{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,28]],"date-time":"2026-03-28T00:46:49Z","timestamp":1774658809310,"version":"3.50.1"},"reference-count":24,"publisher":"Springer Science and Business Media LLC","issue":"2","license":[{"start":{"date-parts":[[2021,10,22]],"date-time":"2021-10-22T00:00:00Z","timestamp":1634860800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2021,10,22]],"date-time":"2021-10-22T00:00:00Z","timestamp":1634860800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["52175020"],"award-info":[{"award-number":["52175020"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2022,2]]},"DOI":"10.1007\/s11548-021-02519-6","type":"journal-article","created":{"date-parts":[[2021,10,22]],"date-time":"2021-10-22T13:05:24Z","timestamp":1634907924000},"page":"295-303","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":33,"title":["Automatic and accurate needle detection in 2D ultrasound during robot-assisted needle insertion process"],"prefix":"10.1007","volume":"17","author":[{"given":"Shihang","family":"Chen","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yanping","family":"Lin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Zhaojun","family":"Li","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fang","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qixin","family":"Cao","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2021,10,22]]},"reference":[{"issue":"4","key":"2519_CR1","doi-asserted-by":"publisher","first-page":"358","DOI":"10.1212\/CPJ.0000000000000265","volume":"6","author":"NJ Soni","year":"2016","unstructured":"Soni NJ, Franco-Sadud R, Schnobrich D, Dancel R, Tierney DM, Salame G, Restrepo MI, McHardy P (2016) Ultrasound guidance for lumbar puncture. Neurol Clin Pract 6(4):358\u2013368","journal-title":"Neurol Clin Pract"},{"issue":"3","key":"2519_CR2","doi-asserted-by":"publisher","first-page":"475","DOI":"10.1007\/s11548-020-02300-1","volume":"16","author":"SH Chen","year":"2021","unstructured":"Chen SH, Wang F, Lin YP, Shi QS, Wang YL (2021) Ultrasound-guided needle insertion robotic system for percutaneous puncture. Int J Comput Assist Radiol Surg 16(3):475\u2013484","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"6","key":"2519_CR3","doi-asserted-by":"publisher","first-page":"1092","DOI":"10.1093\/bja\/aet440","volume":"112","author":"J Morse","year":"2014","unstructured":"Morse J, Terrasini N, Wehbe M, Philippona C, Zaouter C, Cyr S, Hemmerling TM (2014) Comparison of success rates, learning curves, and inter-subject performance variability of robot-assisted and manual ultrasound-guided nerve block needle guidance in simulation. Br J Anaesth 112(6):1092\u20131097","journal-title":"Br J Anaesth"},{"key":"2519_CR4","doi-asserted-by":"publisher","first-page":"206","DOI":"10.1016\/j.ultras.2016.09.006","volume":"73","author":"Y Zhao","year":"2017","unstructured":"Zhao Y, Shen Y, Bernard A, Cachard C, Liebgott H (2017) Evaluation and comparison of current biopsy needle localization and tracking methods using 3D ultrasound. Ultrasonics 73:206\u2013220","journal-title":"Ultrasonics"},{"issue":"7","key":"2519_CR5","doi-asserted-by":"publisher","first-page":"1180","DOI":"10.1049\/iet-cta.2014.0672","volume":"9","author":"Y Zhao","year":"2015","unstructured":"Zhao Y, Liebgott H, Cachard C (2015) Comparison of the existing tool localisation methods on two-dimensional ultrasound images and their tracking results. IET Contr Theory Appl 9(7):1180\u20131180","journal-title":"IET Contr Theory Appl"},{"issue":"3","key":"2519_CR6","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1080\/13645706.2018.1496939","volume":"28","author":"Z Zhao","year":"2019","unstructured":"Zhao Z, Tse ZTH (2019) An electromagnetic tracking needle clip: an enabling design for low-cost image-guided therapy. Minim Invasive Ther Allied Technol 28(3):165\u2013171","journal-title":"Minim Invasive Ther Allied Technol"},{"key":"2519_CR7","doi-asserted-by":"publisher","first-page":"3674","DOI":"10.1038\/s41598-017-03886-4","volume":"7","author":"WF Xia","year":"2017","unstructured":"Xia