{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,20]],"date-time":"2026-01-20T00:57:46Z","timestamp":1768870666971,"version":"3.49.0"},"reference-count":44,"publisher":"Springer Science and Business Media LLC","issue":"4","license":[{"start":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T00:00:00Z","timestamp":1645056000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"},{"start":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T00:00:00Z","timestamp":1645056000000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/www.springer.com\/tdm"}],"funder":[{"DOI":"10.13039\/501100014913","name":"Free State of Saxony","doi-asserted-by":"crossref","award":["Project 100400036"],"award-info":[{"award-number":["Project 100400036"]}],"id":[{"id":"10.13039\/501100014913","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"published-print":{"date-parts":[[2022,4]]},"DOI":"10.1007\/s11548-022-02562-x","type":"journal-article","created":{"date-parts":[[2022,2,17]],"date-time":"2022-02-17T10:14:57Z","timestamp":1645092897000},"page":"683-697","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Registration of IRT and visible light images in neurosurgery: analysis and comparison of automatic intensity-based registration approaches"],"prefix":"10.1007","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0307-3219","authenticated-orcid":false,"given":"Yahya","family":"Moshaei-Nezhad","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Juliane","family":"M\u00fcller","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Martin","family":"Oelschl\u00e4gel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Matthias","family":"Kirsch","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ronald","family":"Tetzlaff","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"297","published-online":{"date-parts":[[2022,2,17]]},"reference":[{"issue":"6","key":"2562_CR1","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1007\/s00701-004-0229-0","volume":"146","author":"B Albayrak","year":"2004","unstructured":"Albayrak B, Samdani AF, Black PM (2004) Intra-operative magnetic resonance imaging in neurosurgery. Acta Neurochir 146(6):543\u2013557","journal-title":"Acta Neurochir"},{"issue":"2","key":"2562_CR2","doi-asserted-by":"crossref","first-page":"473","DOI":"10.3171\/2013.10.JNS13103","volume":"120","author":"Huang Abel Po-Hao","year":"2014","unstructured":"Po-Hao Huang Abel, Jui-Chang Tsai, Lu-Ting Kuo, Chung-Wei Lee, Hong-Shiee Lai, Li-Kai Tsai, Sheng-Jean Huang, Chien-Min Chen, Yuan-Shen Chen, Hao-Yu Chuang (2014) Clinical application of perfusion computed tomography in neurosurgery. J Neurosurg 120(2):473\u2013488","journal-title":"J Neurosurg"},{"key":"2562_CR3","unstructured":"Sol\u00eds ST, de Quintana Schmidt C, S\u00e1inchez JG, Portales IF, de Pedro MD, Berrocal VR, Valle RD, de trabajo de la SENEC G (2020) Intraoperative imaging in the neurosurgery operating theatre: a review of the most commonly used techniques for brain tumour surgery. Neurocirug\u00eda (English Edition)"},{"key":"2562_CR4","doi-asserted-by":"crossref","unstructured":"Moshaei-Nezhad Y, M\u00fcller J, Schnabel C, Kirsch M, Tetzlaff R (2021) A robust optical flow motion estimation and correction method for irt imaging in brain surgery. Quant Inf Thermo J 18(4):226\u2013251","DOI":"10.1080\/17686733.2020.1766892"},{"issue":"6","key":"2562_CR5","doi-asserted-by":"crossref","first-page":"1313","DOI":"10.1109\/TBCAS.2018.2856407","volume":"12","author":"Jan M\u00fcller","year":"2018","unstructured":"M\u00fcller Jan, M\u00fcller Jens, Chen Fang, Tetzlaff Ronald, M\u00fcller Juliane, B\u00f6hl Elisa, Kirsch Matthias, Schnabel Christian (2018) Registration and fusion of thermographic and visual-light images in neurosurgery. IEEE Trans Biomed Circuits Syst 12(6):1313\u20131321","journal-title":"IEEE Trans Biomed Circuits Syst"},{"key":"2562_CR6","doi-asserted-by":"crossref","unstructured":"Hollmach J, Hoffmann N, Schnabel C, K\u00fcchler S, Sobottka S, Kirsch M, Schackert G, Koch E, Steiner G ( 2013) Highly sensitive time-resolved thermography and multivariate image analysis of the cerebral cortex for intrasurgical diagnostics. In: Photonic therapeutics and diagnostics IX, volume 8565, page 856550. International society for optics and photonics","DOI":"10.1117\/12.2002342"},{"issue":"1","key":"2562_CR7","doi-asserted-by":"crossref","first-page":"016001","DOI":"10.1117\/1.3528011","volume":"16","author":"Steiner Gerald","year":"2011","unstructured":"Gerald Steiner, Sobottka Stephan B, Edmund Koch, Gabriele Schackert, Matthias Kirsch (2011) Intraoperative imaging of cortical cerebral perfusion by time-resolved thermography and multivariate data analysis. J Biomed Opt 16(1):016001","journal-title":"J Biomed Opt"},{"key":"2562_CR8","doi-asserted-by":"crossref","first-page":"600","DOI":"10.1016\/j.applthermaleng.2015.08.032","volume":"91","author":"Moslem Sadeghi-Goughari","year":"2015","unstructured":"Sadeghi-Goughari Moslem, Mojra Afsaneh (2015) Intraoperative thermal imaging of brain tumors using a haptic-thermal robot with application in minimally invasive neurosurgery. Appl Therm Eng 91:600\u2013610","journal-title":"Appl Therm Eng"},{"key":"2562_CR9","doi-asserted-by":"crossref","unstructured":"de\u00a0Font-R\u00e9aulx E, L\u00f3pez LR, D\u00edaz LLG (2020) Infrared thermography mapping plus neuronavigation target location in an eloquent area cavernoma resection. Surgical neurology international, 11","DOI":"10.25259\/SNI_435_2019"},{"issue":"4","key":"2562_CR10","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1016\/j.infrared.2012.03.007","volume":"55","author":"BB Lahiri","year":"2012","unstructured":"Lahiri BB, Bagavathiappan S, Jayakumar T, John Philip (2012) Medical applications of infrared thermography: a review. Inf Phys Technol 55(4):221\u2013235","journal-title":"Inf Phys Technol"},{"key":"2562_CR11","doi-asserted-by":"crossref","unstructured":"Maurya L, Mahapatra P, Chawla D, Verma S (2020) An automatic thermal and visible image registration using a calibration rig. Recent trends in image and signal processing in computer vision, page\u00a067","DOI":"10.1007\/978-981-15-2740-1_5"},{"issue":"11","key":"2562_CR12","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1016\/S0262-8856(03)00137-9","volume":"21","author":"Barbara Zitova","year":"2003","unstructured":"Zitova Barbara, Flusser Jan (2003) Image registration methods: a survey. Image Vis Comput 21(11):977\u20131000","journal-title":"Image Vis Comput"},{"key":"2562_CR13","doi-asserted-by":"crossref","unstructured":"Harris CG, Stephens M (1988) A combined corner and edge detector. In: Alvey vision conference, vol 15, pp 10\u20135244. Citeseer","DOI":"10.5244\/C.2.23"},{"key":"2562_CR14","doi-asserted-by":"crossref","unstructured":"Bay H, Tuytelaars T, Gool LV ( 2006) Surf: Speeded up robust features. In: European conference on computer vision, pp 404\u2013417. Springer","DOI":"10.1007\/11744023_32"},{"key":"2562_CR15","doi-asserted-by":"crossref","unstructured":"Rosten E, Drummond T (2005) Fusing points and lines for high performance tracking. In: Tenth IEEE international conference on computer vision (ICCV\u201905). Vol. 1, 2, pp. 1508\u20131515. Ieee","DOI":"10.1109\/ICCV.2005.104"},{"key":"2562_CR16","doi-asserted-by":"crossref","unstructured":"Rublee E, Rabaud V, Konolige