{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,1]],"date-time":"2026-06-01T20:00:05Z","timestamp":1780344005421,"version":"3.54.1"},"reference-count":36,"publisher":"Springer Science and Business Media LLC","issue":"12","license":[{"start":{"date-parts":[[2021,7,4]],"date-time":"2021-07-04T00:00:00Z","timestamp":1625356800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,7,4]],"date-time":"2021-07-04T00:00:00Z","timestamp":1625356800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001134","name":"Australia-India Strategic Research Fund","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001134","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,12]]},"DOI":"10.1007\/s11548-021-02444-8","type":"journal-article","created":{"date-parts":[[2021,7,4]],"date-time":"2021-07-04T04:02:15Z","timestamp":1625371335000},"page":"2137-2145","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Visual Localisation for Knee Arthroscopy"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2622-3301","authenticated-orcid":false,"given":"Artur","family":"Banach","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mario","family":"Strydom","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anjali","family":"Jaiprakash","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gustavo","family":"Carneiro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Anders","family":"Eriksson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ross","family":"Crawford","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aaron","family":"McFadyen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,7,4]]},"reference":[{"issue":"1","key":"2444_CR1","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1177\/2309499016684993","volume":"25","author":"A Jaiprakash","year":"2017","unstructured":"Jaiprakash A, O\u2019Callaghan WB, Whitehouse SL, Pandey A, Wu L, Roberts J, Crawford R (2017) Orthopaedic surgeon attitudes towards current limitations and the potential for robotic and technological innovation in arthroscopic surgery. J Orthop Surg 25(1):1\u20136","journal-title":"J Orthop Surg"},{"key":"2444_CR2","doi-asserted-by":"crossref","unstructured":"Banach A, Leibrandt K, Grammatikopoulou M, Yang G-Z (2019) Active contraints for tool-shaft collision avoidance in minimally invasive surgery. In: IEEE ICRA, pp\u00a01556\u20131562","DOI":"10.1109\/ICRA.2019.8794147"},{"key":"2444_CR3","doi-asserted-by":"crossref","unstructured":"Marmol A, Corke P, Peynot T (2018) ArthroSLAM : multi-sensor robust visual localization for minimally invasive orthopedic surgery. In: IEEE IROS","DOI":"10.1109\/IROS.2018.8593501"},{"issue":"3","key":"2444_CR4","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1109\/MRA.2006.1678144","volume":"13","author":"T Bailey","year":"2006","unstructured":"Bailey T, Durrant-Whyte H (2006) Simultaneous localization and mapping (SLAM): part I. IEEE Robot Autom Mag 13(3):108\u2013117","journal-title":"IEEE Robot Autom Mag"},{"issue":"September","key":"2444_CR5","doi-asserted-by":"publisher","first-page":"108","DOI":"10.1109\/MRA.2006.1678144","volume":"13","author":"T Bailey","year":"2006","unstructured":"Bailey T, Durrant-whyte H (2006) Simultaneous localization and mapping (SLAM): part II. IEEE Robot Autom Soc 13(September):108\u2013117","journal-title":"IEEE Robot Autom Soc"},{"issue":"6","key":"2444_CR6","first-page":"1309","volume":"32","author":"C Cadena","year":"2016","unstructured":"Cadena C, Carlone L, Carrillo H, Latif Y, Scaramuzza D, Reid I, Leonard JJ, Neira J, Reid I, Leonard JJ (2016) Past, present, and future of simultaneous localization and mapping: toward the robust-perception age. IEEE Trans 32(6):1309\u20131332","journal-title":"IEEE