{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,15]],"date-time":"2026-04-15T16:42:21Z","timestamp":1776271341799,"version":"3.50.1"},"reference-count":25,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,6,15]],"date-time":"2022-06-15T00:00:00Z","timestamp":1655251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,15]],"date-time":"2022-06-15T00:00:00Z","timestamp":1655251200000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100014438","name":"Business Finland","doi-asserted-by":"crossref","award":["930\/31\/2019"],"award-info":[{"award-number":["930\/31\/2019"]}],"id":[{"id":"10.13039\/501100014438","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>In dental implantology, the optimal placement of dental implants is important to meet functional and aesthetic requirements. Planning dental implants in virtual three-dimensional (3D) environment is possible using virtual reality (VR) technologies. The three-dimensional stereoscopic virtual reality environment offers advantages over three-dimensional projection on a two-dimensional display. The use of voice commands in virtual reality environment to replace button presses and other simple actions frees the user\u2019s hands and eyes for other tasks.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>Six dentomaxillofacial radiologists experimented using a prototype version of a three-dimensional virtual reality implant planning tool, and used two different tool selection methods, using either only button presses or also voice commands. We collected objective measurements of the results and subjective data of the participant experience to compare the two conditions.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>The tool was approved by the experts and they were able to do the multiple-implant planning satisfactorily. The radiologists liked the possibility to use the voice commands. Most of the radiologists were willing to use the tool as part of their daily work routines.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>The voice commands were useful, natural, and accurate for mode change, and they could be expanded to other tasks. Button presses and the voice commands should be both available and used in parallel. The input methods can be further improved based on the expert comments.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-022-02685-1","type":"journal-article","created":{"date-parts":[[2022,6,15]],"date-time":"2022-06-15T18:02:52Z","timestamp":1655316172000},"page":"1981-1989","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":9,"title":["Evaluation of voice commands for mode change in virtual reality implant planning procedure"],"prefix":"10.1007","volume":"17","author":[{"given":"Hanna-Riikka","family":"Rantamaa","sequence":"first","affiliation":[]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1970-1862","authenticated-orcid":false,"given":"Jari","family":"Kangas","sequence":"additional","affiliation":[]},{"given":"Maarit","family":"Jordan","sequence":"additional","affiliation":[]},{"given":"Helena","family":"Mehtonen","sequence":"additional","affiliation":[]},{"given":"John","family":"M\u00e4kel\u00e4","sequence":"additional","affiliation":[]},{"given":"Kimmo","family":"Ronkainen","sequence":"additional","affiliation":[]},{"given":"Markku","family":"Turunen","sequence":"additional","affiliation":[]},{"given":"Osku","family":"Sundqvist","sequence":"additional","affiliation":[]},{"given":"Ismo","family":"Syrj\u00e4","sequence":"additional","affiliation":[]},{"given":"Jorma","family":"J\u00e4rnstedt","sequence":"additional","affiliation":[]},{"given":"Roope","family":"Raisamo","sequence":"additional","affiliation":[]}],"member":"297","published-online":{"date-parts":[[2022,6,15]]},"reference":[{"issue":"7","key":"2685_CR1","doi-asserted-by":"publisher","first-page":"644","DOI":"10.1016\/j.bjoms.2019.02.014","volume":"57","author":"AK Bartella","year":"2019","unstructured":"Bartella AK, Kamal M, Scholl I, Schiffer S, Steegmann J, Ketelsen D, H\u00f6lzle F, Lethaus B (2019) Virtual reality in preoperative imaging in maxillofacial surgery: implementation of \u201cthe next level\u2019\u2019? Br J Oral Maxillofac Surg 57(7):644\u2013648","journal-title":"Br J Oral Maxillofac Surg"},{"key":"2685_CR2","doi-asserted-by":"crossref","unstructured":"Mendes D, Caputo FM, Giachetti A, Ferreira A, Jorge J (2019) A survey on 3d virtual object manipulation: from the desktop to immersive virtual environments. In: Computer Graphics Forum, vol 38, pp 21\u201345, Wiley