WF, West SJ, Finlay MC, Mari JM, Ourselin S, David AL, Desjardins AE (2017) Looking beyond the imaging plane: 3D needle tracking with a linear array ultrasound probe. Sci Rep 7:3674. https:\/\/doi.org\/10.1038\/s41598-017-03886-4","journal-title":"Sci Rep"},{"issue":"8","key":"2519_CR8","doi-asserted-by":"publisher","first-page":"1828","DOI":"10.1007\/s10439-014-1208-0","volume":"43","author":"E Ayvali","year":"2015","unstructured":"Ayvali E, Desai JP (2015) Optical flow-based tracking of needles and needle-tip localization using circular hough transform in ultrasound images. Ann Biomed Eng 43(8):1828\u20131840","journal-title":"Ann Biomed Eng"},{"issue":"7","key":"2519_CR9","doi-asserted-by":"publisher","first-page":"1559","DOI":"10.1109\/TUFFC.2008.833","volume":"55","author":"M Barva","year":"2008","unstructured":"Barva M, Uhercik M, Mari JM, Kybic J, Duhamel JR, Liebgott H, Hlavac V, Cachard C (2008) Parallel integral projection transform for straight electrode localization in 3-D ultrasound images. IEEE Trans Ultrason Ferroelectr Freq Control 55(7):1559\u20131569","journal-title":"IEEE Trans Ultrason Ferroelectr Freq Control"},{"issue":"3","key":"2519_CR10","doi-asserted-by":"publisher","first-page":"966","DOI":"10.1109\/TCST.2016.2587733","volume":"25","author":"K Mathiassen","year":"2017","unstructured":"Mathiassen K, Dall\u2019Alba D, Muradore R, Fiorini P, Elle OJ (2017) Robust real-time needle tracking in 2-D ultrasound images using statistical filtering. IEEE Trans Control Syst Technol 25(3):966\u2013978","journal-title":"IEEE Trans Control Syst Technol"},{"key":"2519_CR11","doi-asserted-by":"crossref","unstructured":"Kaya M, Bebek O (2014) Needle localization using Gabor filtering in 2D ultrasound images. In: IEEE international conference on robotics and automation (ICRA), pp 4881\u20134886","DOI":"10.1109\/ICRA.2014.6907574"},{"issue":"4","key":"2519_CR12","doi-asserted-by":"publisher","first-page":"283","DOI":"10.1177\/0161734613502004","volume":"35","author":"Y Zhao","year":"2013","unstructured":"Zhao Y, Cachard C, Liebgott H (2013) Automatic needle detection and tracking in 3D ultrasound using an ROI-based RANSAC and Kalman method. Ultrason Imaging 35(4):283\u2013306","journal-title":"Ultrason Imaging"},{"issue":"6","key":"2519_CR13","doi-asserted-by":"publisher","first-page":"1183","DOI":"10.1007\/s11548-016-1402-7","volume":"11","author":"P Beigi","year":"2016","unstructured":"Beigi P, Rohling R, Salcudean SE, Ng GC (2016) Spectral analysis of the tremor motion for needle detection in curvilinear ultrasound via spatiotemporal linear sampling. Int J Comput Assist Radiol Surg 11(6):1183\u20131192","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2519_CR14","doi-asserted-by":"publisher","first-page":"60","DOI":"10.1016\/j.media.2017.07.005","volume":"42","author":"G Litjens","year":"2017","unstructured":"Litjens G, Kooi T, Bejnordi BE, Setio AAA, Ciompi F, Ghafoorian M, van der Laak JAWM, van Ginneken B, Sanchez CI (2017) A survey on deep learning in medical image analysis. Med Image Anal 42:60\u201388","journal-title":"Med Image Anal"},{"issue":"2","key":"2519_CR15","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1038\/s42256-020-0148-7","volume":"2","author":"AI Chen","year":"2020","unstructured":"Chen AI, Balter ML, Maguire TJ, Yarmush ML (2020) Deep learning robotic guidance for autonomous vascular access. Nat Mach Intell 2(2):104\u2013115","journal-title":"Nat Mach Intell"},{"issue":"3","key":"2519_CR16","doi-asserted-by":"publisher","first-page":"4517","DOI":"10.1109\/LRA.2020.3001474","volume":"5","author":"I Park","year":"2020","unstructured":"Park I, Kim HK, Chung WK, Kim K (2020) Deep learning based real-time OCT image segmentation and correction for robotic needle insertion systems. IEEE Robot Autom Let 5(3):4517\u20134524","journal-title":"IEEE Robot Autom Let"},{"issue":"8","key":"2519_CR17","doi-asserted-by":"publisher","first-page":"1393","DOI":"10.1007\/s11548-021-02437-7","volume":"16","author":"B Maris","year":"2021","unstructured":"Maris B, Tenga C, Vicario R, Palladino