Trans"},{"issue":"8","key":"2444_CR7","doi-asserted-by":"publisher","first-page":"974","DOI":"10.1016\/j.media.2013.04.003","volume":"17","author":"L Maier-Hein","year":"2013","unstructured":"Maier-Hein L, Mountney P, Bartoli A, Elhawary H, Elson DS, Groch A, Kolb A, Rodrigues M, Sorger J, Speidel S, Stoyanov D (2013) Optical techniques for 3D surface reconstruction in computer-assisted laparoscopic surgery. Med Image Anal 17(8):974\u2013996","journal-title":"Med Image Anal"},{"key":"2444_CR8","doi-asserted-by":"crossref","unstructured":"Stoyanov D, Yang G-Z (2009) Soft tissue deformation tracking for robotic assisted minimally invasive surgery. In: Annual international conference of the IEEE engineering in medicine and biology society, pp.\u00a0254\u2013257, 2009","DOI":"10.1109\/IEMBS.2009.5334010"},{"issue":"1","key":"2444_CR9","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1007\/s11548-016-1444-x","volume":"12","author":"N Mahmoud","year":"2017","unstructured":"Mahmoud N, Grasa \u00d3G, Nicolau SA, Doignon C, Soler L, Marescaux J, Montiel JM (2017) On-patient see-through augmented reality based on visual SLAM. Int J Comput Assist Radiol Surg 12(1):1\u201311","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2444_CR10","doi-asserted-by":"publisher","first-page":"168382","DOI":"10.1109\/ACCESS.2019.2953471","volume":"7","author":"M Strydom","year":"2019","unstructured":"Strydom M, Crawford R, Roberts J, Jaiprakash A (2019) Robotic arthroscopy: the uncertainty in internal knee joint measurement. IEEE Access 7:168382\u2013168394","journal-title":"IEEE Access"},{"issue":"4","key":"2444_CR11","doi-asserted-by":"publisher","first-page":"2135","DOI":"10.1109\/LRA.2017.2714150","volume":"2","author":"A Marmol","year":"2017","unstructured":"Marmol A, Peynot T, Eriksson A, Jaiprakash A, Roberts J, Crawford R (2017) Evaluation of keypoint detectors and descriptors in arthroscopic images for feature-based matching applications. IEEE Robot Autom Lett 2(4):2135\u20132142","journal-title":"IEEE Robot Autom Lett"},{"issue":"2","key":"2444_CR12","doi-asserted-by":"publisher","first-page":"918","DOI":"10.1109\/LRA.2019.2892199","volume":"4","author":"A Marmol","year":"2019","unstructured":"Marmol A, Banach A, Peynot T (2019) Dense-ArthroSLAM: dense intra-articular 3-D reconstruction with robust localization prior for arthroscopy. IEEE Robot Autom Lett 4(2):918\u2013925","journal-title":"IEEE Robot Autom Lett"},{"issue":"5","key":"2444_CR13","doi-asserted-by":"publisher","first-page":"1255","DOI":"10.1109\/TRO.2017.2705103","volume":"33","author":"R Mur-Artal","year":"2017","unstructured":"Mur-Artal R, Tard\u00f3s JD (2017) Orb-slam2: an open-source slam system for monocular, stereo, and rgb-d cameras. IEEE Trans Robot 33(5):1255\u20131262","journal-title":"IEEE Trans Robot"},{"key":"2444_CR14","doi-asserted-by":"crossref","unstructured":"Engel J, Schops T, Cremers D (2014) LSD-SLAM: large-scale direct monocular SLAM. In: European conference on computer vision, pp\u00a0834\u2013849","DOI":"10.1007\/978-3-319-10605-2_54"},{"key":"2444_CR15","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1109\/ACCESS.2020.3040187","volume":"8","author":"A Banach","year":"2020","unstructured":"Banach A, Strydom M, Jaiprakash A, Carneiro G, Brown C, Crawford R, McFadyen A (2020) Saliency improvement in feature-poor surgical environments using local Laplacian of Specified Histograms. IEEE Access 8:1\u20131","journal-title":"IEEE Access"},{"key":"2444_CR16","unstructured":"Goodfellow I, Bengio Y, Courville A (2016) Deep learning: whole book. Nature"},{"issue":"12","key":"2444_CR17","doi-asserted-by":"publisher","first-page":"2572","DOI":"10.1109\/TMI.2018.2842767","volume":"37","author":"F