{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T19:07:55Z","timestamp":1781550475191,"version":"3.54.5"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"10","license":[{"start":{"date-parts":[[2021,10,1]],"date-time":"2021-10-01T00:00:00Z","timestamp":1633046400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2021,10,15]],"date-time":"2021-10-15T00:00:00Z","timestamp":1634256000000},"content-version":"vor","delay-in-days":14,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100012320","name":"Otto-von-Guericke-Universit\u00e4t Magdeburg","doi-asserted-by":"crossref","id":[{"id":"10.13039\/501100012320","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2021,10]]},"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Percutaneous needle insertion is one of the most common minimally invasive procedures. The clinician\u2019s experience and medical imaging support are essential to the procedure\u2019s safety. However, imaging comes with inaccuracies due to artifacts, and therefore sensor-based solutions were proposed to improve accuracy. However, sensors are usually embedded in the needle tip, leading to design limitations. A novel concept was proposed for capturing tip\u2013tissue interaction information through audio sensing, showing promising results for needle guidance. This work demonstrates that this audio approach can provide important puncture information by comparing audio and force signal dynamics during insertion.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>An experimental setup for inserting a needle into soft tissue was prepared. Audio and force signals were synchronously recorded at four different insertion velocities, and a dataset of 200 recordings was acquired. Indicators related to different aspects of the force and audio were compared through signal-to-signal and event-to-event correlation analysis.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>High signal-to-signal correlations between force and audio indicators regardless of the insertion velocity were obtained. The force curvature indicator obtained the best correlation performances to audio with more than <jats:inline-formula><jats:alternatives><jats:tex-math>$$70\\%$$<\/jats:tex-math><mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                    <mml:mrow>\n                      <mml:mn>70<\/mml:mn>\n                      <mml:mo>%<\/mml:mo>\n                    <\/mml:mrow>\n                  <\/mml:math><\/jats:alternatives><\/jats:inline-formula> of the correlations higher than 0.6. The event-to-event correlation analysis shows that a puncture event in the force is generally identifiable in audio and that their intensities firmly related.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusions<\/jats:title>\n                <jats:p>Audio contains valuable information for monitoring needle tip\/tissue interaction. Significant dynamics obtained from a well-known sensor as force can also be extracted from audio, regardless of insertion velocities.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-021-02479-x","type":"journal-article","created":{"date-parts":[[2021,10,15]],"date-time":"2021-10-15T15:10:01Z","timestamp":1634310601000},"page":"1683-1697","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":7,"title":["Study of needle punctures into soft tissue through audio and force sensing: can audio be a simple alternative for needle guidance?"],"prefix":"10.1007","volume":"16","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7009-9929","authenticated-orcid":false,"given":"Muhannad","family":"Sabieleish","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8104-7828","authenticated-orcid":false,"given":"Katarzyna","family":"Heryan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5874-7145","authenticated-orcid":false,"given":"Axel","family":"Boese","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5734-7529","authenticated-orcid":false,"given":"Christian","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8624-0800","authenticated-orcid":false,"given":"Michael","family":"Friebe","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0118-0483","authenticated-orcid":false,"given":"Alfredo","family":"Illanes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2021,10,15]]},"reference":[{"key":"2479_CR1","doi-asserted-by":"crossref","unstructured":"Abayazid M, Kemp M, Misra S (2013) 3d flexible needle steering in soft-tissue phantoms using fiber bragg grating sensors. In: 2013 IEEE international conference on robotics and automation, IEEE, pp 5843\u20135849","DOI":"10.1109\/ICRA.2013.6631418"},{"issue":"4","key":"2479_CR2","doi-asserted-by":"publisher","first-page":"413","DOI":"10.1016\/j.medengphy.2006.07.003","volume":"29","author":"N