K, Bradski G (2011) Orb: an efficient alternative to sift or surf. In: 2011 international conference on computer vision, pp 2564\u20132571. Ieee","DOI":"10.1109\/ICCV.2011.6126544"},{"key":"2562_CR17","doi-asserted-by":"crossref","unstructured":"Bom IMJ Van\u00a0der, Klein S, Staring M, Homan R, Bartels LW, Pluim JPW (2011) Evaluation of optimization methods for intensity-based 2d-3d registration in x-ray guided interventions. In: Medical imaging 2011: image processing, vol 7962, p 796223. International Society for Optics and Photonics","DOI":"10.1117\/12.877655"},{"issue":"4","key":"2562_CR18","doi-asserted-by":"crossref","first-page":"586","DOI":"10.1109\/42.730403","volume":"17","author":"P Penney Graeme","year":"1998","unstructured":"Penney Graeme P, J\u00fcrgen Weese, Little John A, Paul Desmedt, Hill Derek LG, Hawkes David J (1998) A comparison of similarity measures for use in 2-d-3-d medical image registration. IEEE Trans Med Imaging 17(4):586\u2013595","journal-title":"IEEE Trans Med Imaging"},{"issue":"6","key":"2562_CR19","doi-asserted-by":"crossref","first-page":"1024","DOI":"10.1118\/1.1373400","volume":"28","author":"P Penney Graeme","year":"2001","unstructured":"Penney Graeme P, Batchelor Philipp G, Hill Derek LG, Hawkes David J, Juergen Weese (2001) Validation of a two-to three-dimensional registration algorithm for aligning preoperative ct images and intraoperative fluoroscopy images. Med Phys 28(6):1024\u20131032","journal-title":"Med Phys"},{"key":"2562_CR20","unstructured":"Rahunathan S, Stredney D, Schmalbrock P, Clymer BD (2005) Image registration using rigid registration and maximization of mutual information. In: 13th annual medicine meets virtual reality conference"},{"issue":"1","key":"2562_CR21","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.media.2005.06.002","volume":"10","author":"Ali Khamene","year":"2006","unstructured":"Khamene Ali, Bloch Peter, Wein Wolfgang, Svatos Michelle, Sauer Frank (2006) Automatic registration of portal images and volumetric ct for patient positioning in radiation therapy. Med Image Anal 10(1):96\u2013112","journal-title":"Med Image Anal"},{"issue":"11","key":"2562_CR22","doi-asserted-by":"crossref","first-page":"1417","DOI":"10.1109\/TMI.2003.819283","volume":"22","author":"H Hipwell John","year":"2003","unstructured":"Hipwell John H, Penney Graeme P, McLaughlin Robert A, Kawal Rhode, Paul Summers, Cox Tim C, Byrne James V, Alison Noble J, Hawkes David J (2003) Intensity-based 2-d-3-d registration of cerebral angiograms. IEEE Trans Med Imaging 22(11):1417\u20131426","journal-title":"IEEE Trans Med Imaging"},{"issue":"2","key":"2562_CR23","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1080\/10255842.2012.670855","volume":"17","author":"PM Oliveira Francisco","year":"2014","unstructured":"Oliveira Francisco PM, Joao Manuel RS, Tavares (2014) Medical image registration: a review. Comput Methods Biomech Biomed Eng 17(2):73\u201393","journal-title":"Comput Methods Biomech Biomed Eng"},{"issue":"3","key":"2562_CR24","doi-asserted-by":"crossref","first-page":"R1","DOI":"10.1088\/0031-9155\/46\/3\/201","volume":"46","author":"LG Hill Derek","year":"2001","unstructured":"Hill Derek LG, Batchelor Philipp G, Mark Holden, Hawkes David J (2001) Medical image registration. Phys Med Biol 46(3):R1","journal-title":"Phys Med Biol"},{"issue":"7","key":"2562_CR25","doi-asserted-by":"crossref","first-page":"1153","DOI":"10.1109\/TMI.2013.2265603","volume":"32","author":"Aristeidis Sotiras","year":"2013","unstructured":"Sotiras Aristeidis, Davatzikos Christos, Paragios Nikos (2013) Deformable medical image registration: a survey. IEEE Trans Med Imaging 