{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,5]],"date-time":"2026-11-05T20:07:55Z","timestamp":1793909275206,"version":"4.8.0"},"reference-count":35,"publisher":"Springer Science and Business Media LLC","issue":"11","license":[{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"},{"start":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T00:00:00Z","timestamp":1656633600000},"content-version":"vor","delay-in-days":0,"URL":"https:\/\/creativecommons.org\/licenses\/by\/4.0"}],"funder":[{"DOI":"10.13039\/501100001655","name":"Deutscher Akademischer Austauschdienst","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001655","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["link.springer.com"],"crossmark-restriction":false},"short-container-title":["Int J CARS"],"abstract":"<jats:title>Abstract<\/jats:title>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Purpose<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>Augmented Reality (AR) has the potential to simplify ultrasound (US) examinations which usually require a skilled and experienced sonographer to mentally align narrow 2D cross-sectional US images in the 3D anatomy of the patient. This work describes and evaluates a novel approach to track retroreflective spheres attached to the US probe using an inside-out technique with the AR glasses HoloLens 2. Finally, live US images are displayed in situ on the imaged anatomy.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Methods<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>The Unity application UltrARsound performs spatial tracking of the US probe and attached retroreflective markers using the depth camera integrated into the AR glasses\u2014thus eliminating the need for an external tracking system. Additionally, a Kalman filter is implemented to improve the noisy measurements of the camera. US images are streamed wirelessly via the PLUS toolkit to HoloLens 2. The technical evaluation comprises static and dynamic tracking accuracy, frequency and latency of displayed images.<\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Results<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>\n                      Tracking is performed with a median accuracy of 1.98\u00a0mm\/1.81\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$^\\circ $$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:msup>\n                              <mml:mrow\/>\n                              <mml:mo>\u2218<\/mml:mo>\n                            <\/mml:msup>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      for the static setting when using the Kalman filter. In a dynamic scenario, the median error was 2.81\u00a0mm\/1.70\n                      <jats:inline-formula>\n                        <jats:alternatives>\n                          <jats:tex-math>$$^\\circ $$<\/jats:tex-math>\n                          <mml:math xmlns:mml=\"http:\/\/www.w3.org\/1998\/Math\/MathML\">\n                            <mml:msup>\n                              <mml:mrow\/>\n                              <mml:mo>\u2218<\/mml:mo>\n                            <\/mml:msup>\n                          <\/mml:math>\n                        <\/jats:alternatives>\n                      <\/jats:inline-formula>\n                      . The tracking frequency is currently limited to 20\u00a0Hz. 83% of the displayed US images had a latency lower than 16\u00a0ms.\n                    <\/jats:p>\n                  <\/jats:sec>\n                  <jats:sec>\n                    <jats:title>\n                      <jats:bold>Conclusions<\/jats:bold>\n                    <\/jats:title>\n                    <jats:p>In this work, we showed that spatial tracking of retroreflective spheres with the depth camera of HoloLens 2 is feasible, achieving a promising accuracy for in situ visualization of live US images. For tracking, no additional hardware nor modifications to HoloLens 2 are required making it a cheap and easy-to-use approach. Moreover, a minimal latency of displayed images enables a real-time perception for the sonographer.