{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T17:58:29Z","timestamp":1794333509826,"version":"4.9.0"},"reference-count":22,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,6,23]],"date-time":"2022-06-23T00:00:00Z","timestamp":1655942400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,6,23]],"date-time":"2022-06-23T00:00:00Z","timestamp":1655942400000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100002347","name":"Bundesministerium f\u00fcr Bildung und Forschung","doi-asserted-by":"publisher","award":["13GW0473A"],"award-info":[{"award-number":["13GW0473A"]}],"id":[{"id":"10.13039\/501100002347","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001659","name":"Deutsche Forschungsgemeinschaft","doi-asserted-by":"publisher","award":["HA 7819\/1-2"],"award-info":[{"award-number":["HA 7819\/1-2"]}],"id":[{"id":"10.13039\/501100001659","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title><jats:sec>\n                <jats:title>Purpose<\/jats:title>\n                <jats:p>Insertion point identification is a major challenge for percutaneous interventions. Planning in 2D slice image data is time-consuming and inefficient. Automated path planning can help to overcome these challenges. However, the setup of the intervention room is difficult to consider. In addition, transferring the insertion point to the skin is often prone to error. Therefore, a visualization for an automated path planning was implemented.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Methods<\/jats:title>\n                <jats:p>A condition-based automated path planning was calculated with path length, distance to risk structures and insertion angle. The results were displayed on a phantom using projector-based augmented reality (AR) with an access point selection using the insertion needle. Two variants of the insertion visualization and three target displays were evaluated in a user study.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Results<\/jats:title>\n                <jats:p>A visualization of insertion points with a representation of the path quality resulted in a choice of safer paths, compared with no insertion point display or no coding of the path quality. A representation of the target was preferred in the final survey, but did not perform better. A target display separate from the insertion point visualization reduced interferences between visualizations.<\/jats:p>\n              <\/jats:sec><jats:sec>\n                <jats:title>Conclusion<\/jats:title>\n                <jats:p>A projector-based AR visualization of automated path planning results supports insertion point identification for percutaneous interventions. A display of the path quality enables the choice of safe access paths especially for unexperienced users. Further research is needed to identify clinical benefits and applicability.<\/jats:p>\n              <\/jats:sec>","DOI":"10.1007\/s11548-022-02690-4","type":"journal-article","created":{"date-parts":[[2022,6,23]],"date-time":"2022-06-23T04:02:36Z","timestamp":1655956956000},"page":"2071-2079","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":3,"title":["Augmented reality visualization of automated path planning for percutaneous interventions: a phantom study"],"prefix":"10.1007","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4538-2201","authenticated-orcid":false,"given":"Lovis","family":"Schwenderling","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8169-3157","authenticated-orcid":false,"given":"Florian","family":"Heinrich","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5734-7529","authenticated-orcid":false,"given":"Christian","family":"Hansen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,6,23]]},"reference":[{"issue":"1","key":"2690_CR1","doi-asserted-by":"publisher","first-page":"29","DOI":"10.1186\/2047-783X-17-29","volume":"17","author":"F Pohlig","year":"2012","unstructured":"Pohlig F, Kirchhoff C, Lenze U, Schauwecker J, Burgkart R, Rechl H, von Eisenhart-Rothe R (2012) Percutaneous core needle biopsy versus open biopsy in diagnostics of bone and soft tissue sarcoma: a retrospective study. Eur J Med Res 17(1):29. https:\/\/doi.org\/10.1186\/2047-783X-17-29","journal-title":"Eur J Med Res"},{"issue":"Pt 2","key":"2690_CR2","doi-asserted-by":"publisher","first-page":"676","DOI":"10.1007\/978-3-540-75759-7_82","volume":"10","author":"C Baegert","year":"2007","unstructured":"Baegert C, Villard C, Schreck P, Soler L (2007) Multi-criteria trajectory planning for hepatic radiofrequency ablation. Med Image Comput Comput-assist Interv 10(Pt 2):676\u2013684. https:\/\/doi.org\/10.1007\/978-3-540-75759-7_82","journal-title":"Med Image Comput Comput-assist Interv"},{"key":"2690_CR3","doi-asserted-by":"publisher","unstructured":"Baegert C, Villard C, Schreck P, Soler L (2007) Precise determination of