{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,11]],"date-time":"2026-01-11T17:16:00Z","timestamp":1768151760452,"version":"3.49.0"},"reference-count":18,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T00:00:00Z","timestamp":1653004800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T00:00:00Z","timestamp":1653004800000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13GW0388A"],"award-info":[{"award-number":["13GW0388A"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>\n                           <jats:bold>Purpose<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>Development of an algorithm to self-calibrate arbitrary CBCT trajectories which can be used to reduce metal artifacts. By using feature detection and matching we want to reduce the amount of parameters for the BFGS optimization and thus reduce the runtime.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Methods<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>Each projection is 2D-3D registered on a prior image with AKAZE feature detection and brute force matching. Translational misalignment is calculated directly from the misalignment of feature positions, rotations are aligned using a minimization algorithm that fits a quartic function and determines the minimum of this function.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Evaluation<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>We did three experiments to compare how well the algorithm can handle noise on the different degrees of freedom. Our algorithms are compared to Broyden\u2013Fletcher\u2013Goldfarb\u2013Shanno (BFGS) minimizer with Normalized Gradient Information (NGI) objective function, and BFGS with distance between features objective function using SSIM, nRMSE, and the Dice coefficient of segmented metal object.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Results<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>Our algorithm (Feature ORiented Calibration for Arbitrary Scan Trajectories with Enhanced Reliability (FORCASTER)) performs on par with the state-of-the-art algorithms (BFGS with NGI objective). nRMSE: FORCASTER = 0.3390, BFGS+NGI = 0.3441; SSIM: FORCASTER = 0.83, BFGS + NGI = 0.79; Dice: FORCASTER = 0.86, BFGS + NGI = 0.87.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>\n                           <jats:bold>Conclusion<\/jats:bold>\n                        <\/jats:title>\n                <jats:p>The proposed algorithm can determine the parameters of the projection orientations for arbitrary trajectories with calibration quality comparable to state-of-the-art algorithms, but faster and with higher tolerance to errors in the initially guessed parameters.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-022-02645-9","type":"journal-article","created":{"date-parts":[[2022,5,20]],"date-time":"2022-05-20T08:04:05Z","timestamp":1653033845000},"page":"2151-2159","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":5,"title":["Feature-based CBCT self-calibration for arbitrary trajectories"],"prefix":"10.1007","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9323-5559","authenticated-orcid":false,"given":"Christian","family":"T\u00f6nnes","sequence":"first","affiliation":[]},{"given":"Tom","family":"Russ","sequence":"additional","affiliation":[]},{"given":"Lothar R.","family":"Schad","sequence":"additional","affiliation":[]},{"given":"Frank G.","family":"Z\u00f6llner","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2022,5,20]]},"reference":[{"key":"2645_CR1","doi-asserted-by":"crossref","unstructured":"Gang GJ, Siewerdsen JH, Stayman JW (2020) Non-circular ct orbit design for elimination of metal artifacts. Medical imaging 2020: physics of medical imaging 11312:27","DOI":"10.1117\/12.2550203"},{"key":"2645_CR2","doi-asserted-by":"publisher","unstructured":"Pearson EA, Cho S, Pelizzari CA, Pan X (2010) Non-circular cone beam ct trajectories: a preliminary investigation on a clinical scanner. In: IEEE nuclear science symposuim medical imaging conference. pp 3172\u20133175. https:\/\/doi.org\/10.1109\/NSSMIC.2010.5874387","DOI":"10.1109\/NSSMIC.2010.5874387"},{"key":"#cr-split#-2645_CR3.1","unstructured":"Herbst M, Schebesch F, Berger M, Fahrig R, Hornegger J, Maier A (2014) Improved trajectories in c-arm computed tomography for non-circular fields of view. In: Proceedings of the third international conference on image formation in X-ray computed tomography, Noo F"},{"key":"#cr-split#-2645_CR3.2","unstructured":"(ed) (Salt Lake City, UT, 2014) pp 274-278"},{"key":"2645_CR4","doi-asserted-by":"publisher","unstructured":"Hatamikia S, Biguri A, Kronreif G, Russ T, Kettenbach J, Birkfellner W (2020) Short scan source-detector trajectories for target-based cbct. In: 2020 42nd annual international conference of the IEEE engineering in medicine biology society (EMBC). pp 1299\u20131302. https:\/\/doi.org\/10.1109\/EMBC44109.2020.9176667","DOI":"10.1109\/EMBC44109.2020.9176667"},{"issue":"10","key":"2645_CR5","doi-asserted-by":"publisher","first-page":"5959","DOI":"10.1118\/1.4739247","volume":"39","author":"D Gross","year":"2012","unstructured":"Gross D, Heil U, Schulze R, Schoemer E, Schwanecke U (2012) Auto calibration of a cone-beam-ct. Medical Phys 39(10):5959\u20135970. https:\/\/doi.org\/10.1118\/1.4739247","journal-title":"Medical Phys"},{"key":"2645_CR6","doi-asserted-by":"publisher","first-page":"610","DOI":"10.1117\/12.811505","volume":"7258","author":"Y