L, Murr N, De Piccoli M, Calanca A, Puliatti S, Micali S, Tafuri A, Fiorini P (2021) Toward autonomous robotic prostate biopsy: a pilot study. Int J Comput Assist Radiol Surg 16(8):1393\u20131401","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"5","key":"2519_CR18","doi-asserted-by":"publisher","first-page":"647","DOI":"10.1007\/s11548-018-1721-y","volume":"13","author":"C Mwikirize","year":"2018","unstructured":"Mwikirize C, Nosher JL, Hacihaliloglu I (2018) Convolution neural networks for real-time needle detection and localization in 2D ultrasound. Int J Comput Assist Radiol Surg 13(5):647\u2013657","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"3","key":"2519_CR19","doi-asserted-by":"publisher","first-page":"437","DOI":"10.1007\/s11548-019-02113-x","volume":"15","author":"JY Lee","year":"2020","unstructured":"Lee JY, Islam M, Woh JR, Washeem TSM, Ngoh LYC, Wong WK, Ren H (2020) Ultrasound needle segmentation and trajectory prediction using excitation network. Int J Comput Assist Radiol Surg 15(3):437\u2013443","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"9","key":"2519_CR20","doi-asserted-by":"publisher","first-page":"1321","DOI":"10.1007\/s11548-018-1798-3","volume":"13","author":"A Pourtaherian","year":"2018","unstructured":"Pourtaherian A, Ghazvinian Zanjani F, Zinger S, Mihajlovic N, Ng GC, Korsten HHM, de With PHN (2018) Robust and semantic needle detection in 3D ultrasound using orthogonal-plane convolutional neural networks. Int J Comput Assist Radiol Surg 13(9):1321\u20131333","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2519_CR21","doi-asserted-by":"publisher","first-page":"104","DOI":"10.1016\/j.media.2019.02.002","volume":"53","author":"M Arif","year":"2019","unstructured":"Arif M, Moelker A, van Walsum T (2019) Automatic needle detection and real-time Bi-planar needle visualization during 3D ultrasound scanning of the liver. Med Image Anal 53:104\u2013110","journal-title":"Med Image Anal"},{"key":"2519_CR22","doi-asserted-by":"crossref","unstructured":"Ronneberger O, Fischer P, Brox T (2015) U-Net: convolutional networks for biomedical image segmentation. In: Medical image computing and computer-assisted intervention (MICCAI), pp 234\u2013241","DOI":"10.1007\/978-3-319-24574-4_28"},{"key":"2519_CR23","doi-asserted-by":"crossref","unstructured":"Milletari F, Navab N, Ahmadi SA (2016) V-Net: fully convolutional neural networks for volumetric medical image segmentation. In: Proceedings of 2016 fourth international conference on 3d vision (3DV), pp 565\u2013571","DOI":"10.1109\/3DV.2016.79"},{"key":"2519_CR24","unstructured":"Kingma DP, Ba JL (2015) Adam: a method for stochastic optimization. In: Proceedings of the 3rd international conference in learning representations (ICLR)"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02519-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-021-02519-6\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-021-02519-6.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,1,24]],"date-time":"2022-01-24T15:12:33Z","timestamp":1643037153000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-021-02519-6"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,10,22]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["2519"],"URL":"https:\/\/doi.org\/10.1007\/s11548-021-02519-6","relation":{},"ISSN":["1861-6410","1861-6429"],"issn-type":[{"value":"1861-6410","type":"print"},{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2021,10,22]]},"assertion":[{"value":"1 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"5 October 2021","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"22 October 2021","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional and\/or national research committee and with the 1964 Helsinki Declaration and its later amendments or comparable ethical standards. No animal experiments were performed in this study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Human and animals rights"}},{"value":"Informed consent was obtained from all participants.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}