32(7):1153\u20131190","journal-title":"IEEE Trans Med Imaging"},{"key":"2562_CR26","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1016\/j.inffus.2018.02.004","volume":"45","author":"Jiayi Ma","year":"2019","unstructured":"Ma Jiayi, Ma Yong, Li Chang (2019) Infrared and visible image fusion methods and applications: a survey. Inf Fusion 45:153\u2013178","journal-title":"Inf Fusion"},{"issue":"7","key":"2562_CR27","doi-asserted-by":"crossref","first-page":"3584","DOI":"10.1109\/TIP.2019.2899947","volume":"28","author":"Johan \u00d6fverstedt","year":"2019","unstructured":"\u00d6fverstedt Johan, Lindblad Joakim, Sladoje Nata\u0161a (2019) Fast and robust symmetric image registration based on distances combining intensity and spatial information. IEEE Trans Image Process 28(7):3584\u20133597","journal-title":"IEEE Trans Image Process"},{"key":"2562_CR28","doi-asserted-by":"crossref","unstructured":"Moshaei-Nezhad Y, M\u00fcller J, Tetzlaff R, Hoffmann N (2018) A new approach for motion estimation and correction of thermographic images in brain surgery. In: CNNA 2018; The 16th international workshop on cellular nanoscale networks and their applications, pp 1\u20134. VDE","DOI":"10.1109\/ECCTD.2017.8093336"},{"key":"2562_CR29","doi-asserted-by":"crossref","unstructured":"Moshaei-Nezhad Y, M\u00fcller J, Schnabel C, Kirsch M, Tetzlaff R (2021) Motion correction for irt imaging in neurosurgery: analysis and comparison of frequency-\/filter-and intensity-based approaches. Inf Phys Technol 117:103804","DOI":"10.1016\/j.infrared.2021.103804"},{"key":"2562_CR30","doi-asserted-by":"crossref","unstructured":"Tustison Nicholas J, Avants Brian B, Gee James C (2009) Directly manipulated free-form deformation image registration. IEEE Trans Image Process 18(3):624\u2013635","DOI":"10.1109\/TIP.2008.2010072"},{"issue":"12","key":"2562_CR31","doi-asserted-by":"crossref","first-page":"2879","DOI":"10.1109\/TIP.2007.909412","volume":"16","author":"Klein Stefan","year":"2007","unstructured":"Stefan Klein, Marius Staring, Pluim Josien PW (2007) Evaluation of optimization methods for nonrigid medical image registration using mutual information and b-splines. IEEE Trans Image Process 16(12):2879\u20132890","journal-title":"IEEE Trans Image Process"},{"key":"2562_CR32","unstructured":"Shackleford J, Kandasamy N, Sharp G (2013) High performance deformable image registration algorithms for manycore processors. Newnes"},{"issue":"3","key":"2562_CR33","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1109\/42.845174","volume":"19","author":"Styner Martin","year":"2000","unstructured":"Martin Styner, Christian Brechbuhler, Szckely G, Guido Gerig (2000) Parametric estimate of intensity inhomogeneities applied to mri. IEEE Trans Med Imag 19(3):153\u2013165","journal-title":"IEEE Trans Med Imag"},{"key":"2562_CR34","volume-title":"Numerical optimization","author":"J Nocedal","year":"2006","unstructured":"Nocedal J, Wright S (2006) Numerical optimization. Springer, Berlin"},{"issue":"8","key":"2562_CR35","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1109\/TIP.2003.814248","volume":"12","author":"E Reichenbach Stephen","year":"2003","unstructured":"Reichenbach Stephen E, Frank Geng (2003) Two-dimensional cubic convolution. IEEE Trans Image Process 12(8):857\u2013865","journal-title":"IEEE Trans Image Process"},{"issue":"1","key":"2562_CR36","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.media.2012.09.005","volume":"17","author":"R McClelland Jamie","year":"2013","unstructured":"McClelland Jamie R, Hawkes David J, Tobias Schaeffter, King Andrew P (2013) Respiratory motion models: a review. Med Image Anal 17(1):19\u201342","journal-title":"Med