Kyriakou","year":"2009","unstructured":"Kyriakou Y, Lapp RM, Hillebrand L, Ertel D, Kalender WA (2009) Image-based online correction of misalignment artifacts in cone-beam CT. Med Imag 2009 Phys Med Imag 7258:610\u2013619. https:\/\/doi.org\/10.1117\/12.811505","journal-title":"Med Imag 2009 Phys Med Imag"},{"issue":"1","key":"2645_CR7","doi-asserted-by":"publisher","first-page":"202","DOI":"10.1109\/TNS.2013.2293969","volume":"61","author":"J Muders","year":"2014","unstructured":"Muders J, Hesser J (2014) Stable and robust geometric self-calibration for cone-beam ct using mutual information. IEEE Trans Nuclear Sci 61(1):202\u2013217. https:\/\/doi.org\/10.1109\/TNS.2013.2293969","journal-title":"IEEE Trans Nuclear Sci"},{"key":"2645_CR8","unstructured":"Stopp F, Wieckowski AJ, K\u00e4seberg M, Engel S, Fehlhaber F, Keeve E (2013) A geometric calibration method for an open cone-beam ct system. In: 12th international meeting on fully three-dimensional image reconstruction in radiology and nuclear medicine. pp 106\u2013109"},{"issue":"6Part1","key":"2645_CR9","doi-asserted-by":"publisher","first-page":"1695","DOI":"10.1118\/1.2198187","volume":"33","author":"K Yang","year":"2006","unstructured":"Yang K, Kwan ALC, Miller DF, Boone JM (2006) A geometric calibration method for cone beam ct systems. Medical Phys 33(6Part1):1695\u20131706. https:\/\/doi.org\/10.1118\/1.2198187","journal-title":"Medical Phys"},{"issue":"12","key":"2645_CR10","doi-asserted-by":"publisher","first-page":"3242","DOI":"10.1118\/1.1803792","volume":"31","author":"L von Smekal","year":"2004","unstructured":"von Smekal L, Kachelrie\u00df M, Stepina E, Kalender WA (2004) Geometric misalignment and calibration in cone-beam tomography. Medical Phys 31(12):3242\u20133266. https:\/\/doi.org\/10.1118\/1.1803792","journal-title":"Medical Phys"},{"issue":"7","key":"2645_CR11","doi-asserted-by":"publisher","first-page":"2613","DOI":"10.1088\/0031-9155\/61\/7\/2613","volume":"61","author":"S Ouadah","year":"2016","unstructured":"Ouadah S, Stayman JW, Gang GJ, Ehtiati T, Siewerdsen JH (2016) Self-calibration of cone-beam CT geometry using 3d\u20132d image registration. Phys Med Biol 61(7):2613\u20132632. https:\/\/doi.org\/10.1088\/0031-9155\/61\/7\/2613","journal-title":"Phys Med Biol"},{"issue":"10","key":"2645_CR12","doi-asserted-by":"publisher","first-page":"1481","DOI":"10.1007\/s11548-018-1782-y","volume":"13","author":"K Chung","year":"2018","unstructured":"Chung K, Schad LR, Z\u00f6llner FG (2018) Tomosynthesis implementation with adaptive online calibration on clinical c-arm systems. Int J Comput Assist Radiol Surg 13(10):1481\u20131495. https:\/\/doi.org\/10.1007\/s11548-018-1782-y","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2645_CR13","first-page":"404","volume":"2006","author":"H Bay","year":"2006","unstructured":"Bay H, Tuytelaars T, Van Gool L (2006) Surf: speeded up robust features. Comput Vis- ECCV 2006:404\u2013417","journal-title":"Comput Vis- ECCV"},{"issue":"22","key":"2645_CR14","doi-asserted-by":"publisher","first-page":"25129","DOI":"10.1364\/OE.24.025129","volume":"24","author":"W van Aarle","year":"2016","unstructured":"van Aarle W, Palenstijn WJ, Cant J, Janssens E, Bleichrodt F, Dabravolski A, Beenhouwer JD, Batenburg KJ, Sijbers J (2016) Fast and flexible x-ray tomography using the astra toolbox. Opt Express 24(22):25129\u201325147. https:\/\/doi.org\/10.1364\/OE.24.025129","journal-title":"Opt Express"},{"issue":"7","key":"2645_CR15","first-page":"1281","volume":"34","author":"PF Alcantarilla","year":"2011","unstructured":"Alcantarilla PF, Solutions T (2011) Fast explicit diffusion for accelerated features in nonlinear scale spaces. IEEE Trans Patt Anal Mach Intell 34(7):1281\u20131298","journal-title":"IEEE Trans Patt Anal Mach Intell"},{"issue":"2","key":"2645_CR16","doi-asserted-by":"publisher","first-page":"91","DOI":"10.1023\/B:VISI.0000029664.99615.94","volume":"60","author":"DG Lowe","year":"2004","unstructured":"Lowe DG (2004) Distinctive image features from scale-invariant keypoints. Int J Comput Vis 60(2):91\u2013110. https:\/\/doi.org\/10.1023\/B:VISI.0000029664.99615.94","journal-title":"Int J Comput Vis"},{"issue":"4","key":"2645_CR17","doi-asserted-by":"publisher","first-page":"600","DOI":"10.1109\/TIP.2003.819861","volume":"13","author":"Z Wang","year":"2004","unstructured":"Wang Z, Bovik A, Sheikh H, Simoncelli E (2004) Image quality assessment: from error visibility to structural similarity. IEEE Trans Image Process 13(4):600\u2013612. https:\/\/doi.org\/10.1109\/TIP.2003.819861","journal-title":"IEEE Trans Image Process"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02645-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02645-9\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02645-9.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,27]],"date-time":"2022-09-27T12:35:53Z","timestamp":1664282153000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02645-9"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5,20]]},"references-count":18,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,11]]}},"alternative-id":["2645"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02645-9","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,5,20]]},"assertion":[{"value":"11 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 April 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"20 May 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}}]}}