<\/jats:p>\n                  <\/jats:sec>","DOI":"10.1007\/s11548-022-02695-z","type":"journal-article","created":{"date-parts":[[2022,7,1]],"date-time":"2022-07-01T09:06:20Z","timestamp":1656666380000},"page":"2081-2091","update-policy":"https:\/\/doi.org\/10.1007\/springer_crossmark_policy","source":"Crossref","is-referenced-by-count":28,"title":["UltrARsound: in situ visualization of live ultrasound images using HoloLens 2"],"prefix":"10.1007","volume":"17","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9679-5693","authenticated-orcid":false,"given":"Felix","family":"von Haxthausen","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Rafael","family":"Moreta-Martinez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Alicia","family":"Pose D\u00edez de la Lastra","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Javier","family":"Pascau","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Floris","family":"Ernst","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"297","published-online":{"date-parts":[[2022,7,1]]},"reference":[{"key":"2695_CR1","volume-title":"Therapeutic ultrasound","author":"J-M Escoffre","year":"2015","unstructured":"Escoffre J-M, Bouakaz A (2015) Therapeutic ultrasound. Springer, Berlin"},{"issue":"1","key":"2695_CR2","doi-asserted-by":"publisher","first-page":"61","DOI":"10.1370\/afm.2330","volume":"17","author":"CA Andersen","year":"2019","unstructured":"Andersen CA, Holden S, Vela J, Rathleff MS, Jensen MB (2019) Point-of-care ultrasound in general practice: a systematic review. Ann Fam Med 17(1):61\u201369. https:\/\/doi.org\/10.1370\/afm.2330","journal-title":"Ann Fam Med"},{"issue":"6","key":"2695_CR3","doi-asserted-by":"publisher","first-page":"287","DOI":"10.1177\/8756479309351748","volume":"25","author":"K Evans","year":"2009","unstructured":"Evans K, Roll S, Baker J (2009) Work-related musculoskeletal disorders (WRMSD) among registered diagnostic medical sonographers and vascular technologists: A representative sample. J Diagn Med Sonogr 25(6):287\u2013299. https:\/\/doi.org\/10.1177\/8756479309351748","journal-title":"J Diagn Med Sonogr"},{"issue":"5","key":"2695_CR4","doi-asserted-by":"publisher","first-page":"1188","DOI":"10.1097\/ALN.0000000000000870","volume":"123","author":"A Shafqat","year":"2015","unstructured":"Shafqat A, Ferguson E, Thanawala V, Bedforth NM, Hardman JG, McCahon RA (2015) Visuospatial ability as a predictor of novice performance in ultrasound-guided regional anesthesia. Anesthesiology 123(5):1188\u20131197. https:\/\/doi.org\/10.1097\/ALN.0000000000000870","journal-title":"Anesthesiology"},{"key":"2695_CR5","doi-asserted-by":"publisher","first-page":"591","DOI":"10.1007\/BFb0047002","volume-title":"Visualization in biomedical computing","author":"H Fuchs","year":"1996","unstructured":"Fuchs H, State A, Pisano ED, Garrett WF, Hirota G, Livingston M, Whitton MC, Pizer SM (1996) Towards performing ultrasound-guided needle biopsies from within a head-mounted display. In: H\u00f6hne KH, Kikinis R (eds) Visualization in biomedical computing. Springer, Berlin, Heidelberg, pp 591\u2013600"},{"key":"2695_CR6","doi-asserted-by":"publisher","DOI":"10.3390\/bioengineering8100131","author":"N Cattari","year":"2021","unstructured":"Cattari N, Condino S, Cutolo F, Ferrari M, Ferrari V (2021) In situ visualization for 3d ultrasound-guided interventions with augmented reality