Abolhassani","year":"2007","unstructured":"Abolhassani N, Patel R, Moallem M (2007) Needle insertion into soft tissue: a survey. Med Eng Phys 29(4):413\u2013431","journal-title":"Med Eng Phys"},{"key":"2479_CR3","doi-asserted-by":"crossref","unstructured":"Barnett AC, Lee YS, Moore JZ (2016) Fracture mechanics model of needle cutting tissue. J Manuf Sci Eng. 138(1): 011005","DOI":"10.1115\/1.4030374"},{"key":"2479_CR4","doi-asserted-by":"crossref","unstructured":"Chadda R, Wismath S, Hessinger M, Sch\u00e4fer N, Schlaefer A, Kupnik M (2019) Needle tip force sensor for medical applications. In: 2019 IEEE SENSORS, IEEE, pp 1\u20134","DOI":"10.1109\/SENSORS43011.2019.8956754"},{"key":"2479_CR5","doi-asserted-by":"crossref","unstructured":"Elayaperumal S, Bae JH, Daniel BL, Cutkosky MR (2014) Detection of membrane puncture with haptic feedback using a tip-force sensing needle. In: 2014 IEEE\/RSJ international conference on intelligent robots and systems, IEEE, pp 3975\u20133981","DOI":"10.1109\/IROS.2014.6943121"},{"issue":"6","key":"2479_CR6","doi-asserted-by":"publisher","first-page":"665","DOI":"10.1016\/j.medengphy.2012.04.007","volume":"34","author":"DJ van Gerwen","year":"2012","unstructured":"van Gerwen DJ, Dankelman J, van den Dobbelsteen JJ (2012) Needle-tissue interaction forces\u2014a survey of experimental data. Med Eng Phys 34(6):665\u2013680","journal-title":"Med Eng Phys"},{"issue":"6","key":"2479_CR7","doi-asserted-by":"publisher","first-page":"408","DOI":"10.3109\/13645706.2012.666251","volume":"21","author":"K Henken","year":"2012","unstructured":"Henken K, Van Gerwen D, Dankelman J, Van Den Dobbelsteen J (2012) Accuracy of needle position measurements using fiber bragg gratings. Minim Invasive Ther Allied Technol 21(6):408\u2013414","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"2479_CR8","doi-asserted-by":"crossref","unstructured":"Heverly M, Dupont P, Triedman J (2005) Trajectory optimization for dynamic needle insertion. In: Proceedings of the 2005 IEEE international conference on robotics and automation, IEEE, pp 1646\u20131651","DOI":"10.1109\/ROBOT.2005.1570349"},{"key":"2479_CR9","doi-asserted-by":"crossref","unstructured":"Illanes A, Boese A, Friebe M, Hansen C (2020) Feasibility check: can audio be a simple alternative to force-based feedback for needle guidance? In: International conference on medical image computing and computer-assisted intervention, Springer, pp 24\u201333","DOI":"10.1007\/978-3-030-59716-0_3"},{"issue":"1","key":"2479_CR10","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-018-30641-0","volume":"8","author":"A Illanes","year":"2018","unstructured":"Illanes A, Boese A, Maldonado I, Pashazadeh A, Schaufler A, Navab N, Friebe M (2018) Novel clinical device tracking and tissue event characterization using proximally placed audio signal acquisition and processing. Sci Rep 8(1):1\u201311","journal-title":"Sci Rep"},{"key":"2479_CR11","doi-asserted-by":"crossref","unstructured":"Illanes A, S\u00fchn T, Esmaeili N, Maldonado I, Schaufler A, Chen CH, Boese A, Friebe M (2019) Surgical audio guidance surag: extracting non-invasively meaningful guidance information during minimally invasive procedures. In: 2019 IEEE 19th international conference on bioinformatics and bioengineering (BIBE), IEEE, pp 567\u2013570","DOI":"10.1109\/BIBE.2019.00108"},{"issue":"4","key":"2479_CR12","doi-asserted-by":"publisher","first-page":"383","DOI":"10.1007\/s11548-009-0301-6","volume":"4","author":"I Iordachita","year":"2009","unstructured":"Iordachita I, Sun Z, Balicki M, Kang J.U, Phee S.J, Handa J, Gehlbach P, Taylor R (2009) A sub-millimetric, 0.25 mn resolution fully integrated fiber-optic force-sensing tool for retinal microsurgery. Int J Comput Assist Radiol Surg 4(4):383\u2013390","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"2","key":"2479_CR13","doi-asserted-by":"publisher","first-page":"129","DOI":"10.1088\/0967-3334\/30\/2\/002","volume":"30","author":"H Kalv\u00f8y","year":"2009","unstructured":"Kalv\u00f8y H, Frich L, Grimnes S, Martinsen \u00d8G, Hol PK, Stubhaug A (2009) Impedance-based tissue discrimination for needle guidance. Physiol Meas 30(2):129","journal-title":"Physiol Meas"},{"issue":"12","key":"2479_CR14","doi-asserted-by":"publisher","first-page":"127009","DOI":"10.1117\/1.JBO.21.12.127009","volume":"21","author":"S Kumar","year":"2016","unstructured":"Kumar S, Shrikanth V, Amrutur B, Asokan S, Bobji MS (2016) Detecting stages of needle penetration into tissues through force estimation at needle tip using fiber bragg grating sensors. J Biomed Opt 21(12):127009","journal-title":"J Biomed