key":"2385_CR27","doi-asserted-by":"crossref","unstructured":"Gobbi DG, Peters TM (2002) Interactive intra-operative 3D ultrasound reconstruction and visualization. In: Proceedings of the international conference on medical image computing and computer-assisted intervention, pp 156\u2013163","DOI":"10.1007\/3-540-45787-9_20"},{"key":"2385_CR28","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-020-02300-1","author":"S Chen","year":"2021","unstructured":"Chen S, Wang F, Lin Y, Shi Q, Wang Y (2021) Ultrasound-guided needle insertion robotic system for percutaneous puncture. Int J Comput Assist Radiol Surg. https:\/\/doi.org\/10.1007\/s11548-020-02300-1","journal-title":"Int J Comput Assist Radiol Surg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02385-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-021-02385-2\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02385-2.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,5,31]],"date-time":"2021-05-31T10:54:26Z","timestamp":1622458466000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-021-02385-2"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5,3]]},"references-count":28,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2021,6]]}},"alternative-id":["2385"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02385-2","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,5,3]]},"assertion":[{"value":"25 December 2020","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 April 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"3 May 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. No animal experiments were performed in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animals rights"}},{"value":"Informed consent was obtained from all participants.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}