headset. Bioengineering. https:\/\/doi.org\/10.3390\/bioengineering8100131","journal-title":"Bioengineering"},{"key":"2695_CR7","doi-asserted-by":"publisher","first-page":"189","DOI":"10.1049\/htl.2018.5061","volume":"5","author":"H El-Hariri","year":"2018","unstructured":"El-Hariri H (2018) Augmented reality visualisation for orthopaedic surgical guidance with pre- and intra-operative multimodal image data fusion. Healthcare Technol Lett 5:189\u20131934","journal-title":"Healthcare Technol Lett"},{"key":"2695_CR8","doi-asserted-by":"publisher","unstructured":"Kuzhagaliyev T, Clancy NT, Janatka M, Tchaka K, Vasconcelos F, Clarkson MJ, Gurusamy K, Hawkes DJ, Davidson B, Stoyanov D (2018) Augmented reality needle ablation guidance tool for irreversible electroporation in the pancreas. In: Fei B, III, RJW (eds.) Medical imaging 2018: Image-guided procedures, robotic interventions, and modeling, vol. 10576, pp. 260\u2013265. SPIE, ??? (2018). https:\/\/doi.org\/10.1117\/12.2293671. International Society for Optics and Photonics","DOI":"10.1117\/12.2293671"},{"issue":"11","key":"2695_CR9","doi-asserted-by":"publisher","first-page":"1895","DOI":"10.1007\/s11548-020-02236-6","volume":"15","author":"C R\u00fcger","year":"2020","unstructured":"R\u00fcger C, Feufel MA, Moosburner S, \u00d6zbek C, Pratschke J, Sauer IM (2020) Ultrasound in augmented reality: a mixed-methods evaluation of head-mounted displays in image-guided interventions. Int J Comput Assist Radiol Surg 15(11):1895\u20131905. https:\/\/doi.org\/10.1007\/s11548-020-02236-6","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"1","key":"2695_CR10","doi-asserted-by":"publisher","first-page":"86","DOI":"10.1177\/1553350618799552","volume":"26","author":"JW Meulstee","year":"2019","unstructured":"Meulstee JW, Nijsink J, Schreurs R, Verhamme LM, Xi T, Delye HHK, Borstlap WA, Maal TJJ (2019) Toward holographic-guided surgery. Surgical Innov 26(1):86\u201394. https:\/\/doi.org\/10.1177\/1553350618799552 (PMID: 30261829)","journal-title":"Surgical Innov"},{"issue":"3","key":"2695_CR11","doi-asserted-by":"publisher","first-page":"167","DOI":"10.1515\/iss-2018-2001","volume":"3","author":"V Garc\u00eda-V\u00e1zquez","year":"2018","unstructured":"Garc\u00eda-V\u00e1zquez V, von Haxthausen F, J\u00e4ckle S, Schumann C, Kuhlemann I, Bouchagiar J, H\u00f6fer A-C, Matysiak F, H\u00fcttmann G, Goltz JP, Kleemann M, Ernst F, Horn M (2018) Navigation and visualisation with hololens in endovascular aortic repair. Innov Surg Sci 3(3):167\u2013177. https:\/\/doi.org\/10.1515\/iss-2018-2001","journal-title":"Innov Surg Sci"},{"issue":"5","key":"2695_CR12","doi-asserted-by":"publisher","first-page":"184","DOI":"10.1049\/htl.2017.0061","volume":"4","author":"I Kuhlemann","year":"2017","unstructured":"Kuhlemann I, Kleemann M, Jauer P, Schweikard A, Ernst F (2017) Towards x-ray free endovascular interventions - using hololens for on-line holographic visualisation. Healthcare Technol Lett 4(5):184\u2013187. https:\/\/doi.org\/10.1049\/htl.2017.0061","journal-title":"Healthcare Technol Lett"},{"issue":"7","key":"2695_CR13","doi-asserted-by":"publisher","first-page":"1157","DOI":"10.1007\/s11548-019-01973-7","volume":"14","author":"F Liebmann","year":"2019","unstructured":"Liebmann F, Roner S, von Atzigen M, Scaramuzza D, Sutter R, Snedeker J, Farshad M, F\u00fcrnstahl P (2019) Pedicle screw navigation using surface digitization on the microsoft hololens. Int J Comput Assist Radiol Surg 14(7):1157\u20131165. https:\/\/doi.org\/10.1007\/s11548-019-01973-7","journal-title":"Int J Comput Assist Radiol Surg"},{"issue":"5","key":"2695_CR14","doi-asserted-by":"publisher","first-page":"162","DOI":"10.1049\/htl.2018.5072","volume":"5","author":"R Moreta-Martinez","year":"2018","unstructured":"Moreta-Martinez