Mahmood","year":"2018","unstructured":"Mahmood F, Chen R, Durr NJ (2018) Unsupervised reverse domain adaptation for synthetic medical images via adversarial training. IEEE Trans Med Imaging 37(12):2572\u20132581","journal-title":"IEEE Trans Med Imaging"},{"key":"2444_CR18","doi-asserted-by":"publisher","first-page":"1089","DOI":"10.1007\/s11548-017-1609-2","volume":"7","author":"M Visentini-scarzanella","year":"2017","unstructured":"Visentini-scarzanella M, Koto S, Sugiura T, Kaneko T (2017) Deep monocular 3D reconstruction for assisted navigation in bronchoscopy. Int J Comput Assist Radiol Surg 7:1089\u20131099","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2444_CR19","doi-asserted-by":"crossref","unstructured":"Hou B, Alansary A, McDonagh S, Davidson A, Rutherford M, Hajnal JV, Rueckert, Glocker DB, Kainz B (2017) Predicting slice-to-volume transformation in presence of arbitrary subject motion. In: International conference on medical image computing and computer-assisted intervention. Springer, pp\u00a0296\u2013304","DOI":"10.1007\/978-3-319-66185-8_34"},{"issue":"7","key":"2444_CR20","doi-asserted-by":"publisher","first-page":"1095","DOI":"10.1007\/s11548-020-02204-0","volume":"15","author":"L Kausch","year":"2020","unstructured":"Kausch L, Thomas S, Kunze H, Privalov M, Vetter S, Franke J, Mahnken AH, Maier-Hein L, Maier-Hein K (2020) Toward automatic c-arm positioning for standard projections in orthopedic surgery. Int J Comput Assist Radiol Surg 15(7):1095\u20131105","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2444_CR21","doi-asserted-by":"crossref","unstructured":"Sganga J, Eng D, Graetzel C, Camarillo D (2018) OffsetNet: deep learning for localization in the lung using rendered images. ArXiv e-prints","DOI":"10.1109\/ICRA.2019.8793940"},{"key":"2444_CR22","unstructured":"Sganga J, Eng D, Graetzel C, Camarillo DB (2019) Deep learning for localization in the lung. ArXiv e-prints"},{"key":"2444_CR23","unstructured":"Zhou T, Berkeley UC, Brown M, Snavely N, Lowe DG (1851) Unsupervised learning of depth and ego-motion from video, pp\u00a01851\u20131860"},{"key":"2444_CR24","doi-asserted-by":"crossref","unstructured":"Wang R, Pizer SM, Frahm JM (2019) Recurrent neural network for (un-)supervised learning of monocular video visual odometry and depth. In: Proceedings of the IEEE computer society conference on computer vision and pattern recognition, 2019","DOI":"10.1109\/CVPR.2019.00570"},{"key":"2444_CR25","doi-asserted-by":"crossref","unstructured":"Kendall A, Cipolla R (2015) PoseNet: a convolutional network for real-time 6-DOF camera relocalization. In: International conference on computer vision, pp\u00a02938\u20132946","DOI":"10.1109\/ICCV.2015.336"},{"key":"2444_CR26","doi-asserted-by":"crossref","unstructured":"Strydom M, Banach A, Wu L, Jaiprakash A, Crawford R, Roberts J (2020) Anatomical joint measurement with application to medical robotics. IEEE Access","DOI":"10.1109\/ACCESS.2020.3002541"},{"key":"2444_CR27","doi-asserted-by":"crossref","unstructured":"Strydom ML, Banach A, Roberts J, Crawford R, Jaiprakash AT (2020) Kinematic model of the human leg using dh parameters. IEEE Access 8:191737\u2013191750","DOI":"10.1109\/ACCESS.2020.3031295"},{"key":"2444_CR28","doi-asserted-by":"crossref","unstructured":"Wengert C, Reeff M, Cattin PC, Sz\u00e9kely G (2006) Fully automatic endoscope calibration for intraoperative use. In: Bildverarbeitung f\u00fcr die Medizin 2006","DOI":"10.1007\/3-540-32137-3_85"},{"key":"2444_CR29","unstructured":"Bouguet J-Y (2002) Camera calibration toolbox for matlab"},{"key":"2444_CR30","unstructured":"Abadi M, Barham P, Chen J, Chen Z, Davis A, Jeffrey D, Devin M, Ghemawat S, Irving