Online Library","DOI":"10.1111\/cgf.13390"},{"key":"2685_CR3","doi-asserted-by":"crossref","unstructured":"Sutherland IE (1968) A head-mounted three dimensional display. In: Proceedings of the December 9\u201311, 1968, Fall Joint Computer Conference, Part I, pp 757\u2013764","DOI":"10.1145\/1476589.1476686"},{"issue":"1","key":"2685_CR4","first-page":"34","volume":"6","author":"D Randall","year":"2015","unstructured":"Randall D, Metherall P, Bardhan KD, Spencer P, Gillott R, De Noronha R, Fenner JW (2015) The oculus rift virtual colonoscopy: introducing a new technology and initial impressions. J Biomed Gr Comput 6(1):34\u201342","journal-title":"J Biomed Gr Comput"},{"key":"2685_CR5","doi-asserted-by":"crossref","unstructured":"Sousa M, Mendes D, Paulo S, Matela N, Jorge J, Lopes D (2017) Vrrrroom: virtual reality for radiologists in the reading room. In: Proceedings of the 2017 CHI Conference on Human Factors in Computing Systems, pp 4057\u20134062","DOI":"10.1145\/3025453.3025566"},{"key":"2685_CR6","unstructured":"Vensona JE, Bernib JCA, da Silva\u00a0Maiab CE, da Silvac AMM, d\u2019Ornellasd MC, Maciela A (2018) A case-based study with radiologists performing diagnosis tasks in virtual reality. In: MEDINFO 2017: Precision Healthcare Through Informatics: Proceedings of the 16th World Congress on Medical and Health Informatics, vol 245, p 244. IOS Press"},{"key":"2685_CR7","doi-asserted-by":"publisher","first-page":"102561","DOI":"10.1016\/j.ijhcs.2020.102561","volume":"147","author":"Z Li","year":"2021","unstructured":"Li Z, Kiiveri M, Rantala J, Raisamo R (2021) Evaluation of haptic virtual reality user interfaces for medical marking on 3d models. Int J Hum Comput Stud 147:102561","journal-title":"Int J Hum Comput Stud"},{"issue":"5","key":"2685_CR8","doi-asserted-by":"publisher","first-page":"2702","DOI":"10.1109\/TVCG.2021.3067687","volume":"27","author":"P Monteiro","year":"2021","unstructured":"Monteiro P, Gon\u00e7alves G, Coelho H, Melo M, Bessa M (2021) Hands-free interaction in immersive virtual reality: a systematic review. IEEE Trans Vis Comput Graph 27(5):2702\u20132713","journal-title":"IEEE Trans Vis Comput Graph"},{"key":"2685_CR9","unstructured":"Hannema D (2001) Interaction in virtual reality. Interaction in Virtual Reality"},{"issue":"1","key":"2685_CR10","first-page":"57","volume":"59","author":"IB Camargo","year":"2015","unstructured":"Camargo IB, Van Sickels JE (2015) Surgical complications after implant placement. Dental Clin 59(1):57\u201372","journal-title":"Dental Clin"},{"issue":"7","key":"2685_CR11","doi-asserted-by":"publisher","first-page":"758","DOI":"10.1016\/j.ijom.2010.11.027","volume":"40","author":"Y-H Hong","year":"2011","unstructured":"Hong Y-H, Mun S-K (2011) A case of massive maxillary sinus bleeding after dental implant. Int J Oral Maxillofac Surg 40(7):758\u2013760","journal-title":"Int J Oral Maxillofac Surg"},{"issue":"1","key":"2685_CR12","first-page":"143","volume":"59","author":"M Al-Sabbagh","year":"2015","unstructured":"Al-Sabbagh M, Okeson JP, Bertoli E, Medynski DC, Khalaf MW (2015) Persistent pain and neurosensory disturbance after dental implant surgery: prevention and treatment. Dental Clin 59(1):143\u2013156","journal-title":"Dental Clin"},{"issue":"1","key":"2685_CR13","first-page":"195","volume":"59","author":"R Sadid-Zadeh","year":"2015","unstructured":"Sadid-Zadeh R, Kutkut A, Kim H (2015) Prosthetic failure in implant dentistry. Dental Clin 59(1):195\u2013214","journal-title":"Dental Clin"},{"issue":"1","key":"2685_CR14","doi-asserted-by":"publisher","first-page":"1","DOI":"10.1038\/s41598-021-87062-9","volume":"11","author":"Y-J Yi","year":"2021","unstructured":"Yi Y-J, Park I-W, Ku J-K, Jo D-W, Han J-S, Kim Y-K (2021) Long term clinical result of implant induced injury on the adjacent tooth. Sci Rep 11(1):1\u20139","journal-title":"Sci Rep"},{"key":"2685_CR15","doi-asserted-by":"crossref","unstructured":"Surale HB, Matulic F, Vogel D (2019) Experimental analysis of barehand mid-air mode-switching techniques in virtual reality. In: Proceedings of the 2019 CHI conference on human factors in computing systems, pp 1\u201314","DOI":"10.1145\/3290605.3300426"},{"key":"2685_CR16","unstructured":"Bowman DA, Wingrave CA (2001) Design and evaluation of menu systems for immersive virtual environments. In: Proceedings IEEE virtual reality 2001, pp 149\u2013156. IEEE"},{"issue":"2","key":"2685_CR17","doi-asserted-by":"publisher","first-page":"409","DOI":"10.1007\/s10055-020-00464-4","volume":"25","author":"Y