regions of interest for hepatic rfa planning. In: Medical imaging 2007: visualization and image-guided procedures, p 650923. https:\/\/doi.org\/10.1117\/12.708757","DOI":"10.1117\/12.708757"},{"issue":"6","key":"2690_CR4","doi-asserted-by":"publisher","first-page":"3246","DOI":"10.1118\/1.3590374","volume":"38","author":"A Seitel","year":"2011","unstructured":"Seitel A, Engel M, Sommer CM, Radeleff BA, Essert-Villard C, Baegert C, Fangerau M, Fritzsche KH, Yung K, Meinzer H-P, Maier-Hein L (2011) Computer-assisted trajectory planning for percutaneous needle insertions. Med Phys 38(6):3246\u20133259. https:\/\/doi.org\/10.1118\/1.3590374","journal-title":"Med Phys"},{"key":"2690_CR5","doi-asserted-by":"publisher","unstructured":"Shamir RR, Joskowicz L, Antiga L, Foroni RI, Shoshan Y (2010) Trajectory planning method for reduced patient risk in image-guided neurosurgery: concept and preliminary results. In: Medical imaging 2010: visualization, image-guided procedures, and modeling. SPIE Proceedings, p 76250. https:\/\/doi.org\/10.1117\/12.843991","DOI":"10.1117\/12.843991"},{"issue":"4","key":"2690_CR6","doi-asserted-by":"publisher","first-page":"517","DOI":"10.1007\/s11548-011-0651-8","volume":"7","author":"C Essert","year":"2012","unstructured":"Essert C, Haegelen C, Lalys F, Abadie A, Jannin P (2012) Automatic computation of electrode trajectories for deep brain stimulation: a hybrid symbolic and numerical approach. Int J Comput Assist Radiol Surg 7(4):517\u2013532. https:\/\/doi.org\/10.1007\/s11548-011-0651-8","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2690_CR7","doi-asserted-by":"publisher","DOI":"10.1155\/2014\/379295","author":"I Stenin","year":"2014","unstructured":"Stenin I, Hansen S, Becker M, Sakas G, Fellner D, Klenzner T, Schipper J (2014) Minimally invasive multiport surgery of the lateral skull base. BioMed Res Int. https:\/\/doi.org\/10.1155\/2014\/379295","journal-title":"BioMed Res Int"},{"issue":"2","key":"2690_CR8","doi-asserted-by":"publisher","first-page":"191","DOI":"10.1007\/s11548-011-0624-y","volume":"7","author":"C Schumann","year":"2012","unstructured":"Schumann C, Bieberstein J, Braunewell S, Niethammer M, Peitgen H-O (2012) Visualization support for the planning of hepatic needle placement. Int J Comput Assist Radiol Surgery 7(2):191\u2013197. https:\/\/doi.org\/10.1007\/s11548-011-0624-y","journal-title":"Int J Comput Assist Radiol Surgery"},{"key":"2690_CR9","doi-asserted-by":"publisher","unstructured":"Schumann C, Bieberstein J, Trumm C, Schmidt D, Bruners P, Niethammer M, Hoffmann RT, Mahnken AH, Pereira PL, Peitgen H-O (2010) Fast automatic path proposal computation for hepatic needle placement. In: Medical imaging 2010: visualization, image-guided procedures, and modeling, p 76251. https:\/\/doi.org\/10.1117\/12.844186","DOI":"10.1117\/12.844186"},{"issue":"6","key":"2690_CR10","doi-asserted-by":"publisher","first-page":"165","DOI":"10.1049\/htl.2019.0062","volume":"6","author":"F Heinrich","year":"2019","unstructured":"Heinrich F, Schwenderling L, Becker M, Skalej M, Hansen C (2019) Holoinjection: augmented reality support for ct-guided spinal needle injections. Healthc Technol Lett 6(6):165\u2013171. https:\/\/doi.org\/10.1049\/htl.2019.0062","journal-title":"Healthc Technol Lett"},{"key":"2690_CR11","doi-asserted-by":"publisher","unstructured":"Navkar NV, Tsekos NV, Stafford JR, Weinberg JS, Deng Z (2010) Visualization and planning of neurosurgical interventions with straight access. In: Information processing in computer-assisted interventions, vol 6135. Berlin, Heidelberg, pp 1\u201311. https:\/\/doi.org\/10.1007\/978-3-642-13711-2_1","DOI":"10.1007\/978-3-642-13711-2_1"},{"issue":"12","key":"2690_CR12","doi-asserted-by":"publisher","first-page":"2163","DOI":"10.1109\/TVCG.2011.184","volume":"17","author":"R Khlebnikov","year":"2011","unstructured":"Khlebnikov R, Kainz B, Muehl J, Schmalstieg D (2011) Crepuscular rays for tumor accessibility planning. IEEE Trans Vis Comput Gr 17(12):2163\u20132172. https:\/\/doi.org\/10.1109\/TVCG.2011.184","journal-title":"IEEE Trans Vis Comput Gr"},{"issue":"3","key":"2690_CR13","doi-asserted-by":"publisher","first-page":"944","DOI":"10.1016\/j.ijrobp.2007.10.048","volume":"70","author":"R Krempien","year":"2008","unstructured":"Krempien R, Hoppe H, Kahrs L, Daeuber S, Schorr O, Eggers G, Bischof M, Munter MW, Debus J, Harms W (2008) Projector-based augmented reality for intuitive intraoperative guidance in image-guided 3d interstitial brachytherapy. Int J Radiat Oncol Biol Phys 70(3):944\u2013952. https:\/\/doi.org\/10.1016\/j.ijrobp.2007.10.048","journal-title":"Int J Radiat Oncol Biol Phys"},{"issue":"6","key":"2690_CR14","doi-asserted-by":"publisher","first-page":"1015","DOI":"10.1007\/s11548-013-0897-4","volume":"8","author":"R Wen","year":"2013","unstructured":"Wen R, Chui C-K, Ong S-H, Lim