R, Garc\u00eda-Mato D, Garc\u00eda-Sevilla M, P\u00e9rez-Ma\u00f1anes R, Calvo-Haro J, Pascau J (2018) Augmented reality in computer-assisted interventions based on patient-specific 3D printed reference. Healthc Technol Lett 5(5):162\u2013166. https:\/\/doi.org\/10.1049\/htl.2018.5072","journal-title":"Healthc Technol Lett"},{"issue":"9","key":"2695_CR15","doi-asserted-by":"publisher","first-page":"1447","DOI":"10.1007\/s00402-020-03542-z","volume":"141","author":"P Kriechling","year":"2021","unstructured":"Kriechling P, Roner S, Liebmann F, Casari F, F\u00fcrnstahl P, Wieser K (2021) Augmented reality for base plate component placement in reverse total shoulder arthroplasty: a feasibility study. Arch Orthop Trauma Surg 141(9):1447\u20131453. https:\/\/doi.org\/10.1007\/s00402-020-03542-z","journal-title":"Arch Orthop Trauma Surg"},{"key":"2695_CR16","doi-asserted-by":"publisher","first-page":"74","DOI":"10.1007\/978-3-030-32254-0_9","volume-title":"Medical image computing and computer assisted intervention - MICCAI 2019","author":"L Qian","year":"2019","unstructured":"Qian L, Zhang X, Deguet A, Kazanzides P (2019) Aramis: augmented reality assistance for minimally invasive surgery using a head-mounted display. In: Shen D, Liu T, Peters TM, Staib LH, Essert C, Zhou S, Yap P-T, Khan A (eds) Medical image computing and computer assisted intervention - MICCAI 2019. Springer, Cham, pp 74\u201382"},{"key":"2695_CR17","doi-asserted-by":"publisher","unstructured":"Carbone M, Condino S, Cutolo F, Viglialoro RM, Kaschke O, Thomale UW, Ferrari V (2018) Proof of concept: wearable augmented reality video see-through display for neuro-endoscopy. In: De Paolis LT, Bourdot P (eds.) Augmented reality, virtual reality, and computer graphics, pp. 95\u2013104. Springer, Cham . https:\/\/doi.org\/10.1007\/978-3-319-95282-6_7","DOI":"10.1007\/978-3-319-95282-6_7"},{"issue":"1","key":"2695_CR18","doi-asserted-by":"publisher","first-page":"20200027","DOI":"10.1515\/cdbme-2020-0027","volume":"6","author":"C Kunz","year":"2020","unstructured":"Kunz C, Maurer P, Kees F, Henrich P, Marzi C, Hlav\u00e1\u010d M, Schneider M, Mathis-Ullrich F (2020) Infrared marker tracking with the hololens for neurosurgical interventions. Curr Dir Biomed Eng 6(1):20200027. https:\/\/doi.org\/10.1515\/cdbme-2020-0027","journal-title":"Curr Dir Biomed Eng"},{"key":"2695_CR19","doi-asserted-by":"publisher","unstructured":"Gsaxner C, Li J, Pepe A, Schmalstieg D, Egger J (2021) Inside-out instrument tracking for surgical navigation in augmented reality. In: Proceedings of the 27th ACM symposium on virtual reality software and technology. VRST \u201921. Association for computing machinery, New York, NY, USA. https:\/\/doi.org\/10.1145\/3489849.3489863","DOI":"10.1145\/3489849.3489863"},{"issue":"3","key":"2695_CR20","doi-asserted-by":"publisher","first-page":"1363","DOI":"10.1053\/j.jvca.2017.12.006","volume":"32","author":"F Mahmood","year":"2018","unstructured":"Mahmood F, Mahmood E, Dorfman RG, Mitchell J, Mahmood FU, Jones SB, Matyal R (2018) Augmented reality and ultrasound education: initial experience. J Cardiothorac Vasc Anesth 32(3):1363\u20131367. https:\/\/doi.org\/10.1053\/j.jvca.2017.12.006","journal-title":"J Cardiothorac Vasc Anesth"},{"key":"2695_CR21","doi-asserted-by":"publisher","DOI":"10.1186\/s41747-019-0129-y","author":"NA Farshad-Amacker","year":"2020","unstructured":"Farshad-Amacker NA, Bay T, Rosskopf AB, Spirig JM, Wanivenhaus F, Pfirrmann CWA, Farshad M (2020) Ultrasound-guided interventions with augmented reality in situ visualisation: a proof-of-mechanism phantom study. Eur Radiol Exp. https:\/\/doi.org\/10.1186\/s41747-019-0129-y","journal-title":"Eur Radiol Exp"},{"key":"2695_CR22","doi-asserted-by":"publisher","DOI":"10.1007\/s11548-021-02526-7","author":"T