G, Isard M, Kudlur M, Levenberg V, Monga R, Moore S, Murray D, Steiner B, Tucker P, Vasudevan V, Warden P, Wicke M, Yu Y, Zheng X (2016) TensorFlow: a system for large-scale machine learning. In: Proceedings of the 12th USENIX conference on operator system design and implementation, 2016"},{"key":"2444_CR31","doi-asserted-by":"crossref","unstructured":"Mayo B, Hazan T, Tal A (2021) Visual navigation with spatial attention. arXiv preprint arXiv:2104.09807","DOI":"10.1109\/CVPR46437.2021.01662"},{"issue":"2","key":"2444_CR32","doi-asserted-by":"publisher","first-page":"732","DOI":"10.1109\/LRA.2019.2893419","volume":"4","author":"M Shen","year":"2019","unstructured":"Shen M, Gu Y, Liu N, Yang GZ (2019) Context-aware depth and pose estimation for bronchoscopic navigation. IEEE Robot Autom Lett 4(2):732\u2013739","journal-title":"IEEE Robot Autom Lett"},{"issue":"2","key":"2444_CR33","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1016\/S0021-9290(98)00158-4","volume":"32","author":"T-W Lu","year":"1999","unstructured":"Lu T-W, O\u2019connor J (1999) Bone position estimation from skin marker co-ordinates using global optimisation with joint constraints. J Biomech 32(2):129\u2013134","journal-title":"J Biomech"},{"issue":"2","key":"2444_CR34","doi-asserted-by":"publisher","first-page":"213","DOI":"10.1016\/j.gaitpost.2003.09.004","volume":"20","author":"IW Charlton","year":"2004","unstructured":"Charlton IW, Tate P, Smyth P, Roren L (2004) Repeatability of an optimised lower body model. Gait Posture 20(2):213\u2013221","journal-title":"Gait Posture"},{"issue":"4","key":"2444_CR35","first-page":"347","volume":"99","author":"B Carse","year":"2013","unstructured":"Carse B, Meadows B, Bowers R, Rowe P (2013) Affordable clinical gait analysis: an assessment of the marker tracking accuracy of a new low-cost optical 3D motion analysis system. Physiotherapy (United Kingdom) 99(4):347\u2013351","journal-title":"Physiotherapy (United Kingdom)"},{"key":"2444_CR36","doi-asserted-by":"publisher","first-page":"13","DOI":"10.1007\/978-3-030-16593-2_2","volume-title":"Robotics in knee and hip arthroplasty","author":"MW Allen","year":"2019","unstructured":"Allen MW, Jacofsky DJ (2019) Evolution of robotics in arthroplasty. In: Lonner JH (ed) Robotics in knee and hip arthroplasty. Springer, Berlin, pp 13\u201325"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02444-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-021-02444-8\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02444-8.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2023,1,2]],"date-time":"2023-01-02T18:35:25Z","timestamp":1672684525000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-021-02444-8"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7,4]]},"references-count":36,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2021,12]]}},"alternative-id":["2444"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02444-8","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,7,4]]},"assertion":[{"value":"13 January 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"28 June 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"4 July 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The dataset collected for this work will be made publicly available upon acceptance.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Availability of data and material"}},{"value":"The authors (AB, MS, AJ, GC, AE, RC, AM) do not report any conflict of interest.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"Cadaveric experiments were approved by the Australian National Health and Medical Research Council (NHMRC) - Committee no. EC00171.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}}]}}