Image Anal"},{"key":"2562_CR37","doi-asserted-by":"crossref","unstructured":"Zuiderveld K (1994) Contrast limited adaptive histogram equalization. Graphics gems, pp 474\u2013485","DOI":"10.1016\/B978-0-12-336156-1.50061-6"},{"key":"2562_CR38","doi-asserted-by":"crossref","unstructured":"Ridler TW, Calvard S (1978) Picture thresholding using an iterative selection method. IEEE Trans Syst Man Cybern 8(8):630\u2013632","DOI":"10.1109\/TSMC.1978.4310039"},{"key":"2562_CR39","doi-asserted-by":"crossref","unstructured":"Russakoff DB, Tomasi C, Rohlfing T, Maurer CR (2004) Image similarity using mutual information of regions. In: European conference on computer vision, pp 596\u2013607. Springer","DOI":"10.1007\/978-3-540-24672-5_47"},{"key":"2562_CR40","doi-asserted-by":"crossref","unstructured":"Thirion J-P (1998) Image matching as a diffusion process: an analogy with maxwell\u2019s demons. Med Image Anal 2(3):243\u2013260","DOI":"10.1016\/S1361-8415(98)80022-4"},{"issue":"1","key":"2562_CR41","doi-asserted-by":"crossref","first-page":"S61","DOI":"10.1016\/j.neuroimage.2008.10.040","volume":"45","author":"Tom Vercauteren","year":"2009","unstructured":"Vercauteren Tom, Pennec Xavier, Perchant Aymeric, Ayache Nicholas (2009) Diffeomorphic demons: efficient non-parametric image registration. Neuroimage 45(1):S61\u2013S72","journal-title":"Neuroimage"},{"key":"2562_CR42","doi-asserted-by":"crossref","unstructured":"Daniel Rueckert, Sonoda Luke I, Carmel Hayes, Hill Derek LG, Leach Martin O, Hawkes David J (1999) Nonrigid registration using free-form deformations: application to breast mr images. IEEE Trans Med Imag 18(8):712\u2013721","DOI":"10.1109\/42.796284"},{"key":"2562_CR43","doi-asserted-by":"crossref","unstructured":"Kabus Sven, Netsch Thomas, Fischer Bernd, Modersitzki Jan (2004) B-spline registration of 3d images with levenberg-marquardt optimization. In: Medical imaging 2004: image processing, vol 5370, pp 304\u2013313. International Society for Optics and Photonics","DOI":"10.1117\/12.533976"},{"issue":"1","key":"2562_CR44","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1016\/j.parco.2004.12.001","volume":"31","author":"Fumihiko Ino","year":"2005","unstructured":"Ino Fumihiko, Ooyama Kanrou, Hagihara Kenichi (2005) A data distributed parallel algorithm for nonrigid image registration. Parallel Comput 31(1):19\u201343","journal-title":"Parallel Comput"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02562-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02562-x\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02562-x.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2024,9,18]],"date-time":"2024-09-18T20:25:24Z","timestamp":1726691124000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02562-x"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2,17]]},"references-count":44,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["2562"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02562-x","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,2,17]]},"assertion":[{"value":"3 June 2021","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"6 January 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"17 February 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"Authors state no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"The research related to the human use complies with all the relevant national regulations, institutional policies and was performed in accordance with the tenets of the Helsinki Declaration","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"Informed consent has been obtained from all patients.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}