Opt"},{"key":"2479_CR15","doi-asserted-by":"crossref","unstructured":"McWilliams SR, Murphy KP, Golestaneh S, O\u2019Regan KN, Arellano RS, Maher MM, O\u2019Connor OJ (2014) Reduction of guide needle streak artifact in CT-guided biopsy. J Vasc Int Radiol 25(12):1929\u20131935","DOI":"10.1016\/j.jvir.2014.08.028"},{"key":"2479_CR16","doi-asserted-by":"crossref","unstructured":"Okamura A.M, Simone C, O\u2019leary M.D (2004) Force modeling for needle insertion into soft tissue. IEEE Trans Biomed Eng 51(10):1707\u20131716","DOI":"10.1109\/TBME.2004.831542"},{"key":"2479_CR17","doi-asserted-by":"crossref","unstructured":"Park J, Park I (2016) Development of multi-spot impedance sensing biopsy needle based on attachable and flexible sensor film. In: 2016 38th annual international conference of the IEEE engineering in medicine and biology society (EMBC), IEEE, pp 4788\u20134791","DOI":"10.1109\/EMBC.2016.7591798"},{"key":"2479_CR18","doi-asserted-by":"crossref","unstructured":"Ravali G, Manivannan M (2017) Haptic feedback in needle insertion modeling and simulation. IEEE Rev Biomed Eng 10:63\u201377","DOI":"10.1109\/RBME.2017.2706966"},{"key":"2479_CR19","doi-asserted-by":"crossref","unstructured":"Renna F, Illanes A, Oliveira J, Esmaeili N, Friebe M, Coimbra MT (2019) Assessment of sound features for needle perforation event detection. In: 2019 41st annual international conference of the IEEE engineering in medicine and biology society (EMBC), IEEE, pp 2597\u20132600","DOI":"10.1109\/EMBC.2019.8857098"},{"issue":"5","key":"2479_CR20","doi-asserted-by":"publisher","first-page":"499","DOI":"10.1007\/s12630-012-9683-y","volume":"59","author":"G Reusz","year":"2012","unstructured":"Reusz G, Langer C, Jakab L, Morvay Z (2012) Ultrasound-guided vascular access: the importance of the needle bevel. Can J Anesth 59(5):499\u2013500","journal-title":"Can J Anesth"},{"key":"2479_CR21","unstructured":"Rezek I, Roberts SJ (1998) Envelope extraction via complex homomorphic filtering. Technical Report TR-98-9 Technical report"},{"issue":"1","key":"2479_CR22","doi-asserted-by":"publisher","first-page":"369","DOI":"10.1515\/cdbme-2019-0093","volume":"5","author":"A Schaufler","year":"2019","unstructured":"Schaufler A, S\u00fchn T, Esmaeili N, Boese A, Wex C, Croner R, Friebe M, Illanes A (2019) Automatic differentiation between Veress needle events in laparoscopic access using proximally attached audio signal characterization. Curr Dir Biomed Eng 5(1):369\u2013371","journal-title":"Curr Dir Biomed Eng"},{"issue":"5","key":"2479_CR23","doi-asserted-by":"publisher","first-page":"1242","DOI":"10.1007\/s00330-006-0470-4","volume":"17","author":"A Stadler","year":"2007","unstructured":"Stadler A, Schima W, Ba-Ssalamah A, Kettenbach J, Eisenhuber E (2007) Artifacts in body MR imaging: their appearance and how to eliminate them. Eur Radiol 17(5):1242\u20131255","journal-title":"Eur Radiol"},{"issue":"7","key":"2479_CR24","doi-asserted-by":"publisher","first-page":"1435","DOI":"10.1243\/09544062JMES1917","volume":"224","author":"A Trejos","year":"2010","unstructured":"Trejos A, Patel R, Naish M (2010) Force sensing and its application in minimally invasive surgery and therapy: a survey. Proc Inst Mech Eng Part C J Mech Eng Sci 224(7):1435\u20131454","journal-title":"Proc Inst Mech Eng Part C J Mech Eng Sci"},{"key":"2479_CR25","doi-asserted-by":"crossref","unstructured":"Washio T, Chinzei K (2004) Needle force sensor, robust and sensitive detection of the instant of needle puncture. In: International conference on medical image computing and computer-assisted intervention, Springer, pp 113\u2013120","DOI":"10.1007\/978-3-540-30136-3_15"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02479-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-021-02479-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02479-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2021,11,11]],"date-time":"2021-11-11T03:18:56Z","timestamp":1636600736000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-021-02479-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10]]},"references-count":25,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2021,10]]}},"alternative-id":["2479"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02479-x","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10]]},"assertion":[{"value":"16 February 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"10 August 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"This article does not contain any studies with human participants or animals performed by any of the authors.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"This articles does not contain patient data.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}