Nguyen","year":"2021","unstructured":"Nguyen T, Plishker W, Matisoff A, Sharma K, Shekhar R (2021) Holous: augmented reality visualization of live ultrasound images using hololens for ultrasound-guided procedures. Int J Comput Assist Radiol Surg. https:\/\/doi.org\/10.1007\/s11548-021-02526-7","journal-title":"Int J Comput Assist Radiol Surg"},{"key":"2695_CR23","unstructured":"Gu W (2021) HoloLens2-ResearchMode-Unity: Unity Plugin for using research mode functionality in HoloLens 2. Modified based on HoloLens2ForCV. https:\/\/github.com\/petergu684\/HoloLens2-ResearchMode-Unity. Accessed: 25 May 2021"},{"key":"2695_CR24","unstructured":"Ungureanu D, Bogo F, Galliani S, Sama P, Duan X, Meekhof C, St\u00fchmer J, Cashman TJ, Tekin B, Sch\u00f6nberger JL, Olszta P, Pollefeys M (2020) Hololens 2 research mode as a tool for computer vision research. arXiv"},{"issue":"1","key":"2695_CR25","doi-asserted-by":"publisher","first-page":"35","DOI":"10.1115\/1.3662552","volume":"82","author":"RE Kalman","year":"1960","unstructured":"Kalman RE (1960) A new approach to linear filtering and prediction problems. J Basic Eng 82(1):35\u201345. https:\/\/doi.org\/10.1115\/1.3662552","journal-title":"J Basic Eng"},{"issue":"2","key":"2695_CR26","doi-asserted-by":"publisher","first-page":"1","DOI":"10.3390\/s21020413","volume":"21","author":"M T\u00f6lgyessy","year":"2021","unstructured":"T\u00f6lgyessy M, Dekan M, Chovanec L, Hubinsk\u00fd P (2021) Evaluation of the azure kinect and its comparison to kinect v1 and kinect v2. Sensors 21(2):1\u201325. https:\/\/doi.org\/10.3390\/s21020413","journal-title":"Sensors"},{"issue":"5","key":"2695_CR27","doi-asserted-by":"publisher","first-page":"698","DOI":"10.1109\/TPAMI.1987.4767965","volume":"9","author":"KS Arun","year":"1987","unstructured":"Arun KS, Huang TS, Blostein SD (1987) Least-squares fitting of two 3-d point sets. IEEE Trans Pattern Anal Mach Intell 9(5):698\u2013700. https:\/\/doi.org\/10.1109\/TPAMI.1987.4767965","journal-title":"IEEE Trans Pattern Anal Mach Intell"},{"issue":"10","key":"2695_CR28","doi-asserted-by":"publisher","first-page":"2527","DOI":"10.1109\/TBME.2014.2322864","volume":"61","author":"A Lasso","year":"2014","unstructured":"Lasso A, Heffter T, Rankin A, Pinter C, Ungi T, Fichtinger G (2014) Plus: open-source toolkit for ultrasound-guided intervention ystems. IEEE Trans Biomed Eng 61(10):2527\u20132537. https:\/\/doi.org\/10.1109\/TBME.2014.2322864","journal-title":"IEEE Trans Biomed Eng"},{"issue":"4","key":"2695_CR29","doi-asserted-by":"publisher","first-page":"423","DOI":"10.1002\/rcs.274","volume":"5","author":"J Tokuda","year":"2009","unstructured":"Tokuda J, Fischer GS, Papademetris X, Yaniv Z, Ibanez L, Cheng P, Liu H, Blevins J, Arata J, Golby AJ, Kapur T, Pieper S, Burdette EC, Fichtinger G, Tempany CM, Hata N (2009) Openigtlink: an open network protocol for image-guided therapy environment. Int J Med Robot 5(4):423\u2013434. https:\/\/doi.org\/10.1002\/rcs.274","journal-title":"Int J Med Robot"},{"key":"2695_CR30","unstructured":"SlicerIGT-community: User tutorial U31 - Tracked ultrasound calibration. http:\/\/www.slicerigt.org\/wp\/user-tutorial\/. Accessed: 25 May 2021 (2016)"},{"key":"2695_CR31","doi-asserted-by":"publisher","unstructured":"Welch M, Andrea J, Ungi T, Fichtinger G (2013) Freehand ultrasound calibration: phantom versus tracked pointer. In: III DRH, Yaniv ZR (eds) Medical imaging 2013: image-guided procedures, robotic interventions, and modeling, vol. 8671, pp. 348\u2013353. SPIE. https:\/\/doi.org\/10.1117\/12.2007922. International Society for Optics and Photonics","DOI":"10.1117\/12.2007922"},{"key":"2695_CR32","unstructured":"Plus: Plus toolkit - printable 3D models