Wang","year":"2021","unstructured":"Wang Y, Hu Y, Chen Y (2021) An experimental investigation of menu selection for immersive virtual environments: fixed versus handheld menus. Virtual Reality 25(2):409\u2013419","journal-title":"Virtual Reality"},{"key":"2685_CR18","doi-asserted-by":"publisher","unstructured":"Clark L, Doyle P, Garaialde D, Gilmartin E, Schl\u00f6gl S, Edlund J, Aylett M, Cabral J, Munteanu C, Edwards J, R\u00a0Cowan B (2019) The state of speech in HCI: trends, themes and challenges. Interacting with Computers 31(4), 349\u2013371 https:\/\/doi.org\/10.1093\/iwc\/iwz016. https:\/\/academic.oup.com\/iwc\/article-pdf\/31\/4\/349\/33525046\/iwz016.pdf","DOI":"10.1093\/iwc\/iwz016"},{"key":"2685_CR19","doi-asserted-by":"crossref","unstructured":"Carruth DW, Hudson CR, Bethel CL, Pleva M, Ondas S, Juhar J (2019) Using hmd for immersive training of voice-based operation of small unmanned ground vehicles. In: International conference on human-computer interaction, pp 34\u201346. Springer","DOI":"10.1007\/978-3-030-21565-1_3"},{"key":"2685_CR20","doi-asserted-by":"crossref","unstructured":"Billinghurst M, Baldis S, Matheson L, Philips M (1997) 3d palette: a virtual reality content creation tool. In: Proceedings of the ACM symposium on virtual reality software and technology, pp 155\u2013156","DOI":"10.1145\/261135.261163"},{"key":"2685_CR21","doi-asserted-by":"crossref","unstructured":"Alibay F, Kavakli M, Chardonnet J.-R, Baig M.Z (2017) The usability of speech and\/or gestures in multi-modal interface systems. In: Proceedings of the 9th international conference on computer and automation engineering, pp 73\u201377","DOI":"10.1145\/3057039.3057089"},{"issue":"3","key":"2685_CR22","doi-asserted-by":"publisher","first-page":"262","DOI":"10.1145\/965105.807503","volume":"14","author":"RA Bolt","year":"1980","unstructured":"Bolt RA (1980) \u201cput-that-there\u2019\u2019: Voice and gesture at the graphics interface. SIGGRAPH Comput Graph 14(3):262\u2013270. https:\/\/doi.org\/10.1145\/965105.807503","journal-title":"SIGGRAPH Comput Graph"},{"key":"2685_CR23","doi-asserted-by":"crossref","unstructured":"Lupinetti K, Bonino B, Giannini F, Monti M (2019) Exploring the benefits of the virtual reality technologies for assembly retrieval applications. In: International conference on augmented reality, virtual reality and computer graphics, pp 43\u201359. Springer","DOI":"10.1007\/978-3-030-25965-5_5"},{"key":"2685_CR24","doi-asserted-by":"publisher","first-page":"66","DOI":"10.1016\/j.apergo.2017.12.016","volume":"69","author":"HK Kim","year":"2018","unstructured":"Kim HK, Park J, Choi Y, Choe M (2018) Virtual reality sickness questionnaire (vrsq): Motion sickness measurement index in a virtual reality environment. Appl Ergon 69:66\u201373","journal-title":"Appl Ergon"},{"key":"2685_CR25","doi-asserted-by":"crossref","unstructured":"Moss JD, Muth ER (2011) Characteristics of head-mounted displays and their effects on simulator sickness. Hum Factors 53(3):308\u2013319","DOI":"10.1177\/0018720811405196"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02685-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02685-1\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02685-1.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,27]],"date-time":"2022-09-27T12:37:20Z","timestamp":1664282240000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02685-1"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,15]]},"references-count":25,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,11]]}},"alternative-id":["2685"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02685-1","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,15]]},"assertion":[{"value":"11 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"19 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"15 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"The authors declare that they have no conflict of interest.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"All procedures performed in studies involving human participants were in accordance with the ethical standards of the institutional research committee and with the 1964 Declaration of Helsinki and its later amendments or comparable ethical standards.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethics approval"}},{"value":"Informed consent was obtained from all individual participants included in the study.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Consent to participate"}}]}}