K-B, Chang SK-Y (2013) Projection-based visual guidance for robot-aided rf needle insertion. Int J Comput Assist Radiol Surg 8(6):1015\u20131025. https:\/\/doi.org\/10.1007\/s11548-013-0897-4","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"2690_CR15","doi-asserted-by":"publisher","first-page":"48","DOI":"10.1515\/cdbme-2021-1011","volume":"7","author":"L Schwenderling","year":"2021","unstructured":"Schwenderling L, Hansen C, Heinrich F (2021) AR visualization of automated access path planning for percutaneous interventions. Curr Dir Biomed Eng 7(1):48\u201352. https:\/\/doi.org\/10.1515\/cdbme-2021-1011","journal-title":"Curr Dir Biomed Eng"},{"key":"2690_CR16","doi-asserted-by":"publisher","first-page":"225","DOI":"10.1049\/htl.2019.0062","volume":"173","author":"M Kersten-Oertel","year":"2012","unstructured":"Kersten-Oertel M, Chen SSJ, Drouin S, Sinclair DS, Collins DL (2012) Augmented reality visualization for guidance in neurovascular surgery. Stud Health Technol Inform 173:225\u2013229. https:\/\/doi.org\/10.1049\/htl.2019.0062","journal-title":"Stud Health Technol Inform"},{"issue":"3","key":"2690_CR17","doi-asserted-by":"publisher","first-page":"1192","DOI":"10.1007\/s00464-017-5791-7","volume":"32","author":"P Chauvet","year":"2018","unstructured":"Chauvet P, Collins T, Debize C, Novais-Gameiro L, Pereira B, Bartoli A, Canis M, Bourdel N (2018) Augmented reality in a tumor resection model. Surg Endosc 32(3):1192\u20131201. https:\/\/doi.org\/10.1007\/s00464-017-5791-7","journal-title":"Surg Endosc"},{"issue":"3","key":"2690_CR18","doi-asserted-by":"publisher","first-page":"419","DOI":"10.1007\/s11548-012-0790-6","volume":"8","author":"C Hansen","year":"2013","unstructured":"Hansen C, Zidowitz S, Ritter F, Lange C, Oldhafer K, Hahn HK (2013) Risk maps for liver surgery. Int J Comput Assist Radiol Surgery 8(3):419\u2013428. https:\/\/doi.org\/10.1007\/s11548-012-0790-6","journal-title":"Int J Comput Assist Radiol Surgery"},{"key":"2690_CR19","doi-asserted-by":"publisher","unstructured":"Heinrich F, Schmidt G, Jungmann F, Hansen C (2019) Augmented reality visualisation concepts to support intraoperative distance estimation. In: 25th ACM symposium on virtual reality software and technology, New York, pp 1\u20132. https:\/\/doi.org\/10.1145\/3359996.3364818","DOI":"10.1145\/3359996.3364818"},{"key":"2690_CR20","doi-asserted-by":"publisher","unstructured":"Heinrich F, Bornemann K, Lawonn K, Hansen C (2019) Depth perception in projective augmented reality: An evaluation of advanced visualization techniques. In: Trescak T, Simoff S, Richards D, Bogdanovych A, Duval T, Kuhlen T, Nguyen H, Morishima S, Itoh Y, Skarbez R, Masek M (eds) 25th ACM symposium on virtual reality software and technology, ACM, New York, pp 1\u201311. https:\/\/doi.org\/10.1145\/3359996.3364245","DOI":"10.1145\/3359996.3364245"},{"key":"2690_CR21","doi-asserted-by":"publisher","first-page":"782","DOI":"10.1093\/nar\/gkn613","volume":"37","author":"N Mitsuhashi","year":"2009","unstructured":"Mitsuhashi N, Fujieda K, Tamura T, Kawamoto S, Takagi T, Okubo K (2009) BodyParts3D: 3D structure database for anatomical concepts. Nucleic Acids Res 37:782\u20135. https:\/\/doi.org\/10.1093\/nar\/gkn613","journal-title":"Nucleic Acids Res"},{"issue":"7","key":"2690_CR22","doi-asserted-by":"publisher","first-page":"1195","DOI":"10.1007\/s11548-020-02153-8","volume":"15","author":"D Pour Arab","year":"2020","unstructured":"Pour Arab D, Voros S, Essert C (2020) Dynamic path planning for percutaneous procedures in the abdomen during free breathing. Int J Comput assist Radiol Surg 15(7):1195\u20131203. https:\/\/doi.org\/10.1007\/s11548-020-02153-8","journal-title":"Int J Comput assist Radiol Surg"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02690-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02690-4\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02690-4.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,27]],"date-time":"2022-09-27T12:36:57Z","timestamp":1664282217000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02690-4"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,6,23]]},"references-count":22,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,11]]}},"alternative-id":["2690"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02690-4","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,6,23]]},"assertion":[{"value":"10 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"25 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"23 June 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"This work is partially funded by the Federal Ministry of Education and Research (grant number 13GW0473A) and the German Research Foundation (grant number HA 7819\/1-2) within the STIMULATE research campus.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflicts of interest"}}]}}