catalog. http:\/\/perk-software.cs.queensu.ca\/plus\/doc\/nightly\/modelcatalog\/. Accessed: 25 May 2021 (2020)"},{"issue":"2","key":"2695_CR33","doi-asserted-by":"publisher","first-page":"155","DOI":"10.1007\/s10851-009-0161-2","volume":"35","author":"DQ Huynh","year":"2009","unstructured":"Huynh DQ (2009) Metrics for 3D rotations: comparison and analysis. J Math Imag Vis 35(2):155\u2013164. https:\/\/doi.org\/10.1007\/s10851-009-0161-2","journal-title":"J Math Imag Vis"},{"key":"2695_CR34","doi-asserted-by":"publisher","unstructured":"Bamji CS, Mehta S, Thompson B, Elkhatib T, Wurster S, Akkaya O, Payne A, Godbaz J, Fenton M, Rajasekaran V, Prather L, Nagaraja S, Mogallapu V, Snow D, McCauley R, Mukadam M, Agi I, McCarthy S, Xu Z, Perry T, Qian W, Chan V-H, Adepu P, Ali G, Ahmed M, Mukherjee A, Nayak S, Gampell D, Acharya S, Kordus L, O\u2019Connor P (2018) Impixel 65nm bsi 320mhz demodulated tof image sensor with 3$$\\mu $$m global shutter pixels and analog binning. In: 2018 IEEE international solid - state circuits conference - (ISSCC), pp. 94\u201396. https:\/\/doi.org\/10.1109\/ISSCC.2018.8310200","DOI":"10.1109\/ISSCC.2018.8310200"},{"issue":"4","key":"2695_CR35","doi-asserted-by":"publisher","first-page":"1021","DOI":"10.3390\/s20041021","volume":"20","author":"P H\u00fcbner","year":"2020","unstructured":"H\u00fcbner P, Clintworth K, Liu Q, Weinmann M, Wursthorn S (2020) Evaluation of hololens tracking and depth sensing for indoor mapping applications. Sensors 20(4):1021. https:\/\/doi.org\/10.3390\/s20041021","journal-title":"Sensors"}],"container-title":["International Journal of Computer Assisted Radiology and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02695-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/article\/10.1007\/s11548-022-02695-z\/fulltext.html","content-type":"text\/html","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/link.springer.com\/content\/pdf\/10.1007\/s11548-022-02695-z.pdf","content-type":"application\/pdf","content-version":"vor","intended-application":"similarity-checking"}],"deposited":{"date-parts":[[2022,9,27]],"date-time":"2022-09-27T08:36:55Z","timestamp":1664267815000},"score":1,"resource":{"primary":{"URL":"https:\/\/link.springer.com\/10.1007\/s11548-022-02695-z"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,7,1]]},"references-count":35,"journal-issue":{"issue":"11","published-online":{"date-parts":[[2022,11]]}},"alternative-id":["2695"],"URL":"https:\/\/doi.org\/10.1007\/s11548-022-02695-z","relation":{},"ISSN":["1861-6429"],"issn-type":[{"value":"1861-6429","type":"electronic"}],"subject":[],"published":{"date-parts":[[2022,7,1]]},"assertion":[{"value":"13 January 2022","order":1,"name":"received","label":"Received","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"31 May 2022","order":2,"name":"accepted","label":"Accepted","group":{"name":"ArticleHistory","label":"Article History"}},{"value":"1 July 2022","order":3,"name":"first_online","label":"First Online","group":{"name":"ArticleHistory","label":"Article History"}},{"order":1,"name":"Ethics","group":{"name":"EthicsHeading","label":"Declarations"}},{"value":"All authors certify that they have no affiliations with or involvement in any organization or entity with any financial interest or non-financial interest in the subject matter or materials discussed in this manuscript.","order":2,"name":"Ethics","group":{"name":"EthicsHeading","label":"Conflict of interest"}},{"value":"No ethical approval was needed for this phantom study.","order":3,"name":"Ethics","group":{"name":"EthicsHeading","label":"Ethical approval"}},{"value":"For this type of study, formal consent is not required.","order":4,"name":"Ethics","group":{"name":"EthicsHeading","label":"Informed consent"}}]}}